Ganesh C. Patil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Ganesh C. Patil has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
S. Qureshi
Department of Electrical Engineering, Indian Institute of Technology Kanpur, Kanpur, Uttarpradesh, India
7 shared publications- Rajesh C. Junghare
Visvesvaraya National Institute of Technology
6 shared publications - Deepika Singh
Center for VLSI and Nanotechnology, Visvesvaraya National Institute of Technology, Nagpur 440010, India
3 shared publications - Gopal S. Pranjale
Visvesvaraya National Institute of Technology, Nagpur, Maharashtra, India
3 shared publications - Ishan C. Ghosekar
Chemistry and Physics of Materials Unit, Jawaharlal Nehru Centre for Advanced Scientific Research, Bangalore, India
3 shared publications S Qureshi
3 shared publications
Latest Publications
- 2 July 2026
- Published by Springer Nature
- p. 144-154
Ab-Initio Tight Binding Study on Defects in Armchair Silicene Nanoribbon Double Gate Field Effect Transistor
- 2 July 2026
- Published by Springer Nature
- p. 144-154
Ab-Initio Tight Binding Study on Defects in Armchair Silicene Nanoribbon Double Gate Field Effect Transistor
- 2 December 2024
- Published by Elsevier in Journal of the Indian Chemical Society
- Vol. 101 (12)
Analysis and fabrication of paper based screen-printed soil potassium sensor
- 2 December 2024
- Published by Elsevier in Journal of the Indian Chemical Society
- Vol. 101 (12)
Analysis and fabrication of paper based screen-printed soil potassium sensor
- 26 November 2024
- Published by Springer Nature in Graphene and 2D Materials
- Vol. 9 (3-4) , 263-274
A2D Sim: atom-to-device simulation platform for quantum device simulations
- 26 November 2024
- Published by Springer Nature in Graphene and 2D Materials
- Vol. 9 (3-4) , 263-274
A2D Sim: atom-to-device simulation platform for quantum device simulations
- 1 November 2024
- Published by The Electrochemical Society in ECS Journal of Solid State Science and Technology
- Vol. 13 (11) , 117006
Fabrication of MOSCAP and VARICAP Based Soil Sensors Using Low-Cost Solution Processing
In this work, for the first time metal-oxide semiconductor capacitor (MOSCAP) and variable capacitor diode (VARICAP) sensors are fabricated for the detection of soil macronutrients such as nitrate (N), phosphate (P) and the potash (K). The thin-film MOSCAP is fabricated by using the zinc oxide (ZnO) as semiconducting layer and the silicon dioxide (SiO2) as the dielectric layer whereas the thin film VARICAP is comprised of FTO-coated glass as anode and chemically synthesized aluminium doped zinc oxide (AZO) as the semiconducting layer. The anode and the cathode electrodes for both the devices are formed by using the low-cost screen-printing technique. Although the fabricated sensors are not characterised, the steps to characterise both MOSCAP and the VARICAP soil sensors for detecting N, P and K are also proposed. The necessary ionophores found for the detection of N, P and K are tetradodecylammonium nitrate (TDDAN), tributyltin chloride and valinomycin respectively. Thus, this paper presents a comprehensive study on fabricating solid state capacitive sensors for the detection of N, P and K soil micronutrients by using low-cost solution processing.
- 1 November 2024
- Published by The Electrochemical Society in ECS Journal of Solid State Science and Technology
- Vol. 13 (11) , 117006
Fabrication of MOSCAP and VARICAP Based Soil Sensors Using Low-Cost Solution Processing
In this work, for the first time metal-oxide semiconductor capacitor (MOSCAP) and variable capacitor diode (VARICAP) sensors are fabricated for the detection of soil macronutrients such as nitrate (N), phosphate (P) and the potash (K). The thin-film MOSCAP is fabricated by using the zinc oxide (ZnO) as semiconducting layer and the silicon dioxide (SiO2) as the dielectric layer whereas the thin film VARICAP is comprised of FTO-coated glass as anode and chemically synthesized aluminium doped zinc oxide (AZO) as the semiconducting layer. The anode and the cathode electrodes for both the devices are formed by using the low-cost screen-printing technique. Although the fabricated sensors are not characterised, the steps to characterise both MOSCAP and the VARICAP soil sensors for detecting N, P and K are also proposed. The necessary ionophores found for the detection of N, P and K are tetradodecylammonium nitrate (TDDAN), tributyltin chloride and valinomycin respectively. Thus, this paper presents a comprehensive study on fabricating solid state capacitive sensors for the detection of N, P and K soil micronutrients by using low-cost solution processing.
- 19 October 2024
- Published by Springer Nature
- p. 215-222
Comparative Study of FET Based Biosensors with Metal Oxide Stacked Sensing Membrane
- 19 October 2024
- Published by Springer Nature
- p. 215-222
Comparative Study of FET Based Biosensors with Metal Oxide Stacked Sensing Membrane
- 12 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (18) , 28611-28618
Split Gate Bulk-Planar Junctionless FET-Based Biosensor for Label-Free Detection of Biomolecules
In this paper, for the first time we demonstrate the fabrication of low cost split gate bulk planar junctionless field effect transistor (SG-BPJLFET) for biosensing applications. In the fabrication process, the junctionless concept has been incorporated to reduce the thermal budget, random dopant fluctuations and the fabrication complexities of the device. The measured transfer characteristics of the fabricated SG-BPJLFET show improved I ON /I OFF ratio of ~ 10 7 with the calculated mobility of 9.72 cm 2 /V-s and the charge carrier density of 1×10 18 cm −3 . For the fabricated device the Debye’s length is found to be 6.45 nm which can be used for the detection of protein complexes (such as streptavidin-biotin) by using 0.01 × PBS (Phosphate buffer solution) in solution. The fabricated device is further simulated for the detection of biomolecules such as streptavidin and biotin. From the simulated results, it has been observed that the device has the capability to be used as a biosensor for detection of various protein complexes with higher sensitivity and selectivity.
- 12 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (18) , 28611-28618
Split Gate Bulk-Planar Junctionless FET-Based Biosensor for Label-Free Detection of Biomolecules
In this paper, for the first time we demonstrate the fabrication of low cost split gate bulk planar junctionless field effect transistor (SG-BPJLFET) for biosensing applications. In the fabrication process, the junctionless concept has been incorporated to reduce the thermal budget, random dopant fluctuations and the fabrication complexities of the device. The measured transfer characteristics of the fabricated SG-BPJLFET show improved I ON /I OFF ratio of ~ 10 7 with the calculated mobility of 9.72 cm 2 /V-s and the charge carrier density of 1×10 18 cm −3 . For the fabricated device the Debye’s length is found to be 6.45 nm which can be used for the detection of protein complexes (such as streptavidin-biotin) by using 0.01 × PBS (Phosphate buffer solution) in solution. The fabricated device is further simulated for the detection of biomolecules such as streptavidin and biotin. From the simulated results, it has been observed that the device has the capability to be used as a biosensor for detection of various protein complexes with higher sensitivity and selectivity.
- 21 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (13) , 20360-20367
Paper-Based Screen-Printed Electrodes: A Cost-Effective Solution for Soil Potassium Sensing
In this paper, we fabricated three electrode electrochemical sensor for the detection of potassium (K + ) in the soil. Since potassium in the soil directly impacts on the growth of the plants, it is necessary to detect the potassium. To achieve this, the low cost polyethylene terephthalate (PET) paper- based potassium sensor has been designed and fabricated by using the screen-printing technique. With the proposed fabrication setup, we have fabricated 63 sensors on A4 size PET sheet. The three electrodes in the sensor are counter electrode (CE), working electrode (WE) and the reference electrode (RE) which are analyzed by using the cyclic voltammetry. The fundamental principle of this sensor is based on the ion sensitive membrane (ISM) used on the WE. Therefore, the valinomycin is used as the ISM for sensing the K + ions. It has also been observed that, the selectivity and the sensitivity of the proposed sensor are significantly higher in comparison to the reported valinomycin based sensors. Since the proposed sensor uses the paper-based approach, the cost of each fabricated sensor is around $0.06 (₹5).
- 21 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (13) , 20360-20367
Paper-Based Screen-Printed Electrodes: A Cost-Effective Solution for Soil Potassium Sensing
In this paper, we fabricated three electrode electrochemical sensor for the detection of potassium (K + ) in the soil. Since potassium in the soil directly impacts on the growth of the plants, it is necessary to detect the potassium. To achieve this, the low cost polyethylene terephthalate (PET) paper- based potassium sensor has been designed and fabricated by using the screen-printing technique. With the proposed fabrication setup, we have fabricated 63 sensors on A4 size PET sheet. The three electrodes in the sensor are counter electrode (CE), working electrode (WE) and the reference electrode (RE) which are analyzed by using the cyclic voltammetry. The fundamental principle of this sensor is based on the ion sensitive membrane (ISM) used on the WE. Therefore, the valinomycin is used as the ISM for sensing the K + ions. It has also been observed that, the selectivity and the sensitivity of the proposed sensor are significantly higher in comparison to the reported valinomycin based sensors. Since the proposed sensor uses the paper-based approach, the cost of each fabricated sensor is around $0.06 (₹5).
- 1 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanotechnology
- Vol. 23 (1536125X) , 408-414
Performance Comparison of 2D Mono-Elemental (X-enes) Armchair Nanoribbon Schottky Barrier Field Effect Transistors
In this work, comprehensive analysis of Schottky barrier (SB) field effect transistors (FETs) having 2D mono-elemental (X-enes) nanoribbon (NR) with width of 10 dimers along the armchair direction as a channel material has been carried out. The multi-scale approach used for simulating the hydrogen passivated X-ene NR SBFETs consists of density functional theory (DFT), Wannier function based tight binding and the non-equilibrium Green's Function formalism (NEGF). The derived bandgaps for X-enes such as graphene, germanene, phosphorene and silicene are 1.27, 0.379, 1.036 and 0.431 eV respectively. To incorporate the effect of band-bending at the metal-X-ene interface the modification in the conventional multi-scale approach has also been proposed. To mimic the effect of band bending at metal-X-ene interface the schemes proposed in the model are, addition of equivalent channel potential energy in the Hamiltonian matrix and the addition of fixed charges in initial charge profile. Further, the impact of SB width, Fermi level pinning and the scattering on the device performance has also been explored. The results show that the on-state drive current-to-off-state leakage current ratio in the case of graphene and phosphorene SBFETs is up-to the order ∼10 7 whereas for silicene and germanene SBFETs it is in the order of ∼10 3 .
- 1 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanotechnology
- Vol. 23 (1536125X) , 408-414
Performance Comparison of 2D Mono-Elemental (X-enes) Armchair Nanoribbon Schottky Barrier Field Effect Transistors
In this work, comprehensive analysis of Schottky barrier (SB) field effect transistors (FETs) having 2D mono-elemental (X-enes) nanoribbon (NR) with width of 10 dimers along the armchair direction as a channel material has been carried out. The multi-scale approach used for simulating the hydrogen passivated X-ene NR SBFETs consists of density functional theory (DFT), Wannier function based tight binding and the non-equilibrium Green's Function formalism (NEGF). The derived bandgaps for X-enes such as graphene, germanene, phosphorene and silicene are 1.27, 0.379, 1.036 and 0.431 eV respectively. To incorporate the effect of band-bending at the metal-X-ene interface the modification in the conventional multi-scale approach has also been proposed. To mimic the effect of band bending at metal-X-ene interface the schemes proposed in the model are, addition of equivalent channel potential energy in the Hamiltonian matrix and the addition of fixed charges in initial charge profile. Further, the impact of SB width, Fermi level pinning and the scattering on the device performance has also been explored. The results show that the on-state drive current-to-off-state leakage current ratio in the case of graphene and phosphorene SBFETs is up-to the order ∼10 7 whereas for silicene and germanene SBFETs it is in the order of ∼10 3 .
- 3 July 2023
- Published by Springer Nature
- p. 509-530
Doctor Blade: A Promising Technique for Thin Film Coating
- 3 July 2023
- Published by Springer Nature
- p. 509-530
Doctor Blade: A Promising Technique for Thin Film Coating