Manoj Bob Kusuma
Research Subjects
Research Interests
Manoj Bob Kusuma has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Krishnamurthy Bhat
Department of Pharmaceutical Quality Assurance, Manipal College of Pharmaceutical Sciences, Manipal Academy of Higher Education, Manipal, Karnataka 576104, India
4 shared publicationsPraveen Vithala
Bioanalytical Research Department, Lupin Bio-Research Center, Pashan, Pune 411021, Maharashtra State, India
4 shared publicationsRavisekhar Kashibhatta
Bioanalytical Research Department, Lupin Bio-Research Center, Pashan, Pune 411021, Maharashtra State, India
4 shared publicationsSudheer Moorkoth
Department of Pharmaceutical Quality Assurance, Manipal College of Pharmaceutical Sciences, Manipal Academy of Higher Education, Manipal, Karnataka 576104, India
4 shared publicationsAnil Gavande
Bioanalytical Research Department, Lupin Bio-Research Center, Pashan, Pune 411021, Maharashtra State, India
2 shared publications- Muddukrishna Badamane Sathyanarayana
Manipal Academy of Higher Education
2 shared publications
Latest Publications
- 13 October 2026
- Published by Taylor & Francis in Bioanalysis
- Vol. 18 (14-15) , 1317-1330
Bioanalytical assays for clinical similarity assessment of biotherapeutics: evolving platforms and regulatory considerations
1. Biologic medicines have transformed the therapeutic landscape for many chronic and severe diseases by enabling highly specific targeting of disease pathways. Biologic products encompass a broad ...
- 13 October 2026
- Published by Taylor & Francis in Bioanalysis
- Vol. 18 (14-15) , 1317-1330
Bioanalytical assays for clinical similarity assessment of biotherapeutics: evolving platforms and regulatory considerations
1. Biologic medicines have transformed the therapeutic landscape for many chronic and severe diseases by enabling highly specific targeting of disease pathways. Biologic products encompass a broad ...
- Open Access
- 9 March 2026
- Published by MDPI AG in Preprints.org
Quantitative Evaluation of VEGF in Human Plasma Using ELISA and MSD Platforms for Pharmacodynamic Assessment
Precise quantitative determination of Vascular Endothelial Growth Factor (VEGF) in human plasma is critical for pharmacodynamic (PD) evaluation of anti-VEGF therapeutics. In this study, we developed and optimized two immunoassay platforms, including the enzyme-linked immunosorbent assay (ELISA) and the Meso Scale Discovery (MSD), for estimating VEGF. A direct sandwich ELISA was validated to quantify pharmacodynamic biomarker VEGF in human plasma using the Human VEGF Quantikine Kit, demonstrating a quantification range of 62.5–2000.0 pg/mL and a sensitivity of 47.5 pg/mL. In parallel, a sandwich electrochemiluminescence (ECL) assay was developed using the V-PLEX Plus Human VEGF Kit on the MSD platform, achieving a lower quantification range of 7.7–562.0 pg/mL. Comparative analysis revealed that MSD ECL detection with Sulfo Tag labeling outperformed traditional colorimetric ELISA in terms of signal amplification and dynamic range, making it a valuable tool for PD biomarker analysis. Findings underscore the importance of early platform selection to ensure robust, fit-for-purpose biomarker quantification for clinical pharmacology studies and regulatory submissions.
- 9 March 2026
- Published by MDPI AG in Preprints.org
Open AccessQuantitative Evaluation of VEGF in Human Plasma Using ELISA and MSD Platforms for Pharmacodynamic Assessment
Precise quantitative determination of Vascular Endothelial Growth Factor (VEGF) in human plasma is critical for pharmacodynamic (PD) evaluation of anti-VEGF therapeutics. In this study, we developed and optimized two immunoassay platforms, including the enzyme-linked immunosorbent assay (ELISA) and the Meso Scale Discovery (MSD), for estimating VEGF. A direct sandwich ELISA was validated to quantify pharmacodynamic biomarker VEGF in human plasma using the Human VEGF Quantikine Kit, demonstrating a quantification range of 62.5–2000.0 pg/mL and a sensitivity of 47.5 pg/mL. In parallel, a sandwich electrochemiluminescence (ECL) assay was developed using the V-PLEX Plus Human VEGF Kit on the MSD platform, achieving a lower quantification range of 7.7–562.0 pg/mL. Comparative analysis revealed that MSD ECL detection with Sulfo Tag labeling outperformed traditional colorimetric ELISA in terms of signal amplification and dynamic range, making it a valuable tool for PD biomarker analysis. Findings underscore the importance of early platform selection to ensure robust, fit-for-purpose biomarker quantification for clinical pharmacology studies and regulatory submissions.
- 9 February 2022
- Published by Elsevier in Journal of Chromatography B
- Vol. 1192, 123158
Corrigendum to “Bioanalytical method development and validation of highly selective and sensitive LC-MS/MS method for determination of teriparatide (parathyroid hormone fragment 1–34) in human serum through direct detection of intact teriparatide molecule” [J. Chromatogr. B 1187 (2021) 123046]
- 9 February 2022
- Published by Elsevier in Journal of Chromatography B
- Vol. 1192, 123158
Corrigendum to “Bioanalytical method development and validation of highly selective and sensitive LC-MS/MS method for determination of teriparatide (parathyroid hormone fragment 1–34) in human serum through direct detection of intact teriparatide molecule” [J. Chromatogr. B 1187 (2021) 123046]
- 1 December 2021
- Published by Elsevier in Journal of Chromatography B
- Vol. 1187, 123046
Bioanalytical method development and validation of highly selective and sensitive LC-MS/MS method for determination of teriparatide (parathyroid hormone fragment 1–34) in human serum through direct detection of intact teriparatide molecule
- 1 December 2021
- Published by Elsevier in Journal of Chromatography B
- Vol. 1187, 123046
Bioanalytical method development and validation of highly selective and sensitive LC-MS/MS method for determination of teriparatide (parathyroid hormone fragment 1–34) in human serum through direct detection of intact teriparatide molecule