Niyousha Rafeie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Niyousha Rafeie has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Elham Ahmadi
Department of Restorative Dentistry, Dental School, Tehran University of Medical Sciences, Tehran, Iran
4 shared publications - Mahdi Abbasi
Department of Restorative Dentistry, Dental School, Tehran University of Medical Sciences, Tehran, Iran
3 shared publications - Ladan Ranjbar Omrani
Department of Restorative Dentistry, Dental School, Tehran University of Medical Sciences, Tehran, Iran
2 shared publications - Aida Mohammadi
Department of Psychiatry University of Social Welfare and Rehabilitation Sciences Tehran Iran
1 shared publication - Alireza Mokhtari
Student Research Committee, Dental Faculty, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran
1 shared publication - Amirahmad Pahlavan Hoseini
Prosthodontics Department, School of Dentistry, Islamic Azad University of Medical Sciences, Tehran, Iran
1 shared publication
Latest Publications
- 1 March 2024
- Published by Bentham Science Publishers Ltd. in Current Reviews in Clinical and Experimental Pharmacology
- Vol. 19 (1) , 42-60
Effects of Drugs and Chemotherapeutic Agents on Dental Implant Osseointegration: A Narrative Review
Background: Dental implants have been one of the most popular treatments for rehabilitating individuals with single missing teeth or fully edentulous jaws since their introduction. As more implant patients are well-aged and take several medications due to various systemic conditions, clinicians should be mindful of possible drug implications on bone remodeling and osseointegration. Objective: The present study aims to study and review some desirable and some unwelcomed implications of medicine on osseointegration. Methods: A broad search for proper relevant studies were conducted in four databases, including Web of Science, Pubmed, Scopus, and Google Scholar. Results: Some commonly prescribed medicines such as nonsteroidal anti-inflammatory drugs (NSAIDs), glucocorticoids, proton pump inhibitors (PPIs), selective serotonin reuptake inhibitors (SSRIs), anticoagulants, metformin, and chemotherapeutic agents may jeopardize osseointegration. On the contrary, some therapeutic agents such as anabolic, anti-catabolic, or dual anabolic and anti-catabolic agents may enhance osseointegration and increase the treatment’s success rate. Conclusion: Systemic medications that enhance osseointegration include mineralization promoters and bone resorption inhibitors. On the other hand, medications often given to the elderly with systemic problems might interfere with osseointegration, leading to implant failure. However, to validate the provided research, more human studies with a higher level of evidence are required.
- 1 March 2024
- Published by Bentham Science Publishers Ltd. in Current Reviews in Clinical and Experimental Pharmacology
- Vol. 19 (1) , 42-60
Effects of Drugs and Chemotherapeutic Agents on Dental Implant Osseointegration: A Narrative Review
Background: Dental implants have been one of the most popular treatments for rehabilitating individuals with single missing teeth or fully edentulous jaws since their introduction. As more implant patients are well-aged and take several medications due to various systemic conditions, clinicians should be mindful of possible drug implications on bone remodeling and osseointegration. Objective: The present study aims to study and review some desirable and some unwelcomed implications of medicine on osseointegration. Methods: A broad search for proper relevant studies were conducted in four databases, including Web of Science, Pubmed, Scopus, and Google Scholar. Results: Some commonly prescribed medicines such as nonsteroidal anti-inflammatory drugs (NSAIDs), glucocorticoids, proton pump inhibitors (PPIs), selective serotonin reuptake inhibitors (SSRIs), anticoagulants, metformin, and chemotherapeutic agents may jeopardize osseointegration. On the contrary, some therapeutic agents such as anabolic, anti-catabolic, or dual anabolic and anti-catabolic agents may enhance osseointegration and increase the treatment’s success rate. Conclusion: Systemic medications that enhance osseointegration include mineralization promoters and bone resorption inhibitors. On the other hand, medications often given to the elderly with systemic problems might interfere with osseointegration, leading to implant failure. However, to validate the provided research, more human studies with a higher level of evidence are required.
- Open Access
- 23 June 2023
- Published by Springer Nature in BMC Oral Health
- Vol. 23 (1) , 1-8
Evaluation of diagnostic accuracy of CBCT and intraoral radiography for proximal caries detection in the presence of different dental restoration materials
Purpose: This study aimed to assess the diagnostic accuracy of cone-beam computed tomography (CBCT) and digital intraoral radiography for the detection of proximal caries adjacent to amalgam, e.max porcelain, and metal-ceramic restorations (MCRs). Materials and methods: Parallel intraoral radiographs were obtained from 40 posterior teeth using PSP sensors. To obtain CBCT scans, the teeth were first radiographed alone, and were then positioned next to a tooth with an amalgam restoration, MCR, and e.max porcelain crown, and radiographed again. Two blinded observers scored radiographs using a four-point scale (0: absence of proximal caries, 1: enamel caries, 2: carious lesion extending to the outer half of dentin, 3: carious lesion extending to the inner half of dentin). Tooth sections were made, and the grade of caries was determined under a light microscope at x12 magnification. The sensitivity, specificity, and accuracy of CBCT and intraoral radiographs were then calculated. Results: Artifact-free CBCT scans and intraoral radiographs had the highest diagnostic accuracy (0.826 and 0.657, respectively) while CBCT images of the teeth next to the amalgam restorations (0.526) had the lowest accuracy. The diagnostic accuracy of CBCT images of the teeth next to the porcelain crowns and MCRs was 0.613 and 0.601, respectively. Conclusion: Artifact-free CBCT images had higher diagnostic accuracy than intraoral radiography for the detection of all grades of proximal caries. The diagnostic accuracy of CBCT images of teeth adjacent to amalgam, porcelain, and MCRs was lower compared to intraoral radiographs and artifact-free CBCT images.
- 23 June 2023
- Published by Springer Nature in BMC Oral Health
- Vol. 23 (1) , 1-8
Open AccessEvaluation of diagnostic accuracy of CBCT and intraoral radiography for proximal caries detection in the presence of different dental restoration materials
Purpose: This study aimed to assess the diagnostic accuracy of cone-beam computed tomography (CBCT) and digital intraoral radiography for the detection of proximal caries adjacent to amalgam, e.max porcelain, and metal-ceramic restorations (MCRs). Materials and methods: Parallel intraoral radiographs were obtained from 40 posterior teeth using PSP sensors. To obtain CBCT scans, the teeth were first radiographed alone, and were then positioned next to a tooth with an amalgam restoration, MCR, and e.max porcelain crown, and radiographed again. Two blinded observers scored radiographs using a four-point scale (0: absence of proximal caries, 1: enamel caries, 2: carious lesion extending to the outer half of dentin, 3: carious lesion extending to the inner half of dentin). Tooth sections were made, and the grade of caries was determined under a light microscope at x12 magnification. The sensitivity, specificity, and accuracy of CBCT and intraoral radiographs were then calculated. Results: Artifact-free CBCT scans and intraoral radiographs had the highest diagnostic accuracy (0.826 and 0.657, respectively) while CBCT images of the teeth next to the amalgam restorations (0.526) had the lowest accuracy. The diagnostic accuracy of CBCT images of the teeth next to the porcelain crowns and MCRs was 0.613 and 0.601, respectively. Conclusion: Artifact-free CBCT images had higher diagnostic accuracy than intraoral radiography for the detection of all grades of proximal caries. The diagnostic accuracy of CBCT images of teeth adjacent to amalgam, porcelain, and MCRs was lower compared to intraoral radiographs and artifact-free CBCT images.
- Open Access
- 12 May 2023
- Published by Wiley in International Journal of Dentistry
- Vol. 2023, 1-7
Effect of Different Bleaching Methods on Monomer Release from Aged Microhybrid and Nanohybrid Resin Composites
Introduction. Recently, the application of laser-assisted bleaching has increased in dental practice. This method might affect the physical and chemical properties of resin composite and its monomer release. This study aimed to evaluate the effect of in-office, at-home, and laser-assisted bleaching on the monomer release (bisphenol A diglycidyl dimethacrylate (BisGMA), triethylene glycol dimethacrylate (TEGDMA), and urethane dimethacrylate (UDMA)) from aged nanohybrid (Grandio, Voco) and microhybrid (Clearfil AP-X Esthetics, Kuraray) resin composites. Methods. Thirty-two samples of each composite were prepared. The samples underwent aging procedure with UV light at 65C for 100hr. The samples were divided into 4 groups: OB: conventional in-office bleaching with Opalescence Boost PF 40gel; HB: home bleaching with Opalescence PF 15 gel; LB: bleaching with JW Power bleaching gel followed by diode laser application; and C: control group without bleaching. Then, the samples were immersed in a solution containing 75 ethanol25 distilled water. The medium was renewed after 8, 16, 24hr, and 7 days and was analyzed using high-performance liquid chromatography method to evaluate the monomer release. The data were analyzed using Two-way ANOVA and Post hoc Tukey test. Results. The bleaching method had no effect on TEGDMA and BisGMA release in both composites while it affected UDMA release in nanohybrid composite; UDMA release was significantly higher in LB compared to control and also higher in OB and LB compared to HB. No difference was observed in the microhybrid composite in this regard. Conclusion. Laser-assisted bleaching did not affect monomer release from microhybrid composite while it increased UDMA release from nanohybrid composite. The bleaching method had no effect on TEGDMA and BisGMA release.
- 12 May 2023
- Published by Wiley in International Journal of Dentistry
- Vol. 2023, 1-7
Open AccessEffect of Different Bleaching Methods on Monomer Release from Aged Microhybrid and Nanohybrid Resin Composites
Introduction. Recently, the application of laser-assisted bleaching has increased in dental practice. This method might affect the physical and chemical properties of resin composite and its monomer release. This study aimed to evaluate the effect of in-office, at-home, and laser-assisted bleaching on the monomer release (bisphenol A diglycidyl dimethacrylate (BisGMA), triethylene glycol dimethacrylate (TEGDMA), and urethane dimethacrylate (UDMA)) from aged nanohybrid (Grandio, Voco) and microhybrid (Clearfil AP-X Esthetics, Kuraray) resin composites. Methods. Thirty-two samples of each composite were prepared. The samples underwent aging procedure with UV light at 65C for 100hr. The samples were divided into 4 groups: OB: conventional in-office bleaching with Opalescence Boost PF 40gel; HB: home bleaching with Opalescence PF 15 gel; LB: bleaching with JW Power bleaching gel followed by diode laser application; and C: control group without bleaching. Then, the samples were immersed in a solution containing 75 ethanol25 distilled water. The medium was renewed after 8, 16, 24hr, and 7 days and was analyzed using high-performance liquid chromatography method to evaluate the monomer release. The data were analyzed using Two-way ANOVA and Post hoc Tukey test. Results. The bleaching method had no effect on TEGDMA and BisGMA release in both composites while it affected UDMA release in nanohybrid composite; UDMA release was significantly higher in LB compared to control and also higher in OB and LB compared to HB. No difference was observed in the microhybrid composite in this regard. Conclusion. Laser-assisted bleaching did not affect monomer release from microhybrid composite while it increased UDMA release from nanohybrid composite. The bleaching method had no effect on TEGDMA and BisGMA release.
- Open Access
- 23 November 2022
- Published by Wiley in International Journal of Dentistry
- Vol. 2022 (1) , 3399120
Combined Minimally Invasive Treatment of Teeth Discoloration Caused by Occupational Exposure to Bronze Alloy
Recently, dental bleaching has been frequently sought by patients to improve the appearance and color of the teeth. Among various treatment options, in‐office bleaching is commonly preferred by patients with severely discolored teeth due to its fast aesthetic results. In addition, other pretreatment methods, such as air‐powder polishing, have been reported to increase the efficacy of bleaching treatment. Compared to other causes of tooth discoloration, occupational tooth discoloration caused by bronze alloy and further treatment have not been sufficiently documented in the literature. In the present case report, we explain a case of tooth discoloration following exposure to a bronze alloy and a conservative clinical approach used for the management of tooth discoloration. A 15‐year‐old male patient who worked in a foundry was presented with tooth discoloration. At the first session, a rubber‐cap prophylaxis was performed. After one week, air‐powder polishing was used to remove the remaining stains. Finally, at the third session, two cycles of bleaching were performed using hydrogen peroxide gel 35%, each for 20 minutes. Photographs were taken at the end of each session and used for visual evaluation. The final result was aesthetically satisfactory.
- 23 November 2022
- Published by Wiley in International Journal of Dentistry
- Vol. 2022 (1) , 3399120
Open AccessCombined Minimally Invasive Treatment of Teeth Discoloration Caused by Occupational Exposure to Bronze Alloy
Recently, dental bleaching has been frequently sought by patients to improve the appearance and color of the teeth. Among various treatment options, in‐office bleaching is commonly preferred by patients with severely discolored teeth due to its fast aesthetic results. In addition, other pretreatment methods, such as air‐powder polishing, have been reported to increase the efficacy of bleaching treatment. Compared to other causes of tooth discoloration, occupational tooth discoloration caused by bronze alloy and further treatment have not been sufficiently documented in the literature. In the present case report, we explain a case of tooth discoloration following exposure to a bronze alloy and a conservative clinical approach used for the management of tooth discoloration. A 15‐year‐old male patient who worked in a foundry was presented with tooth discoloration. At the first session, a rubber‐cap prophylaxis was performed. After one week, air‐powder polishing was used to remove the remaining stains. Finally, at the third session, two cycles of bleaching were performed using hydrogen peroxide gel 35%, each for 20 minutes. Photographs were taken at the end of each session and used for visual evaluation. The final result was aesthetically satisfactory.
- Open Access
- 21 August 2022
- Published by Springer Nature in BMC Oral Health
- Vol. 22 (1) , 1-7
In vitro attrition wear resistance of four types of paste-like bulk-fill composite resins
Background: Recently, the application of bulk-fill composite resins has increased significantly. Attrition wear and the consequently increased surface roughness of composite resins are among the causes of restoration failure in the posterior teeth. This study aimed to compare the attrition wear and surface roughness of four types of bulk-fill composite resins compared to a conventional composite resin. Methods: EverX-Posterior, X-tra fil, SonicFill 2, and Filtek Bulk-Fill composites (bulk-fill) and Z250 composite (conventional resin composite) were evaluated. Thirty cylindrical specimens (n = 6) were weighed and monitored for 24 h until their weight was stabilized. The primary surface roughness of the specimens was measured by a profilometer. The specimens were then subjected to attrition wear in a chewing simulator. Next, the specimens were weighed, and the surface roughness was measured again. Data were analyzed by one-way ANOVA and Tukey’s post-hoc test at P < 0.05 significance level. Results: According to one-way ANOVA, the difference in weight loss was significant among the groups (P = 0.004) but the difference in surface roughness of the groups was not significant after the attrition wear (P > 0.05). Tukey’s post-hoc test showed that the weight loss of bulk-fill composites was not significantly different from that of Z250 conventional composite after the attrition wear (P > 0.05). Conclusion: Within the limitations of this study, it appears that the tested bulk-fill composite resins are comparable to the conventional composite regarding their attrition wear, increased surface roughness, and weight loss.
- 21 August 2022
- Published by Springer Nature in BMC Oral Health
- Vol. 22 (1) , 1-7
Open AccessIn vitro attrition wear resistance of four types of paste-like bulk-fill composite resins
Background: Recently, the application of bulk-fill composite resins has increased significantly. Attrition wear and the consequently increased surface roughness of composite resins are among the causes of restoration failure in the posterior teeth. This study aimed to compare the attrition wear and surface roughness of four types of bulk-fill composite resins compared to a conventional composite resin. Methods: EverX-Posterior, X-tra fil, SonicFill 2, and Filtek Bulk-Fill composites (bulk-fill) and Z250 composite (conventional resin composite) were evaluated. Thirty cylindrical specimens (n = 6) were weighed and monitored for 24 h until their weight was stabilized. The primary surface roughness of the specimens was measured by a profilometer. The specimens were then subjected to attrition wear in a chewing simulator. Next, the specimens were weighed, and the surface roughness was measured again. Data were analyzed by one-way ANOVA and Tukey’s post-hoc test at P < 0.05 significance level. Results: According to one-way ANOVA, the difference in weight loss was significant among the groups (P = 0.004) but the difference in surface roughness of the groups was not significant after the attrition wear (P > 0.05). Tukey’s post-hoc test showed that the weight loss of bulk-fill composites was not significantly different from that of Z250 conventional composite after the attrition wear (P > 0.05). Conclusion: Within the limitations of this study, it appears that the tested bulk-fill composite resins are comparable to the conventional composite regarding their attrition wear, increased surface roughness, and weight loss.
- Open Access
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Pesquisa Brasileira em Odontopediatria e Clínica Integrada
- Vol. 22
Cytotoxicity Comparison of a Calcium Silicate-Based Resin Cement versus Conventional Self-Adhesive Resin Cement and a Resin-Modified Glass Ionomer: Cell Viability Analysis
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Pesquisa Brasileira em Odontopediatria e Clínica Integrada
- Vol. 22
Open AccessCytotoxicity Comparison of a Calcium Silicate-Based Resin Cement versus Conventional Self-Adhesive Resin Cement and a Resin-Modified Glass Ionomer: Cell Viability Analysis
- Open Access
- 1 January 2022
- Published by Wiley in International Journal of Dentistry
- Vol. 2022 (1) , 6831864
Effect of Helium Plasma Exposure on Wettability and Shear Bond Strength between the Zirconia Core and Feldspathic Veneering Ceramic: An In Vitro Study
Introduction. The present study aimed to evaluate the effect of helium plasma treatment on the wettability of zirconia surface and on the shear bond strength between the dental zirconia core and feldspathic veneering ceramic. Methods. 128 zirconia specimens were prepared, polished, and then divided into four groups: control, Zr, FC, and Zr/FC. In Zr and Zr/FC groups, the zirconia blocks were treated by helium plasma for 60 s. In FC and Zr/FC, the feldspathic ceramic powder received 60 s of plasma treatment. Then, the feldspathic powder was applied on the zirconia blocks. Half of the specimens in each group were sintered in a tube furnace, and the contact angle between the zirconia core and feldspathic ceramic was measured at different time intervals. The other half were sintered in a ceramic furnace and then subjected to thermocycling. The shear bond strength was measured using a universal testing machine. The failure mode was assessed using a stereomicroscope. Data were analyzed by one‐way ANOVA test, and the statistical significance was considered less than 0.05. Results. There was no significant difference in the mean contact angle and the shear bond strength values of the experimental groups (P > 0.05). The mean contact angle decreased significantly in all groups over time (P < 0.001). The modes of failure were predominantly mixed in all groups. Conclusion. The helium plasma applied on either dental zirconia core or feldspathic ceramic powder could not improve the zirconia surface wettability and the shear bond strength between the two ceramics.
- 1 January 2022
- Published by Wiley in International Journal of Dentistry
- Vol. 2022 (1) , 6831864
Open AccessEffect of Helium Plasma Exposure on Wettability and Shear Bond Strength between the Zirconia Core and Feldspathic Veneering Ceramic: An In Vitro Study
Introduction. The present study aimed to evaluate the effect of helium plasma treatment on the wettability of zirconia surface and on the shear bond strength between the dental zirconia core and feldspathic veneering ceramic. Methods. 128 zirconia specimens were prepared, polished, and then divided into four groups: control, Zr, FC, and Zr/FC. In Zr and Zr/FC groups, the zirconia blocks were treated by helium plasma for 60 s. In FC and Zr/FC, the feldspathic ceramic powder received 60 s of plasma treatment. Then, the feldspathic powder was applied on the zirconia blocks. Half of the specimens in each group were sintered in a tube furnace, and the contact angle between the zirconia core and feldspathic ceramic was measured at different time intervals. The other half were sintered in a ceramic furnace and then subjected to thermocycling. The shear bond strength was measured using a universal testing machine. The failure mode was assessed using a stereomicroscope. Data were analyzed by one‐way ANOVA test, and the statistical significance was considered less than 0.05. Results. There was no significant difference in the mean contact angle and the shear bond strength values of the experimental groups (P > 0.05). The mean contact angle decreased significantly in all groups over time (P < 0.001). The modes of failure were predominantly mixed in all groups. Conclusion. The helium plasma applied on either dental zirconia core or feldspathic ceramic powder could not improve the zirconia surface wettability and the shear bond strength between the two ceramics.
- Open Access
- 27 July 2021
- Published by Wiley in International Journal of Dentistry
- Vol. 2021, 1-8
Effect of Cold Atmospheric Pressure Plasma Coupled with Resin-Containing and Xylitol-Containing Fluoride Varnishes on Enamel Erosion
Purpose. Considering the suggested advantages of cold atmospheric plasma (CAP) in increasing the fluoride uptake by the enamel, this study aimed to assess enamel erosion following the application of helium CAP and two types of fluoride varnishes. Methods. The microhardness of 70 bovine enamel specimens was measured using a Vickers hardness tester. The specimens were randomly divided into 7 groups (n=10): control, CAP (P), resin-containing fluoride varnish (RF), CAP+resin-containing fluoride varnish (PRF), fluoride varnish (F), CAP+fluoride varnish (PF), and erosion (E). The specimens in the control and erosion groups did not receive CAP or fluoride varnish. All specimens underwent erosive challenge 4 times/day using hydrochloric acid and artificial saliva except for the control specimens that remained in distilled water during the course of the study. After 5days of erosive challenge, microhardness was measured again, and the percentage of microhardness change was calculated. Surface roughness of two specimens in each group was assessed by atomic force microscopy (AFM). Data were analyzed using one-way ANOVA followed by Tamhanes post-hoc test. Results. The percentage of microhardness change in all groups was significantly higher than that of the control group. All groups showed significantly lower percentage of microhardness change compared with the E group except for the P group; no significant difference was noted in microhardness change of P and E groups. Other experimental groups had no significant difference with each other. Surface roughness was the highest in PRF and the lowest in the F group. Conclusion. CAP application had no significant effect on increasing the enamel resistance to erosion. However, enamel resistance to erosion increased significantly after fluoride varnish application alone or fluoride varnish application combined with CAP. No significant difference was noted between the two types of varnishes in this regard. CAP increased the surface roughness while fluoride varnish application alone decreased the roughness.
- 27 July 2021
- Published by Wiley in International Journal of Dentistry
- Vol. 2021, 1-8
Open AccessEffect of Cold Atmospheric Pressure Plasma Coupled with Resin-Containing and Xylitol-Containing Fluoride Varnishes on Enamel Erosion
Purpose. Considering the suggested advantages of cold atmospheric plasma (CAP) in increasing the fluoride uptake by the enamel, this study aimed to assess enamel erosion following the application of helium CAP and two types of fluoride varnishes. Methods. The microhardness of 70 bovine enamel specimens was measured using a Vickers hardness tester. The specimens were randomly divided into 7 groups (n=10): control, CAP (P), resin-containing fluoride varnish (RF), CAP+resin-containing fluoride varnish (PRF), fluoride varnish (F), CAP+fluoride varnish (PF), and erosion (E). The specimens in the control and erosion groups did not receive CAP or fluoride varnish. All specimens underwent erosive challenge 4 times/day using hydrochloric acid and artificial saliva except for the control specimens that remained in distilled water during the course of the study. After 5days of erosive challenge, microhardness was measured again, and the percentage of microhardness change was calculated. Surface roughness of two specimens in each group was assessed by atomic force microscopy (AFM). Data were analyzed using one-way ANOVA followed by Tamhanes post-hoc test. Results. The percentage of microhardness change in all groups was significantly higher than that of the control group. All groups showed significantly lower percentage of microhardness change compared with the E group except for the P group; no significant difference was noted in microhardness change of P and E groups. Other experimental groups had no significant difference with each other. Surface roughness was the highest in PRF and the lowest in the F group. Conclusion. CAP application had no significant effect on increasing the enamel resistance to erosion. However, enamel resistance to erosion increased significantly after fluoride varnish application alone or fluoride varnish application combined with CAP. No significant difference was noted between the two types of varnishes in this regard. CAP increased the surface roughness while fluoride varnish application alone decreased the roughness.