Thai Akasaka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Thai Akasaka has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Kaori Togashi
Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan
3 shared publications - Koji Fujimoto
Advanced Imaging in Medical Magnetic Resonance Kyoto University Graduate School of Medicine Kyoto Japan
3 shared publications - Tomohisa Okada
Human Brain Research Center, Graduate School of Medicine Kyoto University Kyoto Japan
2 shared publications - Akihiro Furuta
The Department of Radiology, Japanese Red Cross Society Osaka Red Cross Hospital, 5-30, Fudegasakicho, Tennouji-ku, Osaka, Osaka, 543-8555, Japan.
1 shared publication Akira Yamamoto
Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, Kyoto, Japan
1 shared publication- Ayako Ono
Department of Radiology, Tenri Hospital
1 shared publication
Latest Publications
- 1 July 2022
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 57 (3) , 882-883
Editorial for “Fully Automated MRI Segmentation and Volumetric Measurement of Intracranial Meningioma Using Deep Learning”
- 1 July 2022
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 57 (3) , 882-883
Editorial for “Fully Automated MRI Segmentation and Volumetric Measurement of Intracranial Meningioma Using Deep Learning”
- 29 July 2021
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 55 (1) , 152-153
Editorial for “Longitudinal Sodium MRI of Multiple Sclerosis Lesions: Is There Added Value of Sodium Inversion Recovery MRI?”
- 29 July 2021
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 55 (1) , 152-153
Editorial for “Longitudinal Sodium MRI of Multiple Sclerosis Lesions: Is There Added Value of Sodium Inversion Recovery MRI?”
- Open Access
- 6 October 2020
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 33 (6) , 1543-1553
Adaptive Voxel Matching for Temporal CT Subtraction
Temporal subtraction (TS) technique calculates a subtraction image between a pair of registered images acquired from the same patient at different times. Previous studies have shown that TS is effective for visualizing pathological changes over time; therefore, TS should be a useful tool for radiologists. However, artifacts caused by partial volume effects degrade the quality of thick-slice subtraction images, even with accurate image registration. Here, we propose a subtraction method for reducing artifacts in thick-slice images and discuss its implementation in high-speed processing. The proposed method is based on voxel matching, which reduces artifacts by considering gaps in discretized positions of two images in subtraction calculations. There are two different features between the proposed method and conventional voxel matching: (1) the size of a searching region to reduce artifacts is determined based on discretized position gaps between images and (2) the searching region is set on both images for symmetrical subtraction. The proposed method is implemented by adopting an accelerated subtraction calculation method that exploit the nature of liner interpolation for calculating the signal value at a point among discretized positions. We quantitatively evaluated the proposed method using synthetic data and qualitatively using clinical data interpreted by radiologists. The evaluation showed that the proposed method was superior to conventional methods. Moreover, the processing speed using the proposed method was almost unchanged from that of the conventional methods. The results indicate that the proposed method can improve the quality of subtraction images acquired from thick-slice images.
- 6 October 2020
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 33 (6) , 1543-1553
Open AccessAdaptive Voxel Matching for Temporal CT Subtraction
Temporal subtraction (TS) technique calculates a subtraction image between a pair of registered images acquired from the same patient at different times. Previous studies have shown that TS is effective for visualizing pathological changes over time; therefore, TS should be a useful tool for radiologists. However, artifacts caused by partial volume effects degrade the quality of thick-slice subtraction images, even with accurate image registration. Here, we propose a subtraction method for reducing artifacts in thick-slice images and discuss its implementation in high-speed processing. The proposed method is based on voxel matching, which reduces artifacts by considering gaps in discretized positions of two images in subtraction calculations. There are two different features between the proposed method and conventional voxel matching: (1) the size of a searching region to reduce artifacts is determined based on discretized position gaps between images and (2) the searching region is set on both images for symmetrical subtraction. The proposed method is implemented by adopting an accelerated subtraction calculation method that exploit the nature of liner interpolation for calculating the signal value at a point among discretized positions. We quantitatively evaluated the proposed method using synthetic data and qualitatively using clinical data interpreted by radiologists. The evaluation showed that the proposed method was superior to conventional methods. Moreover, the processing speed using the proposed method was almost unchanged from that of the conventional methods. The results indicate that the proposed method can improve the quality of subtraction images acquired from thick-slice images.
- Open Access
Diffusion Tensor Model links to Neurite Orientation Dispersion and Density Imaging at high b-value in Cerebral Cortical Gray Matter
Diffusion tensor imaging (DTI) and neurite orientation dispersion and density imaging (NODDI) are widely used models to infer microstructural features in the brain from diffusion-weighted MRI. Several studies have recently applied both models to increase sensitivity to biological changes, however, it remains uncertain how these measures are associated. Here we show that cortical distributions of DTI and NODDI are associated depending on the choice of b-value, a factor reflecting strength of diffusion weighting gradient. We analyzed a combination of high, intermediate and low b-value data of multi-shell diffusion-weighted MRI (dMRI) in healthy 456 subjects of the Human Connectome Project using NODDI, DTI and a mathematical conversion from DTI to NODDI. Cortical distributions of DTI and DTI-derived NODDI metrics were remarkably associated with those in NODDI, particularly when applied highly diffusion-weighted data (b-value =3000 sec/mm 2 ). This was supported by simulation analysis, which revealed that DTI-derived parameters with lower b-value datasets suffered from errors due to heterogeneity of cerebrospinal fluid fraction and partial volume. These findings suggest that high b-value DTI redundantly parallels with NODDI-based cortical neurite measures, but the conventional low b-value DTI does not reasonably characterize cortical microarchitecture.
Open AccessDiffusion Tensor Model links to Neurite Orientation Dispersion and Density Imaging at high b-value in Cerebral Cortical Gray Matter
Diffusion tensor imaging (DTI) and neurite orientation dispersion and density imaging (NODDI) are widely used models to infer microstructural features in the brain from diffusion-weighted MRI. Several studies have recently applied both models to increase sensitivity to biological changes, however, it remains uncertain how these measures are associated. Here we show that cortical distributions of DTI and NODDI are associated depending on the choice of b-value, a factor reflecting strength of diffusion weighting gradient. We analyzed a combination of high, intermediate and low b-value data of multi-shell diffusion-weighted MRI (dMRI) in healthy 456 subjects of the Human Connectome Project using NODDI, DTI and a mathematical conversion from DTI to NODDI. Cortical distributions of DTI and DTI-derived NODDI metrics were remarkably associated with those in NODDI, particularly when applied highly diffusion-weighted data (b-value =3000 sec/mm 2 ). This was supported by simulation analysis, which revealed that DTI-derived parameters with lower b-value datasets suffered from errors due to heterogeneity of cerebrospinal fluid fraction and partial volume. These findings suggest that high b-value DTI redundantly parallels with NODDI-based cortical neurite measures, but the conventional low b-value DTI does not reasonably characterize cortical microarchitecture.
- 1 November 2017
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 43, 42-47
Non-contrast-enhanced 3D MR portography within a breath-hold using compressed sensing acceleration: A prospective noninferiority study
- 1 November 2017
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 43, 42-47
Non-contrast-enhanced 3D MR portography within a breath-hold using compressed sensing acceleration: A prospective noninferiority study
- Open Access
- 8 January 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (1) , e0146548
Optimization of Regularization Parameters in Compressed Sensing of Magnetic Resonance Angiography: Can Statistical Image Metrics Mimic Radiologists' Perception?
In Compressed Sensing (CS) of MRI, optimization of the regularization parameters is not a trivial task. We aimed to establish a method that could determine the optimal weights for regularization parameters in CS of time-of-flight MR angiography (TOF-MRA) by comparing various image metrics with radiologists’ visual evaluation. TOF-MRA of a healthy volunteer was scanned using a 3T-MR system. Images were reconstructed by CS from retrospectively under-sampled data by varying the weights for the L1 norm of wavelet coefficients and that of total variation. The reconstructed images were evaluated both quantitatively by statistical image metrics including structural similarity (SSIM), scale invariant feature transform (SIFT) and contrast-to-noise ratio (CNR), and qualitatively by radiologists’ scoring. The results of quantitative metrics and qualitative scorings were compared. SSIM and SIFT in conjunction with brain masks and CNR of artery-to-parenchyma correlated very well with radiologists’ visual evaluation. By carefully selecting a region to measure, we have shown that statistical image metrics can reflect radiologists’ visual evaluation, thus enabling an appropriate optimization of regularization parameters for CS.
- 8 January 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (1) , e0146548
Open AccessOptimization of Regularization Parameters in Compressed Sensing of Magnetic Resonance Angiography: Can Statistical Image Metrics Mimic Radiologists' Perception?
In Compressed Sensing (CS) of MRI, optimization of the regularization parameters is not a trivial task. We aimed to establish a method that could determine the optimal weights for regularization parameters in CS of time-of-flight MR angiography (TOF-MRA) by comparing various image metrics with radiologists’ visual evaluation. TOF-MRA of a healthy volunteer was scanned using a 3T-MR system. Images were reconstructed by CS from retrospectively under-sampled data by varying the weights for the L1 norm of wavelet coefficients and that of total variation. The reconstructed images were evaluated both quantitatively by statistical image metrics including structural similarity (SSIM), scale invariant feature transform (SIFT) and contrast-to-noise ratio (CNR), and qualitatively by radiologists’ scoring. The results of quantitative metrics and qualitative scorings were compared. SSIM and SIFT in conjunction with brain masks and CNR of artery-to-parenchyma correlated very well with radiologists’ visual evaluation. By carefully selecting a region to measure, we have shown that statistical image metrics can reflect radiologists’ visual evaluation, thus enabling an appropriate optimization of regularization parameters for CS.
- 1 June 2015
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 88 (1050) , 20150117
The Dixon technique and the frequency-selective fat suppression technique in three-dimensionalT1weighted MRI of the liver: a comparison of contrast-to-noise ratios of hepatocellular carcinomas-to-liver
The use of three-dimensional T1 weighted gradient echo sequences such as the Dixon technique and the frequency-selective fat suppression (FS) technique is currently widely accepted method in MRI examinations of the liver. To assess the image qualities of the Dixon technique and the frequency-selective FS technique, the contrast-to-noise ratios (CNRs) of hepatocellular carcinoma (HCC)-to-liver and fat-to-liver were compared between the two techniques in the hepatobiliary phase (HBP) following administration of gadolinium-ethoxybenzyl-diethylenetriamine penta-acetic acid. MR images of 59 patients with a total of 86 HCCs were retrospectively evaluated. Images were consecutively obtained with the Dixon and frequency-selective FS methods in the HBP and their CNRs of HCC-to-liver and fat-to-liver were compared. CNRs and contrast ratios were calculated by the mean value of the liver parenchyma, HCC, fat and standard deviation of the liver parenchyma. The Wilcoxon signed-ranks test was used for statistical analysis. The median CNRs for the frequency-selective FS and Dixon techniques of HCC-to-liver were 4.3 and 5.4 (p < 0.01), mesenteric fat-to-liver were 9.9 and 12.8 (p < 0.01) and subcutaneous fat-to-liver were 9.9 and 13.2 (p < 0.01), respectively. The Dixon technique yielded higher CNRs of HCC-to-liver than that of the frequency-selective FS technique. There are a limited number of reports on quantitative analysis of the image qualities of the Dixon technique and the frequency-selective FS technique, particularly within the same patient and examination.
- 1 June 2015
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 88 (1050) , 20150117
The Dixon technique and the frequency-selective fat suppression technique in three-dimensionalT1weighted MRI of the liver: a comparison of contrast-to-noise ratios of hepatocellular carcinomas-to-liver
The use of three-dimensional T1 weighted gradient echo sequences such as the Dixon technique and the frequency-selective fat suppression (FS) technique is currently widely accepted method in MRI examinations of the liver. To assess the image qualities of the Dixon technique and the frequency-selective FS technique, the contrast-to-noise ratios (CNRs) of hepatocellular carcinoma (HCC)-to-liver and fat-to-liver were compared between the two techniques in the hepatobiliary phase (HBP) following administration of gadolinium-ethoxybenzyl-diethylenetriamine penta-acetic acid. MR images of 59 patients with a total of 86 HCCs were retrospectively evaluated. Images were consecutively obtained with the Dixon and frequency-selective FS methods in the HBP and their CNRs of HCC-to-liver and fat-to-liver were compared. CNRs and contrast ratios were calculated by the mean value of the liver parenchyma, HCC, fat and standard deviation of the liver parenchyma. The Wilcoxon signed-ranks test was used for statistical analysis. The median CNRs for the frequency-selective FS and Dixon techniques of HCC-to-liver were 4.3 and 5.4 (p < 0.01), mesenteric fat-to-liver were 9.9 and 12.8 (p < 0.01) and subcutaneous fat-to-liver were 9.9 and 13.2 (p < 0.01), respectively. The Dixon technique yielded higher CNRs of HCC-to-liver than that of the frequency-selective FS technique. There are a limited number of reports on quantitative analysis of the image qualities of the Dixon technique and the frequency-selective FS technique, particularly within the same patient and examination.