T. David Tarity
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
T. David Tarity has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- William Xiang
Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, NY
4 shared publications Ioannis Gkiatas
Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY
3 shared publicationsPeter K. Sculco
Stavros Niarchos Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA
3 shared publications- Peter Keyes Sculco
Complex Joint Reconstruction Center, Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery New York New York USA
3 shared publications - Alberto V. Carli
Hospital for Special Surgery, New York, NY
2 shared publications - Christopher Wynne Jones
Department of Orthopaedic Surgery, Fremantle and Fiona Stanley Hospitals, Perth, Australia
2 shared publications
Latest Publications
- Open Access
- 17 February 2023
- Published by Elsevier in Arthroplasty Today
- Vol. 20, 101110
Early Femoral Insufficiency Fractures After Primary Total Knee Arthroplasty
- 17 February 2023
- Published by Elsevier in Arthroplasty Today
- Vol. 20, 101110
Open AccessEarly Femoral Insufficiency Fractures After Primary Total Knee Arthroplasty
- 1 August 2022
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 37 (8) , S964-S970
Extended Trochanteric Osteotomy Closure Performed Before or After Canal Preparation and Stem Impaction Does Not Affect Axial Stability
- 1 August 2022
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 37 (8) , S964-S970
Extended Trochanteric Osteotomy Closure Performed Before or After Canal Preparation and Stem Impaction Does Not Affect Axial Stability
- Open Access
- 2 March 2022
- Published by Elsevier in Arthroplasty Today
- Vol. 14, 90-95
Do Antibiotic-Loaded Calcium Sulfate Beads Improve Outcomes After Debridement, Antibiotics, and Implant Retention? A Matched Cohort Study
- 2 March 2022
- Published by Elsevier in Arthroplasty Today
- Vol. 14, 90-95
Open AccessDo Antibiotic-Loaded Calcium Sulfate Beads Improve Outcomes After Debridement, Antibiotics, and Implant Retention? A Matched Cohort Study
- 1 November 2021
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 36 (11) , 3741-3749
Irrigation and Debridement With Implant Retention: Does Chronicity of Symptoms Matter?
- 1 November 2021
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 36 (11) , 3741-3749
Irrigation and Debridement With Implant Retention: Does Chronicity of Symptoms Matter?
- 1 October 2021
- Published by Wolters Kluwer Health in JBJS Essential Surgical Techniques
- Vol. 11 (4)
Rotating Hinge Revision Total Knee Arthroplasty for Severe Arthrofibrosis
Background: Stiffness following total knee arthroplasty is a challenging complication for both the patient and surgeon, with an incidence that ranges from 1% to 13% 1 . There are several correctable mechanical causes for stiffness including malposition, malalignment, overstuffing, aseptic loosening, patella baja, and heterotopic ossification 2 . Idiopathic stiffness is often termed arthrofibrosis and is more difficult to treat 1 . Once patients have exhausted nonoperative options, including physical therapy and manipulation under anesthesia, revision surgery may be considered. Rotating hinge revision total knee arthroplasty has been shown to be an effective surgical treatment for severe arthrofibrosis. Description: First, remove all soft-tissue and osseous sources of stiffness and adequately expose the knee, then remove all previous components. Create a stable and balanced extension gap, and, conversely, a relatively loose flexion gap, which allows for a substantial increase in range of motion. Then, in order to prevent instability in flexion, a rotating hinge prosthesis is utilized, which allows for appropriate kinematic motion despite gap imbalance. Additional steps to regain flexion include medial and lateral distal femoral partial condylectomies, as well as patellar component revision. Alternatives: The first line of treatment for stiffness following total knee arthroplasty is nonoperative and is mainly focused on physical therapy 3 . Manipulation under anesthesia can also be performed within the first 12 weeks postoperatively 3 . Surgical treatments can include arthroscopic debridement as well as open debridement with possible polyethylene liner exchange. If there is a mechanical cause for stiffness, then this should also be addressed surgically. For cases of arthrofibrosis without a clear mechanical etiology or for cases in which the above treatment has failed, complete revision of the femoral and tibial components should be considered 3 . An alternative option to the technique proposed here is to utilize a varus-valgus constrained implant. Rationale: Revision with a hinged implant allows for a more aggressive approach to regaining motion, as compared with all other surgical alternatives. By revising all components, the surgeon is able to remove all sources of stiffness and reconstruct the knee until as much range of motion as possible is achieved. Unfortunately, even with balanced extension and flexion gaps, refractory stiffness is common. A solution for this residual stiffness is to unbalance the gaps and create a loose flexion gap. By doing so, the surgeon is advised to switch to a hinged implant to create a kinematically balanced knee. Any other revision implant, such as a varus-valgus constrained implant, would risk flexion instability. Expected Outcomes: Several studies have examined the use of revision total knee arthroplasty with a hinged implant for arthrofibrosis and have showed substantial improvements in knee range of motion. Bingham et al. showed that the rotating hinge group had a 20° improvement in range of motion (p = 0.048) 1 . Hermans et al. found a 35.8° flexion gain in the hinge group compared with a 14.2° flexion gain in the varus-valgus constrained group (p = 0.0002) 4 . van Rensch et al. found a median gain of 45° of range of motion 5 . Patients should be aware that this procedure involving the use of a hinged implant has similar risks to other revision total knee arthroplasty procedures; specifically, there is a risk of recurrent arthrofibrosis as well as mechanical complications 1,5 . Important Tips: Acronyms and Abbreviations: TKA = total knee arthroplasty AP = anteroposterior CT = computed tomography MRI = magnetic resonance imaging RHK = rotating hinge knee NSAIDs = nonsteroidal anti-inflammatory drugs
- 1 October 2021
- Published by Wolters Kluwer Health in JBJS Essential Surgical Techniques
- Vol. 11 (4)
Rotating Hinge Revision Total Knee Arthroplasty for Severe Arthrofibrosis
Background: Stiffness following total knee arthroplasty is a challenging complication for both the patient and surgeon, with an incidence that ranges from 1% to 13% 1 . There are several correctable mechanical causes for stiffness including malposition, malalignment, overstuffing, aseptic loosening, patella baja, and heterotopic ossification 2 . Idiopathic stiffness is often termed arthrofibrosis and is more difficult to treat 1 . Once patients have exhausted nonoperative options, including physical therapy and manipulation under anesthesia, revision surgery may be considered. Rotating hinge revision total knee arthroplasty has been shown to be an effective surgical treatment for severe arthrofibrosis. Description: First, remove all soft-tissue and osseous sources of stiffness and adequately expose the knee, then remove all previous components. Create a stable and balanced extension gap, and, conversely, a relatively loose flexion gap, which allows for a substantial increase in range of motion. Then, in order to prevent instability in flexion, a rotating hinge prosthesis is utilized, which allows for appropriate kinematic motion despite gap imbalance. Additional steps to regain flexion include medial and lateral distal femoral partial condylectomies, as well as patellar component revision. Alternatives: The first line of treatment for stiffness following total knee arthroplasty is nonoperative and is mainly focused on physical therapy 3 . Manipulation under anesthesia can also be performed within the first 12 weeks postoperatively 3 . Surgical treatments can include arthroscopic debridement as well as open debridement with possible polyethylene liner exchange. If there is a mechanical cause for stiffness, then this should also be addressed surgically. For cases of arthrofibrosis without a clear mechanical etiology or for cases in which the above treatment has failed, complete revision of the femoral and tibial components should be considered 3 . An alternative option to the technique proposed here is to utilize a varus-valgus constrained implant. Rationale: Revision with a hinged implant allows for a more aggressive approach to regaining motion, as compared with all other surgical alternatives. By revising all components, the surgeon is able to remove all sources of stiffness and reconstruct the knee until as much range of motion as possible is achieved. Unfortunately, even with balanced extension and flexion gaps, refractory stiffness is common. A solution for this residual stiffness is to unbalance the gaps and create a loose flexion gap. By doing so, the surgeon is advised to switch to a hinged implant to create a kinematically balanced knee. Any other revision implant, such as a varus-valgus constrained implant, would risk flexion instability. Expected Outcomes: Several studies have examined the use of revision total knee arthroplasty with a hinged implant for arthrofibrosis and have showed substantial improvements in knee range of motion. Bingham et al. showed that the rotating hinge group had a 20° improvement in range of motion (p = 0.048) 1 . Hermans et al. found a 35.8° flexion gain in the hinge group compared with a 14.2° flexion gain in the varus-valgus constrained group (p = 0.0002) 4 . van Rensch et al. found a median gain of 45° of range of motion 5 . Patients should be aware that this procedure involving the use of a hinged implant has similar risks to other revision total knee arthroplasty procedures; specifically, there is a risk of recurrent arthrofibrosis as well as mechanical complications 1,5 . Important Tips: Acronyms and Abbreviations: TKA = total knee arthroplasty AP = anteroposterior CT = computed tomography MRI = magnetic resonance imaging RHK = rotating hinge knee NSAIDs = nonsteroidal anti-inflammatory drugs
- 1 July 2021
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 11 (3)
Adaptive Immune Response Associated with a Zirconium-Containing, Cemented, Total Knee Arthroplasty
Case: A 69-year-old woman underwent revision total knee arthroplasty for patellar component aseptic loosening. The periprosthetic tissue demonstrated histologic features of an adaptive immune response (aseptic lymphocyte-dominant vasculitis-associated lesion [ALVAL]). No particles of corrosion debris were identified. The inflammation seemed to be associated with zirconium oxide (ZrO2) particles added as a bone cement radio-opacifier. Conclusion: The factors responsible for the adaptive immune response cannot be determined with certainty; however, this is the first reported case of ALVAL associated with ZrO2-containing bone cement. Previous reports describing ALVAL around failed total knee prostheses have not included observations about the type of contrast material added to cement.
- 1 July 2021
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 11 (3)
Adaptive Immune Response Associated with a Zirconium-Containing, Cemented, Total Knee Arthroplasty
Case: A 69-year-old woman underwent revision total knee arthroplasty for patellar component aseptic loosening. The periprosthetic tissue demonstrated histologic features of an adaptive immune response (aseptic lymphocyte-dominant vasculitis-associated lesion [ALVAL]). No particles of corrosion debris were identified. The inflammation seemed to be associated with zirconium oxide (ZrO2) particles added as a bone cement radio-opacifier. Conclusion: The factors responsible for the adaptive immune response cannot be determined with certainty; however, this is the first reported case of ALVAL associated with ZrO2-containing bone cement. Previous reports describing ALVAL around failed total knee prostheses have not included observations about the type of contrast material added to cement.
- Open Access
- 1 July 2021
- Published by Wolters Kluwer Health in JAAOS: Global Research and Reviews
- Vol. 5 (7)
Relatively Low Rate of Heterotopic Ossification Following Primary Total Knee Arthroplasty: A Systematic Review and Meta-analysis
Background: Heterotopic ossification (HO) is abnormal growth of ectopic bone and negatively affects the outcomes after total knee arthroplasty (TKA). This systematic review and meta-analysis were performed to characterize the prevalence and severity of HO after primary TKA. Methods: A systematic review of the literature was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Patient demographics, publication year, and HO prevalence after a primary TKA were recorded. A meta-analysis was performed to determine the overall prevalence of HO formation, and a subanalysis compared the studies published in different timeframes to determine whether a temporal effect exists for HO prevalence. Results: Two thousand nine hundred eighty-eight patients underwent primary TKA across the included studies. Fourteen percent of patients (9% to 20%; I2: 93.68%) developed HO postoperatively during a mean follow-up of 40.1 months (11 to 108 months). HO rates seemed to decrease in studies published in more recent years, with a pooled HO prevalence of 5% (0% to 13%; I2: 92.26%) among studies published in the past 15 years compared with 18% (12% to 25%; I2: 92.49%) among studies published before then. Conclusion: Although studies reported a relatively low overall rate of HO after a primary TKA, the absence of a single, standardized classification system precludes the comparisons of HO severity between studies. Overall, HO prevalence seems to have decreased over time, likely reflecting the changes in perioperative medication protocols.
- 1 July 2021
- Published by Wolters Kluwer Health in JAAOS: Global Research and Reviews
- Vol. 5 (7)
Open AccessRelatively Low Rate of Heterotopic Ossification Following Primary Total Knee Arthroplasty: A Systematic Review and Meta-analysis
Background: Heterotopic ossification (HO) is abnormal growth of ectopic bone and negatively affects the outcomes after total knee arthroplasty (TKA). This systematic review and meta-analysis were performed to characterize the prevalence and severity of HO after primary TKA. Methods: A systematic review of the literature was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Patient demographics, publication year, and HO prevalence after a primary TKA were recorded. A meta-analysis was performed to determine the overall prevalence of HO formation, and a subanalysis compared the studies published in different timeframes to determine whether a temporal effect exists for HO prevalence. Results: Two thousand nine hundred eighty-eight patients underwent primary TKA across the included studies. Fourteen percent of patients (9% to 20%; I2: 93.68%) developed HO postoperatively during a mean follow-up of 40.1 months (11 to 108 months). HO rates seemed to decrease in studies published in more recent years, with a pooled HO prevalence of 5% (0% to 13%; I2: 92.26%) among studies published in the past 15 years compared with 18% (12% to 25%; I2: 92.49%) among studies published before then. Conclusion: Although studies reported a relatively low overall rate of HO after a primary TKA, the absence of a single, standardized classification system precludes the comparisons of HO severity between studies. Overall, HO prevalence seems to have decreased over time, likely reflecting the changes in perioperative medication protocols.
- 1 September 2014
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 33 (9) , 1647-1652
Does the Ulnar Nerve Enlarge After Surgical Transposition?
The purpose of this study was to test the hypothesis that symptomatic transposed ulnar nerves have a larger average cross-sectional area (CSA) than symptomatic in situ ulnar nerves. We conducted a retrospective review of the charts and sonograms of 68 patients who had failed ulnar nerve transposition compared to 48 patients with cubital tunnel syndrome who had not undergone surgical management. In addition, postoperative sonograms were compared with preoperative studies when available. Failure was defined as persistence or recurrence of symptoms of ulnar neuropathy postoperatively. The cross-sectional area of the nerve, subjective echogenicity, and residual sites of compression were recorded. Groups were subsequently compared by t tests. The failed ulnar nerve transposition group showed a mean cross-sectional area ± SD of 17.26 ± 9.93 mm(2), whereas the control group showed a mean cross-sectional area of 13.45 ± 7.33 mm(2). This difference was statistically significant (P= .018). Nontransposed nerves were more likely to have identifiable sites of compression (P< .05). There was a trend toward postoperative enlargement in the 6 patients with available preoperative imaging (P = .17). No difference in subjective echogenicity was found in this analysis. Patients with failed ulnar nerve transposition show a significantly enlarged cross-sectional area when compared to symptomatic nerves in situ. Although a specific etiology for this difference cannot be determined, the data suggest that the reference ranges for the cross-sectional area of the ulnar nerve may need to be revised for those who have undergone surgery.
- 1 September 2014
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 33 (9) , 1647-1652
Does the Ulnar Nerve Enlarge After Surgical Transposition?
The purpose of this study was to test the hypothesis that symptomatic transposed ulnar nerves have a larger average cross-sectional area (CSA) than symptomatic in situ ulnar nerves. We conducted a retrospective review of the charts and sonograms of 68 patients who had failed ulnar nerve transposition compared to 48 patients with cubital tunnel syndrome who had not undergone surgical management. In addition, postoperative sonograms were compared with preoperative studies when available. Failure was defined as persistence or recurrence of symptoms of ulnar neuropathy postoperatively. The cross-sectional area of the nerve, subjective echogenicity, and residual sites of compression were recorded. Groups were subsequently compared by t tests. The failed ulnar nerve transposition group showed a mean cross-sectional area ± SD of 17.26 ± 9.93 mm(2), whereas the control group showed a mean cross-sectional area of 13.45 ± 7.33 mm(2). This difference was statistically significant (P= .018). Nontransposed nerves were more likely to have identifiable sites of compression (P< .05). There was a trend toward postoperative enlargement in the 6 patients with available preoperative imaging (P = .17). No difference in subjective echogenicity was found in this analysis. Patients with failed ulnar nerve transposition show a significantly enlarged cross-sectional area when compared to symptomatic nerves in situ. Although a specific etiology for this difference cannot be determined, the data suggest that the reference ranges for the cross-sectional area of the ulnar nerve may need to be revised for those who have undergone surgery.