Latest Publications

  • Application of a Partial Discharge Diagnosis Method Based on the Novel Multispectral Array Sensor and GMM in Different Insulating Gases

    by Yiming Zang, Yong Qian, Xiaoli Zhou, Antian Xu, Gehao Sheng, Xiuchen Jiang

    Optical detection of partial discharge (PD) is an important means to diagnosis the insulation status of equipment. However, the current optical detection is either unable to perform simultaneous detection of multispectral features or it can only be applied under laboratory conditions. Moreover, the PD of different gases will correspond to different multispectral characteristic distributions, but the current research is only aimed at the study of SF 6 . Therefore, this article proposes a gas-insulated equipment PD detection method based on the multispectral array sensor and Gaussian mixture model (GMM) clustering algorithm in C 4 F 7 N/CO 2 gas mixture and SF 6 . This method adopts the silicon photomultiplier (SiPM) array and multispectral grid to realize the collection of PD optical signals of different wavelength bands, which has a high degree of integration and can be applied in actual equipment. Then through the GMM model, cluster analysis of different multispectral features can effectively diagnose different types of PD defects. In the experiment, four kinds of PD defects under the conditions of five various ratios C 4 F 7 N/CO 2 gas mixture and pure SF 6 gas are used for test. The similarities and differences of the PD multispectral characteristics in phase distribution, energy distribution, and radar chart distribution are studied, which compares the PD multispectral characteristics in C 4 F 7 N/CO 2 gas mixture and SF 6 . According to the experiment result, the diagnosis accuracy in different gases is generally higher than 84%, and the highest can reach 95% in SF 6 . This result shows that the method can well diagnose the PD in both SF 6 and C 4 F 7 N/CO 2 power equipment, which has a wide range of application prospects.


  • A Novel Optical Localization Method for Partial Discharge Source Using ANFIS Virtual Sensors and Simulation Fingerprint in GIL

    by Yiming Zang, Yong Qian, Hui Wang, Antian Xu, Xiaoli Zhou, Gehao Sheng, Xiuchen Jiang

    Partial discharge (PD) detection and localization is one of the most effective methods in gas-insulated transmission lines (GIL) insulation fault diagnosis, which is important to the early troubleshooting and safe operation. Compared with the widely used ultrahigh frequency (UHF) and acoustic PD localization methods, the PD localization method based on optical signals has good resistance to electromagnetic and acoustic interference. However, the current optical localization method comes with several shortcomings: narrow detection range, requiring field experiments to accumulate data, and installing a large number of sensors, which renders low feasibility. Therefore, this article proposes a PD localization method utilizing virtual sensors (VSs) and optical simulation fingerprint. Based on the idea of the digital twin, this method constructs a fingerprint database through optical PD simulation in an equal-sized GIL simulation model, which solves the difficulty of fingerprint collection in actual equipment. Meanwhile, this article predicts the detection value of the VS through the adaptive neuro-fuzzy inference system (ANFIS) to greatly reduce the installation of the actual sensor (AS). Finally, through the support vector machines (SVMs) algorithm, the detection fingerprint that includes the virtual and actual detection values matches with the fingerprint database. The location corresponding to the optimal matching result is recorded as the localization result. As experiments have shown, the average localization error of the proposed method is 19.69 mm, which is 54.8% lower than the one without VSs under the same conditions. The results reveal that this method compensates for the loss of localization accuracy caused by the reduction of ASs, which embodies value in practice.


  • An Optical Partial Discharge Localization Method Based on Simulation and Machine learning in GIL

    by Yiming Zang, Yong Qian, Hui Wang, Antian Xu, Gehao Sheng, Xiuchen Jiang

    As gas-insulated transmission line (GIL) is widely used, the partial discharge (PD) phenomenon that occurs during their operation is one of the main reasons for the deterioration of their insulation status. Therefore, the detection and localization of PD in the GIL plays an important role in ensuring the safe and stable operation of the equipment. At present, the PD localization methods for GIL are mainly ultrahigh frequency (UHF) method and ultrasonic method, while these methods are susceptible to mechanical vibration and electromagnetic interference. Optical detection, as a sensitive and effective PD detection method, is rarely used in the field of GIL PD localization. Accordingly, this paper proposes a GIL PD localization method based on optical PD simulation and machine learning. This method establishes a simulation model that is exactly the same as the actual GIL in terms of structure, size and sensor arrangement, where the PD optical simulation experiment is performed to build a PD simulation fingerprint database. Each fingerprint in the fingerprint database corresponds to a PD source location information. Based on this, the PSO-SVM machine learning algorithm is used to match the actual PD fingerprints with the fingerprints in the simulation fingerprint database to obtain the localization results. This method overcomes the difficulty of collecting a large amount of field data to build a fingerprint database in the existing optical fingerprint localization method through simulation. And the structure of GIL in the simulation can be customized according to the actual equipment, while the workload of obtaining the fingerprint database through actual experiments is very heavy for different types of equipment. Through experimental verification, this paper selects 12 typical locations of PD sources in the GIL experimental tank for testing. The average localization error is 10.58mm.