Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Fahd Hariri has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    AMI-Informed Hierarchical Deep Reinforcement Learning–Model Predictive Control for Coordinated EV, PV, and Battery Energy Management in Campus Microgrids

    by Mousa A. Aljabri, Mohammed O. Bahabri, Nasser A. Alakhrash, Fahd A. Hariri, Mohammad N. Ajour

    This paper proposes an advanced metering infrastructure (AMI)-informed hierarchical energy management framework for coordinated operation of electric vehicles (EVs), photovoltaic (PV) systems, and battery energy storage systems (BESS) in campus microgrids. The proposed two-layer architecture integrates a soft actor–critic (SAC) deep reinforcement learning (DRL) agent in the upper layer with a receding horizon model predictive control (MPC) optimizer in the lower layer. The key novelty is an AMI-to-control pipeline that transforms historical 15 min smart-meter measurements into operational flexibility features and embeds them into a hierarchical SAC–MPC architecture, where the DRL layer provides adaptive coordination and the MPC layer enforces grid, storage, and EV-service constraints. The proposed framework using the real-world Pecan Street data (15 min resolution) of 73 homes across Austin, Texas and California (2014–2019) achieves a 53.1% cost reduction and a 25.7% peak demand reduction when compared with uncontrolled charging, and the proposed framework outperforms MPC-only (50.9%), DRL-only (−5.2%), and rule-based (5.1%) baselines. The statistically significant contributions of network-aware constraints, demand-response activation, and predictive look-ahead horizon are statistically significant (n = 10 independent runs) contributions (p = 0.001). The state representation informed by AMI offers directional cost improvement (+8.4%, p = 0.055) with 11% faster convergence of training. The zero network constraint violation is observed in all evaluation scenarios and the average MPC solve time is around 150 ms, which is much less than the 15 min sampling period. Sensitivity analyses show that the hierarchical DRL–MPC architecture remains computationally feasible across EV penetration, seasonal, and forecast-uncertainty scenarios. However, BESS provided no net economic benefit under the evaluated energy-only TOU tariff, increasing weekly cost by $15.25 and peak grid demand by 14.2 kW. Break-even analysis indicates that demand charges of approximately $9.9/kW per month are required for BESS to become cost-effective in the proxy system, highlighting that storage value depends strongly on tariff design and peak-demand objective formulation.


  • Open Access

    Assessment of Various Three-Phase PLLs Based on SOGI-QSG for Grid Synchronization Under Unbalanced Grid Conditions

    by Atif Ali Alqarni, Abdullah Ali Alhussainy, Fahd Hariri, Sultan Alghamdi, Yusuf A. Alturki

    In grid-connected inverter systems, the Phase-Locked Loop (PLL) is fundamental for achieving and maintaining precise synchronization between the inverter and the electrical grid. Developing an efficient and robust PLL is essential to ensure reliable operation, particularly in the presence of abnormal grid conditions. Among the existing synchronization methods, the Synchronous Reference Frame-based PLL (SRF-PLL) is widely adopted due to its robust performance; however, it suffers from degraded accuracy under unbalanced voltage conditions. To address this limitation, the Second-Order Generalized Integrator-Quadrature Signal Generator (SOGI-QSG) was proposed in previous studies as an alternative approach. Despite its advantages, the SOGI-PLL exhibits weak filtering capability for lower-order harmonics and remains sensitive to DC offset, both of which can affect synchronization quality. As a result, numerous advanced PLLs based on SOGI-QSG have been proposed in the literature to address SOGI-QSG limitations by enhancing DC offset rejection, filtering capability, and dynamic response. This article provides a comprehensive assessment of various three-phase PLLs based on SOGI-QSG under unbalanced grid conditions, focusing on peak-to-peak frequency error, filtering performance, and DC offset rejection. The operational principles and mathematical models of each technique are discussed, and their performances are validated using MATLAB/Simulink (R2025b). The results show that the SRF-PLL exhibits oscillatory behavior under unbalanced conditions, whereas the PLLs based on SOGI-QSG demonstrate stable synchronization with different trade-offs between filtering strength and dynamic response. Therefore, the selection of the appropriate PLLs based on SOGI-QSG depends on the priorities of the specific application.


  • Open Access

    Hybrid Wind–Solar–Fuel Cell–Battery Power System with PI Control for Low-Emission Marine Vessels in Saudi Arabia

    by Hussam A. Banawi, Mohammed O. Bahabri, Fahd A. Hariri, Mohammed N. Ajour

    The maritime industry is under increasing pressure to reduce greenhouse gas emissions, especially in countries such as Saudi Arabia that are actively working to transition to cleaner energy. In this paper, a new hybrid shipboard power system, which incorporates wind turbines, solar photovoltaic (PV) panels, proton-exchange membrane fuel cells (PEMFCs), and a battery energy storage system (BESS) together for propulsion and hotel load services, is proposed. A multi-loop Energy Management System (EMS) based on proportional–integral control (PI) is developed to coordinate the interconnections of the power sources in real time. In contrast to the widely reported model predictive or artificial intelligence optimization schemes, the PI-derived EMS achieves similar power stability and hydrogen utilization efficiency with significantly reduced computational overhead and full marine suitability. By taking advantage of the high solar irradiance and coastal wind resources in Saudi Arabia, the proposed configuration provides continuous near-zero-emission operation. Simulation results show that the PEMFC accounts for about 90% of the total energy demand, the BESS (±0.4 MW, 2 MWh) accounts for about 3%, and the stationary renewables account for about 7%, which reduces the demand for hydro-gas to about 160 kg. The DC-bus voltage is kept within ±5% of its nominal value of 750 V, and the battery state of charge (SOC) is kept within 20% to 80%. Sensitivity analyses show that by varying renewable input by ±20%, diesel consumption is ±5%. These results demonstrate the system’s ability to meet International Maritime Organization (IMO) emission targets by delivering stable near-zero-emission operation, while achieving high hydrogen efficiency and grid stability with minimal computational cost. Consequently, the proposed system presents a realistic, certifiable, and regionally optimized roadmap for next-generation hybrid PEMFC–battery–renewable marine power systems in Saudi Arabian coastal operations.


  • Open Access

    Performance Assessment of Current Feedback-Based Active Damping Techniques for Three-Phase Grid-Connected VSCs with LCL Filters

    by Mustafa Ali, Abdullah Ali Alhussainy, Fahd Hariri, Sultan Alghamdi, Yusuf A. Alturki

    The voltage source converters convert the DC to AC in order to interface distributed generation units with the utility grid, typically using an LCL filter to smooth the modulated wave. However, the LCL filter can introduce resonance, potentially cause instability, and necessitate the use of damping techniques, such as active damping, which utilizes feedback from the current control loop to suppress resonance. This paper presents a comprehensive performance assessment of four current-feedback-based active damping (AD) techniques—converter current feedback (CCF), CCF with capacitor current feedback (CCFAD), grid current feedback (GCF), and GCF with capacitor current feedback (GCFAD)—under a broad range of realistic grid disturbances and low switching frequency conditions. Unlike prior works that often analyze individual feedback strategies in isolation, this study highlights and compares their dynamic behavior, robustness, and total harmonic distortion (THD) in eight operational scenarios. The results reveal the severe instability of GCF in the absence of damping and the superior inherent damping property of CCF while demonstrating the comparable effectiveness of GCFAD. Moreover, a simplified yet robust design methodology for the LCL filter is proposed, enabling the filter to maintain stability and performance even under significant variations in grid impedance. Additionally, a sensitivity analysis of switching frequency variation is included. The findings offer valuable insights into selecting and implementing robust active damping methods for grid-connected converters operating at constrained switching frequencies. The effectiveness of the proposed methods has been validated through both MATLAB/Simulink simulations and hardware-in-the-loop (HIL) testing.


  • Open Access

    Optimization and Sensitivity Analysis of Using Renewable Energy Resources for Yanbu City

    by Salman M. Yanbuawi, Amir A. Imam, Abdullah Ali Alhussainy, Sultan Alghamdi, Fahd Hariri, Muhyaddin Rawa

    This study presents a techno-economic and environmental analysis of hybrid renewable energy systems to identify the optimal configuration for supplying the planned 850 MW renewable energy plant in Yanbu city, Saudi Arabia. Ten grid-connected system designs combining photovoltaic (PV), wind turbine (WT), and battery storage were simulated and optimized using the HOMER Grid software (1.10.2 pro edition). A site suitability analysis was conducted to evaluate potential locations based on climatic, topographic, and infrastructure-related factors. A sensitivity analysis considered variations in solar irradiation, wind speed, temperature, load demand, and economic parameters. The results showed that the PV-only system with an 850 MW capacity achieved the lowest net present cost (NPC) of USD 201 million and levelized cost of energy (LCOE) of 0.0344 USD/kWh, making it the most economically feasible option. However, a hybrid WT–PV configuration of 212.5 MW WT and 637.5 MW PV was also proposed to support local manufacturing. All proposed systems provided over a 91% renewable energy contribution while reducing CO2 emissions by 53% compared to grid supply only. Up to 1152 jobs are estimated to be created through renewable energy deployment in Yanbu city.


  • Thermal model of supercapacitors operating in constant power applications: New mathematical expressions for precise calculation of temperature change

    by Muhyaddin Rawa, Sultan Alghamdi, Ahmad H. Milyani, Fahd Hariri, Baheej Alghamdi, Mohammed Ajour, Martin Ćalasan, Ziad M. Ali, Hany M. Hasanien, Bozidar Popovic, et al.


  • Modeling and Simulation of Resistive Superconducting Fault Current Limiter in PSCAD/EMTDC™

    by Fahd Hariri, Mariesa Crow

    Energy networks are facing significant challenges as the result of increasing electrical loads. To meet this rapid increase in demand for electricity, new generating units are being added to support the stability and reliability of the network. This change in network structure requires a comprehensive analysis of the effect of that increase on the protection system. Limiting the fault current to safe levels prevents replacing the high-cost network components that may be subjected to damage due to exceeding the rated short-circuit current values for which they were designed. A fault analysis often requires extensive modeling and simulation of the system, which requires accurate models of the protection system. This paper proposes a model for the resistive superconducting fault current limiter (SFCL) in PSCAD®/EMTDC™. The performance of the model is validated using a small test system.


  • Open Access

    New Infeed Correction Methods for Distance Protection in Distribution Systems

    by Fahd Hariri, Mariesa Crow

    The reliability and security of power systems may be jeopardized by the increase in the amounts of renewable generation and the uncertainties produced by these devices. In particular, the protection schemes of traditional power systems have been challenged by the integration of distributed generation (DG) resources. Distance relays (DRs), which have been mainly employed to protect transmission systems, are increasingly proposed as one of the solutions to protect distribution systems with a heavy penetration of DGs. However, conventional distance protection faces several drawbacks that might lead to maloperation. One of those challenges is the “infeed effect”, which causes the impedance seen by the distance relay to be larger than the actual positive-sequence line impedance between the fault and relay location. This paper proposes three new methods to estimate the distance to the fault in the presence of infeeds, whether in a radial distribution feeder or the transmission line. Unlike other solution methodologies in the literature that require communication links to estimate the distance to the fault, the proposed methods only need the local measurement (i.e., the voltage and current measurements at the location of the distance relay) to do the same. The performance of the method is demonstrated with a radial distribution system model in PSCAD™/EMTDC™.