Ryosuke Kasai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ryosuke Kasai has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Tetsuya Yoshinaga
Institute of Biomedical Sciences, Tokushima University, 3-18-15 Kuramoto, Tokushima 770-8509, Japan
7 shared publications - Omar M. Abou Al-Ola
Faculty of Science, Tanta University, El-Giesh St., Tanta 31527, Egypt
6 shared publications - Hideki Otsuka
Department of Medical Imaging/Nuclear Medicine, Tokushima University Graduate School of Biomedical Sciences, Tokushima, Japan
5 shared publications - Takeshi Kojima
Institute of Biomedical Sciences, Tokushima University, 3-18-15 Kuramoto, Tokushima 770-8509, Japan
4 shared publications - Yusaku Yamaguchi
Shikoku Medical Center for Children and Adults, National Hospital Organization, 2-1-1 Senyu, Zentsuji 765-8507, Japan
3 shared publications Hideki Otsuka
2 shared publications
Latest Publications
- Open Access
- 13 October 2026
- Published by MDPI AG in Mathematics
- Vol. 14 (20) , 3713
Doubly Inertial Coupled Dynamical System for Linear Inverse Problems
We propose a doubly inertial coupled dynamical system (DICDS) for linear inverse problems, extending an existing first-order coupled dynamical system by introducing second-order dynamics for both the unknown variable x and an auxiliary variable y representing the measurement process. Rather than designing an iterative algorithm directly, we formulate the problem as a continuous-time dynamical system whose equilibrium coincides with the solution set of the underlying model, and establish its asymptotic stability via a spectral analysis yielding a necessary and sufficient condition and a Lyapunov-function argument yielding a sufficient condition that clarifies the dissipative structure of the dynamics. This stability theory covers both underdetermined systems, where the equilibrium forms a manifold, and the complementary case with at least as many measurements as unknowns, where it reduces to a unique point whose x-component is the least-squares solution. A direct Euler discretization of the DICDS is numerically unstable; instead, we formulate a separate quasi-inertial continuous-time system that shares the same equilibrium structure and whose Euler discretization yields a two-variable iterative algorithm with momentum-type updates. Numerical experiments on tomographic reconstruction show that the proposed algorithm achieves more effective noise suppression and structural preservation than the corresponding non-inertial coupled method, with the coupling and inertial mechanisms playing distinct roles depending on the measurement-noise level.
- 13 October 2026
- Published by MDPI AG in Mathematics
- Vol. 14 (20) , 3713
Open AccessDoubly Inertial Coupled Dynamical System for Linear Inverse Problems
We propose a doubly inertial coupled dynamical system (DICDS) for linear inverse problems, extending an existing first-order coupled dynamical system by introducing second-order dynamics for both the unknown variable x and an auxiliary variable y representing the measurement process. Rather than designing an iterative algorithm directly, we formulate the problem as a continuous-time dynamical system whose equilibrium coincides with the solution set of the underlying model, and establish its asymptotic stability via a spectral analysis yielding a necessary and sufficient condition and a Lyapunov-function argument yielding a sufficient condition that clarifies the dissipative structure of the dynamics. This stability theory covers both underdetermined systems, where the equilibrium forms a manifold, and the complementary case with at least as many measurements as unknowns, where it reduces to a unique point whose x-component is the least-squares solution. A direct Euler discretization of the DICDS is numerically unstable; instead, we formulate a separate quasi-inertial continuous-time system that shares the same equilibrium structure and whose Euler discretization yields a two-variable iterative algorithm with momentum-type updates. Numerical experiments on tomographic reconstruction show that the proposed algorithm achieves more effective noise suppression and structural preservation than the corresponding non-inertial coupled method, with the coupling and inertial mechanisms playing distinct roles depending on the measurement-noise level.
- 15 June 2026
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 51 (10) , e934-e936
Pancreatic Uptake on 99mTc-MIBI and 99mTc-Tetrofosmin Myocardial Perfusion SPECT/CT
Pancreatic uptake can be observed on routine 99m Tc-MIBI and 99m Tc-tetrofosmin myocardial perfusion SPECT/CT. We present representative cases demonstrating visually prominent pancreatic activity relative to hepatic and splenic uptake. Hybrid SPECT/CT enabled confident anatomic localization of pancreatic activity and differentiation from adjacent hepatobiliary and intestinal activity. Recognition of this finding may facilitate interpretation of extracardiac tracer activity during routine myocardial perfusion imaging and reduce uncertainty related to subdiaphragmatic tracer distribution.
- 15 June 2026
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 51 (10) , e934-e936
Pancreatic Uptake on 99mTc-MIBI and 99mTc-Tetrofosmin Myocardial Perfusion SPECT/CT
Pancreatic uptake can be observed on routine 99m Tc-MIBI and 99m Tc-tetrofosmin myocardial perfusion SPECT/CT. We present representative cases demonstrating visually prominent pancreatic activity relative to hepatic and splenic uptake. Hybrid SPECT/CT enabled confident anatomic localization of pancreatic activity and differentiation from adjacent hepatobiliary and intestinal activity. Recognition of this finding may facilitate interpretation of extracardiac tracer activity during routine myocardial perfusion imaging and reduce uncertainty related to subdiaphragmatic tracer distribution.
- Open Access
- 1 June 2026
- Published by MDPI AG in Mathematics
- Vol. 14 (11) , 1912
Dynamical System Approach to Linear Inverse Problems Using Mutual Power Divergence
We present a dynamical-system approach to linear inverse problems based on a newly introduced discrepancy measure called the mutual power divergence (MPD). The MPD evaluates the mutual consistency between the measurement and the prediction and serves as a Lyapunov function for constructing a continuous-time dynamical system associated with the inverse problem. The equilibrium points of the system coincide with solutions of the linear model, and their stability is established using Lyapunov theory and LaSalle’s invariance principle. By discretizing the continuous-time dynamics with a multiplicative Euler scheme, we obtain an iterative reconstruction algorithm with multiplicative updates. The resulting iteration constitutes a two-parameter extension of the simultaneous multiplicative algebraic reconstruction technique. Numerical experiments on tomographic reconstruction problems demonstrate that the proposed algorithm achieves improved reconstruction accuracy over existing multiplicative methods.
- 1 June 2026
- Published by MDPI AG in Mathematics
- Vol. 14 (11) , 1912
Open AccessDynamical System Approach to Linear Inverse Problems Using Mutual Power Divergence
We present a dynamical-system approach to linear inverse problems based on a newly introduced discrepancy measure called the mutual power divergence (MPD). The MPD evaluates the mutual consistency between the measurement and the prediction and serves as a Lyapunov function for constructing a continuous-time dynamical system associated with the inverse problem. The equilibrium points of the system coincide with solutions of the linear model, and their stability is established using Lyapunov theory and LaSalle’s invariance principle. By discretizing the continuous-time dynamics with a multiplicative Euler scheme, we obtain an iterative reconstruction algorithm with multiplicative updates. The resulting iteration constitutes a two-parameter extension of the simultaneous multiplicative algebraic reconstruction technique. Numerical experiments on tomographic reconstruction problems demonstrate that the proposed algorithm achieves improved reconstruction accuracy over existing multiplicative methods.
- Open Access
- 12 March 2026
- Published by MDPI AG in Journal of Imaging
- Vol. 12 (3) , 126
Parameter Selection in Coupled Dynamical Systems for Tomographic Image Reconstruction
This study investigates the performance of image-reconstruction methods derived from coupled dynamical systems for solving linear inverse problems, focusing on how appropriate parameter selection enhances noise-suppression capability in tomographic image reconstruction. Our previous work has established the stability of linear and nonlinear variants of such systems on the basis of Lyapunov’s theorem. However, the influence of parameter choice on reconstruction quality has not been fully clarified. To address this issue, we introduce a parameter adjustment strategy based on an optimization principle. Two complementary optimization strategies are considered. The first employs ground-truth images to determine optimal parameter values that serve as a numerical benchmark for evaluating reconstruction performance. The second relies solely on measured projection data, enabling practical application without prior knowledge of the true image. Numerical experiments using phantoms with relatively high noise levels demonstrate that appropriate parameter selection markedly improves reconstruction accuracy and robustness. These results clarify how properly tuned reconstruction methods derived from coupled dynamical systems can effectively exploit their inherent dynamics to achieve noise suppression in tomographic inverse problems.
- 12 March 2026
- Published by MDPI AG in Journal of Imaging
- Vol. 12 (3) , 126
Open AccessParameter Selection in Coupled Dynamical Systems for Tomographic Image Reconstruction
This study investigates the performance of image-reconstruction methods derived from coupled dynamical systems for solving linear inverse problems, focusing on how appropriate parameter selection enhances noise-suppression capability in tomographic image reconstruction. Our previous work has established the stability of linear and nonlinear variants of such systems on the basis of Lyapunov’s theorem. However, the influence of parameter choice on reconstruction quality has not been fully clarified. To address this issue, we introduce a parameter adjustment strategy based on an optimization principle. Two complementary optimization strategies are considered. The first employs ground-truth images to determine optimal parameter values that serve as a numerical benchmark for evaluating reconstruction performance. The second relies solely on measured projection data, enabling practical application without prior knowledge of the true image. Numerical experiments using phantoms with relatively high noise levels demonstrate that appropriate parameter selection markedly improves reconstruction accuracy and robustness. These results clarify how properly tuned reconstruction methods derived from coupled dynamical systems can effectively exploit their inherent dynamics to achieve noise suppression in tomographic inverse problems.
- Open Access
- 20 January 2026
- Published by MDPI AG in Journal of Imaging
- Vol. 12 (1) , 48
Graph-Enhanced Expectation Maximization for Emission Tomography
Emission tomography, including single-photon emission computed tomography (SPECT), requires image reconstruction from noisy and incomplete projection data. The maximum-likelihood expectation maximization (MLEM) algorithm is widely used due to its statistical foundation and non-negativity preservation, but it is highly sensitive to noise, particularly in low-count conditions. Although total variation (TV) regularization can reduce noise, it often oversmooths structural details and requires careful parameter tuning. We propose a Graph-Enhanced Expectation Maximization (GREM) algorithm that incorporates graph-based neighborhood information into an MLEM-type multiplicative reconstruction scheme. The method is motivated by a penalized formulation combining a Kullback–Leibler divergence term with a graph Laplacian regularization term, promoting local structural consistency while preserving edges. The resulting update retains the multiplicative structure of MLEM and preserves the non-negativity of the image estimates. Numerical experiments using synthetic phantoms under multiple noise levels, as well as clinical 99mTc-GSA liver SPECT data, demonstrate that GREM consistently outperforms conventional MLEM and TV-regularized MLEM in terms of PSNR and MS-SSIM. These results indicate that GREM provides an effective and practical approach for edge-preserving noise suppression in emission tomography without relying on external training data.
- 20 January 2026
- Published by MDPI AG in Journal of Imaging
- Vol. 12 (1) , 48
Open AccessGraph-Enhanced Expectation Maximization for Emission Tomography
Emission tomography, including single-photon emission computed tomography (SPECT), requires image reconstruction from noisy and incomplete projection data. The maximum-likelihood expectation maximization (MLEM) algorithm is widely used due to its statistical foundation and non-negativity preservation, but it is highly sensitive to noise, particularly in low-count conditions. Although total variation (TV) regularization can reduce noise, it often oversmooths structural details and requires careful parameter tuning. We propose a Graph-Enhanced Expectation Maximization (GREM) algorithm that incorporates graph-based neighborhood information into an MLEM-type multiplicative reconstruction scheme. The method is motivated by a penalized formulation combining a Kullback–Leibler divergence term with a graph Laplacian regularization term, promoting local structural consistency while preserving edges. The resulting update retains the multiplicative structure of MLEM and preserves the non-negativity of the image estimates. Numerical experiments using synthetic phantoms under multiple noise levels, as well as clinical 99mTc-GSA liver SPECT data, demonstrate that GREM consistently outperforms conventional MLEM and TV-regularized MLEM in terms of PSNR and MS-SSIM. These results indicate that GREM provides an effective and practical approach for edge-preserving noise suppression in emission tomography without relying on external training data.
- Open Access
- 31 December 2025
- Published by Springer Nature in EJNMMI Physics
- Vol. 13 (1)
Feasibility study of unsupervised anomaly detection using Wasserstein GAN in SPECT image
In this study, we constructed an anomaly detection system based on the Wasserstein generative model in brain single-photon emission computed tomography (SP
- 31 December 2025
- Published by Springer Nature in EJNMMI Physics
- Vol. 13 (1)
Open AccessFeasibility study of unsupervised anomaly detection using Wasserstein GAN in SPECT image
In this study, we constructed an anomaly detection system based on the Wasserstein generative model in brain single-photon emission computed tomography (SP
- Open Access
- 21 October 2025
- Published by MDPI AG in Mathematics
- Vol. 13 (20) , 3347
Coupled Dynamical Systems for Solving Linear Inverse Problems
We propose a class of coupled dynamical systems for solving linear inverse problems, treating both the unknown variable and an auxiliary variable representing measurement dynamics as state variables. This framework does not rely on probabilistic modeling or explicit regularization; instead, it achieves noise suppression through deterministic interactions between system variables. We analyze the theoretical properties of the systems, including stability, equilibrium behavior, and convergence for the linear system, and equilibrium stability for the two nonlinear variants. The nonlinear extensions incorporate state-dependent mechanisms that preserve equilibrium stability while enhancing convergence and robustness in practice. Numerical experiments illustrate the effectiveness of the proposed approach in estimating the unknown variable and mitigating measurement noise.
- 21 October 2025
- Published by MDPI AG in Mathematics
- Vol. 13 (20) , 3347
Open AccessCoupled Dynamical Systems for Solving Linear Inverse Problems
We propose a class of coupled dynamical systems for solving linear inverse problems, treating both the unknown variable and an auxiliary variable representing measurement dynamics as state variables. This framework does not rely on probabilistic modeling or explicit regularization; instead, it achieves noise suppression through deterministic interactions between system variables. We analyze the theoretical properties of the systems, including stability, equilibrium behavior, and convergence for the linear system, and equilibrium stability for the two nonlinear variants. The nonlinear extensions incorporate state-dependent mechanisms that preserve equilibrium stability while enhancing convergence and robustness in practice. Numerical experiments illustrate the effectiveness of the proposed approach in estimating the unknown variable and mitigating measurement noise.
- Open Access
- 27 June 2025
- Published by MDPI AG in Journal of Imaging
- Vol. 11 (7) , 213
Iterative Reconstruction with Dynamic ElasticNet Regularization for Nuclear Medicine Imaging
This study proposes a novel image reconstruction algorithm for nuclear medicine imaging based on the maximum likelihood expectation maximization (MLEM) framework with dynamic ElasticNet regularization. Whereas conventional the L1 and L2 regularization methods involve trade-offs between noise suppression and structural preservation, ElasticNet combines their strengths. Our method further introduces a dynamic weighting scheme that adaptively adjusts the balance between the L1 and L2 terms over iterations while ensuring nonnegativity when using a sufficiently small regularization parameter. We evaluated the proposed algorithm using numerical phantoms (Shepp–Logan and digitized Hoffman) under various noise conditions. Quantitative results based on the peak signal-to-noise ratio and multi-scale structural similarity index measure demonstrated that the proposed dynamic ElasticNet regularized MLEM consistently outperformed not only standard MLEM and L1/L2 regularized MLEM but also the fixed-weight ElasticNet variant. Clinical single-photon emission computed tomography brain image experiments further confirmed improved noise suppression and clearer depiction of fine structures. These findings suggest that our proposed method offers a robust and accurate solution for tomographic image reconstruction in nuclear medicine imaging.
- 27 June 2025
- Published by MDPI AG in Journal of Imaging
- Vol. 11 (7) , 213
Open AccessIterative Reconstruction with Dynamic ElasticNet Regularization for Nuclear Medicine Imaging
This study proposes a novel image reconstruction algorithm for nuclear medicine imaging based on the maximum likelihood expectation maximization (MLEM) framework with dynamic ElasticNet regularization. Whereas conventional the L1 and L2 regularization methods involve trade-offs between noise suppression and structural preservation, ElasticNet combines their strengths. Our method further introduces a dynamic weighting scheme that adaptively adjusts the balance between the L1 and L2 terms over iterations while ensuring nonnegativity when using a sufficiently small regularization parameter. We evaluated the proposed algorithm using numerical phantoms (Shepp–Logan and digitized Hoffman) under various noise conditions. Quantitative results based on the peak signal-to-noise ratio and multi-scale structural similarity index measure demonstrated that the proposed dynamic ElasticNet regularized MLEM consistently outperformed not only standard MLEM and L1/L2 regularized MLEM but also the fixed-weight ElasticNet variant. Clinical single-photon emission computed tomography brain image experiments further confirmed improved noise suppression and clearer depiction of fine structures. These findings suggest that our proposed method offers a robust and accurate solution for tomographic image reconstruction in nuclear medicine imaging.
- Open Access
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Dynamic ElasticNet Regularization for Enhanced Tomographic Image Reconstruction in Nuclear Medicine
This study proposes a novel maximum likelihood expectation maximization (MLEM) algorithm that incorporates dynamic ElasticNet regularization to enhance the image quality in nuclear medicine tomographic reconstruction. Conventional regularization methods often struggle to balance noise reduction and detail preservation. Our proposed approach leverages the advantages of ElasticNet regularization, which combines L1 and L2 norms while dynamically adjusting their weights during each iteration based on the number of iterations. We conducted numerical experiments using the Shepp-Logan and digitized Hoffman phantoms under varying noise levels. These experiments showcased the superiority of the proposed method over the conventional MLEM, as well as L1 and L2 regularized MLEM, in terms of objective image quality metrics. The proposed algorithm effectively suppressed noise while preserving crucial structural information, even in highnoise conditions. Furthermore, qualitative assessments using clinical SPECT brain imaging data demonstrated promising outcomes in noise reduction and the visualization of fine structures. This study highlights the potential of the proposed dynamic ElasticNet regularized MLEM algorithm as a valuable approach for achieving more accurate and clinically relevant image reconstruction in nuclear medicine imaging.
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessDynamic ElasticNet Regularization for Enhanced Tomographic Image Reconstruction in Nuclear Medicine
This study proposes a novel maximum likelihood expectation maximization (MLEM) algorithm that incorporates dynamic ElasticNet regularization to enhance the image quality in nuclear medicine tomographic reconstruction. Conventional regularization methods often struggle to balance noise reduction and detail preservation. Our proposed approach leverages the advantages of ElasticNet regularization, which combines L1 and L2 norms while dynamically adjusting their weights during each iteration based on the number of iterations. We conducted numerical experiments using the Shepp-Logan and digitized Hoffman phantoms under varying noise levels. These experiments showcased the superiority of the proposed method over the conventional MLEM, as well as L1 and L2 regularized MLEM, in terms of objective image quality metrics. The proposed algorithm effectively suppressed noise while preserving crucial structural information, even in highnoise conditions. Furthermore, qualitative assessments using clinical SPECT brain imaging data demonstrated promising outcomes in noise reduction and the visualization of fine structures. This study highlights the potential of the proposed dynamic ElasticNet regularized MLEM algorithm as a valuable approach for achieving more accurate and clinically relevant image reconstruction in nuclear medicine imaging.
- 4 March 2025
- Published by Springer Nature in Oral Radiology
- Vol. 41 (3) , 421-429
Evaluation of the effect of reducing metal artifacts in multi-detector CT imaging of zirconia and titanium implants
Objectives Zirconia oral implants produce larger artifacts on computed tomography (CT) compared to titanium oral implants. This study aimed to compare the effectiveness of metal artifact reduction (MAR) software and dual-energy (DE) methods, which are used in multi-detector CT (MDCT) to reduce the artifacts produced by titanium and zirconia oral implants. Methods Oral implants were placed in the lower right second premolar and second molar regions of an acrylic mandible model and evaluated using MDCT. For MAR, Single Energy Metal Artifact Reaction (SEMAR) images were obtained, and for DE, images were obtained at 135 keV. The evaluation was based on 21 regions of interest (ROIs) with sides of 2.8 mm, set at 15, 25, and 35 mm from the center (the lower-right first premolar), with 65°, 90°, 115°, and 145° angles set on the buccal and lingual sides. The evaluation was based on an Artifact Index (AI). Results The lingual aspect of the AI tended to be larger compared to the buccal aspect, regardless of the image-processing method. In addition, the SEMAR method tended to have a greater artifact reduction effect than the DE method. The distortion of the mandibular model and occurrence of new artifacts were confirmed using SEMAR. Conclusions SEMAR had higher artifact reduction effects on metal artifacts than the DE method. Although SEMAR and dual-energy methods can effectively reduce metal artifacts, they also cause false images and areas that cannot be observed. Therefore, diagnostic and treatment planning, including imaging, is essential before artifact reduction processing.
- 4 March 2025
- Published by Springer Nature in Oral Radiology
- Vol. 41 (3) , 421-429
Evaluation of the effect of reducing metal artifacts in multi-detector CT imaging of zirconia and titanium implants
Objectives Zirconia oral implants produce larger artifacts on computed tomography (CT) compared to titanium oral implants. This study aimed to compare the effectiveness of metal artifact reduction (MAR) software and dual-energy (DE) methods, which are used in multi-detector CT (MDCT) to reduce the artifacts produced by titanium and zirconia oral implants. Methods Oral implants were placed in the lower right second premolar and second molar regions of an acrylic mandible model and evaluated using MDCT. For MAR, Single Energy Metal Artifact Reaction (SEMAR) images were obtained, and for DE, images were obtained at 135 keV. The evaluation was based on 21 regions of interest (ROIs) with sides of 2.8 mm, set at 15, 25, and 35 mm from the center (the lower-right first premolar), with 65°, 90°, 115°, and 145° angles set on the buccal and lingual sides. The evaluation was based on an Artifact Index (AI). Results The lingual aspect of the AI tended to be larger compared to the buccal aspect, regardless of the image-processing method. In addition, the SEMAR method tended to have a greater artifact reduction effect than the DE method. The distortion of the mandibular model and occurrence of new artifacts were confirmed using SEMAR. Conclusions SEMAR had higher artifact reduction effects on metal artifacts than the DE method. Although SEMAR and dual-energy methods can effectively reduce metal artifacts, they also cause false images and areas that cannot be observed. Therefore, diagnostic and treatment planning, including imaging, is essential before artifact reduction processing.