Andreas Kannenberg
Research Subjects
Andreas Kannenberg has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Susanne Seidinger
Affiliated with Otto Bock HealthCare Products GmbH, Vienna, Austria
3 shared publications - Andreas Hahn
Otto Bock Healthcare Products GmbH, Vienna, Austria
2 shared publications - Bernd Brüggenjürgen
Institute for Health Services Research and Technical Orthopedics, Orthopedic Department - Medical School Hannover (MHH) at DIAKOVERE Annastift Hospital, Hannover, Germany
2 shared publications Christina Stukenborg-Colsman
Foot Department, Orthopedic Department - Medical School Hannover (MHH) at DIAKOVERE Annastift Hospital, Hannover, Germany
2 shared publications- Michael Ernst
Research Biomechanics, Ottobock SE & Co. KGaA, Göttingen, Germany
2 shared publications - Al Dobson
Affiliated with Dobson|DaVanzo & Associates, LLC, Vienna, Virginia
1 shared publication
Latest Publications
- Open Access
- 28 January 2026
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 9 (1)
HEALTH-RELATED QUALITY OF LIFE IN AMPUTEES WITH A MICROPROCESSOR-CONTROLLED PROSTHETIC KNEE MEASURED BY THE EQ-5D-5L
BACKGROUND: Enhancing health-related quality of life (HRQoL) is a fundamental objective of healthcare delivery. Individuals with amputation might encounter physical, psychological, and social challenges in daily life which might be influenced by the type of prosthetic knee provided. OBJECTIVE: To understand the experience-based HRQoL of amputees who were using a microprocessor-controlled prosthetic knee (MPK). METHODOLOGY: Amputees using an MPK for at least 3 months (C-Leg or Genium/Genium X3) participated in an online survey. In 2022 1,868 MPK user were invited to participate in the study via both desktop and mobile platforms of a German manufacturer database. HRQoL was assessed with the EuroQol 5-Dimension 5-Level (EQ-5D-5L) instrument. The data was analyzed descriptively and by measures of central tendency. FINDINGS: 512 participants (19.7% female, mean age 54 years (standard deviation 12.6)) responded and fully completed the EQ-5D-5L. The leading cause of amputation was trauma (56.1%), followed by tumor (15.6%) and peripheral arterial disease (PAD, 11.3%). 18.2% reported being completely problem-free. 2.9% had a hip disarticulation, 68.0% a transfemoral amputation, 26.6% a knee disarticulation and 2.5% a bilateral amputation. The share of “no problems” was 53.3% for mobility, 88.1% for self-care, 61.5% for usual activities, 25.0% for pain or discomfort, and 67.4% for anxiety/depression. The total mean index score based on the German value set was 0.84 (maximum score 1). The total mean visual analogue scale (VAS) score was 77.4 with variations observed for age and health status. CONCLUSION: Amputees with an MPK experienced very few issues in the self-care dimension but faced more challenges in the pain/discomfort and mobility dimensions. Utilities were similar to the general German norm reporting one medical condition. MPKs enable individuals to achieve quality of life outcomes that are comparable to those observed in the general population. Layman's Abstract We wanted to learn how amputees who use a special prosthetic knee controlled by a microprocessor (“MPK”) in their prosthesis feel about their quality of life. In 2022, 1,868 people who use an MPK from a German manufacturer were invited to take part in an online survey. About one in five participants (19.7%) were women. Most respondents had an above-the-knee amputation (68.0%), while about a quarter had a knee disarticulation (26.6%). A small number had a hip disarticulation (2.9%) or amputations on both sides (2.5%). A tool known as the EQ-5D-5L was used to measure their quality of life. Answers were evaluated descriptively and to identify patterns. A total of 512 people with an average age around 54 years responded to the quality-of-life questionnaires. Most of them lost their limbs due to an accident. About 18% of them said they had no problems at all. The most common problems they faced were related to pain, discomfort, and mobility. On average, their quality-of-life score was 0.84 out of a maximum of 1, where 1 means perfect health. This score is similar to what people in Germany with one chronic medical condition typically report. People using an MPK generally have few problems taking care of themselves but struggle more with pain and moving around. Their overall quality of life is similar as that of the general German population. MPKs enable individuals to achieve quality of life outcomes that are comparable to those observed in the general population. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/46403/34874 How To Cite: Brüggenjürgen B, Kannenberg A, Stukenborg-Colsman C, Hahn A. Health-related quality of life in amputees with a microprocessor-controlled prosthetic knee measured by the EQ-5D-5L. Canadian Prosthetics & Orthotics Journal. 2026; Volume 9, Issue 1, No. 4. https://doi.org/10.33137/cpoj.v9i1.46403 Corresponding Author: Prof. Dr. med. Bernd Brüggenjürgen, MPHAffiliation: Institute for Health Services Research and Technical Orthopedics, Orthopedic Department - Medical School Hannover (MHH) at DIAKOVERE Annastift Hospital, Hannover, Germany.E-Mail: brueggenjuergen.bernd@mh-hannover.deORCID ID: https://orcid.org/0000-0002-8866-0809
- 28 January 2026
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 9 (1)
Open AccessHEALTH-RELATED QUALITY OF LIFE IN AMPUTEES WITH A MICROPROCESSOR-CONTROLLED PROSTHETIC KNEE MEASURED BY THE EQ-5D-5L
BACKGROUND: Enhancing health-related quality of life (HRQoL) is a fundamental objective of healthcare delivery. Individuals with amputation might encounter physical, psychological, and social challenges in daily life which might be influenced by the type of prosthetic knee provided. OBJECTIVE: To understand the experience-based HRQoL of amputees who were using a microprocessor-controlled prosthetic knee (MPK). METHODOLOGY: Amputees using an MPK for at least 3 months (C-Leg or Genium/Genium X3) participated in an online survey. In 2022 1,868 MPK user were invited to participate in the study via both desktop and mobile platforms of a German manufacturer database. HRQoL was assessed with the EuroQol 5-Dimension 5-Level (EQ-5D-5L) instrument. The data was analyzed descriptively and by measures of central tendency. FINDINGS: 512 participants (19.7% female, mean age 54 years (standard deviation 12.6)) responded and fully completed the EQ-5D-5L. The leading cause of amputation was trauma (56.1%), followed by tumor (15.6%) and peripheral arterial disease (PAD, 11.3%). 18.2% reported being completely problem-free. 2.9% had a hip disarticulation, 68.0% a transfemoral amputation, 26.6% a knee disarticulation and 2.5% a bilateral amputation. The share of “no problems” was 53.3% for mobility, 88.1% for self-care, 61.5% for usual activities, 25.0% for pain or discomfort, and 67.4% for anxiety/depression. The total mean index score based on the German value set was 0.84 (maximum score 1). The total mean visual analogue scale (VAS) score was 77.4 with variations observed for age and health status. CONCLUSION: Amputees with an MPK experienced very few issues in the self-care dimension but faced more challenges in the pain/discomfort and mobility dimensions. Utilities were similar to the general German norm reporting one medical condition. MPKs enable individuals to achieve quality of life outcomes that are comparable to those observed in the general population. Layman's Abstract We wanted to learn how amputees who use a special prosthetic knee controlled by a microprocessor (“MPK”) in their prosthesis feel about their quality of life. In 2022, 1,868 people who use an MPK from a German manufacturer were invited to take part in an online survey. About one in five participants (19.7%) were women. Most respondents had an above-the-knee amputation (68.0%), while about a quarter had a knee disarticulation (26.6%). A small number had a hip disarticulation (2.9%) or amputations on both sides (2.5%). A tool known as the EQ-5D-5L was used to measure their quality of life. Answers were evaluated descriptively and to identify patterns. A total of 512 people with an average age around 54 years responded to the quality-of-life questionnaires. Most of them lost their limbs due to an accident. About 18% of them said they had no problems at all. The most common problems they faced were related to pain, discomfort, and mobility. On average, their quality-of-life score was 0.84 out of a maximum of 1, where 1 means perfect health. This score is similar to what people in Germany with one chronic medical condition typically report. People using an MPK generally have few problems taking care of themselves but struggle more with pain and moving around. Their overall quality of life is similar as that of the general German population. MPKs enable individuals to achieve quality of life outcomes that are comparable to those observed in the general population. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/46403/34874 How To Cite: Brüggenjürgen B, Kannenberg A, Stukenborg-Colsman C, Hahn A. Health-related quality of life in amputees with a microprocessor-controlled prosthetic knee measured by the EQ-5D-5L. Canadian Prosthetics & Orthotics Journal. 2026; Volume 9, Issue 1, No. 4. https://doi.org/10.33137/cpoj.v9i1.46403 Corresponding Author: Prof. Dr. med. Bernd Brüggenjürgen, MPHAffiliation: Institute for Health Services Research and Technical Orthopedics, Orthopedic Department - Medical School Hannover (MHH) at DIAKOVERE Annastift Hospital, Hannover, Germany.E-Mail: brueggenjuergen.bernd@mh-hannover.deORCID ID: https://orcid.org/0000-0002-8866-0809
- Open Access
- 28 January 2026
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 9 (1)
COST-EFFECTIVENESS OF MICROPROCESSOR-CONTROLLED PROSTHETIC KNEES IN THE DUTCH HEALTHCARE SYSTEM: THE IMPACT OF STUDY DURATION ON OUTCOMES
A previous health-utility analysis of microprocessor-controlled prosthetic knees (MPKs) in the Netherlands used a very short evaluation period of only 6 months resulting in an extremely high incremental cost-utility ratio (ICUR) of €457,063 per quality-adjusted life year (QALY) gained. However, for proper health-economic analyses, an appropriate time horizon, usually the useful life of an intervention, must be chosen to avoid biased results. Therefore, we performed a basic cost-utility analysis (CUA) extrapolating and properly discounting the utility and cost data reported by that article over the useful lifetime of MPKs of 6 years and found an ICUR of €17,945 per QALY. To further refine the CUA, we conducted a modeling study of the ICUR of the MPKs over a timeframe from 6 months to 25 years using existing and published population models for Germany and Sweden. In the modeling study, the ICUR was higher for the Netherlands with €37,567 per QALY than for Germany (€18,276 per QALY) or Sweden (€11,147 per QALY) but below the Dutch threshold for willingness to pay of €50,000 per QALY for people with a lower-limb amputation. Thus, the MPKs were cost-effective for the Dutch healthcare system in all scenarios of the cost-utility analysis. Our analysis showed that time had a much bigger impact on the ICUR than utility with the MPKs becoming cost-effective with the ICUR falling below the €50,000-per-QALY threshold after 4-5 years of use. Thus, a proper time horizon covering the useful lifetime of an intervention is key for health-economic analyses to prevent potentially misleading results and unjustified detrimental decisions for patients. Layman's Abstract A previous analysis of utility and costs of microprocessor-controlled prosthetic knees (MPKs) compared to non-microprocessor controlled prosthetic knees (NMPKs) for users with above-knee amputation in the Netherlands used a very short evaluation period of 6 months only and found extremely high costs of €457,063 per quality-adjusted life year gained by the MPKs. However, proper health-economic analyses require an appropriate time horizon, which is usually the useful lifetime of the medical device studied. Therefore, we performed a basic cost-utility analysis that extrapolated and properly discounted the utility and cost reported in that study over the useful lifetime of MPKs (6 years) and found costs of only €17,945 per quality-adjusted life year gained. To further refine the analysis, we also conducted a modeling study analyzing MPKs use over a timeframe from 6 months to 25 years using established and published population models for countries comparable to the Netherlands, such as Germany and Sweden. In the modeling study, the cost for the MPKs was higher for the Netherlands (€37,567 per quality-adjusted life year gained) than for Germany (€18,276) or Sweden (€11,147) but below the threshold for what the Dutch healthcare system would be willing to pay for people with above-knee amputations of €50,000 per quality-adjusted life year gained. Thus, the MPKs can be considered cost-effective for the Dutch healthcare system, and their cost starts falling below the willingness-to-pay threshold after 4-5 years of use. Our analysis showed that an appropriate time horizon of health-economic analyses must be chosen to avoid potentially misleading results and detrimental decisions for patients based on too-short evaluation periods. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/46669/34863 How To Cite: Kuhlmann A, Kannenberg A. Cost-effectiveness of microprocessor-controlled prosthetic knees in the Dutch healthcare system: The impact of study duration on outcomes. Canadian Prosthetics & Orthotics Journal. 2026; Volume 9, Issue 1, No. 2. https://doi.org/10.33137/cpoj.v9i1.46669 Corresponding Author: Andreas Kannenberg, PhDAffiliation: Clinical Research & Services, Ottobock Healthcare LP, Austin, TX, USA.E-Mail: andreas.kannenberg@ottobock.comORCID ID: https://orcid.org/0000-0001-7983-1744
- 28 January 2026
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 9 (1)
Open AccessCOST-EFFECTIVENESS OF MICROPROCESSOR-CONTROLLED PROSTHETIC KNEES IN THE DUTCH HEALTHCARE SYSTEM: THE IMPACT OF STUDY DURATION ON OUTCOMES
A previous health-utility analysis of microprocessor-controlled prosthetic knees (MPKs) in the Netherlands used a very short evaluation period of only 6 months resulting in an extremely high incremental cost-utility ratio (ICUR) of €457,063 per quality-adjusted life year (QALY) gained. However, for proper health-economic analyses, an appropriate time horizon, usually the useful life of an intervention, must be chosen to avoid biased results. Therefore, we performed a basic cost-utility analysis (CUA) extrapolating and properly discounting the utility and cost data reported by that article over the useful lifetime of MPKs of 6 years and found an ICUR of €17,945 per QALY. To further refine the CUA, we conducted a modeling study of the ICUR of the MPKs over a timeframe from 6 months to 25 years using existing and published population models for Germany and Sweden. In the modeling study, the ICUR was higher for the Netherlands with €37,567 per QALY than for Germany (€18,276 per QALY) or Sweden (€11,147 per QALY) but below the Dutch threshold for willingness to pay of €50,000 per QALY for people with a lower-limb amputation. Thus, the MPKs were cost-effective for the Dutch healthcare system in all scenarios of the cost-utility analysis. Our analysis showed that time had a much bigger impact on the ICUR than utility with the MPKs becoming cost-effective with the ICUR falling below the €50,000-per-QALY threshold after 4-5 years of use. Thus, a proper time horizon covering the useful lifetime of an intervention is key for health-economic analyses to prevent potentially misleading results and unjustified detrimental decisions for patients. Layman's Abstract A previous analysis of utility and costs of microprocessor-controlled prosthetic knees (MPKs) compared to non-microprocessor controlled prosthetic knees (NMPKs) for users with above-knee amputation in the Netherlands used a very short evaluation period of 6 months only and found extremely high costs of €457,063 per quality-adjusted life year gained by the MPKs. However, proper health-economic analyses require an appropriate time horizon, which is usually the useful lifetime of the medical device studied. Therefore, we performed a basic cost-utility analysis that extrapolated and properly discounted the utility and cost reported in that study over the useful lifetime of MPKs (6 years) and found costs of only €17,945 per quality-adjusted life year gained. To further refine the analysis, we also conducted a modeling study analyzing MPKs use over a timeframe from 6 months to 25 years using established and published population models for countries comparable to the Netherlands, such as Germany and Sweden. In the modeling study, the cost for the MPKs was higher for the Netherlands (€37,567 per quality-adjusted life year gained) than for Germany (€18,276) or Sweden (€11,147) but below the threshold for what the Dutch healthcare system would be willing to pay for people with above-knee amputations of €50,000 per quality-adjusted life year gained. Thus, the MPKs can be considered cost-effective for the Dutch healthcare system, and their cost starts falling below the willingness-to-pay threshold after 4-5 years of use. Our analysis showed that an appropriate time horizon of health-economic analyses must be chosen to avoid potentially misleading results and detrimental decisions for patients based on too-short evaluation periods. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/46669/34863 How To Cite: Kuhlmann A, Kannenberg A. Cost-effectiveness of microprocessor-controlled prosthetic knees in the Dutch healthcare system: The impact of study duration on outcomes. Canadian Prosthetics & Orthotics Journal. 2026; Volume 9, Issue 1, No. 2. https://doi.org/10.33137/cpoj.v9i1.46669 Corresponding Author: Andreas Kannenberg, PhDAffiliation: Clinical Research & Services, Ottobock Healthcare LP, Austin, TX, USA.E-Mail: andreas.kannenberg@ottobock.comORCID ID: https://orcid.org/0000-0001-7983-1744
- Open Access
- 11 December 2024
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 49 (6) , 611-617
Retrospective cohort study of the economic value of providing microprocessor knees to the population of Medicare fee-for-service K2 beneficiaries with a knee disarticulation/above knee amputation
Background: Microprocessor knees (MPKs) improve the functional mobility, quality of life, and safety of individuals with a knee disarticulation or above knee amputation and are cost-effective when adjusting for quality-of-life years gained. However, few studies have been conducted on the K2 population, and to this point, the Centers for Medicare and Medicaid Services has not covered MPKs for the K2 population. Objectives: The aim of this study was to determine the extent to which MPK provision to the K2 population is cost effective at the person and population levels. A secondary objective was to determine the effectiveness of MPKs at reducing injurious falls within the K2 population. Study design: A retrospective cohort study using Medicare fee-for-service claims data from the Centers for Medicare and Medicaid Services. Methods: Propensity score weighting using inverse probability treatment weights was used to balance beneficiary characteristics and a generalized linear regression with log-link function and Gamma distribution was run to determine per-member-per-month cost and prosthetic device cost. A 10-year Congressional Budget Office-style score was conducted. A logistic regression was run for the fallers analysis. Results: Microprocessor knee provision to K2 beneficiaries reduced injured fallers by 18.5% and resulted in medical savings of $1,351 per-member-per-month, amortizing the $25,075 difference between the MPK and nonmicroprocessor knee in 19 months. Providing MPKs to K2 users resulted in cumulative Medicare savings of $410.3 million over 10 years. Conclusion: The MPK prosthetic device could provide meaningful safety benefits to the K2 population and result in fiscal savings to Medicare at both the person and population levels.
- 11 December 2024
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 49 (6) , 611-617
Open AccessRetrospective cohort study of the economic value of providing microprocessor knees to the population of Medicare fee-for-service K2 beneficiaries with a knee disarticulation/above knee amputation
Background: Microprocessor knees (MPKs) improve the functional mobility, quality of life, and safety of individuals with a knee disarticulation or above knee amputation and are cost-effective when adjusting for quality-of-life years gained. However, few studies have been conducted on the K2 population, and to this point, the Centers for Medicare and Medicaid Services has not covered MPKs for the K2 population. Objectives: The aim of this study was to determine the extent to which MPK provision to the K2 population is cost effective at the person and population levels. A secondary objective was to determine the effectiveness of MPKs at reducing injurious falls within the K2 population. Study design: A retrospective cohort study using Medicare fee-for-service claims data from the Centers for Medicare and Medicaid Services. Methods: Propensity score weighting using inverse probability treatment weights was used to balance beneficiary characteristics and a generalized linear regression with log-link function and Gamma distribution was run to determine per-member-per-month cost and prosthetic device cost. A 10-year Congressional Budget Office-style score was conducted. A logistic regression was run for the fallers analysis. Results: Microprocessor knee provision to K2 beneficiaries reduced injured fallers by 18.5% and resulted in medical savings of $1,351 per-member-per-month, amortizing the $25,075 difference between the MPK and nonmicroprocessor knee in 19 months. Providing MPKs to K2 users resulted in cumulative Medicare savings of $410.3 million over 10 years. Conclusion: The MPK prosthetic device could provide meaningful safety benefits to the K2 population and result in fiscal savings to Medicare at both the person and population levels.
- Open Access
- 6 August 2024
- Published by Frontiers Media SA in Frontiers in Rehabilitation Sciences
- Vol. 5, 1465671
Editorial: Advances in technology-assisted rehabilitation
- 6 August 2024
- Published by Frontiers Media SA in Frontiers in Rehabilitation Sciences
- Vol. 5, 1465671
Open AccessEditorial: Advances in technology-assisted rehabilitation
- Open Access
- 31 May 2024
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 7 (1) , 42799
PATIENTS’ BURDEN USING MICROPROCESSOR-STANCE-AND-SWING-CONTROL KNEE-ANKLE-FOOT ORTHOSES AND OUTCOMES COMPARED TO THOSE WITH PRIOR TRADITIONAL KNEE-ANKLE-FOOT-ORTHOSIS
BACKGROUND: Patients with neuromuscular knee instability who are fitted with orthotic devices experience issues such as pain, falls, mobility limitations, and restricted participation. OBJECTIVES: To analyze the burden of disease in patients using a microprocessor-stance-and-swing-control orthosis (MP-SSCO) and, if they had a previous orthosis, to compare their outcomes to those with previous use of a traditional knee-ankle-foot-orthosis (KAFO) under real-world conditions. METHODOLOGY: A structured cross-sectional survey was conducted in six orthotic and prosthetic clinics in Germany. Individuals who had been using an MP-SSCO (C-Brace) for at least six months, answered an internet-based survey to rate their current and recall previous device outcomes and experience. The questionnaire was self-developed based on established questionnaire design principles and pretested. Patients' well-being dimensions were analyzed with Likert scales. Experiences with current and previous orthotic devices were compared. Falls were analyzed both with and without outliers. FINDINGS: 21 individuals who had used a MP-SSCO for an average duration of two years participated. Fourteen patients had prior experience with a traditional KAFO orthosis. Among them, 78.6% recalled experiencing falls, with a combined annual frequency of 67.9 (SD=167.0, Median=12.0) events. After excluding the two outliers (624 and 182 falls), a mean of 12.1 falls per patient per year was reported (range: 0 to 54, SD=15.9, Median=8.5). With the MP-SSCO, only 42.7% reported falls with an annual frequency of 5.3 (SD=17.0, Median=0.0) falls (p<0.01). After excluding outliers for MP-SSCO users, the average number of falls was 0.5 per year (range 0 to 3, SD=0.9, Median=0.0). This value was significantly lower compared to the previous orthosis (p<0.01). With their previous KAFO, 57.1% of the participants reported being able to walk downstairs, 14.3% to descend stairs with reciprocal gait, and 42.9% to vary their walking speeds. In contrast, 90.5% of MP-SSCO users reported being capable of descending stairs, 81.0% reported to descend stairs with reciprocal gait (p<0.01), and 76.2% claimed they had the ability to walk with varying speeds (p=0.03). Additionally, 71.4% of the respondents experienced an improvement in their engagement in activities with the MP-SSCO. 50.0% reported pain with the previous orthosis, compared to 38.1% with the MP-SSCO. Pain intensity was higher for the previous orthosis use (3.8) compared to MP-SSCO use (2.8) on a 1-5 scale (p=0.06). 93.3% of the participants regarded the MP-SSCO as superior, noting an enhanced quality of life (QoL) compared to the previous orthosis. CONCLUSION: Advanced orthotic technology may positively impact outcomes such as fall frequency, activities of daily living, fear of falling and pain. However, in this study, results from the previous orthosis use might have been influenced by recall bias. Layman's Abstract People with an unstable knee due to nerve and muscle problems who wear orthotic devices frequently deal with issues including pain, falls, difficulty moving around, and being unable to participate in activities. We wanted to see how much these burdens affect people who used a traditional knee-ankle-foot orthosis and compare it to a newer type of brace with advanced technology. People who had been using a new microprocessor controlled device (product: C-Brace) for at least 6 months were invited to answer questions online about how they are doing with the new brace. They rated items like how they feel and their experiences with different braces. Twenty-one people who had been using the C-Brace for an average of about 2 years participated. Fourteen had used a traditional brace before. Most of them remembered falling more often with the previous brace than with the microprocessor controlled device. With the previous brace, not many could walk downstairs easily or at all, but with the C-Brace, most could. Many also said they felt less pain with the C-Brace. People with knee problems due to nerve and muscle issues have a hard time moving around and can experience falls when they use regular braces. But using newer, microprocessor controlled braces can help them move better, fall less, and feel less pain, which makes their lives better. It is important to note that results from previous use of knee-ankle-foot orthoses (KAFOs) may have been affected by memory bias. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/42799/32845 How To Cite: Brüggenjürgen B, Eilers L, Seidinger S, Kannenberg A, Stukenborg-Colsman C. Patients’ burden using microprocessor-stance-and-swing-control knee-ankle-foot orthoses and outcomes compared to those with prior traditional knee-ankle-foot-orthosis. Canadian Prosthetics & Orthotics Journal. 2024; Volume 7, Issue 1, No.1. https://doi.org/10.33137/cpoj.v7i1.42799 Corresponding Author: Prof. Dr. med. Bernd Brüggenjürgen, MPHHead Institute Health Services Research and Technical Orthopedics, Orthopedic Department - Medical School Hannover (MHH) at DIAKOVERE Annastift Hospital Anna-von-Borries-Str. 1-7, 30625 Hannover, Germany.Tel.: +49 (511) 5354 821E-Mail: brueggenjuergen.bernd@mh-hannover.de; bernd.brueggenjuergen@diakovere.deORCID ID: https://orcid.org/0000-0002-8866-0809
- 31 May 2024
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 7 (1) , 42799
Open AccessPATIENTS’ BURDEN USING MICROPROCESSOR-STANCE-AND-SWING-CONTROL KNEE-ANKLE-FOOT ORTHOSES AND OUTCOMES COMPARED TO THOSE WITH PRIOR TRADITIONAL KNEE-ANKLE-FOOT-ORTHOSIS
BACKGROUND: Patients with neuromuscular knee instability who are fitted with orthotic devices experience issues such as pain, falls, mobility limitations, and restricted participation. OBJECTIVES: To analyze the burden of disease in patients using a microprocessor-stance-and-swing-control orthosis (MP-SSCO) and, if they had a previous orthosis, to compare their outcomes to those with previous use of a traditional knee-ankle-foot-orthosis (KAFO) under real-world conditions. METHODOLOGY: A structured cross-sectional survey was conducted in six orthotic and prosthetic clinics in Germany. Individuals who had been using an MP-SSCO (C-Brace) for at least six months, answered an internet-based survey to rate their current and recall previous device outcomes and experience. The questionnaire was self-developed based on established questionnaire design principles and pretested. Patients' well-being dimensions were analyzed with Likert scales. Experiences with current and previous orthotic devices were compared. Falls were analyzed both with and without outliers. FINDINGS: 21 individuals who had used a MP-SSCO for an average duration of two years participated. Fourteen patients had prior experience with a traditional KAFO orthosis. Among them, 78.6% recalled experiencing falls, with a combined annual frequency of 67.9 (SD=167.0, Median=12.0) events. After excluding the two outliers (624 and 182 falls), a mean of 12.1 falls per patient per year was reported (range: 0 to 54, SD=15.9, Median=8.5). With the MP-SSCO, only 42.7% reported falls with an annual frequency of 5.3 (SD=17.0, Median=0.0) falls (p<0.01). After excluding outliers for MP-SSCO users, the average number of falls was 0.5 per year (range 0 to 3, SD=0.9, Median=0.0). This value was significantly lower compared to the previous orthosis (p<0.01). With their previous KAFO, 57.1% of the participants reported being able to walk downstairs, 14.3% to descend stairs with reciprocal gait, and 42.9% to vary their walking speeds. In contrast, 90.5% of MP-SSCO users reported being capable of descending stairs, 81.0% reported to descend stairs with reciprocal gait (p<0.01), and 76.2% claimed they had the ability to walk with varying speeds (p=0.03). Additionally, 71.4% of the respondents experienced an improvement in their engagement in activities with the MP-SSCO. 50.0% reported pain with the previous orthosis, compared to 38.1% with the MP-SSCO. Pain intensity was higher for the previous orthosis use (3.8) compared to MP-SSCO use (2.8) on a 1-5 scale (p=0.06). 93.3% of the participants regarded the MP-SSCO as superior, noting an enhanced quality of life (QoL) compared to the previous orthosis. CONCLUSION: Advanced orthotic technology may positively impact outcomes such as fall frequency, activities of daily living, fear of falling and pain. However, in this study, results from the previous orthosis use might have been influenced by recall bias. Layman's Abstract People with an unstable knee due to nerve and muscle problems who wear orthotic devices frequently deal with issues including pain, falls, difficulty moving around, and being unable to participate in activities. We wanted to see how much these burdens affect people who used a traditional knee-ankle-foot orthosis and compare it to a newer type of brace with advanced technology. People who had been using a new microprocessor controlled device (product: C-Brace) for at least 6 months were invited to answer questions online about how they are doing with the new brace. They rated items like how they feel and their experiences with different braces. Twenty-one people who had been using the C-Brace for an average of about 2 years participated. Fourteen had used a traditional brace before. Most of them remembered falling more often with the previous brace than with the microprocessor controlled device. With the previous brace, not many could walk downstairs easily or at all, but with the C-Brace, most could. Many also said they felt less pain with the C-Brace. People with knee problems due to nerve and muscle issues have a hard time moving around and can experience falls when they use regular braces. But using newer, microprocessor controlled braces can help them move better, fall less, and feel less pain, which makes their lives better. It is important to note that results from previous use of knee-ankle-foot orthoses (KAFOs) may have been affected by memory bias. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/42799/32845 How To Cite: Brüggenjürgen B, Eilers L, Seidinger S, Kannenberg A, Stukenborg-Colsman C. Patients’ burden using microprocessor-stance-and-swing-control knee-ankle-foot orthoses and outcomes compared to those with prior traditional knee-ankle-foot-orthosis. Canadian Prosthetics & Orthotics Journal. 2024; Volume 7, Issue 1, No.1. https://doi.org/10.33137/cpoj.v7i1.42799 Corresponding Author: Prof. Dr. med. Bernd Brüggenjürgen, MPHHead Institute Health Services Research and Technical Orthopedics, Orthopedic Department - Medical School Hannover (MHH) at DIAKOVERE Annastift Hospital Anna-von-Borries-Str. 1-7, 30625 Hannover, Germany.Tel.: +49 (511) 5354 821E-Mail: brueggenjuergen.bernd@mh-hannover.de; bernd.brueggenjuergen@diakovere.deORCID ID: https://orcid.org/0000-0002-8866-0809
- Open Access
- 1 January 2024
- Published by SAGE Publications in Journal of Rehabilitation and Assistive Technologies Engineering
- Vol. 11
The C-Brace® microprocessor controlled stance and swing orthosis improves safety, mobility, and quality of life at one year: Interim results from a prospective registry
Introduction: The C-Brace microprocessor-controlled stance and swing control orthosis has been shown to improve function, mobility, and quality of life. A systematic registry to gather long-term, real-world safety and effectiveness data in patients fit with a C-Brace has not been performed. Methods: International multicenter registry. Patients undergoing routine C-Brace fittings were assessed at baseline and 1 year after fitting. Primary outcomes were fast walking speed (FWS) measured by 25-foot or 10-meter walk test, Timed Up and Go (TUG) and the Activity-specific Balance Confidence (ABC) Scale. Secondary and exploratory outcomes included the Patient-specific Functional Scale (PSFS), falls, pain, PROMIS Pain Interference (PI), and quality of life. Results: 48 subjects with 1-year baseline and follow up data were analyzed. With the C-Brace, FWS improved by + 0.26 ± 0.33 m/s ( p < .0001), TUG by −8.1 ± 14.6 sec ( p < .0001), and ABC by + 24.9 ± 25.8% ( p < .0001). Mean falls reduced from 33 ± 77 to 3.0 ± 5.6 ( p = .0005). PSFS increased by 3.60 ± 2.34 points ( p < .0001). Outcomes for pain, PI and quality of life showed significant improvements with the C-Brace. Conclusion: The C-Brace is an effective option to improve safety, mobility, and quality of life for patients needing a KAFO for ambulation.
- 1 January 2024
- Published by SAGE Publications in Journal of Rehabilitation and Assistive Technologies Engineering
- Vol. 11
Open AccessThe C-Brace® microprocessor controlled stance and swing orthosis improves safety, mobility, and quality of life at one year: Interim results from a prospective registry
Introduction: The C-Brace microprocessor-controlled stance and swing control orthosis has been shown to improve function, mobility, and quality of life. A systematic registry to gather long-term, real-world safety and effectiveness data in patients fit with a C-Brace has not been performed. Methods: International multicenter registry. Patients undergoing routine C-Brace fittings were assessed at baseline and 1 year after fitting. Primary outcomes were fast walking speed (FWS) measured by 25-foot or 10-meter walk test, Timed Up and Go (TUG) and the Activity-specific Balance Confidence (ABC) Scale. Secondary and exploratory outcomes included the Patient-specific Functional Scale (PSFS), falls, pain, PROMIS Pain Interference (PI), and quality of life. Results: 48 subjects with 1-year baseline and follow up data were analyzed. With the C-Brace, FWS improved by + 0.26 ± 0.33 m/s ( p < .0001), TUG by −8.1 ± 14.6 sec ( p < .0001), and ABC by + 24.9 ± 25.8% ( p < .0001). Mean falls reduced from 33 ± 77 to 3.0 ± 5.6 ( p = .0005). PSFS increased by 3.60 ± 2.34 points ( p < .0001). Outcomes for pain, PI and quality of life showed significant improvements with the C-Brace. Conclusion: The C-Brace is an effective option to improve safety, mobility, and quality of life for patients needing a KAFO for ambulation.
- Open Access
- 28 January 2022
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 19 (1) , 1-12
Benefits of a microprocessor-controlled prosthetic foot for ascending and descending slopes
Background: Prosthetic feet are prescribed for persons with a lower-limb amputation to restore lost mobility. However, due to limited adaptability of their ankles and springs, situations like walking on slopes or uneven ground remain challenging. This study investigated to what extent a microprocessor-controlled prosthetic foot (MPF) facilitates walking on slopes. Methods: Seven persons each with a unilateral transtibial amputation (TTA) and unilateral transfemoral amputation (TFA) as well as ten able-bodied subjects participated. Participants were studied while using a MPF and their prescribed standard feet with fixed ankle attachments. The study investigated ascending and descending a 10° slope. Kinematic and kinetic data were recorded with a motion capture system. Biomechanical parameters, in particular leg joint angles, shank orientation and external joint moments of the prosthetics side were calculated. Results: Prosthetic feet- and subject group-dependent joint angle and moment characteristics were observed for both situations. The MPF showed a larger and situation-dependent ankle range of motion compared to the standard feet. Furthermore, it remained in a dorsiflexed position during swing. While ascending, the MPF adapted the dorsiflexion moment and reduced the knee extension moment. At vertical shank orientation, it reduced the knee extension moment by 26% for TFA and 49% for TTA compared to the standard feet. For descending, differences between feet in the biomechanical knee characteristics were found for the TTA group, but not for the TFA group. At the vertical shank angle during slope descent, TTA demonstrated a behavior of the ankle moment similar to able-bodied controls when using the MPF. Conclusions: The studied MPF facilitated walking on slopes by adapting instantaneously to inclinations and, thus, easing the forward rotation of the leg over the prosthetic foot compared to standard feet with a fixed ankle attachment with amputation-level dependent effect sizes. It assumed a dorsiflexed ankle angle during swing, enabled a larger ankle range of motion and reduced the moments acting on the residual knee of TTA compared to the prescribed prosthetic standard feet. For individuals with TFA, the prosthetic knee joint seems to play a more crucial role for walking on ramps than the foot.
- 28 January 2022
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 19 (1) , 1-12
Open AccessBenefits of a microprocessor-controlled prosthetic foot for ascending and descending slopes
Background: Prosthetic feet are prescribed for persons with a lower-limb amputation to restore lost mobility. However, due to limited adaptability of their ankles and springs, situations like walking on slopes or uneven ground remain challenging. This study investigated to what extent a microprocessor-controlled prosthetic foot (MPF) facilitates walking on slopes. Methods: Seven persons each with a unilateral transtibial amputation (TTA) and unilateral transfemoral amputation (TFA) as well as ten able-bodied subjects participated. Participants were studied while using a MPF and their prescribed standard feet with fixed ankle attachments. The study investigated ascending and descending a 10° slope. Kinematic and kinetic data were recorded with a motion capture system. Biomechanical parameters, in particular leg joint angles, shank orientation and external joint moments of the prosthetics side were calculated. Results: Prosthetic feet- and subject group-dependent joint angle and moment characteristics were observed for both situations. The MPF showed a larger and situation-dependent ankle range of motion compared to the standard feet. Furthermore, it remained in a dorsiflexed position during swing. While ascending, the MPF adapted the dorsiflexion moment and reduced the knee extension moment. At vertical shank orientation, it reduced the knee extension moment by 26% for TFA and 49% for TTA compared to the standard feet. For descending, differences between feet in the biomechanical knee characteristics were found for the TTA group, but not for the TFA group. At the vertical shank angle during slope descent, TTA demonstrated a behavior of the ankle moment similar to able-bodied controls when using the MPF. Conclusions: The studied MPF facilitated walking on slopes by adapting instantaneously to inclinations and, thus, easing the forward rotation of the leg over the prosthetic foot compared to standard feet with a fixed ankle attachment with amputation-level dependent effect sizes. It assumed a dorsiflexed ankle angle during swing, enabled a larger ankle range of motion and reduced the moments acting on the residual knee of TTA compared to the prescribed prosthetic standard feet. For individuals with TFA, the prosthetic knee joint seems to play a more crucial role for walking on ramps than the foot.
- Open Access
- 16 January 2022
- Published by Wolters Kluwer Health in JPO Journal of Prosthetics and Orthotics
- Vol. 35 (1) , 38-43
Differences in Two Multiarticulating Myoelectric Hands for Facilitating Activities of Daily Living in Individuals with Transradial Amputation: A Cross-Sectional Study
Introduction: Research with multiarticulating prosthetic hands on patient-reported ease of activities of daily living (ADLs) and usefulness is still limited. This study aimed at comparing ease of ADL performance and usefulness of two common multiarticulating prosthetic hands. Methods: Twenty subjects with transradial amputation wearing the bebionic (n = 10) or i-Limb (n = 10) hands were assessed with a hybrid Orthotics and Prosthetics User Survey–Upper Extremity Functional Status (OPUS-UEFS)/Prosthetic Upper Extremity Functional Index (PUFI) outcome measure previously used in a study with another multigrip prosthetic hand. Results: There were no significant differences between the bebionic and i-Limb hands. However, the analysis of individual activities revealed that each multiarticulating hand had specific strengths and weaknesses compared with a historic control group with conventional myoelectric hands. Discussion: Both multiarticulating hands may improve ease of performing ADLs compared with conventional myoelectric hands. However, more grip types available do not necessarily result in greater ease or usefulness compared with advanced hands with fewer grip types. Conclusions: Clinicians must match the patients' functional needs with the differential functional profiles of the available multiarticulating hands. Clinical Relevance: The present study is the first to provide comparative patient-reported outcomes on 3 multigrip prosthetic hands as well as standard myoelectric hands in 23 common ADLs. The distinct patient-reported ease and usefulness profiles of the different hands may inform and support clinicians' decision-making on hand selection for individual patients with transradial amputation.
- 16 January 2022
- Published by Wolters Kluwer Health in JPO Journal of Prosthetics and Orthotics
- Vol. 35 (1) , 38-43
Open AccessDifferences in Two Multiarticulating Myoelectric Hands for Facilitating Activities of Daily Living in Individuals with Transradial Amputation: A Cross-Sectional Study
Introduction: Research with multiarticulating prosthetic hands on patient-reported ease of activities of daily living (ADLs) and usefulness is still limited. This study aimed at comparing ease of ADL performance and usefulness of two common multiarticulating prosthetic hands. Methods: Twenty subjects with transradial amputation wearing the bebionic (n = 10) or i-Limb (n = 10) hands were assessed with a hybrid Orthotics and Prosthetics User Survey–Upper Extremity Functional Status (OPUS-UEFS)/Prosthetic Upper Extremity Functional Index (PUFI) outcome measure previously used in a study with another multigrip prosthetic hand. Results: There were no significant differences between the bebionic and i-Limb hands. However, the analysis of individual activities revealed that each multiarticulating hand had specific strengths and weaknesses compared with a historic control group with conventional myoelectric hands. Discussion: Both multiarticulating hands may improve ease of performing ADLs compared with conventional myoelectric hands. However, more grip types available do not necessarily result in greater ease or usefulness compared with advanced hands with fewer grip types. Conclusions: Clinicians must match the patients' functional needs with the differential functional profiles of the available multiarticulating hands. Clinical Relevance: The present study is the first to provide comparative patient-reported outcomes on 3 multigrip prosthetic hands as well as standard myoelectric hands in 23 common ADLs. The distinct patient-reported ease and usefulness profiles of the different hands may inform and support clinicians' decision-making on hand selection for individual patients with transradial amputation.
- Open Access
- 14 January 2022
- Published by Frontiers Media SA in Frontiers in Rehabilitation Sciences
- Vol. 2, 805151
Free-Living User Perspectives on Musculoskeletal Pain and Patient-Reported Mobility With Passive and Powered Prosthetic Ankle-Foot Components: A Pragmatic, Exploratory Cross-Sectional Study
Introduction: Studies with a powered prosthetic ankle-foot (PwrAF) found a reduction in sound knee loading compared to passive feet. Therefore, the aim of the present study was to determine whether anecdotal reports on reduced musculoskeletal pain and improved patient-reported mobility were isolated occurrences or reflect a common experience in PwrAF users.Methods: Two hundred and fifty individuals with transtibial amputation (TTA) who had been fitted a PwrAF in the past were invited to an online survey on average sound knee, amputated side knee, and low-back pain assessed with numerical pain rating scales (NPRS), the PROMIS Pain Interference scale, and the PLUS-M for patient-reported mobility in the free-living environment. Subjects rated their current foot and recalled the ratings for their previous foot. Recalled scores were adjusted for recall bias by clinically meaningful amounts following published recommendations. Statistical comparisons were performed using Wilcoxon's signed rank test.Results: Forty-six subjects, all male, with unilateral TTA provided data suitable for analysis. Eighteen individuals (39%) were current PwrAF users, whereas 28 subjects (61%) had reverted to a passive foot. After adjustment for recall bias, current PwrAF users reported significantly less sound knee pain than they recalled for use of a passive foot (−0.5 NPRS, p = 0.036). Current PwrAF users who recalled sound knee pain ≥4 NPRS with a passive foot reported significant and clinically meaningful improvements in sound knee pain (−2.5 NPRS, p = 0.038) and amputated side knee pain (−3 NPRS, p = 0.042). Current PwrAF users also reported significant and clinically meaningful improvements in patient-reported mobility (+4.6 points PLUS-M, p = 0.016). Individuals who had abandoned the PwrAF did not recall any differences between the feet.Discussion: Current PwrAF users reported significant and clinically meaningful improvements in patient-reported prosthetic mobility as well as sound knee and amputated side knee pain compared to recalled mobility and pain with passive feet used previously. However, a substantial proportion of individuals who had been fitted such a foot in the past did not recall improvements and had reverted to passive feet. The identification of individuals with unilateral TTA who are likely to benefit from a PwrAF remains a clinical challenge and requires further research.
- 14 January 2022
- Published by Frontiers Media SA in Frontiers in Rehabilitation Sciences
- Vol. 2, 805151
Open AccessFree-Living User Perspectives on Musculoskeletal Pain and Patient-Reported Mobility With Passive and Powered Prosthetic Ankle-Foot Components: A Pragmatic, Exploratory Cross-Sectional Study
Introduction: Studies with a powered prosthetic ankle-foot (PwrAF) found a reduction in sound knee loading compared to passive feet. Therefore, the aim of the present study was to determine whether anecdotal reports on reduced musculoskeletal pain and improved patient-reported mobility were isolated occurrences or reflect a common experience in PwrAF users.Methods: Two hundred and fifty individuals with transtibial amputation (TTA) who had been fitted a PwrAF in the past were invited to an online survey on average sound knee, amputated side knee, and low-back pain assessed with numerical pain rating scales (NPRS), the PROMIS Pain Interference scale, and the PLUS-M for patient-reported mobility in the free-living environment. Subjects rated their current foot and recalled the ratings for their previous foot. Recalled scores were adjusted for recall bias by clinically meaningful amounts following published recommendations. Statistical comparisons were performed using Wilcoxon's signed rank test.Results: Forty-six subjects, all male, with unilateral TTA provided data suitable for analysis. Eighteen individuals (39%) were current PwrAF users, whereas 28 subjects (61%) had reverted to a passive foot. After adjustment for recall bias, current PwrAF users reported significantly less sound knee pain than they recalled for use of a passive foot (−0.5 NPRS, p = 0.036). Current PwrAF users who recalled sound knee pain ≥4 NPRS with a passive foot reported significant and clinically meaningful improvements in sound knee pain (−2.5 NPRS, p = 0.038) and amputated side knee pain (−3 NPRS, p = 0.042). Current PwrAF users also reported significant and clinically meaningful improvements in patient-reported mobility (+4.6 points PLUS-M, p = 0.016). Individuals who had abandoned the PwrAF did not recall any differences between the feet.Discussion: Current PwrAF users reported significant and clinically meaningful improvements in patient-reported prosthetic mobility as well as sound knee and amputated side knee pain compared to recalled mobility and pain with passive feet used previously. However, a substantial proportion of individuals who had been fitted such a foot in the past did not recall improvements and had reverted to passive feet. The identification of individuals with unilateral TTA who are likely to benefit from a PwrAF remains a clinical challenge and requires further research.
- Open Access
- 25 October 2021
- Published by Taylor & Francis in Disability and Rehabilitation
- Vol. 44 (24) , 7349-7367
The effect of microprocessor controlled exo-prosthetic knees on limited community ambulators: systematic review and meta-analysis
The clinical benefits of microprocessor-controlled prosthetic knees (MPKs) in community ambulators have been well-established. A systematic review in limited community ambulators published in 2014 ...
- 25 October 2021
- Published by Taylor & Francis in Disability and Rehabilitation
- Vol. 44 (24) , 7349-7367
Open AccessThe effect of microprocessor controlled exo-prosthetic knees on limited community ambulators: systematic review and meta-analysis
The clinical benefits of microprocessor-controlled prosthetic knees (MPKs) in community ambulators have been well-established. A systematic review in limited community ambulators published in 2014 ...