JGJeremy Gummeson

Jeremy Gummeson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jeremy Gummeson has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Demo: Phonotonos: Through-Skin Ultrasonic Blood Flow Sensing Using Smartphones

    by Rishav Gupta, Shirui Cao, Jie Xiong, Sunghoon Ivan Lee, Jeremy Gummeson, Dong Li

  • Open Access

    [Emerging Ideas] Phonotonos: Through-Skin Ultrasonic Blood Flow Sensing Using Smartphones

    by Shirui Cao, Jie Xiong, Riishav Guptaa, Sunghoon Ivan Lee, Jeremy Gummeson, Dong Li


  • Open Access

    [Emerging Ideas] Towards Practical Metabolic Sensing with Wearable TEGs

    by Bosco Nkurunziza, Antoine Nzeyimana, Luke Arieta, Michael Busa, Jeremy Gummeson

  • Open Access

    Embedded Smart Insole for Accurate Gait Event Detection

    by Jean Bosco Nkurunziza, Ross Brancati, Ramzi Majaj, Jeremy Gummeson, Michael Busa

    This paper presents the design, implementation, and validation of a low-power smart insole system for gait event detection, with a focus on stance, swing, and step durations. Plantar pressure signals, captured via force-sensing resistors embedded in the heel and toe regions, were processed using a centered rolling mean and analyzed through a threshold-based detection algorithm. Ground-truth annotations were obtained from a time synchronized Qualisys motion capture system. Across 14 participants, covering more than 1,200 gait cycles at five controlled walking speeds, the insole-based algorithm demonstrated high accuracy in detecting heel-strike (HS) and toe-off (TO) events. Bland-Altman analysis revealed that stance and swing durations exhibited small speed-dependent biases (mean percent error < 10%) that diminished at faster walking speeds, while step durations showed near-zero bias with tight dispersion (ρ ±1%). Correlation analysis confirmed strong agreement with motion capture across all metrics ( r > 0.95). These results indicate that despite simplified sensing hardware and cost-efficient design, the system achieves robust gait characterization sufficient for ambulatory monitoring and longitudinal assessment in real-world environments.


  • Mobile and Multi-Device Wireless Charging

    by Lili Chen, Bozhong Yu, Yongjian Fu, Ju Ren, Hao Pan, Jeremy Gummeson, Ling Wang, Yaoxue Zhang

    Wireless charging is a cornerstone technology for next-generation mobile and ubiquitous computing. However, its practical deployment has long been constrained by short range, poor flexibility, and lack of support for dynamic multi-device scenarios. In this paper, we propose ChargeX—a system that enables long-range and mobility-resilient wireless charging for multiple small devices. ChargeX pioneers the integration of metasurface-assisted magnetic beamforming, a high-frequency compact transceiver design, and a real-time closed-loop feedback-control mechanism. It further advances the field by introducing a joint optimization framework for dynamically allocating energy across mobile receivers with heterogeneous priorities and spatial-temporal demands. Experimental results demonstrate that it achieves meter-level charging distance, real-time response to device movement, and efficient coordination among multiple receivers, significantly outperforming state-of-the-art prototypes.


  • Open Access

    An Intra-Body Power Transfer System via Localized Capacitive Coupling

    by Noor Mohammed, Sunghoon Ivan Lee, Robert W. Jackson, Jeremy Gummeson

    Intra-body power transfer (IBPT) enables batteryless wearables by using the human body as a conductive medium. This work introduces Localized Capacitive Coupling (LCC), a new IBPT technique that uses a 40 MHz RF carrier to provide power transfer without relying on external grounds or environmental infrastructure. We evaluate LCC using computational modeling and human subject experiments with ten participants across multiple short-range capacitive body channels. Laboratory measurements with an isolated electrode system show mean path gains of 44 dB to 48 dB for channel lengths of 5 to 12 cm, closely matching our computational model with deviations under 3 dB. Circuit analysis indicates that air-gap coupling capacitance, typically in the femtofarad range, dominates channel gain, highlighting the importance of short-range fringing fields. To demonstrate practical energy harvesting, we designed and evaluated multistage Dickson charge pump (DCP) receivers. A five-stage impedance-matched DCP produced 3 V DC at 13.5 \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{upgreek} \usepackage{mathrsfs} \setlength{\oddsidemargin}{-69pt} $\pm$ 0.5 dBm of incident RF power across a load in the tens of megaohms. A single-stage DCP paired with a battery manager generated a regulated 1.8 V output by charging a 100 \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{upgreek} \usepackage{mathrsfs} \setlength{\oddsidemargin}{-69pt} $\mu F$ capacitor from RF peak powers as low as 18.5 dBm. These results enabled a fully batteryless ring-worn motion sensor that uses an ultra-low-power accelerometer and non-volatile memory for offline activity logging, demonstrating that LCC is a practical approach for powering short-range wearable sensor networks. All hardware designs and simulation configurations will be open-sourced upon publication.

  • Open Access

    Acoustoscillogram: Unlocking Arterial Health Insights via Acoustic Sensing with Low-cost Wired Earphones

    by Xiaoxuan Liang, Zhaolong Wei, Shirui Cao, Quan Zhang, Longfei Shangguan, Dong Li, Jeremy Gummeson

    Cardiovascular disease is a leading cause of mortality worldwide and a major contributor to rising healthcare costs. Early detection of arterial stiffness through metrics such as Pulse Wave Velocity (PWV) and Augmentation Index (AIx) is essential for cardiovascular disease prevention and treatment. However, conventional measurement methods typically require expensive, specialized equipment and clinical settings. In this paper, we explore the use of everyday earphones to monitor PWV and AIx in daily life by capturing skin displacement waveforms induced by arterial pulsation. However, several key challenges must be addressed. First, detecting subtle skin displacement is difficult due to strong self-interference from the speaker to microphone. To address this, we propose a Doppler shift-based displacement estimation approach to isolate dynamic movements from static interference. Second, estimating PWV requires simultaneous two-point measurements, which is non-trivial with standard earphones. We address this with a hardware-software co-design that connects two earphone pairs via a commercial audio splitter and uses orthogonal frequency division multiplexing (OFDM)-based signal separation to extract displacement signals from both sites. Third, enabling general public use without medical training requires thoughtful system design. To this end, we develop a user-friendly mobile application that provides real-time feedback, along with a 3D-printed enclosure to facilitate ease of use and wide accessibility. We conducted IRB-approved clinical studies with 32 participants, comparing our measurements against ground truths from medical devices. Results show that our method achieves a PWV error of less than 0.5 m/s and an AIx error of less than 4%, meeting established medical standards. Please find the demo of our system here .


  • Pushing Seamless Wireless Communication With Cross-Band Metasurfaces

    by Lili Chen, Zhaolin Zhang, Bozhong Yu, Yizhe Zhao, Ju Ren, Jeremy Gummeson, Yaoxue Zhang

    In the realm of next-generation wireless communications, sub-6GHz and mmWave frequencies are a powerful combination, offering broad coverage and high capacity. Nevertheless, achieving seamless wireless connections in indoor environments remains a challenge, primarily due to obstructions that significantly impact higher frequency bands such as Wi-Fi 5GHz and mmWave. Bridging this divide requires an innovative approach, and economical tunable metasurfaces emerge as a promising solution. These metasurfaces can redirect incoming wave directions to circumvent obstacles. However, existing metasurface technologies are typically tailored to a single frequency band and lack a theoretical framework for designing surfaces that cater to multiple desired bands, constraining their potential for versatile applications. This work takes on the challenge of providing a comprehensive approach to cross-band metasurface design, with the overarching goal of expanding the reach of wireless network. We introduce a novel metasurface prototype named CrossMeta, engineered to optimize link quality while efficiently utilizing apertures and maintaining cost-effectiveness. We tacked a series of challenges to empower CrossMeta to independently manipulate wireless communication links across multiple frequency bands; our proof of concept implementation is for Wi-Fi 5 GHz and mmWave bands. We integrate a fast beam-scanning algorithm into an end-to-end system that actuates the metasurface to optimize links in real-time. Empirical evaluation demonstrates that CrossMeta can enhance multiple wireless links simultaneously, providing 10 dB and 15 dB power improvements for Wi-Fi and mmWave links, respectively. Impressively, CrossMeta achieves less than 4° beam mismatch even in challenging mobile scenarios.


  • A Capacitive Backscatter System for Intra-Body Identification

    by Noor Mohammed, Robert W. Jackson, Sunghoon Ivan Lee, Jeremy Gummeson

    In this paper, we present a new intra-body communication technology that uses capacitive backscatter. The main goal of this technology is to allow for the transmission of binary IDs between a skin-coupled transceiver and a batteryless tag by utilizing finite conductivity of skin and air coupling capacitance. The intra-body identification (IBID) hardware system consists of two pairs of skin-coupled 50 ohm galvanically isolated electrodes: the interrogator(fixed size: 30 cm $\times $ 40 cm) and the tag (arbitrary shape and size). The flexibility of electrode shape enables the IBID tag to be easily deployed on various everyday objects. The interrogator is connected to a battery-powered wearable transceiver. The study investigated the capacitive backscatter phenomenon using two everyday object models: a remote control model and a rectangular single switch panel. The experimental results demonstrate the hardware system’s ability to interrogate binary IDs seamlessly using 40 MHz pulsed radio frequency (RF) carrier with 33% duty cycle. However, the variable dimensions of the tag electrode lead to varying path gain within a short body channel, resulting in low available power for the tag. To address this challenge, we developed an ultra-low powered IBID tag that can sustain its operation at $-11~dBm$ peak RF power and transmit multiple bursts of 16-bit binary packets.