Dee Zhen Lim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dee Zhen Lim has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
Numan Kutaiba
Department of Radiology, Austin Health, Heidelberg, Australia
3 shared publicationsAshu Jhamb
12Department of Radiology, St Vincent Health, Fitzroy, Victoria, Australia
2 shared publicationsChristen Barras
13School of Medicine, University of Adelaide, Adelaide, South Australia, Australia
2 shared publicationsHamed Asadi
Department of Radiology, Austin Health, Heidelberg, Victoria, Australia
2 shared publicationsHong Kuan Kok
Department of Radiology, Northern Health, Epping, Victoria, Australia
2 shared publicationsJulian Maingard
Department of Radiology, Monash Health, Clayton, Victoria, Australia
2 shared publications
Latest Publications
- 5 August 2024
- Published by Wiley in Anz Journal of Surgery
- Vol. 94 (12) , 2195-2200
Measurement of the distal bile duct density on computed tomography can differentiate choledocholithiasis from a control population
Purpose: Hounsfield unit density of biliary fluid on CT may be a useful clinical marker that has not been described in the literature. This method has been used to differentiate pyonephrosis from hydronephrosis in obstructed collecting systems of the kidney. We aimed to create a user‐friendly technique to measure the density of the distal bile duct using CT. The bile duct density of cases with proven choledocholithiasis at ERCP were compared with those of a control group (no biliary pathology).Methods: A total of 106 patients with proven choledocholithiasis at ERCP and 50 control patients were analysed. The distal bile duct density was calculated using the 4‐point and max ellipse methods. Two blinded, independent investigators calculated the bile duct density.Results: The HU is significantly higher in the presence of choledocholithiasis (P < 0.0001). Using the Youden index a cut‐off value of 28.6 HU for the 4‐point technique is useful to predict the presence of choledocholithiasis (Sensitivity 58%, Specificity 86%).Conclusion: Calculation of the distal bile duct density can differentiate choledocholithiasis from a control population. It may be useful alone or as a component of a scoring system to select patients more effectively for intervention. The improved use of CT may also decrease use of MRCP and reduce time to ERCP, which have potential cost benefits.
- 5 August 2024
- Published by Wiley in Anz Journal of Surgery
- Vol. 94 (12) , 2195-2200
Measurement of the distal bile duct density on computed tomography can differentiate choledocholithiasis from a control population
Purpose: Hounsfield unit density of biliary fluid on CT may be a useful clinical marker that has not been described in the literature. This method has been used to differentiate pyonephrosis from hydronephrosis in obstructed collecting systems of the kidney. We aimed to create a user‐friendly technique to measure the density of the distal bile duct using CT. The bile duct density of cases with proven choledocholithiasis at ERCP were compared with those of a control group (no biliary pathology).Methods: A total of 106 patients with proven choledocholithiasis at ERCP and 50 control patients were analysed. The distal bile duct density was calculated using the 4‐point and max ellipse methods. Two blinded, independent investigators calculated the bile duct density.Results: The HU is significantly higher in the presence of choledocholithiasis (P < 0.0001). Using the Youden index a cut‐off value of 28.6 HU for the 4‐point technique is useful to predict the presence of choledocholithiasis (Sensitivity 58%, Specificity 86%).Conclusion: Calculation of the distal bile duct density can differentiate choledocholithiasis from a control population. It may be useful alone or as a component of a scoring system to select patients more effectively for intervention. The improved use of CT may also decrease use of MRCP and reduce time to ERCP, which have potential cost benefits.
- 16 May 2024
- Published by Springer Nature in Skeletal Radiology
- Vol. 54 (1) , 33-40
Opportunistic screening for osteoporosis using routine clinical care computed tomography brain studies
Objective Osteoporosis and falls are both prevalent in the elderly, and CT brain (CTB) is frequently performed post head-strike. We aim to validate the relationship between frontal bone density (Hounsfield unit) from routine CTB and bone mineral density from dual-energy X-ray absorptiometry (DEXA) scan for opportunistic osteoporosis screening. Materials and methods Patients who had a non-contrast CTB followed by a DEXA scan in the subsequent year were included in this multi-center retrospective study. The relationship between frontal bone density on CT and femoral neck T-score on DEXA was examined using ANOVA, Pearson’s correlation, and receiver operating curve (ROC) analysis. Sensitivity, specificity, negative and positive predictive values, and area under the curve (AUC) were calculated. Results Three hundred twenty-six patients (205 females and 121 males) were analyzed. ANOVA analysis showed that frontal bone density was lower in patients with DEXA-defined osteoporosis (p < 0.001), while Pearson’s correlation analysis demonstrated a fair correlation with femoral neck T-score (r = 0.3, p < 0.001). On subgroup analysis, these were true in females but not in males. On ROC analysis, frontal bone density weakly predicted osteoporosis (AUC 0.6, 95% CI 0.5–0.7) with no optimal threshold identified. HU < 610 was highly specific (87.5%) but poorly sensitive (18.9%). HU > 1200 in females had a strong negative predictive value for osteoporosis (92.6%, 95% CI 87.1–98.1%). Conclusion Frontal bone density from routine CTB is significantly different between females with and without osteoporosis, but not between males. However, frontal bone density was a weak predictor for DEXA-defined osteoporosis. Further research is required to determine the role of CTB in opportunistic osteoporosis screening.
- 16 May 2024
- Published by Springer Nature in Skeletal Radiology
- Vol. 54 (1) , 33-40
Opportunistic screening for osteoporosis using routine clinical care computed tomography brain studies
Objective Osteoporosis and falls are both prevalent in the elderly, and CT brain (CTB) is frequently performed post head-strike. We aim to validate the relationship between frontal bone density (Hounsfield unit) from routine CTB and bone mineral density from dual-energy X-ray absorptiometry (DEXA) scan for opportunistic osteoporosis screening. Materials and methods Patients who had a non-contrast CTB followed by a DEXA scan in the subsequent year were included in this multi-center retrospective study. The relationship between frontal bone density on CT and femoral neck T-score on DEXA was examined using ANOVA, Pearson’s correlation, and receiver operating curve (ROC) analysis. Sensitivity, specificity, negative and positive predictive values, and area under the curve (AUC) were calculated. Results Three hundred twenty-six patients (205 females and 121 males) were analyzed. ANOVA analysis showed that frontal bone density was lower in patients with DEXA-defined osteoporosis (p < 0.001), while Pearson’s correlation analysis demonstrated a fair correlation with femoral neck T-score (r = 0.3, p < 0.001). On subgroup analysis, these were true in females but not in males. On ROC analysis, frontal bone density weakly predicted osteoporosis (AUC 0.6, 95% CI 0.5–0.7) with no optimal threshold identified. HU < 610 was highly specific (87.5%) but poorly sensitive (18.9%). HU > 1200 in females had a strong negative predictive value for osteoporosis (92.6%, 95% CI 87.1–98.1%). Conclusion Frontal bone density from routine CTB is significantly different between females with and without osteoporosis, but not between males. However, frontal bone density was a weak predictor for DEXA-defined osteoporosis. Further research is required to determine the role of CTB in opportunistic osteoporosis screening.
- Open Access
- 27 January 2023
- Published by Springer Nature in BMC Research Notes
- Vol. 16 (1) , 1-6
Clinical and financial impacts of abnormal liver biochemistry after liver transplantation
Objective: After liver transplant (LT), many investigations are needed to evaluate abnormal liver function test (LFT), which has poor specificity for graft function and complication. A single center retrospective audit of all adult single organ LT from 1/1/2015 to 31/12/2017 was performed. Demographic, clinical and investigation data from the LT database and electronic medical records and cost data from the hospital’s Business Intelligence Unit were analyzed. Patients were classified into uncomplicated or complicated LFT by 2 independent investigators and the number, type, and cost of investigations in the first 30 post-operative days were analyzed. Investigations prior to liver biopsy was sub-analyzed. Results: There was 170 LT with 87 cases of uncomplicated LFT (51.2%) and 83 cases of complicated LFT (48.8%). Most patients with complicated LFT had additional investigations (97.6%), most commonly cholangiogram (55.4%) and liver biopsy (LBx) (50.6%). The additional investigations cost was $1863.3 (95% CI 1289.0–2437.6). Although most LBx (73.8%) showed evidence of rejection, LBx was often not the initial investigation of choice. Current LFT based post-transplant monitoring is inefficient. It remains difficult to determine which patient will benefit from an early invasive procedure like LBx, using LFT alone without further imaging investigations.
- 27 January 2023
- Published by Springer Nature in BMC Research Notes
- Vol. 16 (1) , 1-6
Open AccessClinical and financial impacts of abnormal liver biochemistry after liver transplantation
Objective: After liver transplant (LT), many investigations are needed to evaluate abnormal liver function test (LFT), which has poor specificity for graft function and complication. A single center retrospective audit of all adult single organ LT from 1/1/2015 to 31/12/2017 was performed. Demographic, clinical and investigation data from the LT database and electronic medical records and cost data from the hospital’s Business Intelligence Unit were analyzed. Patients were classified into uncomplicated or complicated LFT by 2 independent investigators and the number, type, and cost of investigations in the first 30 post-operative days were analyzed. Investigations prior to liver biopsy was sub-analyzed. Results: There was 170 LT with 87 cases of uncomplicated LFT (51.2%) and 83 cases of complicated LFT (48.8%). Most patients with complicated LFT had additional investigations (97.6%), most commonly cholangiogram (55.4%) and liver biopsy (LBx) (50.6%). The additional investigations cost was $1863.3 (95% CI 1289.0–2437.6). Although most LBx (73.8%) showed evidence of rejection, LBx was often not the initial investigation of choice. Current LFT based post-transplant monitoring is inefficient. It remains difficult to determine which patient will benefit from an early invasive procedure like LBx, using LFT alone without further imaging investigations.
- 23 August 2021
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 14 (8) , 799-803
Development of a machine learning-based real-time location system to streamline acute endovascular intervention in acute stroke: a proof-of-concept study
Background Delivery of acute stroke endovascular intervention can be challenging because it requires complex coordination of patient and staff across many different locations. In this proof-of-concept paper we (a) examine whether WiFi fingerprinting is a feasible machine learning (ML)-based real-time location system (RTLS) technology that can provide accurate real-time location information within a hospital setting, and (b) hypothesize its potential application in streamlining acute stroke endovascular intervention. Methods We conducted our study in a comprehensive stroke care unit in Melbourne, Australia that offers a 24-hour mechanical thrombectomy service. ML algorithms including K-nearest neighbors, decision tree, random forest, support vector machine and ensemble models were trained and tested on a public WiFi dataset and the study hospital WiFi dataset. The hospital dataset was collected using the WiFi explorer software (version 3.0.2) on a MacBook Pro (AirPort Extreme, Broadcom BCM43x×1.0). Data analysis was implemented in the Python programming environment using the scikit-learn package. The primary statistical measure for algorithm performance was the accuracy of location prediction. Results ML-based WiFi fingerprinting can accurately predict the different hospital zones relevant in the acute endovascular intervention workflow such as emergency department, CT room and angiography suite. The most accurate algorithms were random forest and support vector machine, both of which were 98% accurate. The algorithms remain robust when new data points, which were distinct from the training dataset, were tested. Conclusions ML-based RTLS technology using WiFi fingerprinting has the potential to streamline delivery of acute stroke endovascular intervention by efficiently tracking patient and staff movement during stroke calls.
- 23 August 2021
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 14 (8) , 799-803
Development of a machine learning-based real-time location system to streamline acute endovascular intervention in acute stroke: a proof-of-concept study
Background Delivery of acute stroke endovascular intervention can be challenging because it requires complex coordination of patient and staff across many different locations. In this proof-of-concept paper we (a) examine whether WiFi fingerprinting is a feasible machine learning (ML)-based real-time location system (RTLS) technology that can provide accurate real-time location information within a hospital setting, and (b) hypothesize its potential application in streamlining acute stroke endovascular intervention. Methods We conducted our study in a comprehensive stroke care unit in Melbourne, Australia that offers a 24-hour mechanical thrombectomy service. ML algorithms including K-nearest neighbors, decision tree, random forest, support vector machine and ensemble models were trained and tested on a public WiFi dataset and the study hospital WiFi dataset. The hospital dataset was collected using the WiFi explorer software (version 3.0.2) on a MacBook Pro (AirPort Extreme, Broadcom BCM43x×1.0). Data analysis was implemented in the Python programming environment using the scikit-learn package. The primary statistical measure for algorithm performance was the accuracy of location prediction. Results ML-based WiFi fingerprinting can accurately predict the different hospital zones relevant in the acute endovascular intervention workflow such as emergency department, CT room and angiography suite. The most accurate algorithms were random forest and support vector machine, both of which were 98% accurate. The algorithms remain robust when new data points, which were distinct from the training dataset, were tested. Conclusions ML-based RTLS technology using WiFi fingerprinting has the potential to streamline delivery of acute stroke endovascular intervention by efficiently tracking patient and staff movement during stroke calls.
- Open Access
- 15 July 2021
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 14 (1) , 3-5
The smart angiography suite
To meet the growing demand for interventional radiology (IR), more hospitals are investing in state-of-the-art angiography suites, but these are expensive investments. Both the initial construction cost and the ongoing operational costs are significant. For health services, it is important to commission an angiography suite that can satisfy both present and future healthcare demands to maximize the value of the initial expenditure and the opportunities provided by this ongoing investment. Smart angiography suites (SAS) could be the solution that future-proof angiography services. Similar to the smart operating theatre, SAS refers to the incorporation of audio-video technology and internet connectivity into the angiography suite.1 SAS has the ability to record high resolution audio-visual data from the angiography suite and stream it to a remote audience at low latency to enable bi-directional communication and collaboration. SAS, alongside other telemedicine concepts, have also gained new-found interest and relevance in light of the global coronavirus pandemic and the travel restrictions associated with this. We reviewed the current literature to provide an overview of the SAS, its potential, and associated legal and ethical considerations.
- 15 July 2021
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 14 (1) , 3-5
Open AccessThe smart angiography suite
To meet the growing demand for interventional radiology (IR), more hospitals are investing in state-of-the-art angiography suites, but these are expensive investments. Both the initial construction cost and the ongoing operational costs are significant. For health services, it is important to commission an angiography suite that can satisfy both present and future healthcare demands to maximize the value of the initial expenditure and the opportunities provided by this ongoing investment. Smart angiography suites (SAS) could be the solution that future-proof angiography services. Similar to the smart operating theatre, SAS refers to the incorporation of audio-video technology and internet connectivity into the angiography suite.1 SAS has the ability to record high resolution audio-visual data from the angiography suite and stream it to a remote audience at low latency to enable bi-directional communication and collaboration. SAS, alongside other telemedicine concepts, have also gained new-found interest and relevance in light of the global coronavirus pandemic and the travel restrictions associated with this. We reviewed the current literature to provide an overview of the SAS, its potential, and associated legal and ethical considerations.