Enric Lujan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Enric Lujan has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Antonio Hinojo
Electrochemical Methods Laboratory—Analytical and Applied Chemistry Department, IQS School of Engineering, Universitat Ramon Llull, Via Augusta 390, 08017 Barcelona, Spain
13 shared publications - Jordi Abella
IQS School of Engineering Universitat Ramon Llull
12 shared publications Sergi Colominas
8 shared publications- Sergi Colominas
Electrochemical Methods Laboratory—Analytical and Applied Chemistry Department, IQS School of Engineering, Universitat Ramon Llull, Via Augusta 390, 08017 Barcelona, Spain
7 shared publications - Ariadna Verdaguer
Institut Químic de Sarrià, Universitat Ramon Llull
4 shared publications - Marc Nel-Lo
IQS School of Engineering Universitat Ramon Llull
4 shared publications
Latest Publications
- Open Access
- 5 September 2026
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 469
Solid-state electrochemical sensor for hydrogen isotopes. Part I: Modulating isotopic detection through surface engineering with graphene
- 5 September 2026
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 469
Open AccessSolid-state electrochemical sensor for hydrogen isotopes. Part I: Modulating isotopic detection through surface engineering with graphene
- Open Access
- 22 August 2026
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 468
Solid-state electrochemical sensor for hydrogen isotopes. Part II: Dual-mode simultaneous quantification of H2 and D2 in gas mixtures
- 22 August 2026
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 468
Open AccessSolid-state electrochemical sensor for hydrogen isotopes. Part II: Dual-mode simultaneous quantification of H2 and D2 in gas mixtures
- Open Access
- 1 June 2026
- Published by Elsevier in SSRN Electronic Journal
Solid-State Electrochemical sensor for Hydrogen Isotopes. Part II: Dual-Mode Simultaneous Quantification of H2 and D2 in Gas Mixtures
Achieving effective fusion energy generation on Earth necessitates precise quantification of deuterium and tritium fuel. This is critical in various stages of the reaction process in Tokamak-type reactors, such as ITER or EU-DEMO. Accurate, rapid, and reliable measurement of tritium in the Tritium Extraction System (TES) and determining the proportions of deuterium and tritium in the fuel cycle system are particularly important. However, due to the significant similarities between these isotopes, current measurement tools reported in bibliography face challenges in distinguishing them when mixed. Electrochemical sensors based on proton-conducting materials exhibit high sensitivity and can operate at temperatures up to 1000°C. These materials have shown proton, deuteron, and triton conductivity, making them suitable for hydrogen quantification under the conditions of the TES and fuel cycle systems.,In the present work, it is proposed a combined potentiometric and amperometric sensor to be able to quantify hydrogen and deuterium simultaneously from a mixture of both. The device was tested at 500°C in mixed hydrogen and deuterium atmospheres, demonstrating the feasibility of simultaneous isotope quantification.
- 1 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSolid-State Electrochemical sensor for Hydrogen Isotopes. Part II: Dual-Mode Simultaneous Quantification of H2 and D2 in Gas Mixtures
Achieving effective fusion energy generation on Earth necessitates precise quantification of deuterium and tritium fuel. This is critical in various stages of the reaction process in Tokamak-type reactors, such as ITER or EU-DEMO. Accurate, rapid, and reliable measurement of tritium in the Tritium Extraction System (TES) and determining the proportions of deuterium and tritium in the fuel cycle system are particularly important. However, due to the significant similarities between these isotopes, current measurement tools reported in bibliography face challenges in distinguishing them when mixed. Electrochemical sensors based on proton-conducting materials exhibit high sensitivity and can operate at temperatures up to 1000°C. These materials have shown proton, deuteron, and triton conductivity, making them suitable for hydrogen quantification under the conditions of the TES and fuel cycle systems.,In the present work, it is proposed a combined potentiometric and amperometric sensor to be able to quantify hydrogen and deuterium simultaneously from a mixture of both. The device was tested at 500°C in mixed hydrogen and deuterium atmospheres, demonstrating the feasibility of simultaneous isotope quantification.
- Open Access
- 21 May 2026
- Published by Elsevier in SSRN Electronic Journal
Solid-State Electrochemical sensor for Hydrogen Isotopes. Part I: Modulating Isotopic detection through Surface Engineering with Graphene
Hydrogen and its isotopes are presented as an interesting alternative to fossil fuels because it is intended to use these species in the field of nuclear fusion, and in fields such as fuel cell technology, among others. To this end, the availability of sensors that can measure these isotopes in-situ and online is a key point for the correct development of these technologies. Electrochemical sensors based on solid-state electrolytes have been proved to be able to operate at elevated temperatures, with great physical and chemical stabilities. In this work, electrochemical sensors were constructed and tested using BaCe0.6Zr0.3Y0.1O3-α electrolytes. To achieve different isotopic responses, a graphene layer was transferred onto the surface of the working electrode. The sensors (with and without graphene) were used in a potentiometric and amperometric configuration at 500 °C. Analyte concentrations in the working electrode ranged from 0.12 to 1 mbar of H2 or D2 in Ar. The presence of graphene produced different sensor responses depending on the isotope. In addition, differences in response and recovery times were also observed, being both higher for the sensors with graphene.
- 21 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSolid-State Electrochemical sensor for Hydrogen Isotopes. Part I: Modulating Isotopic detection through Surface Engineering with Graphene
Hydrogen and its isotopes are presented as an interesting alternative to fossil fuels because it is intended to use these species in the field of nuclear fusion, and in fields such as fuel cell technology, among others. To this end, the availability of sensors that can measure these isotopes in-situ and online is a key point for the correct development of these technologies. Electrochemical sensors based on solid-state electrolytes have been proved to be able to operate at elevated temperatures, with great physical and chemical stabilities. In this work, electrochemical sensors were constructed and tested using BaCe0.6Zr0.3Y0.1O3-α electrolytes. To achieve different isotopic responses, a graphene layer was transferred onto the surface of the working electrode. The sensors (with and without graphene) were used in a potentiometric and amperometric configuration at 500 °C. Analyte concentrations in the working electrode ranged from 0.12 to 1 mbar of H2 or D2 in Ar. The presence of graphene produced different sensor responses depending on the isotope. In addition, differences in response and recovery times were also observed, being both higher for the sensors with graphene.
- Open Access
- 24 April 2024
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 39
A novel solution for hydrogen monitoring in fusion processes: 3D printed BaCe0.6Zr0.3Y0.1O3-α sensors
- 24 April 2024
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 39
Open AccessA novel solution for hydrogen monitoring in fusion processes: 3D printed BaCe0.6Zr0.3Y0.1O3-α sensors
- 16 February 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 59, 1471-1479
Hydrogen and deuterium influence on BaCe0.6Zr0.3Y0.1O3-α electrolyte: Effects on ionic conductivity and on sensing performance
- 16 February 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 59, 1471-1479
Hydrogen and deuterium influence on BaCe0.6Zr0.3Y0.1O3-α electrolyte: Effects on ionic conductivity and on sensing performance
- Open Access
- 11 January 2024
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 38
Garnet-type lithium sensors for the monitoring and control of Pb-Li alloys in tritium breeding modules
- 11 January 2024
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 38
Open AccessGarnet-type lithium sensors for the monitoring and control of Pb-Li alloys in tritium breeding modules
- Open Access
Potentiometric Hydrogen Sensor with 3D-Printed BaCe0.6Zr0.3Y0.1O3-α Electrolyte for High-Temperature Applications
Hydrogen is expected to play an important role in the near future in the transition to a net-zero economy. Therefore, the development of new in situ and real-time analytical tools able to quantify hydrogen at high temperatures is required for future applications. Potentiometric sensors based on perovskite-structured solid-state electrolytes can be a good option for H2 monitoring. Nevertheless, the geometry of the sensor should be designed according to the specific necessities of each technological field. Conventional shaping processes need several iterations of green shaping and machining to achieve a good result. In contrast, 3D printing methods stand out from conventional ones since they simplify the creation of prototypes, reducing the cost and the number of iterations needed for the obtainment of the final design. In the present work, BaCe0.6Zr0.3Y0.1O3-α (BCZY) was used as a proton-conducting electrolyte for potentiometric sensors construction. Two different shapes were tested for the sensors’ electrolyte: pellets (BCZY-Pellet) and crucibles (BCZY-Crucible). Ceramics were shaped using extrusion-based 3D printing. Finally, parameters, such as sensitivity, response time, recovery time and the limit of detection and accuracy, were evaluated for both types of sensors (BCZY-Pellet and BCZY-Crucible) at 500 °C.
Open AccessPotentiometric Hydrogen Sensor with 3D-Printed BaCe0.6Zr0.3Y0.1O3-α Electrolyte for High-Temperature Applications
Hydrogen is expected to play an important role in the near future in the transition to a net-zero economy. Therefore, the development of new in situ and real-time analytical tools able to quantify hydrogen at high temperatures is required for future applications. Potentiometric sensors based on perovskite-structured solid-state electrolytes can be a good option for H2 monitoring. Nevertheless, the geometry of the sensor should be designed according to the specific necessities of each technological field. Conventional shaping processes need several iterations of green shaping and machining to achieve a good result. In contrast, 3D printing methods stand out from conventional ones since they simplify the creation of prototypes, reducing the cost and the number of iterations needed for the obtainment of the final design. In the present work, BaCe0.6Zr0.3Y0.1O3-α (BCZY) was used as a proton-conducting electrolyte for potentiometric sensors construction. Two different shapes were tested for the sensors’ electrolyte: pellets (BCZY-Pellet) and crucibles (BCZY-Crucible). Ceramics were shaped using extrusion-based 3D printing. Finally, parameters, such as sensitivity, response time, recovery time and the limit of detection and accuracy, were evaluated for both types of sensors (BCZY-Pellet and BCZY-Crucible) at 500 °C.
- Open Access
- 26 October 2022
- Published by American Society for Microbiology in Microbiology Spectrum
- Vol. 10 (5) , e0236522
In Vitro and In Vivo Antimicrobial Activity of Hypochlorous Acid against Drug-Resistant and Biofilm-Producing Strains
Currently, drug-resistant infections are increasing and there are fewer antibiotics available to treat them. Therefore, there is an urgent need to find new antibiotics and nonantimicrobial strategies to treat these infections. We present a new nonantibiotic strategy based on hypochlorous acid generation to treat long-term catheter-related and chronic wounds infections.
- 26 October 2022
- Published by American Society for Microbiology in Microbiology Spectrum
- Vol. 10 (5) , e0236522
Open AccessIn Vitro and In Vivo Antimicrobial Activity of Hypochlorous Acid against Drug-Resistant and Biofilm-Producing Strains
Currently, drug-resistant infections are increasing and there are fewer antibiotics available to treat them. Therefore, there is an urgent need to find new antibiotics and nonantimicrobial strategies to treat these infections. We present a new nonantibiotic strategy based on hypochlorous acid generation to treat long-term catheter-related and chronic wounds infections.
- 9 October 2022
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2022-02 (61) , 2262
Li6BaLa2Ta2O12 solid State Probe for Molten Alloys
Nowadays, most of the energy consumption depends on carbon-based sources such as petroleum, natural gas and coal. If the current trend of CO2 emissions continues, the increment in the global average temperature will exceed 2oC (by 2050). Therefore, there is a need to develop new energy sources to reduce the environmental footprint. In this frame, nuclear fusion appears as a carbon-free alternative that perfectly fits in this sustainable transition. Future fusion reactors are expected to use deuterium and tritium as fuel. On the one hand, deuterium is a stable isotope that can be obtained from water. On the other hand, tritium is a radioactive isotope with a relatively short half-life (12.3 years) and must be generated in the reactor itself. For this purpose, it is suggested that lithium will react with high energy neutrons to produce this hydrogen isotope. 6Li + n → 4He + 3H + 4.8MeV This nuclear reaction will take place in the tritium breeding modules. Molten Pb-Li alloy, in its eutectic composition, is considered the main breeding candidate. According to reaction (1), lithium will be consumed. Therefore, to maintain the eutectic composition, it is crucial to control both the concentration and the dosage of lithium. As future nuclear reactors will deal with extreme operational conditions, sensors based on solid-state electrolytes are a promising tool to monitor this lithium content. In the present work, potentiometric sensors to measure Li concentration in molten Sn-Li alloys were constructed. These alloys will be used as a first step before Pb-Li assays. For that, Li6BaLa2Ta2O12 (LBLTO) solid-state electrolyte was synthesized and sintered as a pellet. EIS measurements were performed to evaluate the ionic conductivity of the sintered pellets at temperatures from 30 to 300ºC. These pellets were sealed in alumina tubes using a glass binder for sensor construction. On the one hand, Sn-Li alloys with different lithium contents (from 3at%Li up to 10at%Li) were used in the working electrode. On the other hand, a 3at%Li Sn-Li alloy was considered as the reference electrode. Potentiometric measurements were performed at different temperatures. Correlation curves of the recorded potentials versus the Li activity were in good agreement with the Nernst equation.
- 9 October 2022
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2022-02 (61) , 2262
Li6BaLa2Ta2O12 solid State Probe for Molten Alloys
Nowadays, most of the energy consumption depends on carbon-based sources such as petroleum, natural gas and coal. If the current trend of CO2 emissions continues, the increment in the global average temperature will exceed 2oC (by 2050). Therefore, there is a need to develop new energy sources to reduce the environmental footprint. In this frame, nuclear fusion appears as a carbon-free alternative that perfectly fits in this sustainable transition. Future fusion reactors are expected to use deuterium and tritium as fuel. On the one hand, deuterium is a stable isotope that can be obtained from water. On the other hand, tritium is a radioactive isotope with a relatively short half-life (12.3 years) and must be generated in the reactor itself. For this purpose, it is suggested that lithium will react with high energy neutrons to produce this hydrogen isotope. 6Li + n → 4He + 3H + 4.8MeV This nuclear reaction will take place in the tritium breeding modules. Molten Pb-Li alloy, in its eutectic composition, is considered the main breeding candidate. According to reaction (1), lithium will be consumed. Therefore, to maintain the eutectic composition, it is crucial to control both the concentration and the dosage of lithium. As future nuclear reactors will deal with extreme operational conditions, sensors based on solid-state electrolytes are a promising tool to monitor this lithium content. In the present work, potentiometric sensors to measure Li concentration in molten Sn-Li alloys were constructed. These alloys will be used as a first step before Pb-Li assays. For that, Li6BaLa2Ta2O12 (LBLTO) solid-state electrolyte was synthesized and sintered as a pellet. EIS measurements were performed to evaluate the ionic conductivity of the sintered pellets at temperatures from 30 to 300ºC. These pellets were sealed in alumina tubes using a glass binder for sensor construction. On the one hand, Sn-Li alloys with different lithium contents (from 3at%Li up to 10at%Li) were used in the working electrode. On the other hand, a 3at%Li Sn-Li alloy was considered as the reference electrode. Potentiometric measurements were performed at different temperatures. Correlation curves of the recorded potentials versus the Li activity were in good agreement with the Nernst equation.