SDShavkat Dusmukhamedov

Shavkat Dusmukhamedov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shavkat Dusmukhamedov has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Reliability of a Trapezium Miniplate with Endoscope-Assisted Internal Fixation in Mandibular Subcondylar Fractures: A Three-Dimensional Analysis

    by Seungwook Jung, Ok Hyung Nam, Yi-Qin Fang, Shavkat Dusmukhamedov, Chunui Lee

    This study aimed to evaluate the reliability of a trapezium plate for open reduction and internal fixation (ORIF) of mandibular subcondylar fractures with the simultaneous use of an endoscope. We selected and retrospectively studied 18 patients (12 males and 6 females) with unilateral mandibular subcondylar fractures who visited the Wonju Severance Christian Hospital. The mean age of the patients was 43.43 ± 15.76 years. Patients underwent ORIF with trapezium miniplate application through an intraoral incision under general anesthesia. The clinical and radiographic findings of the fractured side were compared with those of the non-operated side at 6 months follow-up. All occlusions became stable, and transient functional disturbances disappeared within 6 months of periodic follow-up. Functional mandibular movement recovered within the normal range, with an average mouth opening of 41.5 mm, protrusion of 7.5 mm, and lateral excursion of 7 mm at 6 months. Radiographic controls and statistical analysis confirmed a decent anatomical reduction in all 18 cases. In conclusion, the use of a trapezium miniplate with endoscope-assisted ORIF in mandibular subcondylar fractures can be useful for fixation and functional recovery.


  • Open Access

    Digital Denture Fabrication: A Technical Note

    by Shavkat Dusmukhamedov, Chu-Nui Lee, Seung-Mi Jeong, Byung-Ho Choi

    Fabricating a complete denture in a conventional manner may be complicated and difficult. The purpose of this article was to describe the benefits of a fully digital workflow and fabrication procedure of complete dentures based on digital impressions of edentulous jaws. The digital data for the workflow were acquired using an intraoral scanner and were then used to design the denture base and teeth. The resulting data were exported to a 3D printer or a milling machine for denture fabrication.


  • Open Access

    Accuracy of the Provisional Prosthesis Scanning Techniqueversus a Conventional Impression Technique on Completely Edentulous Arches

    by Chunui Lee, Shavkat Dusmukhamedov, Yi-Qin Fang, Seung-Mi Jeong, Byung-Ho Choi

    Purpose: In this study, we aimed to compare the marginal fit of fixed dental restorations fabricated with the provisional prosthesis scanning technique versus a conventional impression technique and to determine the effect of both variables on the accuracy outcome. Materials and Methods: Twelve identical polyurethane edentulous maxillary models were equally divided into two groups: control (conventional impression group) and test (provisional prosthesis scanning group). After obtaining the impression using the above-mentioned methods and further preparing the final prosthesis, the passivity of the metal framework prosthesis was checked using a single screw test, i.e., only one screw was fixed on the terminal right abutment, and all others were empty. The marginal fit of the final prosthetic frameworks screwed onto the implants on the terminal left abutment was measured at the terminal right sight by periapical radiographs obtained immediately after metal framework placements in both groups. The medians derived from the two groups were compared using the Mann–Whitney test. In all tests, a p-value < 0.05 indicated statistical significance. Results: In the provisional prosthesis scanning group, the median marginal fit discrepancy was 170 µm (range 120–190). In the conventional impression group, the median marginal fit discrepancy was 1080 µm (range 1040–1100). There was a significant difference in the implant-framework marginal gap fit discrepancy between these two groups. Conclusion: Prostheses fabricated with the provisional prosthesis scanning technique are significantly more accurate than those fabricated with conventional impression techniques.