Junguang Xiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Junguang Xiang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Haruaki Tanaka
Graduate School of Engineering, The University of Tokyo 1 , Tokyo 113-0032, Japan
1 shared publication- Hiroshi Tanabe
Graduate School of Frontier Sciences, The University of Tokyo
1 shared publication Qinghong Cao
School of Mechanical Engineering, University of Shanghai for Science and Technology 3 , Shanghai 200093, China
1 shared publicationShinjiro Takeda
Graduate School of Engineering, The University of Tokyo 1 , Tokyo 113-0032, Japan
1 shared publication- Yasushi Ono
Graduate School of Frontier Sciences, The University of Tokyo
1 shared publication Yunhan Cai
Graduate School of Engineering, The University of Tokyo 1 , Tokyo 113-0032, Japan
1 shared publication
Latest Publications
- 1 August 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (8) , 083504
Double-filter high-resolution soft x-ray tomographic diagnostic for investigating electron acceleration in TS-6 reconnection merging experiments
An innovative tangential-view soft x-ray (SXR) tomographic imaging measurement was developed on the TS-6 spherical tokamak merging device as a key diagnostic for investigating the mechanism of electron acceleration. In order to measure SXR with different energy ranges, two micro-channel plates (MCPs) are, respectively, installed in two vacuum chambers, which are equipped with different filters. Especially designed lenses and fiber bundles serve as an optical system to transfer images from phosphor plates of MCPs to a high speed imaging system. This design also enables us to simultaneously measure two images appearing on phosphor plates of MCPs by just one high speed imaging system. The temporal and spatial resolution of this diagnostic can be up to 5 µs and 4 mm, respectively, at present. The tomographic method based on the Phillips–Tikhonov regularization is employed to reconstruct line-integrated images into the local emissivity of SXR, which reflects the spatial distribution of high-energy electrons. Owing to this diagnostic, we successfully measured SXR emitted from the downstream region of magnetic reconnection in TS-6 merging experiments for the first time. The energy range of SXR turned out to be higher than 100 eV but lower than 400 eV.
- 1 August 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (8) , 083504
Double-filter high-resolution soft x-ray tomographic diagnostic for investigating electron acceleration in TS-6 reconnection merging experiments
An innovative tangential-view soft x-ray (SXR) tomographic imaging measurement was developed on the TS-6 spherical tokamak merging device as a key diagnostic for investigating the mechanism of electron acceleration. In order to measure SXR with different energy ranges, two micro-channel plates (MCPs) are, respectively, installed in two vacuum chambers, which are equipped with different filters. Especially designed lenses and fiber bundles serve as an optical system to transfer images from phosphor plates of MCPs to a high speed imaging system. This design also enables us to simultaneously measure two images appearing on phosphor plates of MCPs by just one high speed imaging system. The temporal and spatial resolution of this diagnostic can be up to 5 µs and 4 mm, respectively, at present. The tomographic method based on the Phillips–Tikhonov regularization is employed to reconstruct line-integrated images into the local emissivity of SXR, which reflects the spatial distribution of high-energy electrons. Owing to this diagnostic, we successfully measured SXR emitted from the downstream region of magnetic reconnection in TS-6 merging experiments for the first time. The energy range of SXR turned out to be higher than 100 eV but lower than 400 eV.