Ane Håkansson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ane Håkansson has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Lorenzo Senis
Uppsala University, Department of Physics and Astronomy, Uppsala, Sweden
6 shared publications - Peter Andersson
Department of Physics and Astronomy, Division of Applied Nuclear Physics, Uppsala University, Uppsala, Sweden
6 shared publications - Vikram Rathore
Applied Nuclear Physics, Department of Physics and Astronomy, Uppsala University, Uppsala, Sweden
6 shared publications - Peter Jansson
Uppsala University, Department of Radiation Sciences, Uppsala, Sweden
3 shared publications Erik Andersson Sundén
Uppsala University, Department of Physics and Astronomy, Uppsala, Sweden
2 shared publications- Anastasios Anastasiadis
Department of Physics and Astronomy, Uppsala University, SE-751 05 Uppsala, Sweden
1 shared publication
Latest Publications
- Open Access
- 5 January 2024
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 418
ANItA – A new Swedish national competence centre in new nuclear power technology
- 5 January 2024
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 418
Open AccessANItA – A new Swedish national competence centre in new nuclear power technology
- Open Access
- 19 September 2023
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1057
Multi-parameter optimization of gamma emission tomography instruments for irradiated nuclear fuel examination
- 19 September 2023
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1057
Open AccessMulti-parameter optimization of gamma emission tomography instruments for irradiated nuclear fuel examination
- Open Access
- 28 August 2023
- Published by Taylor & Francis in Nuclear Technology
- Vol. 210 (3) , 532-541
First Experimental Demonstration of the Use of a Novel Planar Segmented HPGe Detector for Gamma Emission Tomography of Mockup Fuel Rods
- 28 August 2023
- Published by Taylor & Francis in Nuclear Technology
- Vol. 210 (3) , 532-541
Open AccessFirst Experimental Demonstration of the Use of a Novel Planar Segmented HPGe Detector for Gamma Emission Tomography of Mockup Fuel Rods
- Open Access
- 23 January 2023
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1049
Experimental evaluation of the performance of a novel planar segmented HPGe detector for use in gamma emission tomography
- 23 January 2023
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1049
Open AccessExperimental evaluation of the performance of a novel planar segmented HPGe detector for use in gamma emission tomography
- Open Access
- 16 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (4) , 703-713
A Computational Methodology for Estimating the Detected Energy Spectra of the Gamma-Ray Flux From Irradiated Nuclear Fuel
Gamma-ray spectrometry using collimated detectors is a well-established examination method for irradiated nuclear fuel. However, the feasibility of examining a particular nuclide of interest is subject to constraints; the peak must be statistically determinable with the desired precision, and the total spectrum count rate in the detector should not cause throughput issues. Methods were assembled for gamma spectrum prediction to optimize instruments for gamma emission tomography and to enable a priori feasibility evaluation of determination of single peaks of irradiated nuclear fuel. The aim was to find reliable results (~10% accuracy) regarding total spectrum and peak count rates with faster computation time than a full-Monte Carlo approach. For this purpose, the method is based on depletion calculations with SERPENT2, a point-source kernel method for the collimator response, and a rig response matrix and a detector response matrix, both computed with MCNP6. The computational methodology uses the fuel properties (dimensions, materials, power history, and cooling time) and the instrumental setup (collimator and detector dimensions and materials) as an input. The prediction method was validated using the measured data from a high-burnup, short-cooled test fuel rodlet from the Halden reactor. Absolute count rates and ratios of characteristic peaks were compared between predicted and measured spectra, showing a total count rate overestimation of 7% and discrepancies between 2% and 20% for the single peaks (the same order of magnitude of the uncertainty). This level of agreement is deemed sufficient for measurement campaigns planning and the optimization of spectroscopic instruments for use in gamma scanning and tomography of nuclear fuel.
- 16 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (4) , 703-713
Open AccessA Computational Methodology for Estimating the Detected Energy Spectra of the Gamma-Ray Flux From Irradiated Nuclear Fuel
Gamma-ray spectrometry using collimated detectors is a well-established examination method for irradiated nuclear fuel. However, the feasibility of examining a particular nuclide of interest is subject to constraints; the peak must be statistically determinable with the desired precision, and the total spectrum count rate in the detector should not cause throughput issues. Methods were assembled for gamma spectrum prediction to optimize instruments for gamma emission tomography and to enable a priori feasibility evaluation of determination of single peaks of irradiated nuclear fuel. The aim was to find reliable results (~10% accuracy) regarding total spectrum and peak count rates with faster computation time than a full-Monte Carlo approach. For this purpose, the method is based on depletion calculations with SERPENT2, a point-source kernel method for the collimator response, and a rig response matrix and a detector response matrix, both computed with MCNP6. The computational methodology uses the fuel properties (dimensions, materials, power history, and cooling time) and the instrumental setup (collimator and detector dimensions and materials) as an input. The prediction method was validated using the measured data from a high-burnup, short-cooled test fuel rodlet from the Halden reactor. Absolute count rates and ratios of characteristic peaks were compared between predicted and measured spectra, showing a total count rate overestimation of 7% and discrepancies between 2% and 20% for the single peaks (the same order of magnitude of the uncertainty). This level of agreement is deemed sufficient for measurement campaigns planning and the optimization of spectroscopic instruments for use in gamma scanning and tomography of nuclear fuel.
- Open Access
- 15 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (4) , 714-721
Calculation of Spatial Response of a Collimated Segmented HPGe Detector for Gamma Emission Tomography by MCNP Simulations
We have proposed a planar electronically segmented high-purity germanium (HPGe) detector concept in combination with a multislit collimator for gamma emission tomography. In this work, the spatial resolution achievable using the collimated segmented HPGe detector was evaluated, prior to the manufacture and operation of the detector. The spatial response of a collimated segmented HPGe detector concept was evaluated using simulations performed with Monte Carlo N-Particle (MCNP) transport code MCNP6. The full detector and multislit collimator system were modeled, and for the quantification of the spatial response, the modulation transfer function (MTF) was chosen as a performance metric. The MTF curve was obtained through the calculation of the line spread function (LSF) by analyzing the simulated projection data. In addition, tomographic reconstructions of the simulated simplified test objects were made to demonstrate the performance of the segmented HPGe detector in planned application. For 662-keV photons, the spatial resolution obtained was approximately the same as the collimator slit width for both the 100- and 150-mm-long collimators. The corresponding spatial resolution at 1596-keV photon energy was almost twice the slit width for the 100-mm collimator, due to the partial penetration of the high-energy gamma rays through the collimator bulk. For a 150-mm-long collimator, an improved resolution was obtained.
- 15 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (4) , 714-721
Open AccessCalculation of Spatial Response of a Collimated Segmented HPGe Detector for Gamma Emission Tomography by MCNP Simulations
We have proposed a planar electronically segmented high-purity germanium (HPGe) detector concept in combination with a multislit collimator for gamma emission tomography. In this work, the spatial resolution achievable using the collimated segmented HPGe detector was evaluated, prior to the manufacture and operation of the detector. The spatial response of a collimated segmented HPGe detector concept was evaluated using simulations performed with Monte Carlo N-Particle (MCNP) transport code MCNP6. The full detector and multislit collimator system were modeled, and for the quantification of the spatial response, the modulation transfer function (MTF) was chosen as a performance metric. The MTF curve was obtained through the calculation of the line spread function (LSF) by analyzing the simulated projection data. In addition, tomographic reconstructions of the simulated simplified test objects were made to demonstrate the performance of the segmented HPGe detector in planned application. For 662-keV photons, the spatial resolution obtained was approximately the same as the collimator slit width for both the 100- and 150-mm-long collimators. The corresponding spatial resolution at 1596-keV photon energy was almost twice the slit width for the 100-mm collimator, due to the partial penetration of the high-energy gamma rays through the collimator bulk. For a 150-mm-long collimator, an improved resolution was obtained.
- Open Access
- 1 October 2021
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1014
Evaluation of gamma-ray transmission through rectangular collimator slits for application in nuclear fuel spectrometry
- 1 October 2021
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1014
Open AccessEvaluation of gamma-ray transmission through rectangular collimator slits for application in nuclear fuel spectrometry