Taku Goto
Research Subjects
Taku Goto has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Kazuo Terashima
Department of Advanced Materials Science, Graduate School of Frontier Sciences, The University of Tokyo
5 shared publications - Tsuyohito Ito
Department of Advanced Materials Science, Graduate School of Frontier Sciences, The University of Tokyo
5 shared publications - Yukiya Hakuta
Advanced Operando-Measurement Technology Open Innovation Laboratory, National Institute of Advanced Industrial Science and Technology (AIST), 5-1-5 Kashiwanoha, Chiba, 277-8589, JAPAN
5 shared publications Jun Akedo
4 shared publicationsKohzo Ito
Univ Tokyo, Grad Sch Frontier Sci, Dept Adv Mat Sci, 5 1 5 Kashiwanoha, Kashiwa, Chiba 2778561, Japan
4 shared publications- Yoshiki Shimizu
Research Institute of Core Technology for Materials Innovation National Institute of Advanced Industrial Science and Technology (AIST) Tsukuba Japan
4 shared publications
Latest Publications
- 16 July 2026
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 42 (29) , 21502-21509
Polymer Brush-Assisted Reduction of Contact Thermal Resistance via Interfacial Diffusion of a Liquid Polymer
In this study, we propose a thermal contact strategy to significantly reduce contact thermal resistance by introducing polydimethylsiloxane (PDMS) polymer brushes at the interface between Si substrates. When PDMS oil is sandwiched between the PDMS-brush-modified Si substrates, the contact thermal resistance is reduced by approximately a factor of 5 compared with unmodified Si substrates, achieving values comparable to or lower than those of commercial thermal greases. The time evolution of thermal resistance as a function of molecular weight and temperature suggests that this reduction is consistent with interfacial structural changes associated with the diffusion of PDMS oil into the polymer brush layer. This approach provides a promising route for increasing interfacial thermal transport.
- 16 July 2026
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 42 (29) , 21502-21509
Polymer Brush-Assisted Reduction of Contact Thermal Resistance via Interfacial Diffusion of a Liquid Polymer
In this study, we propose a thermal contact strategy to significantly reduce contact thermal resistance by introducing polydimethylsiloxane (PDMS) polymer brushes at the interface between Si substrates. When PDMS oil is sandwiched between the PDMS-brush-modified Si substrates, the contact thermal resistance is reduced by approximately a factor of 5 compared with unmodified Si substrates, achieving values comparable to or lower than those of commercial thermal greases. The time evolution of thermal resistance as a function of molecular weight and temperature suggests that this reduction is consistent with interfacial structural changes associated with the diffusion of PDMS oil into the polymer brush layer. This approach provides a promising route for increasing interfacial thermal transport.
- Open Access
- 10 February 2025
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 35, 3803-3810
Quasi-elastic liquid metal thermal interface material with varying surface wettability for heat dissipation from vibrating and deforming heat sources
- 10 February 2025
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 35, 3803-3810
Open AccessQuasi-elastic liquid metal thermal interface material with varying surface wettability for heat dissipation from vibrating and deforming heat sources
- Open Access
- 10 April 2024
- Published by Elsevier in Materials Letters: X
- Vol. 22
Composites with aligned and plasma-surface-modified graphene nanoplatelets and high dielectric constants
- 10 April 2024
- Published by Elsevier in Materials Letters: X
- Vol. 22
Open AccessComposites with aligned and plasma-surface-modified graphene nanoplatelets and high dielectric constants
- 22 February 2024
- Published by Elsevier in Ceramics International
- Vol. 50 (10) , 17940-17949
Thermal conductivity of nanocrystalline alumina films fabricated by aerosol deposition
- 22 February 2024
- Published by Elsevier in Ceramics International
- Vol. 50 (10) , 17940-17949
Thermal conductivity of nanocrystalline alumina films fabricated by aerosol deposition
- 18 October 2023
- Published by Elsevier in Ceramics International
- Vol. 50 (1) , 892-896
Ceramic coating on rubber by aerosol deposition with cryogenic substrate cooling
- 18 October 2023
- Published by Elsevier in Ceramics International
- Vol. 50 (1) , 892-896
Ceramic coating on rubber by aerosol deposition with cryogenic substrate cooling
- Open Access
- 9 August 2022
- Published by Springer Nature in Cureus
- Vol. 14 (8) , e27829
Gastrointestinal Perforation Complicated by Continuous Opioids Administration for Intrahepatic Cystic Hemorrhage Pain Management
Intracystic hemorrhage is a rare complication of multiple hepatic cysts and can lead to hemorrhagic shock. Hence, measures should be taken to prevent the rupture of cysts. The incidence of intestinal perforation is high in patients undergoing hemodialysis. The diagnosis can be difficult in a patient without typical symptoms. We report the case of a woman in her late 60s with multiple renal and hepatic cysts, which caused chronic renal failure managed with dialysis. She presented with abdominal pain and was diagnosed with intrahepatic cystic bleeding. Continuous intravenous fentanyl was administered for pain management, which temporarily alleviated pain, but abdominal pain recurred with increased intensity when she resumed feeding. Subsequently, a contrast-enhanced computed tomography revealed perforation of the lower gastrointestinal tract. Therefore, in cases of intrahepatic cystic hemorrhage that require administration of analgesics, the complications of other diseases that may also cause acute abdominal pain should also be considered.
- 9 August 2022
- Published by Springer Nature in Cureus
- Vol. 14 (8) , e27829
Open AccessGastrointestinal Perforation Complicated by Continuous Opioids Administration for Intrahepatic Cystic Hemorrhage Pain Management
Intracystic hemorrhage is a rare complication of multiple hepatic cysts and can lead to hemorrhagic shock. Hence, measures should be taken to prevent the rupture of cysts. The incidence of intestinal perforation is high in patients undergoing hemodialysis. The diagnosis can be difficult in a patient without typical symptoms. We report the case of a woman in her late 60s with multiple renal and hepatic cysts, which caused chronic renal failure managed with dialysis. She presented with abdominal pain and was diagnosed with intrahepatic cystic bleeding. Continuous intravenous fentanyl was administered for pain management, which temporarily alleviated pain, but abdominal pain recurred with increased intensity when she resumed feeding. Subsequently, a contrast-enhanced computed tomography revealed perforation of the lower gastrointestinal tract. Therefore, in cases of intrahepatic cystic hemorrhage that require administration of analgesics, the complications of other diseases that may also cause acute abdominal pain should also be considered.
- 6 June 2022
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 55 (33) , 335204
Chemical-free exfoliation of hexagonal boron nitride via cavitation-bubble plasma in water
Hexagonal boron nitride (h-BN) sheets have numerous applications, but current low-cost, environmentally friendly techniques for h-BN exfoliation yield undesirably small sheet sizes. We have developed a novel chemical-free method to prepare large h-BN nanosheets (BNNSs) by the exfoliation of h-BN using plasma with cavitation bubbles in water, named here as cavitation-bubble plasma. Unlike ordinary liquid exfoliation methods, which reduce the sheet size of BNNSs compared with that of the starting h-BN, the cavitation-bubble plasma process exfoliated h-BN without reducing the sheet size. Furthermore, the plasma dramatically improved the exfoliation yield.
- 6 June 2022
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 55 (33) , 335204
Chemical-free exfoliation of hexagonal boron nitride via cavitation-bubble plasma in water
Hexagonal boron nitride (h-BN) sheets have numerous applications, but current low-cost, environmentally friendly techniques for h-BN exfoliation yield undesirably small sheet sizes. We have developed a novel chemical-free method to prepare large h-BN nanosheets (BNNSs) by the exfoliation of h-BN using plasma with cavitation bubbles in water, named here as cavitation-bubble plasma. Unlike ordinary liquid exfoliation methods, which reduce the sheet size of BNNSs compared with that of the starting h-BN, the cavitation-bubble plasma process exfoliated h-BN without reducing the sheet size. Furthermore, the plasma dramatically improved the exfoliation yield.
- Open Access
- 3 April 2022
- Published by Taylor & Francis in Journal of Asian Ceramic Societies
- Vol. 10 (2) , 465-472
Chlorhexidine-filled porous ceramic coating fabricated by the aerosol deposition method for immediate and long-term enveloped virus inactivation
We developed an antiviral ceramic coating for immediate and long-term enveloped virus inactivation. The coating consisted of a porous ceramic coating fabricated by aerosol deposition and filled with chlorhexidine (CHX). The coating immediately inactivated enveloped viruses by releasing CHX. Furthermore, after the coating was repeatedly washed to simulate practical use, it still showed antiviral activity because CHX leakage was suppressed by the nanopores in the coating. We expect our antiviral coating to exhibit antiviral activity under conditions similar to practical use.
- 3 April 2022
- Published by Taylor & Francis in Journal of Asian Ceramic Societies
- Vol. 10 (2) , 465-472
Open AccessChlorhexidine-filled porous ceramic coating fabricated by the aerosol deposition method for immediate and long-term enveloped virus inactivation
We developed an antiviral ceramic coating for immediate and long-term enveloped virus inactivation. The coating consisted of a porous ceramic coating fabricated by aerosol deposition and filled with chlorhexidine (CHX). The coating immediately inactivated enveloped viruses by releasing CHX. Furthermore, after the coating was repeatedly washed to simulate practical use, it still showed antiviral activity because CHX leakage was suppressed by the nanopores in the coating. We expect our antiviral coating to exhibit antiviral activity under conditions similar to practical use.