Vanessa Pineda-Borja
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Vanessa Pineda-Borja has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Jheferson Contreras-Grande
Departamento de Investigación, Docencia y Apoyo al Diagnóstico por Imágenes, Instituto Nacional de Ciencias Neurológicas. Lima, Perú. / Resocentro. Lima, Perú
3 shared publications - Albert Pons-Escoda
Radiology Department, Hospital Universitari de Bellvitge, L'Hospitalet de Llobregat, Barcelona, Spain; Institut de Diagnòstic Per La Imatge (IDI), L'Hospitalet de Llobregat, Centre Bellvige, Barcelona, Spain; NeuroOncology Unit, Bellvitge Biomedical Research Institute (IDIBELL), L'Hospitalet de Llobregat, Barcelona, Spain
2 shared publications - Carles Majós
Neuro-Oncology Unit, Bellvitge University Hospital-Catalan Institute of Oncology (ICO), Bellvitge Biomedical Research Institute (IDIBELL); L'Hospitalet, Barcelona, Spain
2 shared publications - Ignacio Martínez-Zalacaín
Department of Psychiatry, Bellvitge Biomedical Research Institute, Bellvitge University Hospital, Barcelona, Spain; Department of Radiology, Bellvitge University Hospital, Barcelona, Spain
2 shared publications - Lucía Romero-Pinel
Multiple Sclerosis Unit, Department of Neurology, Hospital Universitari de Bellvitge, L’Hospitalet de Llobregat, Barcelona, Spain
2 shared publications - Mònica Cos
Radiology Department, Hospital Universitari de Bellvitge, L’Hospitalet de Llobregat, Carrer de Feixa Llarga SN, Barcelona, Spain
2 shared publications
Latest Publications
- Open Access
- 31 March 2026
- Published by Universidad Peruana Cayetano Heredia in Revista Médica Herediana
- Vol. 37 (1) , 53-54
Osículos de Oppenheimer
- 31 March 2026
- Published by Universidad Peruana Cayetano Heredia in Revista Médica Herediana
- Vol. 37 (1) , 53-54
Open AccessOsículos de Oppenheimer
- Open Access
- 3 October 2025
- Published by Springer Nature in Insights into Imaging
- Vol. 16 (1) , 1-11
3D T1 turbo spin echo improves detection of gadolinium-enhancing multiple-sclerosis lesions
Objectives: To compare the performance of 3D T1 turbo spin echo (3DT1TSE) and 3D T1 turbo field echo (3DT1TFE) MRI in detecting gadolinium-enhancing lesions in multiple sclerosis (MS). Materials and methods: We retrospectively analyzed 255 3-T MRIs from MS patients, each including post-contrast 3DT1TSE and 3DT1TFE sequences. Two blinded readers independently assessed enhancing lesions per sequence. A consensus review, incorporating longitudinal imaging and additional sequences, served as the reference standard. Results: The consensus identified 70 enhancing lesions in 31 patients. All 70 were visible on 3DT1TSE, while 64 (91%) were detectable on 3DT1TFE. Reader sensitivity was higher for 3DT1TSE (84% and 90%) than 3DT1TFE (45% and 40%) (p < 0.01). Inter-reader agreement was excellent for 3DT1TSE (ICC = 0.90) and moderate for 3DT1TFE (intraclass correlation coefficient = 0.69). Although false positives were more common with 3DT1TSE, they were readily excluded during consensus reading. In six patients, enhancing lesions were detected only on 3DT1TSE, with treatment escalation in two. Conclusion: 3DT1TSE outperformed 3DT1TFE in sensitivity and reader agreement for enhancing lesion detection in MS. Incorporating 3DT1TSE into standard MRI protocols may improve disease activity assessment and clinical decision-making. Critical relevance statement: Replacing 3D gradient-echo with post-contrast 3D T1 turbo spin-echo brain MRI greatly improves the detection of gadolinium-enhancing multiple-sclerosis lesions, boosting diagnostic sensitivity and reader agreement and directly influencing treatment-escalation decisions in routine practice. Key Points: Detecting and enhancing MS lesions is limited by standard 3D T1 turbo field echo (3DT1TFE) MRI. 3D T1 turbo spin echo detects significantly more gadolinium-enhancing MS lesions than conventional 3DT1TFE. Greater lesion detection allows more precise activity assessment and optimal treatment management. Graphical
- 3 October 2025
- Published by Springer Nature in Insights into Imaging
- Vol. 16 (1) , 1-11
Open Access3D T1 turbo spin echo improves detection of gadolinium-enhancing multiple-sclerosis lesions
Objectives: To compare the performance of 3D T1 turbo spin echo (3DT1TSE) and 3D T1 turbo field echo (3DT1TFE) MRI in detecting gadolinium-enhancing lesions in multiple sclerosis (MS). Materials and methods: We retrospectively analyzed 255 3-T MRIs from MS patients, each including post-contrast 3DT1TSE and 3DT1TFE sequences. Two blinded readers independently assessed enhancing lesions per sequence. A consensus review, incorporating longitudinal imaging and additional sequences, served as the reference standard. Results: The consensus identified 70 enhancing lesions in 31 patients. All 70 were visible on 3DT1TSE, while 64 (91%) were detectable on 3DT1TFE. Reader sensitivity was higher for 3DT1TSE (84% and 90%) than 3DT1TFE (45% and 40%) (p < 0.01). Inter-reader agreement was excellent for 3DT1TSE (ICC = 0.90) and moderate for 3DT1TFE (intraclass correlation coefficient = 0.69). Although false positives were more common with 3DT1TSE, they were readily excluded during consensus reading. In six patients, enhancing lesions were detected only on 3DT1TSE, with treatment escalation in two. Conclusion: 3DT1TSE outperformed 3DT1TFE in sensitivity and reader agreement for enhancing lesion detection in MS. Incorporating 3DT1TSE into standard MRI protocols may improve disease activity assessment and clinical decision-making. Critical relevance statement: Replacing 3D gradient-echo with post-contrast 3D T1 turbo spin-echo brain MRI greatly improves the detection of gadolinium-enhancing multiple-sclerosis lesions, boosting diagnostic sensitivity and reader agreement and directly influencing treatment-escalation decisions in routine practice. Key Points: Detecting and enhancing MS lesions is limited by standard 3D T1 turbo field echo (3DT1TFE) MRI. 3D T1 turbo spin echo detects significantly more gadolinium-enhancing MS lesions than conventional 3DT1TFE. Greater lesion detection allows more precise activity assessment and optimal treatment management. Graphical
- Open Access
- 30 June 2025
- Published by Universidad Peruana Cayetano Heredia in Revista Médica Herediana
- Vol. 36 (2) , 168-169
Signo del tridente en síndrome de desmielinización osmótica
- 30 June 2025
- Published by Universidad Peruana Cayetano Heredia in Revista Médica Herediana
- Vol. 36 (2) , 168-169
Open AccessSigno del tridente en síndrome de desmielinización osmótica
- Open Access
Improved detection of multiple sclerosis gadolinium-enhancing lesions: 3D T1 Turbo-Spin-Echo Outperforms 3D T1 Turbo-Field Echo MRI
Objectives To compare the performance of 3D T1 turbo spin echo (3DT1TSE) and 3D T1 turbo field echo (3DT1TFE) MRI in detecting gadolinium-enhancing lesions in multiple sclerosis (MS). Methods We retrospectively analyzed 255 3T MRIs from MS patients, each including post-contrast 3DT1TSE and 3DT1TFE sequences. Two blinded readers independently assessed enhancing lesions per sequence. A consensus review, incorporating longitudinal imaging and additional sequences, served as the reference standard. Results The consensus identified 70 enhancing lesions in 31 patients. All 70 were visible on 3DT1TSE, while 64 (91%) were detectable on 3DT1TFE. Reader sensitivity was higher for 3DT1TSE (84% and 90%) than 3DT1TFE (45% and 40%) (p < 0.01). Inter-reader agreement was excellent for 3DT1TSE (ICC = 0.90) and moderate for 3DT1TFE (ICC = 0.69). Although false positives were more common with 3DT1TSE, they were readily excluded during consensus reading. In six patients, enhancing lesions were detected only on 3DT1TSE, with treatment escalation in two. Conclusion 3DT1TSE outperformed 3DT1TFE in sensitivity and reader agreement for enhancing lesion detection in MS. Incorporating 3DT1TSE into standard MRI protocols may improve disease activity assessment and clinical decision-making.
Open AccessImproved detection of multiple sclerosis gadolinium-enhancing lesions: 3D T1 Turbo-Spin-Echo Outperforms 3D T1 Turbo-Field Echo MRI
Objectives To compare the performance of 3D T1 turbo spin echo (3DT1TSE) and 3D T1 turbo field echo (3DT1TFE) MRI in detecting gadolinium-enhancing lesions in multiple sclerosis (MS). Methods We retrospectively analyzed 255 3T MRIs from MS patients, each including post-contrast 3DT1TSE and 3DT1TFE sequences. Two blinded readers independently assessed enhancing lesions per sequence. A consensus review, incorporating longitudinal imaging and additional sequences, served as the reference standard. Results The consensus identified 70 enhancing lesions in 31 patients. All 70 were visible on 3DT1TSE, while 64 (91%) were detectable on 3DT1TFE. Reader sensitivity was higher for 3DT1TSE (84% and 90%) than 3DT1TFE (45% and 40%) (p < 0.01). Inter-reader agreement was excellent for 3DT1TSE (ICC = 0.90) and moderate for 3DT1TFE (ICC = 0.69). Although false positives were more common with 3DT1TSE, they were readily excluded during consensus reading. In six patients, enhancing lesions were detected only on 3DT1TSE, with treatment escalation in two. Conclusion 3DT1TSE outperformed 3DT1TFE in sensitivity and reader agreement for enhancing lesion detection in MS. Incorporating 3DT1TSE into standard MRI protocols may improve disease activity assessment and clinical decision-making.
- Open Access
- 26 March 2021
- Published by Instituto Nacional de Salud (Peru) in Revista Peruana de Medicina Experimental Y Salud Pública
- Vol. 38 (2) , 206-13
Hallazgos tomográficos pulmonares asociados a severidad y mortalidad en pacientes con la COVID-19
Objetivos: Determinar los hallazgos tomográficos pulmonares asociados a severidad y mortalidad en pacientes con la COVID-19 del Hospital Nacional Edgardo Rebagliati Martins (HNERM), y proponer puntos de corte para una puntuación tomográfica de severidad (PTS). Materiales y métodos: Estudio de cohorte retrospectivo en 254 pacientes con la COVID-19 que contaban con tomografía de tórax clasificado según severidad clínica. Se realizó un análisis multivariado mediante regresión logística para determinar asociación con la severidad clínica, un análisis de regresión de Cox para evaluar mortalidad, y curvas ROC para evaluar la PTS. Resultados: Los hallazgos tomográficos asociados a severidad clínica fueron el patrón difuso de las lesiones (OR: 3,23, IC 95%: 1,46-7,14), patrón en «empedrado» (OR: 2,48; IC 95%: 1,08-5,68) y mayor valor en la PTS (OR: 1,73; IC 95%: 1,49-2,02). Los hallazgos asociados a mortalidad fueron el patrón en «empedrado» (HR: 1,78; IC 95%: 1,03-3,06) y mayor valor en la PTS (HR: 1,33; IC 95%: 1,20-1,48). Un valor de 7 en la PTS tuvo una sensibilidad de 94,4% y especificidad de 100% para identificar casos moderados y un valor de 13 tuvo una sensibilidad de 84,9% y una especificidad de 70,6% para casos severos. Conclusiones: El patrón difuso de las lesiones se asoció a una mayor severidad clínica. El patrón en «empedrado» y un mayor valor en la PTS se asociaron a mayor severidad clínica y a mortalidad. Se proponen los valores de 7 y 13 como puntos de corte de la PTS para identificar casos moderados y severos.
- 26 March 2021
- Published by Instituto Nacional de Salud (Peru) in Revista Peruana de Medicina Experimental Y Salud Pública
- Vol. 38 (2) , 206-13
Open AccessHallazgos tomográficos pulmonares asociados a severidad y mortalidad en pacientes con la COVID-19
Objetivos: Determinar los hallazgos tomográficos pulmonares asociados a severidad y mortalidad en pacientes con la COVID-19 del Hospital Nacional Edgardo Rebagliati Martins (HNERM), y proponer puntos de corte para una puntuación tomográfica de severidad (PTS). Materiales y métodos: Estudio de cohorte retrospectivo en 254 pacientes con la COVID-19 que contaban con tomografía de tórax clasificado según severidad clínica. Se realizó un análisis multivariado mediante regresión logística para determinar asociación con la severidad clínica, un análisis de regresión de Cox para evaluar mortalidad, y curvas ROC para evaluar la PTS. Resultados: Los hallazgos tomográficos asociados a severidad clínica fueron el patrón difuso de las lesiones (OR: 3,23, IC 95%: 1,46-7,14), patrón en «empedrado» (OR: 2,48; IC 95%: 1,08-5,68) y mayor valor en la PTS (OR: 1,73; IC 95%: 1,49-2,02). Los hallazgos asociados a mortalidad fueron el patrón en «empedrado» (HR: 1,78; IC 95%: 1,03-3,06) y mayor valor en la PTS (HR: 1,33; IC 95%: 1,20-1,48). Un valor de 7 en la PTS tuvo una sensibilidad de 94,4% y especificidad de 100% para identificar casos moderados y un valor de 13 tuvo una sensibilidad de 84,9% y una especificidad de 70,6% para casos severos. Conclusiones: El patrón difuso de las lesiones se asoció a una mayor severidad clínica. El patrón en «empedrado» y un mayor valor en la PTS se asociaron a mayor severidad clínica y a mortalidad. Se proponen los valores de 7 y 13 como puntos de corte de la PTS para identificar casos moderados y severos.