Feng Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Feng Zhou has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
C. Adolphsen
SLAC National Accelerator Laboratory, Menlo Park, CA, United States
2 shared publications- Yuantao Ding
SLAC National Accelerator Laboratory, Menlo Park, USA
2 shared publications A. Benwell
SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA
1 shared publicationA. Brachmann
SLAC National Accelerator Laboratory
1 shared publicationA. Kabel
Accelerator Center, Menlo Park, California 94025, USA
1 shared publicationA. Miahnahri
SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA
1 shared publication
Latest Publications
- Open Access
- 15 October 2026
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 29 (10)
Linac Coherent Light Source II injector commissioning and early operational experience
The Linac Coherent Light Source II (LCLS-II) is designed to generate 4 GeV electron bunches at an up-to-1-MHz-high repetition rate to drive x-ray free electron lasers. It has been in user operation since 2023 and has progressively ramped up the beam repetition rate to 93 kHz to date. The LCLS-II 1-MeV electron source was successfully commissioned between 2018 and 2020. The full-scale LCLS-II injector, operating above 75 MeV, began commissioning in 2022 and transitioned to operations a few months later. The LCLS-II injector has demonstrated the ability to deliver a high-brightness, low-emittance electron beam at high repetition rates, meeting key performance targets. However, several operational challenges have emerged during commissioning and early user operations. These include substantial gun dark current, the dependence of bunch charge generation and free-electron laser pulse intensity on the beam repetition rate, the formation of cathode quantum efficiency craters and bumps, significant emittance growth through the laser heater chicane, beam breakup, and the presence of beam halos. This paper presents recent progress in addressing these challenges, along with injector emittance measurements and optimizations, and the first demonstration of operating a laser heater undulator at the third-harmonic resonance.
- 15 October 2026
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 29 (10)
Open AccessLinac Coherent Light Source II injector commissioning and early operational experience
The Linac Coherent Light Source II (LCLS-II) is designed to generate 4 GeV electron bunches at an up-to-1-MHz-high repetition rate to drive x-ray free electron lasers. It has been in user operation since 2023 and has progressively ramped up the beam repetition rate to 93 kHz to date. The LCLS-II 1-MeV electron source was successfully commissioned between 2018 and 2020. The full-scale LCLS-II injector, operating above 75 MeV, began commissioning in 2022 and transitioned to operations a few months later. The LCLS-II injector has demonstrated the ability to deliver a high-brightness, low-emittance electron beam at high repetition rates, meeting key performance targets. However, several operational challenges have emerged during commissioning and early user operations. These include substantial gun dark current, the dependence of bunch charge generation and free-electron laser pulse intensity on the beam repetition rate, the formation of cathode quantum efficiency craters and bumps, significant emittance growth through the laser heater chicane, beam breakup, and the presence of beam halos. This paper presents recent progress in addressing these challenges, along with injector emittance measurements and optimizations, and the first demonstration of operating a laser heater undulator at the third-harmonic resonance.
- Open Access
- 19 April 2023
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 11
Overview of CW electron guns and LCLS-II RF gun performance
Various continuous-wave (CW) electron gun technologies are reviewed, including DC, superconducting radio frequency RF (SRF), hybrid DC-SRF and normal-conducting RF. Also, the SLAC Linac Coherent Light Source II (LCLS-II) normal-conducting RF gun and injector are described, and the performance to date, including the bunch emittance achieved and the dark current observed, is presented.
- 19 April 2023
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 11
Open AccessOverview of CW electron guns and LCLS-II RF gun performance
Various continuous-wave (CW) electron gun technologies are reviewed, including DC, superconducting radio frequency RF (SRF), hybrid DC-SRF and normal-conducting RF. Also, the SLAC Linac Coherent Light Source II (LCLS-II) normal-conducting RF gun and injector are described, and the performance to date, including the bunch emittance achieved and the dark current observed, is presented.
- Open Access
- 23 July 2021
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 24 (7) , 073401
Commissioning of the SLAC Linac Coherent Light Source II electron source
For the Linac Coherent Light Source II (LCLS-II) project at SLAC, a 1.3 GHz superconducting rf (SRF) linac is being constructed that will generate 4 GeV electron bunches at a high repetition rate to drive x-ray free electron lasers. The LCLS-II electron source, which comprises the first three meters of the electron injector, includes two normal-conducting, continuous-wave rf cavities: a one-cell, 185.7 MHz gun and a two-cell, 1.3 GHz buncher. It also includes a gun load-lock system that allows photocathodes to be changed under vacuum. The components in this beam-line section were designed and built by Lawrence Berkeley National Laboratory based on experience from their advanced photoinjector experiment program. In combination with the SLAC UV laser system, the electron source is designed to produce beam rates up to 1 MHz with average currents up to initially. The source was installed in mid-2018, well in advance of the SRF linac, which is now nearing completion. The source was commissioned over a two-year period, and this paper presents results including electron beam and dark current characterization.- 23 July 2021
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 24 (7) , 073401
Open AccessCommissioning of the SLAC Linac Coherent Light Source II electron source
For the Linac Coherent Light Source II (LCLS-II) project at SLAC, a 1.3 GHz superconducting rf (SRF) linac is being constructed that will generate 4 GeV electron bunches at a high repetition rate to drive x-ray free electron lasers. The LCLS-II electron source, which comprises the first three meters of the electron injector, includes two normal-conducting, continuous-wave rf cavities: a one-cell, 185.7 MHz gun and a two-cell, 1.3 GHz buncher. It also includes a gun load-lock system that allows photocathodes to be changed under vacuum. The components in this beam-line section were designed and built by Lawrence Berkeley National Laboratory based on experience from their advanced photoinjector experiment program. In combination with the SLAC UV laser system, the electron source is designed to produce beam rates up to 1 MHz with average currents up to initially. The source was installed in mid-2018, well in advance of the SRF linac, which is now nearing completion. The source was commissioned over a two-year period, and this paper presents results including electron beam and dark current characterization. - 30 July 2015
- Published by Oxford University Press (OUP) in International Journal of Food Science and Technology
- Vol. 50 (11) , 2360-2366
Effects of different carbon sources and C/N values on nonvolatile taste components of Pleurotus eryngii
Summary: Pleurotus eryngii, the second largest industrial cultivation mushroom in China, is usually cultivated on substrates mainly consisting of sawdust and corncob. In this study, experiments were performed to determine the effects of different carbon sources and C/N values on nonvolatile taste components of P. eryngii. The effects of different carbon sources on nonvolatile taste components levels revealed that sawdust was beneficial to high levels of crude protein, amino acids, 5′‐nucleotides and equivalent umami concentration, while corncob was beneficial to high contents of carbohydrate, polysaccharides and trehalose. At the similar C/N values, relatively higher sawdust content was beneficial to umami amino acid production, while relatively higher corncob content was beneficial to high contents of carbohydrate, polysaccharides and mannitol. Higher C/N value was beneficial to high levels of crude protein, amino acids, 5′‐nucleotides and equivalent umami concentration, while lower C/N value was beneficial to high contents of carbohydrate, polysaccharides and trehalose. These results provided information for P. eryngii fruit body industrial cultivation to obtain specific nonvolatile taste components with high levels.
- 30 July 2015
- Published by Oxford University Press (OUP) in International Journal of Food Science and Technology
- Vol. 50 (11) , 2360-2366
Effects of different carbon sources and C/N values on nonvolatile taste components of Pleurotus eryngii
Summary: Pleurotus eryngii, the second largest industrial cultivation mushroom in China, is usually cultivated on substrates mainly consisting of sawdust and corncob. In this study, experiments were performed to determine the effects of different carbon sources and C/N values on nonvolatile taste components of P. eryngii. The effects of different carbon sources on nonvolatile taste components levels revealed that sawdust was beneficial to high levels of crude protein, amino acids, 5′‐nucleotides and equivalent umami concentration, while corncob was beneficial to high contents of carbohydrate, polysaccharides and trehalose. At the similar C/N values, relatively higher sawdust content was beneficial to umami amino acid production, while relatively higher corncob content was beneficial to high contents of carbohydrate, polysaccharides and mannitol. Higher C/N value was beneficial to high levels of crude protein, amino acids, 5′‐nucleotides and equivalent umami concentration, while lower C/N value was beneficial to high contents of carbohydrate, polysaccharides and trehalose. These results provided information for P. eryngii fruit body industrial cultivation to obtain specific nonvolatile taste components with high levels.
- Open Access
- 18 May 2015
- Published by American Physical Society (APS) in Physical Review Special Topics - Accelerators and Beams
- Vol. 18 (5) , 050702
Measurements and analysis of a high-brightness electron beam collimated in a magnetic bunch compressor
A collimator located in a magnetic bunch compressor of a linear accelerator driven x-ray free electron laser has many potential applications, such as the removal of horns in the current distribution, the generation of ultrashort beams, and as a diagnostic of the beam slice emittance. Collective effects, however, are a major concern in applying the technique. Systematic measurements of emittance and analysis were performed using a collimator in the first bunch compressor of the Linac Coherent Light Source (LCLS). In the nominal, undercompressed configuration using the collimator we find that the emittance (nonbending plane) is not increased, and the emittance (in the bending plane) is increased by about 25%, in comparison to the injector emittance. From the analysis we conclude that the parasitic effects associated with this method are dominated by coherent synchrotron radiation (CSR), which causes a “systematic error” for measuring slice emittance at the bending plane using the collimation method. In general, we find good agreement between the measurements and simulations including CSR. However, for overcompressed beams at smaller collimator gaps, an extra emittance increase is found that does not agree with 1D simulations and is not understood.- 18 May 2015
- Published by American Physical Society (APS) in Physical Review Special Topics - Accelerators and Beams
- Vol. 18 (5) , 050702
Open AccessMeasurements and analysis of a high-brightness electron beam collimated in a magnetic bunch compressor
A collimator located in a magnetic bunch compressor of a linear accelerator driven x-ray free electron laser has many potential applications, such as the removal of horns in the current distribution, the generation of ultrashort beams, and as a diagnostic of the beam slice emittance. Collective effects, however, are a major concern in applying the technique. Systematic measurements of emittance and analysis were performed using a collimator in the first bunch compressor of the Linac Coherent Light Source (LCLS). In the nominal, undercompressed configuration using the collimator we find that the emittance (nonbending plane) is not increased, and the emittance (in the bending plane) is increased by about 25%, in comparison to the injector emittance. From the analysis we conclude that the parasitic effects associated with this method are dominated by coherent synchrotron radiation (CSR), which causes a “systematic error” for measuring slice emittance at the bending plane using the collimation method. In general, we find good agreement between the measurements and simulations including CSR. However, for overcompressed beams at smaller collimator gaps, an extra emittance increase is found that does not agree with 1D simulations and is not understood. - Open Access
- 9 March 2015
- Published by American Physical Society (APS) in Physical Review Special Topics - Accelerators and Beams
- Vol. 18 (3) , 030704
Time-resolved imaging of the microbunching instability and energy spread at the Linac Coherent Light Source
The microbunching instability (MBI) is a well-known problem for high brightness electron beams and has been observed at accelerator facilities around the world. Free-electron lasers (FELs) are particularly susceptible to MBI, which can distort the longitudinal phase space and increase the beam’s slice energy spread (SES). Past studies of MBI at the Linac Coherent Light Source (LCLS) relied on optical transition radiation to infer the existence of microbunching. With the development of the x-band transverse deflecting cavity (XTCAV), we can for the first time directly image the longitudinal phase space at the end of the accelerator and complete a comprehensive study of MBI, revealing both detailed MBI behavior as well as insights into mitigation schemes. The fine time resolution of the XTCAV also provides the first LCLS measurements of the final SES, a critical parameter for many advanced FEL schemes. Detailed MBI and SES measurements can aid in understanding MBI mechanisms, benchmarking simulation codes, and designing future high-brightness accelerators.
- 9 March 2015
- Published by American Physical Society (APS) in Physical Review Special Topics - Accelerators and Beams
- Vol. 18 (3) , 030704
Open AccessTime-resolved imaging of the microbunching instability and energy spread at the Linac Coherent Light Source
The microbunching instability (MBI) is a well-known problem for high brightness electron beams and has been observed at accelerator facilities around the world. Free-electron lasers (FELs) are particularly susceptible to MBI, which can distort the longitudinal phase space and increase the beam’s slice energy spread (SES). Past studies of MBI at the Linac Coherent Light Source (LCLS) relied on optical transition radiation to infer the existence of microbunching. With the development of the x-band transverse deflecting cavity (XTCAV), we can for the first time directly image the longitudinal phase space at the end of the accelerator and complete a comprehensive study of MBI, revealing both detailed MBI behavior as well as insights into mitigation schemes. The fine time resolution of the XTCAV also provides the first LCLS measurements of the final SES, a critical parameter for many advanced FEL schemes. Detailed MBI and SES measurements can aid in understanding MBI mechanisms, benchmarking simulation codes, and designing future high-brightness accelerators.
- Open Access
- 10 September 2012
- Published by American Physical Society (APS) in Physical Review Special Topics - Accelerators and Beams
- Vol. 15 (9) , 090701
Impact of the spatial laser distribution on photocathode gun operation
It is widely believed that a drive laser with uniform temporal and spatial laser profiles is required to generate the lowest emittance beam at the photoinjector. However, for a given 3 ps smooth-Gaussian laser temporal profile, our recent simulations indicate that a truncated-Gaussian laser spatial profile produces an electron beam with smaller emittance. The simulation results are qualitatively confirmed by later analytical calculation, and also confirmed by measurements: emittance reduction of was observed at the linac coherent light source (LCLS) injector with a truncated-Gaussian laser spatial profile at the nominal operating bunch charge of 150 pC. There was a significant secondary benefit—laser transmission through the iris for the truncated-Gaussian profile was about twice that compared to the nearly uniform distribution, which significantly loosens the laser power and quantum efficiency requirements for drive laser system and photocathode. Since February 9, 2012, the drive laser with the truncated-Gaussian spatial distribution has been used for LCLS routine user operations and the corresponding free electron laser power is at least the same as the one when using the nearly uniform spatial profile.- 10 September 2012
- Published by American Physical Society (APS) in Physical Review Special Topics - Accelerators and Beams
- Vol. 15 (9) , 090701
Open AccessImpact of the spatial laser distribution on photocathode gun operation
It is widely believed that a drive laser with uniform temporal and spatial laser profiles is required to generate the lowest emittance beam at the photoinjector. However, for a given 3 ps smooth-Gaussian laser temporal profile, our recent simulations indicate that a truncated-Gaussian laser spatial profile produces an electron beam with smaller emittance. The simulation results are qualitatively confirmed by later analytical calculation, and also confirmed by measurements: emittance reduction of was observed at the linac coherent light source (LCLS) injector with a truncated-Gaussian laser spatial profile at the nominal operating bunch charge of 150 pC. There was a significant secondary benefit—laser transmission through the iris for the truncated-Gaussian profile was about twice that compared to the nearly uniform distribution, which significantly loosens the laser power and quantum efficiency requirements for drive laser system and photocathode. Since February 9, 2012, the drive laser with the truncated-Gaussian spatial distribution has been used for LCLS routine user operations and the corresponding free electron laser power is at least the same as the one when using the nearly uniform spatial profile. - Open Access
- 20 November 2006
- Published by American Physical Society (APS) in Physical Review Special Topics - Accelerators and Beams
- Vol. 9 (11) , 114201
Experimental characterization of the transverse phase space of a 60-MeV electron beam through a compressor chicane
Space charge and coherent synchrotron radiation may deteriorate electron beam quality when the beam passes through a magnetic bunch compressor. This paper presents the transverse phase-space tomographic measurements for a compressed beam at 60 MeV, around which energy the first stage of magnetic bunch compression takes place in most advanced linacs. Transverse phase-space bifurcation of a compressed beam is observed at that energy, but the degree of the space charge-induced bifurcation is appreciably lower than the one observed at 12 MeV.
- 20 November 2006
- Published by American Physical Society (APS) in Physical Review Special Topics - Accelerators and Beams
- Vol. 9 (11) , 114201
Open AccessExperimental characterization of the transverse phase space of a 60-MeV electron beam through a compressor chicane
Space charge and coherent synchrotron radiation may deteriorate electron beam quality when the beam passes through a magnetic bunch compressor. This paper presents the transverse phase-space tomographic measurements for a compressed beam at 60 MeV, around which energy the first stage of magnetic bunch compression takes place in most advanced linacs. Transverse phase-space bifurcation of a compressed beam is observed at that energy, but the degree of the space charge-induced bifurcation is appreciably lower than the one observed at 12 MeV.