Ahmed Niri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ahmed Niri has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Kumaraswamy Nanthakumar
Department of Medicine, Division of Cardiology, Peter Munk Cardiac Centre, Toronto General Hospital, University Health Network , Toronto, Ontario
3 shared publications - Stéphane Massé
The Hull Family Cardiac Fibrillation Management Laboratory, University Health Network, Toronto, ON (T.S., S.M., Y.A., G.M.-S., P.F.H.L., J.A., K.N.).
3 shared publications - Abhishek Bhaskaran
University Health Network, Toronto, Canada
2 shared publications A Al-Shaheen
University Health Network Toronto General Hospital , Toronto , Canada
1 shared publicationA Ben-Dor
Biosense Webster Haifa Technology Centre , Haifa , Israel
1 shared publicationArulalan Velluppillai
Division of Cardiology. Toronto General Hospital University Health Network Toronto Ontario Canada
1 shared publication
Latest Publications
- Open Access
- 24 May 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (Supplement)
A method to identify which patients will have VT substrate ablation targets prior to ablation procedure
Funding Acknowledgements: Type of funding sources: Foundation. Main funding source(s): Dr Nanthakumar is a recipient of the Mid-career Investigator Award from the Heart & Stroke Foundation of Ontario Background: Recent trials in ventricular tachycardia (VT) ablation suggest that early ablation could reduce VT burden. A method to predict which patients will have substrate ablation targets based on non-invasive testing prior to the procedure does not exist and could be of value in selecting ideal patients for early VT substrate ablation. Decrement-evoked potential (DeEP) mapping is used to identify VT substrate ablation targets.1 A method for predicting which patients would have DeEP targets on a pre-ablation 12-lead ECG has not yet been developed. Objective: To develop a metric to predict the presence of physiological substrate VT ablation targets from the 12-lead ECG. Method: 22 electrophysiology (EP) lab VT cases that had undergone DeEP mapping were extracted from the CARTO® 3 system and were analysed retrospectively. For each case, DeEP was calculated by subtracting last component of the nearfield evoked response in the pacing train (S1) from the latest component of the nearfield evoked decremented response of the extra stimulus (S2). By inference, 12-lead ECG prediction was calculated by subtracting the width of the 12-lead surface ECG envelope of S1 from the width of the 12-lead ECG envelope of S2. Cases were divided into three categories: - Cases displaying intracardiac DeEP between 0-10ms – no ablation targets - Cases displaying intracardiac DeEP between 10-50ms – DeEP positive - Cases displaying intracardiac DeEP >50ms – prominent DeEP present Results: Out of the 22 cases, 8 were characterised as no ablation targets, 12 as DeEP positive, and 2 as prominent DeEP present. The 12-lead surface ECG measurement means were 3.5±4.6ms for the no ablation target group, 23.2±9.1ms for positive DeEP group, and 80.9±8.1ms for prominent DeEP group. The surface ECG decrement was significantly different P<0.0001 between the three groups. Consequently, we propose that ECG QRS widening of envelope width of 20ms or more may indicate the presence of DeEP targets during invasive mapping. Conclusion: It may be possible to detect which patients will have substrate ablation targets based on 12-lead ECG, prior to the VT ablation procedure. Additionally, this prediction rule, based on its association with arrhythmogenic potentials, may be able to predict which ambulatory patients who have not had manifest VT, may be prone to develop VT thus help identify early VT ablation candidates. This concept should be validated in larger data sets and is ideal for training and testing using surface ECG envelopes with artificial intelligence algorithms.
- 24 May 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (Supplement)
Open AccessA method to identify which patients will have VT substrate ablation targets prior to ablation procedure
Funding Acknowledgements: Type of funding sources: Foundation. Main funding source(s): Dr Nanthakumar is a recipient of the Mid-career Investigator Award from the Heart & Stroke Foundation of Ontario Background: Recent trials in ventricular tachycardia (VT) ablation suggest that early ablation could reduce VT burden. A method to predict which patients will have substrate ablation targets based on non-invasive testing prior to the procedure does not exist and could be of value in selecting ideal patients for early VT substrate ablation. Decrement-evoked potential (DeEP) mapping is used to identify VT substrate ablation targets.1 A method for predicting which patients would have DeEP targets on a pre-ablation 12-lead ECG has not yet been developed. Objective: To develop a metric to predict the presence of physiological substrate VT ablation targets from the 12-lead ECG. Method: 22 electrophysiology (EP) lab VT cases that had undergone DeEP mapping were extracted from the CARTO® 3 system and were analysed retrospectively. For each case, DeEP was calculated by subtracting last component of the nearfield evoked response in the pacing train (S1) from the latest component of the nearfield evoked decremented response of the extra stimulus (S2). By inference, 12-lead ECG prediction was calculated by subtracting the width of the 12-lead surface ECG envelope of S1 from the width of the 12-lead ECG envelope of S2. Cases were divided into three categories: - Cases displaying intracardiac DeEP between 0-10ms – no ablation targets - Cases displaying intracardiac DeEP between 10-50ms – DeEP positive - Cases displaying intracardiac DeEP >50ms – prominent DeEP present Results: Out of the 22 cases, 8 were characterised as no ablation targets, 12 as DeEP positive, and 2 as prominent DeEP present. The 12-lead surface ECG measurement means were 3.5±4.6ms for the no ablation target group, 23.2±9.1ms for positive DeEP group, and 80.9±8.1ms for prominent DeEP group. The surface ECG decrement was significantly different P<0.0001 between the three groups. Consequently, we propose that ECG QRS widening of envelope width of 20ms or more may indicate the presence of DeEP targets during invasive mapping. Conclusion: It may be possible to detect which patients will have substrate ablation targets based on 12-lead ECG, prior to the VT ablation procedure. Additionally, this prediction rule, based on its association with arrhythmogenic potentials, may be able to predict which ambulatory patients who have not had manifest VT, may be prone to develop VT thus help identify early VT ablation candidates. This concept should be validated in larger data sets and is ideal for training and testing using surface ECG envelopes with artificial intelligence algorithms.
- Open Access
- 4 January 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (3) , 1172-1182
Orientation of conduction velocity vectors on cardiac mapping surfaces
Electroanatomical maps using automated conduction velocity (CV) algorithms are now being calculated using two-dimensional (2D) mapping tools. We studied the accuracy of mapping surface 2D CV, compared to the three-dimensional (3D) vectors, and the influence of mapping resolution in non-scarred animal and human heart models. Two models were used: a healthy porcine Langendorff model with transmural needle electrodes and a computer stimulation model of the ventricles built from an MRI-segmented, excised human heart. Local activation times (LATs) within the 3D volume of the mesh were used to calculate true 3D CVs (direction and velocity) for different pixel resolutions ranging between 500 μm and 4 mm (3D CVs). CV was also calculated for endocardial surface-only LATs (2D CV). In the experimental model, surface (2D) CV was faster on the epicardium (0.509 m/s) compared to the endocardium (0.262 m/s). In stimulation models, 2D CV significantly exceeded 3D CVs across all mapping resolutions and increased as resolution decreased. Three-dimensional and 2D left ventricle CV at 500 μm resolution increased from 429.2 ± 189.3 to 527.7 ± 253.8 mm/s (P < 0.01), respectively, with modest correlation (R = 0.64). Decreasing the resolution to 4 mm significantly increased 2D CV and weakened the correlation (R = 0.46). The majority of CV vectors were not parallel (<30°) to the mapping surface providing a potential mechanistic explanation for erroneous LAT-based CV over-estimation. Ventricular CV is overestimated when using 2D LAT-based CV calculation of the mapping surface and significantly compounded by mapping resolution. Three-dimensional electric field-based approaches are needed in mapping true CV on mapping surfaces. Leftward panel: Orientation vectors projecting from a basal view of the endocardium (blue, 3D true CV and pink, 2D CV). Top rightward panel: 3D and 2D CV vector parallel (30° in red). Bottom rightward panel: Distribution histogram showing increased 2D CV (pink) compared to the 3D CV (blue). 2D, two-dimensional; 3D, three-dimensional; CV, conduction velocity; EAM, electroanatomical mapping; EGM, electrogram; LAT, local activation time; LV, left ventricle; RV, right ventricle; VT, ventricular tachycardia
- 4 January 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (3) , 1172-1182
Open AccessOrientation of conduction velocity vectors on cardiac mapping surfaces
Electroanatomical maps using automated conduction velocity (CV) algorithms are now being calculated using two-dimensional (2D) mapping tools. We studied the accuracy of mapping surface 2D CV, compared to the three-dimensional (3D) vectors, and the influence of mapping resolution in non-scarred animal and human heart models. Two models were used: a healthy porcine Langendorff model with transmural needle electrodes and a computer stimulation model of the ventricles built from an MRI-segmented, excised human heart. Local activation times (LATs) within the 3D volume of the mesh were used to calculate true 3D CVs (direction and velocity) for different pixel resolutions ranging between 500 μm and 4 mm (3D CVs). CV was also calculated for endocardial surface-only LATs (2D CV). In the experimental model, surface (2D) CV was faster on the epicardium (0.509 m/s) compared to the endocardium (0.262 m/s). In stimulation models, 2D CV significantly exceeded 3D CVs across all mapping resolutions and increased as resolution decreased. Three-dimensional and 2D left ventricle CV at 500 μm resolution increased from 429.2 ± 189.3 to 527.7 ± 253.8 mm/s (P < 0.01), respectively, with modest correlation (R = 0.64). Decreasing the resolution to 4 mm significantly increased 2D CV and weakened the correlation (R = 0.46). The majority of CV vectors were not parallel (<30°) to the mapping surface providing a potential mechanistic explanation for erroneous LAT-based CV over-estimation. Ventricular CV is overestimated when using 2D LAT-based CV calculation of the mapping surface and significantly compounded by mapping resolution. Three-dimensional electric field-based approaches are needed in mapping true CV on mapping surfaces. Leftward panel: Orientation vectors projecting from a basal view of the endocardium (blue, 3D true CV and pink, 2D CV). Top rightward panel: 3D and 2D CV vector parallel (30° in red). Bottom rightward panel: Distribution histogram showing increased 2D CV (pink) compared to the 3D CV (blue). 2D, two-dimensional; 3D, three-dimensional; CV, conduction velocity; EAM, electroanatomical mapping; EGM, electrogram; LAT, local activation time; LV, left ventricle; RV, right ventricle; VT, ventricular tachycardia
- Open Access
- 27 July 2021
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 44 (10) , 1781-1785
High density intramural mapping of post‐infarct premature ventricular contractions and ventricular tachycardia
Background : Spontaneous ventricular premature contractions (PVCs) and ventricular tachycardia (VT) in the acute post infarct milieu is assumed to be due to automaticity. However, the mechanism has not been studied with intramural mapping. Objective : To study the mechanism of spontaneous PVCs with high density intramural mapping in a canine model, and to test the hypothesis that post-infarct PVCs and VT are due to re-entry rather than automaticity. Methods : In 15 anesthetized dogs, using 768 intramural unipolar electrograms, simultaneous recordings were made. After 20 mins of stabilization, recordings were made during the first 10 minutes of ischemia, and activation maps of individual beats were constructed. Acute ischemia was produced by clamping the left anterior descending coronary artery proximal to the first diagonal branch. Results : In all experiments ST-T alternans was present. Spontaneous ventricular beats occurred in 5 of 15 dogs where the earliest ectopic activity was manifested in the endocardium, well within the ischemic zone. From there, activity spread rapidly along the subendocardium, with endo-to epicardial spread along the non-ischemic myocardium. Epicardial breakthrough always occurred at the border of the ischemic myocardium. In 3 dogs, delayed potentials were observed, which were earliest at the ischemic epicardium and extended transmurally with increasing delay towards the endocardium, where they culminated in a premature beat. A similar sequence was observed in VT that followed. Conclusion : Graded responses that occur with each sinus beat intramurally, when able to propagate from epicardium to endocardium is the mechanism of PVCs and VT in post-infarct myocardium. This article is protected by copyright. All rights reserved
- 27 July 2021
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 44 (10) , 1781-1785
Open AccessHigh density intramural mapping of post‐infarct premature ventricular contractions and ventricular tachycardia
Background : Spontaneous ventricular premature contractions (PVCs) and ventricular tachycardia (VT) in the acute post infarct milieu is assumed to be due to automaticity. However, the mechanism has not been studied with intramural mapping. Objective : To study the mechanism of spontaneous PVCs with high density intramural mapping in a canine model, and to test the hypothesis that post-infarct PVCs and VT are due to re-entry rather than automaticity. Methods : In 15 anesthetized dogs, using 768 intramural unipolar electrograms, simultaneous recordings were made. After 20 mins of stabilization, recordings were made during the first 10 minutes of ischemia, and activation maps of individual beats were constructed. Acute ischemia was produced by clamping the left anterior descending coronary artery proximal to the first diagonal branch. Results : In all experiments ST-T alternans was present. Spontaneous ventricular beats occurred in 5 of 15 dogs where the earliest ectopic activity was manifested in the endocardium, well within the ischemic zone. From there, activity spread rapidly along the subendocardium, with endo-to epicardial spread along the non-ischemic myocardium. Epicardial breakthrough always occurred at the border of the ischemic myocardium. In 3 dogs, delayed potentials were observed, which were earliest at the ischemic epicardium and extended transmurally with increasing delay towards the endocardium, where they culminated in a premature beat. A similar sequence was observed in VT that followed. Conclusion : Graded responses that occur with each sinus beat intramurally, when able to propagate from epicardium to endocardium is the mechanism of PVCs and VT in post-infarct myocardium. This article is protected by copyright. All rights reserved