CWClayton B. Walker

Clayton B. Walker

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Clayton B. Walker has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Multimodal microscope for optical coherence microscopy, tomography, vibrometry, and two-photon microscopy in the living mouse cochlea

    by Clayton B. Walker, Michael J. Serafino, Patricia M. Quiñones, James B. Dewey, John S. Oghalai, Brian E. Applegate

    SignificanceOur understanding of mechanotransduction in mammalian inner ears remains incomplete, in part due to imaging limitations: current systems cannot simultaneously provide high-resolution images needed for subcellular analysis and the deep focus required for structural mechanics. Optical coherence tomography (OCT) enables structural and vibrational imaging through the bone of the intact cochlea in models such as mice, supporting studies of cochlear mechanics in animals with functional hearing. However, capturing both cellular (200 μm) details requires rapid switching between optical configurations with numerical apertures ranging from 0.13 to 0.8. A spectral-domain OCT system combined with two-photon fluorescence microscopy (TPM) and interchangeable objectives could overcome this challenge, enabling high-precision vibration and fluorescence imaging across multiple scales in a single experiment.AimWe aim to develop an integrated OCT and two-photon microscope optimized for imaging the morphology and function of the cochlea.ApproachWe integrated a custom SD-OCT/TPM system into an upright microscope with a high-precision stage for animal positioning. The system uses two tunable liquid lenses to form a beam expander, enabling dynamic adjustment of the beam diameter at the back aperture of each objective. This optimized light throughput and maintained a high signal-to-noise ratio (SNR) across all objectives. In addition, we automated optical adjustments to facilitate seamless imaging with a wide range of objectives.ResultsFor each objective, we measured the SNR difference between a beam expanded to match the largest back aperture and a beam adjusted to match the back aperture of the objective. Except for the 4× objective, the measured SNR improvements closely matched theoretical predictions. Using four selected objectives spanning the required numerical aperture (NA) range, we successfully imaged excised murine cochlea samples, obtaining relevant structural information across scales. In living murine models, we used TPM to locate fluorescent outer hair cells and make vibrometry measurements through the round window membrane. We found that hair cells, the basilar membrane, and the reticular lamina moved in phase in response to a 70 kHz stimulus at 90 dB SPL, consistent with expected cochlear mechanics.ConclusionsAutomation and optimization of the optical system enabled seamless multiscale imaging of the murine cochlea, providing high-quality morphological, functional, and two-photon fluorescence images. The dynamic adjustment of the beam diameter within the microscope was essential for maintaining high SNR across a wide range of numerical apertures.


  • Open Access

    Flexible catheter optical coherence tomography of the porcine middle ear via the Eustachian tube using a 3D-printed reflective objective

    by Clayton B. Walker, Kevin Beckford, Zihan Yang, Jinyun Liu, Wihan Kim, Tomasz S. Tkaczyk, Brian E. Applegate

    SignificanceCholesteatomas, benign tumors that grow in the middle ear, can lead to conductive hearing loss. If not completely removed during surgery, these tumors may regrow. Current imaging technologies struggle to detect residual tumors noninvasively due to limitations in contrast and resolution, often necessitating additional surgery for inspection. To address this, we developed a catheter endoscope capable of being inserted through the Eustachian tube, allowing detailed examination of the middle ear without surgery. Using two-photon polymerization (2PP) technology, we fabricated miniature, side-viewing reflective endoscope objectives. This approach enabled the rapid production of single-element objectives with highly repeatable optical properties, easily adaptable to specific imaging needs.AimWe aim to design, fabricate, and demonstrate a catheter endoscope for optical coherence tomography (OCT) endoscopy of the middle ear via the Eustachian tube.ApproachSide-viewing, reflective lenses were designed in OpticStudio and 3D printed using 2PP followed by sputter coating with gold. Standard metrology techniques were used to verify and optimize the objective’s shape. The optical performance of the catheter endoscopes was measured with a beam profiler. Finally, OCT imaging of the middle ear of a pig via the Eustachian tube was completed using the fully assembled catheter endoscope.ResultsMetrology showed the printed lenses conformed closely to the design. The catheter endoscope’s FWHM spot size had a mean ± standard deviation of 25.3±1.8 μm with a measured working distance of 1.960±0.057 mm. Volumetric OCT images of the middle ear, inner ear, and Eustachian tube were captured in a postmortem pig head using the catheter endoscope.ConclusionsThe 2PP approach is fast and highly repeatable for miniature reflective objective fabrication. OCT catheter endoscopy via the Eustachian tube enabled imaging of the middle ear, Eustachian tube, and surprisingly part of the inner ear.


  • Multi-window approach enables two-fold improvement in OCT axial resolution with strong side-lobe suppression and improved phase sensitivity

    by Clayton B. Walker, Anna Wisniowiecki, Jack C. Tang, Patricia M. Quiñones, Wihan Kim, John S. Oghalai, Brian E. Applegate

    A common processing approach for optical coherence tomography (OCT) uses a window function (e.g., Hann or rectangular window) for spectral shaping prior to calculating the Fourier transform. Here we build on a multi-window approach [ Opt. Express 8, 5267 (2017)10.1364/BOE.8.005267 ] that enables improved resolution while still suppressing side-lobe intensity. The shape of the window function defines the trade-off between main-lobe width (resolution) and side-lobe intensity. We have extended the approach to include the interferometric phase for phase-sensitive applications like vibrometry and Doppler OCT. Using the Hann window as a reference, we show that 11 Taylor windows are sufficient to achieve 50% improvement in axial resolution, -31 dB side-lobe intensity, and 20% improvement in phase sensitivity with low computational cost.


  • Open Access

    COVID‐19 in the Clinic: Human Testing of an Aerosol Containment Mask for Endoscopic Clinic Procedures

    by Elisabeth H. Ference, Wihan Kim, John S. Oghalai, Clayton B. Walker, Jee‐Hong Kim, Tyler Gallagher, Harrison J. Ma, Brian E. Applegate

    Objective: To create an aerosol containment mask (ACM) for common otolaryngologic endoscopic procedures that also provides nanoparticle‐level protection to patients.Study Design: Prospective feasibility study.Setting: In‐person testing with a novel ACM.Methods: The mask was designed in Solidworks and 3D printed. Measurements were made on 10 healthy volunteers who wore the ACM while reading the Rainbow Passage repeatedly and performing a forced cough or sneeze at 5‐second intervals over 1 minute with an endoscope in place.Results: There was a large variation in the number of aerosol particles generated among the volunteers. Only the sneeze task showed a significant increase compared with normal breathing in the 0.3‐µm particle size when compared with a 1‐tailed t test (P =. 013). Both the 0.5‐µm and 2.5‐µm particle sizes showed significant increases for all tasks, while the 2 largest particle sizes, 5 and 10 µm, showed no significant increase (both P <. 01). With the suction off, 3 of 30 events (2 sneeze events and 1 cough event) had increases in particle counts, both inside and outside the mask. With the suction on, 2 of 30 events had an increase in particle counts outside the mask without a corresponding increase in particle counts inside the mask. Therefore, these fluctuations in particle counts were determined to be due to random fluctuation in room particle levels.Conclusion: ACM will accommodate rigid and flexible endoscopes plus instruments and may prevent the leakage of patient‐generated aerosols, thus avoiding contamination of the room and protecting health care workers from airborne contagions.Level of evidence: 2