Peng Zhong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Peng Zhong has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Hongtao Lei
South China Agricultural University
2 shared publications Shaozong Wu
Guangdong Provincial Key Laboratory of Food Quality and Safety / National–Local Joint Engineering Research Center for Precision Machining and Safety of Livestock and Poultry Products, College of Food Science South China Agricultural University Guangzhou 510642 China
2 shared publicationsXiaoqun Wei
Guangdong Provincial Key Laboratory of Food Quality and Safety / National–Local Joint Engineering Research Center for Precision Machining and Safety of Livestock and Poultry Products, College of Food Science South China Agricultural University Guangzhou 510642 China
2 shared publicationsAnastasios Koidis
Institute for Global Food Security, Queen’s University Belfast, 19 Chlorine Gardens, Belfast BT9 5DJ, United Kingdom
1 shared publication- Anastasios Koidis
Institute for Global Food Security, School of Biological Sciences, Queen’s University Belfast, Belfast BT9 5DL, UK
1 shared publication Lulu Zhang
Guangdong Province Key Laboratory of Food Quality and Safety, College of Food Science, South China Agricultural University, Guangzhou 510642, China
1 shared publication
Latest Publications
- 29 March 2022
- Published by Wiley in Comprehensive Reviews in Food Science and Food Safety
- Vol. 21 (3) , 2455-2488
Untargeted metabolomics by liquid chromatography‐mass spectrometry for food authentication: A review
Food fraud is currently a growing global concern with far‐reaching consequences. Food authenticity attributes, including biological identity, geographical origin, agricultural production, and processing technology, are susceptible to food fraud. Metabolic markers and their corresponding authentication methods are considered as a promising choice for food authentication. However, few metabolic markers were available to develop robust analytical methods for food authentication in routine control. Untargeted metabolomics by liquid chromatography‐mass spectrometry (LC‐MS) is increasingly used to discover metabolic markers. This review summarizes the general workflow, recent applications, advantages, advances, limitations, and future needs of untargeted metabolomics by LC‐MS for identifying metabolic markers in food authentication. In conclusion, untargeted metabolomics by LC‐MS shows great efficiency to discover the metabolic markers for the authenticity assessment of biological identity, geographical origin, agricultural production, processing technology, freshness, cause of animals’ death, and so on, through three main steps, namely, data acquisition, biomarker discovery, and biomarker validation. The application prospects of the selected markers by untargeted metabolomics require to be valued, and the selected markers need to be eventually applicable at targeted analysis assessing the authenticity of unknown food samples.
- 29 March 2022
- Published by Wiley in Comprehensive Reviews in Food Science and Food Safety
- Vol. 21 (3) , 2455-2488
Untargeted metabolomics by liquid chromatography‐mass spectrometry for food authentication: A review
Food fraud is currently a growing global concern with far‐reaching consequences. Food authenticity attributes, including biological identity, geographical origin, agricultural production, and processing technology, are susceptible to food fraud. Metabolic markers and their corresponding authentication methods are considered as a promising choice for food authentication. However, few metabolic markers were available to develop robust analytical methods for food authentication in routine control. Untargeted metabolomics by liquid chromatography‐mass spectrometry (LC‐MS) is increasingly used to discover metabolic markers. This review summarizes the general workflow, recent applications, advantages, advances, limitations, and future needs of untargeted metabolomics by LC‐MS for identifying metabolic markers in food authentication. In conclusion, untargeted metabolomics by LC‐MS shows great efficiency to discover the metabolic markers for the authenticity assessment of biological identity, geographical origin, agricultural production, processing technology, freshness, cause of animals’ death, and so on, through three main steps, namely, data acquisition, biomarker discovery, and biomarker validation. The application prospects of the selected markers by untargeted metabolomics require to be valued, and the selected markers need to be eventually applicable at targeted analysis assessing the authenticity of unknown food samples.
- 28 July 2021
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 69 (31) , 8861-8873
Integration of Untargeted and Pseudotargeted Metabolomics for Authentication of Three Shrimp Species Using UHPLC-Q-Orbitrap
In this work, an untargeted and pseudotargeted metabolomics combination approach was used for authentication of three shrimp species (Litopenaeus vanmamei, Penaeus japonicus, and Penaeus monodon). The monophasic extraction-based untargeted metabolomics approach enabled comprehensive-coverage and high-throughput analysis of shrimp tissue and revealed 26 potential markers. The pseudotargeted metabolomics approach confirmed 21 markers (including 9 key markers), which realized at least putative identification. The 21 confirmed markers, as well as 9 key markers, were used to develop PLS-DA models, correctly classifying 60/60 testing samples. Furthermore, DD-SIMCA and PLS-DA models were integrated based on the 9 key markers, with 59/60 and 20/20 samples of the species that were involved and uninvolved in model training correctly classified. The results demonstrated the potential of this untargeted and pseudotargeted metabolomics combination approach for shrimp species authentication.
- 28 July 2021
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 69 (31) , 8861-8873
Integration of Untargeted and Pseudotargeted Metabolomics for Authentication of Three Shrimp Species Using UHPLC-Q-Orbitrap
In this work, an untargeted and pseudotargeted metabolomics combination approach was used for authentication of three shrimp species (Litopenaeus vanmamei, Penaeus japonicus, and Penaeus monodon). The monophasic extraction-based untargeted metabolomics approach enabled comprehensive-coverage and high-throughput analysis of shrimp tissue and revealed 26 potential markers. The pseudotargeted metabolomics approach confirmed 21 markers (including 9 key markers), which realized at least putative identification. The 21 confirmed markers, as well as 9 key markers, were used to develop PLS-DA models, correctly classifying 60/60 testing samples. Furthermore, DD-SIMCA and PLS-DA models were integrated based on the 9 key markers, with 59/60 and 20/20 samples of the species that were involved and uninvolved in model training correctly classified. The results demonstrated the potential of this untargeted and pseudotargeted metabolomics combination approach for shrimp species authentication.