XPXavier Proaño

Xavier Proaño

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xavier Proaño has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Análisis del impacto de generación distribuida en el alimentador 0602SR0T04 mediante simulación en opendss

    by Andy Israel Sarabia Chicaiza, Jefferson Israel Chicaiza Tandalla, Quinatoa Caiza Carlos Iván, Xavier Alfonso Proaño Maldonado

    El presente trabajo analiza el impacto de inyectar generación distribuida (GD) en el alimentador 0602SR0T04 de la ciudad de Latacunga, Ecuador. El objetivo central de estudio es evaluar qué efectos produce la inserción estratégica de sistemas fotovoltaicos, y como estos influyen en variables de la red de distribución. La metodología parte de la recolección de datos técnicos de los elementos conectados a la red, y datos georreferenciales, proporcionados por la Empresa Eléctrica Provincial Cotopaxi (ELEPCO S.A.), posteriormente estos fueron procesados mediante filtros de datos para construir una simulación de la red eléctrica de dicho alimentador en el software OpenDSS. Una vez construida la simulación, se incorporaron perfiles de irradiación solar obtenidos en línea, de la web POWER, de la NASA, para representar la radiación real de la zona. El modelo eléctrico permitió simular escenarios de penetración de generación distribuida con porcentajes escalonados (0, 25, 50, 75 y 100 por ciento), seleccionando al azar usuarios con distintos valores de consumo promedio. Se identificaron los beneficios operativos en las redes con generación distribuida asociados a la inyección de energía en niveles de baja tensión. Los resultados muestran un impacto favorable en los perfiles de tensión, reducción de corriente y reducción de pérdidas, que incrementan su efecto a medida que incrementa el porcentaje de GD. Se concluye que, si se implementa la red simulada, cumpliría la norma IEEE 1547-2018 si se inyecta GD al 100%. Se tiene disponible la simulación de la red eléctrica y los datos originales en la data suplementaria.

  • Open Access

    Coordinación De Protecciones en la Central Hidroeléctrica Río Verde Chico

    by Xavier Alfonso Proaño Maldonado, Diego Enrique Estupiñán Tello, Carlos Andrés Molina Salazar

    El presente artículo presenta el trabajo realizado en la Central Hidroeléctrica Río Verde Chico, que tuvo como objetivo estudiar la coordinación de protecciones eléctricas en el sistema de potencia. El estudio se basó en realizar simulaciones de las principales protecciones eléctricas, de lo cual se pudo determinar que existían protecciones que estaban mal configuradas lo que actualmente provoca disparos erróneos de las unidades de generación y las líneas de transmisión. Para el estudio de coordinación de protecciones se consideró modelar los tres escenarios en las que la Central puede trabajar, mediante herramientas informáticas que permitan simular condiciones de mínima y máxima generación, las fallas que se deben presentar en el estudio son para sobrecargas y corrientes de cortocircuito para fallas trifásicas y fase a tierra o monofásicas según recomendaciones de la norma IEC 60909-0. De los resultados obtenidos en las simulaciones en el capítulo 3 de este trabajo de investigación se propone realizar cambios en las siguientes protecciones eléctricas, para las líneas de transmisión: Protección de distancia ANSI 21, protección de sobre corriente ANSI 50/51, para el transformador de potencia: protección diferencial ANSI 87T, protección de sobrecorriente ANSI 50/51, para los generadores: protección de sobrecorriente ANSI 50/51, y se activa la protección sobrecorriente controlada por voltaje ANSI 51V.

  • Open Access

    Optimización Acelerada del Flujo de Potencia Mediante Técnicas de Aproximación Lineal

    by Kevin Velasco, Gabriel Pesantez, Wilian Guamán, Xavier Proaño, Paul Acapiña

    La resolución de problemas de flujo de potencia óptimo (OPF) se hace cada vez más compleja a medida que aumenta el tamaño del sistema eléctrico. Para hacer frente a esta situación, se emplean diversas técnicas para acelerar el proceso de solución. Un método comúnmente utilizado es la aproximación DC, que simplifica el problema, pero conlleva una cierta pérdida de información. Este trabajo explora la implementación de un algoritmo diseñado para optimizar los cálculos OPF mediante el uso de Aproximaciones Lineales Sucesivas (LSA), basado en el Modelo de Inyección en Bus (BIM) para el análisis del flujo de potencia. Este enfoque comienza con un modelo de relajación convexo, que luego se transforma en una serie de LSA, lo que permite un cálculo más rápido al tiempo que produce soluciones aceptables. Durante la ejecución del algoritmo, se seleccionan datos esenciales del sistema eléctrico estudiado, se evalúan y se comparan con los resultados obtenidos al aplicar el OPF clásico. Las soluciones producidas por el enfoque LSA satisfacen las restricciones operativas del sistema a la vez que reducen significativamente el tiempo de cálculo. Se puede concluir que, a medida que aumenta el número de buses, también crece la cantidad de variables y el tiempo de resolución. En este sentido, la aplicación del método LSA permite reducir los tiempos en más de un 10.00%, manteniendo un error en el cálculo de la potencia por debajo del 7,00%.

  • Open Access

    Desarrollo de un Algoritmo para la Protección contra Descargas Atmosféricas en Edificaciones

    by Carlos Quinatoa, Damián Albán, Xavier Proaño, Luis Camacho

    La investigación se centra en el progreso algorítmica destinada a la protección contra los impactos atmosféricos en estructuras que utilizan la técnica de esferas rodantes. La metodología comienza con la recopilación de los detalles del proyecto, que abarcan el nivel ceráunico y las medidas estructurales. Los elementos de riesgo se evalúan en un software de evaluación de riesgos para encontrar algunos escenarios, como la pérdida de vidas, la suspensión del servicio y los daños a la propiedad. De ser necesario, se administran las correcciones; de lo contrario, se ponen en práctica estrategias de protección. Esto incluye determinar la resistividad del suelo de acuerdo con la norma IEEE 81, aplicar la técnica de la esfera rodante de la norma IEC 62305-3 y cumplir con los principios del sistema de puesta a tierra en las normas IEEE 142 e IEEE 80. Para analizar las descargas atmosféricas dentro de una estructura protegida, se calculan los equivalentes eléctricos de los conductores de malla, las varillas de soldadura de cobre y los conductores horizontales y verticales. Los resultados se utilizan en un circuito de Atpdraw vinculado a Python, que genera gráficas de las formas de onda actuales para diversos subsistemas de protección. Los elementos de riesgo se reevalúan para ratificar el procedimiento. La verificación se basa en la idea de que el margen de error converge hacia cero cuando se introducen datos de ejercicios que cumplen con normativas como la IEC y el IEEE.

  • Open Access

    Proposal for a protection system of an industrial electrical network

    by Alex Paúl, Xavier Santiago Salazar Defaz, Xavier Alfonso Proaño Maldonado, Franklin Hernán Vásquez Teneda

    An electrical protection system in an industry Works by detecting and acting against abnormal conditions in the electrical system with the objective of guaranteeing the safety of people, protecting equipment and ensuring the continuity of industrial process. Taking into account the importance of guaranteeing adequate electrical protection system in an industrial activity in this research a proposal for the protection system for an industrial electrical network is presented. As a previous step proposal, the methodology desingned for the coordination of protections for an industrial electrical network was proposed. The proposal was designed taking into account four operating scenarios required to calibrate the industry’s protection devices. The short circuit analysis maximum in each of the system bars for each of the scenarios allowed determining the maximum phase failure currents it is 44,44 % for emergency 1 and 66,66 % for emergency 2, while the maximum ground fault current was founding emergency scenario2. At the news to the four scenarios of the industrial network in the actuation times of the devices of protection, there is not considerable variation; this is justified by the current time graph because when there is a serious short circuit current, the action time should be shorter. On the contrary, when there is a small current time will be greater

  • Open Access

    Integration of electromagnetic and mechanical models for effective lightning protection in buildings

    by Carlos Ivan Quinatoa Caiza, Alex Ivan Paguay Llamuca, Xavier Alfonso Proaño Maldonado

    The study focused on the design of an advanced algorithm for the optimal sizing of protection systems against atmospheric discharges in architectural structures, applying the rolling sphere method. This technique facilitated the incorporation of user-specified parameters through an advanced graphical interface. The methodology began with the exhaustive accumulation of data relevant to the project. Risk indices were estimated through sophisticated risk analysis software applications. If adjustments were required, the process continued; If not, the building was considered to be adequately secured. The ground resistivity was evaluated according to IEEE Std. 81, and the rolling sphere method was implemented according to IEC 662305-3. The grounding systems were configured in accordance with IEEE Std. 142 and IEEE Std. 80. To analyze the interaction of electrical discharges with the protected building, the electrical equivalents of elements such as meshes, fused copper rods were computed. , and conductors positioned horizontally and vertically. Using these data, a model was built in ATPDraw, interconnected with Python for the generation of graphical representations of the current waves in the different protection subsystems. To conclude and corroborate the effectiveness of the process, the risk indices were reevaluated. The validation of the algorithm was achieved by minimizing the margin of error to insignificant levels by incorporating standardized data proposed by organizations such as IEC and IEEE, thus confirming the precision of the designed algorithm

  • Open Access

    Evaluación del Funcionamiento de la Protección Diferencial 87 en Transformadores Monofásicos Ante Presencia de Fallas, Mediante un Prototipo Didáctico

    by Xavier Proaño, Gabriela Bonilla, Edgar Barahona, Wilian Guamán

    En el presente trabajo se realizó la construcción de un prototipo didáctico que permite evaluar el funcionamiento de la protección diferencial 87, mediante la parametrización de variables, para lo cual se consideran varios parámetros, como la corriente mínima de operación, la corriente de arranque o la pendiente de operación, los cuales conjuntamente con los datos medidos, como la corriente el primario y secundario, que posibilitan determinar el valor correspondiente a la corriente diferencial, permitiendo emular la función de protección diferencial 87 y su variante porcentual. Para lograr lo anteriormente expuesto, se empleó sensores de corriente de Arduino, los cuales en conjunto con el microprocesador Nano, de la misma marca, permitirá la toma de datos, lo cuales tras su procesamiento, serán comunicados a LabVIEW donde se emplea una constante, la cual permite escalar los valores obtenidos para así, poder desarrollar la lógica de programación que permite el ingreso de parámetros, selección de TC’s, cálculo de la corriente diferencial y mínima de operación, así como también la identificación de las zonas de operación.


  • Open Access

    Desarrollo de una Aplicación Informática para la Calibración y Coordinación del Relevador de Sobre Corriente 50/51

    by Xavier Proaño, Cristian Castillo, Geovanny Rosales, Wilian Guamán, Gabriel Pesantez

    En el presente trabajo se realizó el desarrollo de una aplicación informática para la coordinación y calibración de los relevadores de sobrecorriente 50/51 para sistemas radiales, mediante esta aplicación se llegó a observar las gráficas de las curvas de los relevadores modificando las variables de entrada como son Corriente del Tap (51) y Corriente del Instantáneo (50), TCs, Tipos de Curvas y su Dial para cada una de ellas, con el fin de calibrar y coordinar las protecciones entre curvas mediante el tiempo de actuación entre los Relevadores, en el programa Coordinación de Protección de sobrecorriente eléctrica (CPSElectric) desarrollado mediante la herramienta de programación Matlab r2019a, que se usó una de las aplicaciones incorporadas de esta plataforma como es la App Designer siendo está una de las nuevas opciones de programación en Matlab r2019a que permite reducir el tiempo de desarrollo de interfaces y la facilidad del diseño de las Aplicaciones para lo cual nos permite que el programa sea más interactivo a la hora de su uso ya que está enfocado para formar parte de laboratorio de protecciones eléctricas de la Universidad Técnica de Cotopaxi mejorando el aprendizaje de los estudiantes a la hora de debatir sobre las protección de sobrecorriente 50/51, permitiendo obtener la visualización de resultados como son los tiempos de operación de las corrientes del Instantáneo (50) y su tiempo de margen de operación entre curvas de forma gráfica para garantizar los resultados se basó a diferentes normas estandarizadas como son la IEEE Std C37.112-2018 “Estándar para ecuaciones de características de tiempo inverso para relés de sobrecorriente” y la IEC 60255-3 “Relés de medidas y equipos de protección.”

  • Open Access

    Diseño de un Sistema Fotovoltaico Conectado a la Red en el Bloque B de la Universidad Técnica de Cotopaxi

    by Paúl Potes, Xavier Proaño

    El presente proyecto de investigación cuantificó la cantidad de energía que un sistema fotovoltaico conectado a la red, puede suministrar al bloque B de la Universidad Técnica de Cotopaxi, con el propósito de disminuir la facturación del servicio eléctrico. En el proyecto se recolectó la radiación global por el periodo de un año, datos que ayudaron a determinar el potencial solar de la institución. La mayor irradiación promedio presentada fue en noviembre con un valor de 5,4 kW∙h/(m2∙día) e irradiancia media máxima de 931 W/m2 a la 1:00 pm. La demanda semanal del bloque académico B fue estimada con el Analizador Fluke 435 series II, mismo que registró una potencia promedio máxima de 35,11 kW el día miércoles a las 18:00 h. Además, a la 1:00 pm del jueves donde se encontró la mayor irradiancia, midió un valor medio de 29,88 kW. El generador fotovoltaico cuenta con 66 paneles solares, cuya capacidad instalada es de 26,4 kW dividida en dos grupos: 14,4 kW y 12 kW, respectivamente ubicados sobre la azotea del edificio en un área libre de 573,47 m2. De esta manera, el sistema podría entregar anualmente 30336 kW∙h a la institución, a la vez; evitar la emisión de 18,42 toneladas de CO2 al año. Finalmente, en el estudio financiero del proyecto con una inversión de 83.290,88 USD, se consideró tres escenarios; el segundo la mejor opción, cuando el precio de la energía eléctrica es de 0,6812 USD/kW∙h. Esto implica tener un ingreso anual de 21.078,37 USD, un valor actual neto de 116.363,42 USD, tasa interna de retorno del 24,07% y relación beneficio/costo de 2,28.


  • Open Access

    Diseño de un Sistema de Alumbrado LED a través de Energía Fotovoltaica para Brindar Niveles de Calidad de Iluminación en el Parqueadero N° 1 de la Universidad Técnica de Cotopaxi

    by Diego Jiménez, Xavier Proaño

    En el presente trabajo se realizó el diseño y análisis de un sistema de iluminación exterior mediante tecnología LED, el cual es energizado por medio de generación fotovoltaica concentrada. Considerando que, en el estacionamiento se cuenta con una iluminación media inferior a los niveles permitidos, se propone la mejora del alumbrado a través del software Dialux evo, obteniendo de este diseño los siguientes resultados: 518 lx para el acceso, 132,83 lx en la franja de circulación y 113,75 lx en plazas de estacionamiento, acordes a la normativa NTE INEN 2 248, cuya densidad de potencia eléctrica para alumbrado es de 1,88 W/m2. Mediante una investigación bibliográfica se recopiló los datos técnicos de las luminarias LED de 245 W y 134 W, con un eficiencia luminosa de 145 lm/W y 146 lm/W respectivamente. Además, el sistema fotovoltaico está conformado por 28 paneles monocristalinos de 360 W/24 V, el sistema de acumulación constará de 28 baterías de descarga profunda a 240 Ah/12 V, dos reguladores de carga PWM de 110 A/48 V y el inversor de 5 000 VA/48 V. Con un nuevo valor para el kWh de USD 0,681 2 se logra tener un VAN de $ 66 525,60 y el TIR igual a 25,35 %, indicando que el proyecto resulta rentable.