Stephen E. Stein
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Stephen E. Stein has a total of 117 co-authors. Here are the top co-authors by number of shared publications:
- Anthony R. H. Goodwin
Schlumberger Technology Corporation, 150 Gillingham Lane, Sugar Land, Texas 77478, United States
28 shared publications Erich Königsberger
28 shared publicationsJohn H. Dymond
28 shared publications- Kenneth N. Marsh
Department of Mechanical and Chemical Engineering, University of Western Australia, Crawley, Western Australia 6009, Australia
28 shared publications - Michael Frenkel
Thermophysical Properties Division, National Institute of Standards and Technology, Boulder, Colorado 80305-3337, United States
28 shared publications - Qian Dong
Mass Spectrometry Data Center, Biomolecular Measurement Division, National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, Maryland 20899, United States
28 shared publications
Latest Publications
- Open Access
- 3 November 2026
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
Gas-Phase Collision-Induced Dissociation of Protonated N -Phenylphthalimide and Its Derivatives
The fragmentation of protonated N-phenylphthalimide (C6H4(CO)2NC6H5) in electrospray ionization generates an unexpected cation (C6H4COCN+) at m/z 130.029 as the most abundant ion by the loss of a neutral phenol molecule. One of the oxygen atoms in the two carbonyl groups is transferred to the phenyl ring by replacing the nitrogen atom. To confirm the oxygen migration to the benzene ring, mono-18O–N-phenylphthalimide was synthesized and subjected to collisional activation, resulting in two similarly abundant ions at m/z 130.029 and m/z 132.033 that corresponded to the 18O cation (C6H4C18OCN+). To confirm that one hydrogen atom on the phenyl ring may mediate the reaction to eliminate a water molecule, deuterated N-phenylphthalimide (C6H4(CO)2NC6D5) was prepared, and its MS/MS spectrum shows a peak at m/z 210.0848, corresponding to a neutral loss of HOD. Moreover, when the phenyl group is replaced by a pentafluorobenzene group (i.e., C6H4(CO)2NC6F5), HF loss is observed but without water loss. A nitrogen–oxygen rearrangement mechanism was proposed, in which the carbonyl oxygen atom mediates nucleophilic substitution of the nitrogen atom of the N-phenyl ring, leading to the loss of neutral phenol. The nitrogen–oxygen rearrangement can be extended to various substituted N-phenylphthalimide compounds, including heterocyclic rings such as triazole, most of which yield nitrogen–oxygen rearrangement ions as major peaks in MS/MS spectra.
- 3 November 2026
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
Open AccessGas-Phase Collision-Induced Dissociation of Protonated N -Phenylphthalimide and Its Derivatives
The fragmentation of protonated N-phenylphthalimide (C6H4(CO)2NC6H5) in electrospray ionization generates an unexpected cation (C6H4COCN+) at m/z 130.029 as the most abundant ion by the loss of a neutral phenol molecule. One of the oxygen atoms in the two carbonyl groups is transferred to the phenyl ring by replacing the nitrogen atom. To confirm the oxygen migration to the benzene ring, mono-18O–N-phenylphthalimide was synthesized and subjected to collisional activation, resulting in two similarly abundant ions at m/z 130.029 and m/z 132.033 that corresponded to the 18O cation (C6H4C18OCN+). To confirm that one hydrogen atom on the phenyl ring may mediate the reaction to eliminate a water molecule, deuterated N-phenylphthalimide (C6H4(CO)2NC6D5) was prepared, and its MS/MS spectrum shows a peak at m/z 210.0848, corresponding to a neutral loss of HOD. Moreover, when the phenyl group is replaced by a pentafluorobenzene group (i.e., C6H4(CO)2NC6F5), HF loss is observed but without water loss. A nitrogen–oxygen rearrangement mechanism was proposed, in which the carbonyl oxygen atom mediates nucleophilic substitution of the nitrogen atom of the N-phenyl ring, leading to the loss of neutral phenol. The nitrogen–oxygen rearrangement can be extended to various substituted N-phenylphthalimide compounds, including heterocyclic rings such as triazole, most of which yield nitrogen–oxygen rearrangement ions as major peaks in MS/MS spectra.
- Open Access
Site-Specific Glycosylation Profiling of Protein Subunit and Inactivated Virus Vaccines
Background/Objectives: Glycosylation can affect vaccine antigen structure and function, making site-specific glycan characterization relevant to antigen quality and comparability. However, quantitative approaches for comparing glycan microheterogeneity remain limited. This study evaluated the utility of the glycopeptide abundance distribution spectra framework for measuring similarity among site-specific glycosylation profiles in vaccines and antigen reference reagents across manufacturing conditions. Methods: Intact N-linked glycopeptides were characterized by nanoflow liquid chromatography–tandem mass spectrometry with stepped-energy fragmentation. Products included monovalent and quadrivalent influenza antigens produced in embryonated eggs, Madin–Darby canine kidney cells, or Spodoptera frugiperda cells, together with a SARS-CoV-2 spike vaccine produced in Spodoptera frugiperda cells and a Chinese hamster ovary cell-produced varicella-zoster virus glycoprotein E vaccine. Site-specific glycan distributions were represented as distribution spectra and compared using NIST MS Search software. Dot-product scores ranging from 0 to 999 quantified similarity. Results: Across measured glycosylation sites, distributions clustered into six recurrent classes. Similarity was high for replicate analyses, conserved influenza components across annual formulations, and matched components from different suppliers within the same production platform (similarity scores = 978, 961, and 960, respectively). Similarity was lower between sites within the same protein, between influenza strains, and between production sources (similarity scores = 554, 540, and 209, respectively). Among production-source comparisons, egg- and Madin–Darby canine kidney-derived profiles were most similar, and the overall ordering of glycosylation similarity was consistent with broad phylogenetic relatedness among production hosts. Conclusions: Distribution spectra-based similarity scoring of vaccine glycoproteins provides a quantitative, reusable approach for documenting site-specific glycosylation microheterogeneity. Using this method, we can conclude that production source is the dominant contributor to variation, whereas replicates, annual formulations, and suppliers within the same production platform are highly consistent.
Open AccessSite-Specific Glycosylation Profiling of Protein Subunit and Inactivated Virus Vaccines
Background/Objectives: Glycosylation can affect vaccine antigen structure and function, making site-specific glycan characterization relevant to antigen quality and comparability. However, quantitative approaches for comparing glycan microheterogeneity remain limited. This study evaluated the utility of the glycopeptide abundance distribution spectra framework for measuring similarity among site-specific glycosylation profiles in vaccines and antigen reference reagents across manufacturing conditions. Methods: Intact N-linked glycopeptides were characterized by nanoflow liquid chromatography–tandem mass spectrometry with stepped-energy fragmentation. Products included monovalent and quadrivalent influenza antigens produced in embryonated eggs, Madin–Darby canine kidney cells, or Spodoptera frugiperda cells, together with a SARS-CoV-2 spike vaccine produced in Spodoptera frugiperda cells and a Chinese hamster ovary cell-produced varicella-zoster virus glycoprotein E vaccine. Site-specific glycan distributions were represented as distribution spectra and compared using NIST MS Search software. Dot-product scores ranging from 0 to 999 quantified similarity. Results: Across measured glycosylation sites, distributions clustered into six recurrent classes. Similarity was high for replicate analyses, conserved influenza components across annual formulations, and matched components from different suppliers within the same production platform (similarity scores = 978, 961, and 960, respectively). Similarity was lower between sites within the same protein, between influenza strains, and between production sources (similarity scores = 554, 540, and 209, respectively). Among production-source comparisons, egg- and Madin–Darby canine kidney-derived profiles were most similar, and the overall ordering of glycosylation similarity was consistent with broad phylogenetic relatedness among production hosts. Conclusions: Distribution spectra-based similarity scoring of vaccine glycoproteins provides a quantitative, reusable approach for documenting site-specific glycosylation microheterogeneity. Using this method, we can conclude that production source is the dominant contributor to variation, whereas replicates, annual formulations, and suppliers within the same production platform are highly consistent.
- Open Access
- 14 July 2026
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 25 (8) , 4315-4321
Analysis and Annotation of c-Type Ions in Peptide Mass Spectral Libraries
The large collection of high-quality mass spectra in the NIST Human HCD Peptide and NIST Tandem Mass Spectral Libraries is used to understand the role of peptide sequence in c-type ion formation in beam-type collision-induced dissociation. Furthermore, results from the analyses were used to inform and apply annotation rules for c-type ions in the updated Human HCD Peptide Mass Spectral Library. As a result, 155,663 c-type ions are now annotated, providing additional peptide sequence information, often where b- and y-type ions may be lacking. Examples shown here highlight the significance of these c-type ions, both in terms of their relative abundance and in resolving peptide-sequence ambiguities. Furthermore, these examples illustrate the value of including c-type ions to improve searching and scoring of peptide spectrum matches.
- 14 July 2026
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 25 (8) , 4315-4321
Open AccessAnalysis and Annotation of c-Type Ions in Peptide Mass Spectral Libraries
The large collection of high-quality mass spectra in the NIST Human HCD Peptide and NIST Tandem Mass Spectral Libraries is used to understand the role of peptide sequence in c-type ion formation in beam-type collision-induced dissociation. Furthermore, results from the analyses were used to inform and apply annotation rules for c-type ions in the updated Human HCD Peptide Mass Spectral Library. As a result, 155,663 c-type ions are now annotated, providing additional peptide sequence information, often where b- and y-type ions may be lacking. Examples shown here highlight the significance of these c-type ions, both in terms of their relative abundance and in resolving peptide-sequence ambiguities. Furthermore, these examples illustrate the value of including c-type ions to improve searching and scoring of peptide spectrum matches.
- Open Access
- 29 June 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (27) , 40711-40717
Enhanced Genetically Variant Peptide Profiling from Human Hair Using Multiple Enzymes
- 29 June 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (27) , 40711-40717
Open AccessEnhanced Genetically Variant Peptide Profiling from Human Hair Using Multiple Enzymes
- Open Access
- 12 August 2025
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 36 (9) , 1970-1978
Unusual Fragmentations of Silylated Polyfluoroalkyl Compounds Induced by Electron Ionization
Per- and polyfluoroalkyl substances (PFAS) are environmentally persistent compounds that present analytical challenges due to their stability and low concentrations. In this study, electron ionization (EI) mass spectra of trimethylsilyl (TMS) derivatized fluorinated alcohols and carboxylic acids were examined to improve PFAS identification in the NIST Mass Spectral Reference Library. In contrast with the spectra of unsubstituted alcohol TMS compounds featuring losses of hydrocarbons, fluorinated alcohol TMS derivatives are characterized by the losses of fluorinated silyl groups. For example, a previously unreported [M-111]+ ion was consistently observed in compounds containing three methylene groups between the hydroxyl group and the first CF2 unit. Detailed quality assurance analysis using a suite of NIST software tools along with high-resolution TOF-MS confirmed the origin and elemental composition of these ions. MS2 experiments and full scan of TMS derivatives of fluorinated alcohols with varying numbers of methylene groups investigations suggest the formation of a five-membered ring intermediate as a key feature in this unique fragmentation pathway. These findings improve our understanding of PFAS fragmentation and support more accurate compound identification in analytical workflows.
- 12 August 2025
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 36 (9) , 1970-1978
Open AccessUnusual Fragmentations of Silylated Polyfluoroalkyl Compounds Induced by Electron Ionization
Per- and polyfluoroalkyl substances (PFAS) are environmentally persistent compounds that present analytical challenges due to their stability and low concentrations. In this study, electron ionization (EI) mass spectra of trimethylsilyl (TMS) derivatized fluorinated alcohols and carboxylic acids were examined to improve PFAS identification in the NIST Mass Spectral Reference Library. In contrast with the spectra of unsubstituted alcohol TMS compounds featuring losses of hydrocarbons, fluorinated alcohol TMS derivatives are characterized by the losses of fluorinated silyl groups. For example, a previously unreported [M-111]+ ion was consistently observed in compounds containing three methylene groups between the hydroxyl group and the first CF2 unit. Detailed quality assurance analysis using a suite of NIST software tools along with high-resolution TOF-MS confirmed the origin and elemental composition of these ions. MS2 experiments and full scan of TMS derivatives of fluorinated alcohols with varying numbers of methylene groups investigations suggest the formation of a five-membered ring intermediate as a key feature in this unique fragmentation pathway. These findings improve our understanding of PFAS fragmentation and support more accurate compound identification in analytical workflows.
- Open Access
- 14 January 2025
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 36 (2) , 389-399
New Library-Based Methods for Nontargeted Compound Identification by GC-EI-MS
While gas chromatography mass spectrometry (GC-MS) has long been used to identify compounds in complex mixtures, this process is often subjective and time-consuming and leaves a large fraction of seemingly good-quality spectra unidentified. In this work, we describe a set of new mass spectral library-based methods to assist compound identification in complex mixtures. These methods employ mass spectral uniqueness and compound ubiquity of library entries alongside noise reduction and automated comparison of retention indices to library compounds. As a test data set, we used a publicly available electron ionization mass spectrometry data set consisting of 4833 spectra of particulate organic compounds emitted by combustion of wildland fuels. In the present work, spectra in this data set were first identified using the NIST 2023 EI-MS Library and associated batch process identification software (NIST MS PepSearch) using retention-index corrected Identity Search scoring. Resulting identifications and related information were then employed to parametrize other factors that correlate with identification. A method for identifying compounds absent from but related to those present in mass spectral libraries using the Hybrid Similarity Search is illustrated. Nevertheless, some 90% of the spectra remain unidentified. Through comparison of unidentified to identified mass spectra in this data set, a new simple measure, namely median relative abundance, was developed for evaluating the likelihood of identification.
- 14 January 2025
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 36 (2) , 389-399
Open AccessNew Library-Based Methods for Nontargeted Compound Identification by GC-EI-MS
While gas chromatography mass spectrometry (GC-MS) has long been used to identify compounds in complex mixtures, this process is often subjective and time-consuming and leaves a large fraction of seemingly good-quality spectra unidentified. In this work, we describe a set of new mass spectral library-based methods to assist compound identification in complex mixtures. These methods employ mass spectral uniqueness and compound ubiquity of library entries alongside noise reduction and automated comparison of retention indices to library compounds. As a test data set, we used a publicly available electron ionization mass spectrometry data set consisting of 4833 spectra of particulate organic compounds emitted by combustion of wildland fuels. In the present work, spectra in this data set were first identified using the NIST 2023 EI-MS Library and associated batch process identification software (NIST MS PepSearch) using retention-index corrected Identity Search scoring. Resulting identifications and related information were then employed to parametrize other factors that correlate with identification. A method for identifying compounds absent from but related to those present in mass spectral libraries using the Hybrid Similarity Search is illustrated. Nevertheless, some 90% of the spectra remain unidentified. Through comparison of unidentified to identified mass spectra in this data set, a new simple measure, namely median relative abundance, was developed for evaluating the likelihood of identification.
- 3 January 2025
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 36 (2) , 439-445
NIST Mass Spectral Libraries in the Context of the Circular Economy of Plastics
The Mass Spectrometry Data Center (MSDC) has recently started improving existing libraries and creating new ones for identifying and analyzing plastics-related compounds (PRC) and materials (PRM) as part of the NIST circular economy program. PRC are small molecules of dissimilar chemical nature; hence, to increase coverage, we have used three types of ionizations: EI, ESI, and APCI. PRM are solids that include polymers, polymer mixtures, and commercial plastics, so we have used pyrolysis-gas chromatography (py-GC-MS) to create a new searchable library. First, we have increased the coverage of the existing libraries by including as many as possible commercially available PRC. Then, for testing the libraries and to deconvolute complex PRM mixtures, we have analyzed extractable and leachable (E&L) samples and pyrolysis products from one hundred standards of the most common polymers and some of their mixtures using LC-MS/MS, GC-MS, and py-GC-MS. In collaboration with the FDA, the EPA, and other non-government institutions, we are applying techniques, libraries, and tools to areas of interest to the circular economy of plastics, health risk assessments, and environmental challenges.
- 3 January 2025
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 36 (2) , 439-445
NIST Mass Spectral Libraries in the Context of the Circular Economy of Plastics
The Mass Spectrometry Data Center (MSDC) has recently started improving existing libraries and creating new ones for identifying and analyzing plastics-related compounds (PRC) and materials (PRM) as part of the NIST circular economy program. PRC are small molecules of dissimilar chemical nature; hence, to increase coverage, we have used three types of ionizations: EI, ESI, and APCI. PRM are solids that include polymers, polymer mixtures, and commercial plastics, so we have used pyrolysis-gas chromatography (py-GC-MS) to create a new searchable library. First, we have increased the coverage of the existing libraries by including as many as possible commercially available PRC. Then, for testing the libraries and to deconvolute complex PRM mixtures, we have analyzed extractable and leachable (E&L) samples and pyrolysis products from one hundred standards of the most common polymers and some of their mixtures using LC-MS/MS, GC-MS, and py-GC-MS. In collaboration with the FDA, the EPA, and other non-government institutions, we are applying techniques, libraries, and tools to areas of interest to the circular economy of plastics, health risk assessments, and environmental challenges.
- 22 November 2024
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 36 (1) , 85-90
Molecular Oxygen (O2) Artifacts in Tandem Mass Spectra
Peak annotation plays an important role in mass spectral evaluation of the NIST 2023 tandem mass spectral library. While most fragment ions are formed by neutral losses, there are peaks that represent adduct ions from these fragments. Previously, we have reported two main types of addition reactions in the collision cell, namely addition of H2O and N2. Here we report a different reaction in the collision cell, with addition of O2 leading to a small peak that could only be assigned to a peroxyl radical ion. For example, some protonated iodoaromatics lose an iodine atom to form a radical cation [M+H-I]+•, which reacts with O2 to generate a peroxyl radical ion [M+H-I+O2]+•. Higher concentrations of O2 result in higher peroxyl radical peaks, which become dominant while the precursor ions are consumed, as examined by five compounds under different concentrations of O2. The correlation of the peroxyl radical peak intensities to the concentration of O2 provides a tool to estimate trace amounts of O2 within the instrument. In the NIST 2023 tandem mass spectral library, the peaks for [M+H-X+O2]+· are most abundant in numbers and in intensity for X = NO2 or I, are much less abundant for X = Br, and are rare for X = Cl. Other leaving groups in this library are SO3H, SO2NH2, CSNH2, CO2C6F5, SO2CH3, and COCH3. The O2 addition reaction is also observed with negative ions in this library. While adducts of H2O and N2 often constitute major peaks, the peaks of the peroxyl radicals under standard conditions are mostly very small and may be mistaken for noise, but their correct annotation improves the quality of the spectra and is important when comparing spectra from different instruments or conditions.
- 22 November 2024
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 36 (1) , 85-90
Molecular Oxygen (O2) Artifacts in Tandem Mass Spectra
Peak annotation plays an important role in mass spectral evaluation of the NIST 2023 tandem mass spectral library. While most fragment ions are formed by neutral losses, there are peaks that represent adduct ions from these fragments. Previously, we have reported two main types of addition reactions in the collision cell, namely addition of H2O and N2. Here we report a different reaction in the collision cell, with addition of O2 leading to a small peak that could only be assigned to a peroxyl radical ion. For example, some protonated iodoaromatics lose an iodine atom to form a radical cation [M+H-I]+•, which reacts with O2 to generate a peroxyl radical ion [M+H-I+O2]+•. Higher concentrations of O2 result in higher peroxyl radical peaks, which become dominant while the precursor ions are consumed, as examined by five compounds under different concentrations of O2. The correlation of the peroxyl radical peak intensities to the concentration of O2 provides a tool to estimate trace amounts of O2 within the instrument. In the NIST 2023 tandem mass spectral library, the peaks for [M+H-X+O2]+· are most abundant in numbers and in intensity for X = NO2 or I, are much less abundant for X = Br, and are rare for X = Cl. Other leaving groups in this library are SO3H, SO2NH2, CSNH2, CO2C6F5, SO2CH3, and COCH3. The O2 addition reaction is also observed with negative ions in this library. While adducts of H2O and N2 often constitute major peaks, the peaks of the peroxyl radicals under standard conditions are mostly very small and may be mistaken for noise, but their correct annotation improves the quality of the spectra and is important when comparing spectra from different instruments or conditions.
- 10 April 2024
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 23 (5) , 1571-1582
An XIC-Centric Strategy for Improved Identification and Quantification in Proteomic Data Analyses
Reproducibility is a "proteomic dream" yet to be fully realized. A typical data analysis workflow utilizing extracted ion chromatograms (XICs) often treats the information path from identification to quantification as a one-way street. Here, we propose an XIC-centric approach in which the data flow is bidirectional: identifications are used to derive XICs whose information is in turn applied to validate the identifications. In this study, we employed liquid chromatography-mass spectrometry data from glycoprotein and human hair samples to illustrate the XIC-centric concept. At the core of this approach was XIC-based monoisotope repicking. Taking advantage of the intensity information for all detected isotopes across the whole range of an XIC peak significantly improved the accuracy and uncovered misidentifications originating from monoisotope assignment mistakes. It could also rescue non-top-ranked glycopeptide hits. Identification of glycopeptides is particularly susceptible to precursor mass errors for their low abundances, large masses, and glycans differing by 1 or 2 Da easily confused as isotopes. In addition, the XIC-centric strategy significantly reduced the problem of one XIC peak associated with multiple unique identifications, a source of quantitative irreproducibility. Taken together, the proposed approach can lead to improved identification and quantification accuracy and, ultimately, enhanced reproducibility in proteomic data analyses.
- 10 April 2024
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 23 (5) , 1571-1582
An XIC-Centric Strategy for Improved Identification and Quantification in Proteomic Data Analyses
Reproducibility is a "proteomic dream" yet to be fully realized. A typical data analysis workflow utilizing extracted ion chromatograms (XICs) often treats the information path from identification to quantification as a one-way street. Here, we propose an XIC-centric approach in which the data flow is bidirectional: identifications are used to derive XICs whose information is in turn applied to validate the identifications. In this study, we employed liquid chromatography-mass spectrometry data from glycoprotein and human hair samples to illustrate the XIC-centric concept. At the core of this approach was XIC-based monoisotope repicking. Taking advantage of the intensity information for all detected isotopes across the whole range of an XIC peak significantly improved the accuracy and uncovered misidentifications originating from monoisotope assignment mistakes. It could also rescue non-top-ranked glycopeptide hits. Identification of glycopeptides is particularly susceptible to precursor mass errors for their low abundances, large masses, and glycans differing by 1 or 2 Da easily confused as isotopes. In addition, the XIC-centric strategy significantly reduced the problem of one XIC peak associated with multiple unique identifications, a source of quantitative irreproducibility. Taken together, the proposed approach can lead to improved identification and quantification accuracy and, ultimately, enhanced reproducibility in proteomic data analyses.
- 7 March 2024
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 23 (4) , 1443-1457
Comparison of N-Glycopeptide to Released N-Glycan Abundances and the Influence of Glycopeptide Mass and Charge States on N-Linked Glycosylation of IgG Antibodies
We report the comparison of mass-spectral-based abundances of tryptic glycopeptides to fluorescence abundances of released labeled glycans and the effects of mass and charge state and in-source fragmentation on glycopeptide abundances. The primary glycoforms derived from Rituximab, NISTmAb, Evolocumab, and Infliximab were high-mannose and biantennary complex galactosylated and fucosylated N-glycans. Except for Evolocumab, in-source ions derived from the loss of HexNAc or HexNAc-Hex sugars are prominent for other therapeutic IgGs. After excluding in-source fragmentation of glycopeptide ions from the results, a linear correlation was observed between fluorescently labeled N-glycan and glycopeptide abundances over a dynamic range of 500. Different charge states of human IgG-derived glycopeptides containing a wider variety of abundant attached glycans were also investigated to examine the effects of the charge state on ion abundances. These revealed a linear dependence of glycopeptide abundance on the mass of the glycan with higher charge states favoring higher-mass glycans. Findings indicate that the mass spectrometry-based bottom-up approach can provide results as accurate as those of glycan release studies while revealing the origin of each attached glycan. These site-specific relative abundances are conveniently displayed and compared using previously described glycopeptide abundance distribution spectra "GADS" representations. Mass spectrometry data are available from the MAssIVE repository (MSV000093562).
- 7 March 2024
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 23 (4) , 1443-1457
Comparison of N-Glycopeptide to Released N-Glycan Abundances and the Influence of Glycopeptide Mass and Charge States on N-Linked Glycosylation of IgG Antibodies
We report the comparison of mass-spectral-based abundances of tryptic glycopeptides to fluorescence abundances of released labeled glycans and the effects of mass and charge state and in-source fragmentation on glycopeptide abundances. The primary glycoforms derived from Rituximab, NISTmAb, Evolocumab, and Infliximab were high-mannose and biantennary complex galactosylated and fucosylated N-glycans. Except for Evolocumab, in-source ions derived from the loss of HexNAc or HexNAc-Hex sugars are prominent for other therapeutic IgGs. After excluding in-source fragmentation of glycopeptide ions from the results, a linear correlation was observed between fluorescently labeled N-glycan and glycopeptide abundances over a dynamic range of 500. Different charge states of human IgG-derived glycopeptides containing a wider variety of abundant attached glycans were also investigated to examine the effects of the charge state on ion abundances. These revealed a linear dependence of glycopeptide abundance on the mass of the glycan with higher charge states favoring higher-mass glycans. Findings indicate that the mass spectrometry-based bottom-up approach can provide results as accurate as those of glycan release studies while revealing the origin of each attached glycan. These site-specific relative abundances are conveniently displayed and compared using previously described glycopeptide abundance distribution spectra "GADS" representations. Mass spectrometry data are available from the MAssIVE repository (MSV000093562).