Qiuyang Tan
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Qiuyang Tan has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Baoyu Zhang
1 shared publicationE. M. Sankara Narayanan
Department of Electronics and Electrical Engineering University of Sheffield Sheffield UK
1 shared publication- Gopika Narayanankutty
Department of Electronics and Electrical Engineering University of Sheffield Sheffield UK
1 shared publication Hongyao Liu
UniSiC Technology (Shanghai) Company, Ltd., Shanghai, China
1 shared publication- Jiajie Fan
Fudan University
1 shared publication - Ke Yu
Affiliated Hospital of Southwest Medical University 646000 Luzhou China
1 shared publication
Latest Publications
- 10 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (9) , 10950-10961
Analysis and Modeling of Zero-Voltage-Switching Condition for $LCC$ Resonant Converter in Above-Resonance Operation ModeThe $LCC$ resonant converter in the above-resonance operation mode is gaining popularity in high-voltage generator applications due to its favorable characteristics, including zero-voltage switching (ZVS), step-up capability, and the absorption of parasitics. Nevertheless, with the increase of the voltage gain $G_{o}$ of the resonant tank, the ZVS condition is undermined for the $LCC$ resonant converter. This study aims to characterize the ZVS condition of the $LCC$ resonant converter in the above-resonance operation mode. For this purpose, a two-step-based ZVS analysis is carried out, incorporating the partial steady-state analysis and the dead-time analysis. The outcome of this analysis is the derivation of a set of three necessary conditions that define a sufficient ZVS condition model of the $LCC$ resonant converter in the above-resonance operation mode. According to the analytical dead-time analysis, a discriminator $\Delta$ representing the ZVS performance of the $LCC$ resonant converter is demonstrated, and the ZVS condition can only be achieved when $\Delta$ $>$ 0. Moreover, the analysis of the sign of $\Delta$ reveals that the $LCC$ resonant converter exhibits a weaker ZVS condition when $G_{o} >$ 1 than when $G_{o}$ $\leq$ 1. On the basis of the proposed ZVS condition model, a design method is proposed to illustrate the influence of the ZVS condition on the output of the step-up $LCC$ resonant converter. Finally, experimental results obtained from a prototype of a 1053-V 222-W output $LCC$ resonant converter are included to validate the accuracy of the theoretical analysis.
- 10 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (9) , 10950-10961
Analysis and Modeling of Zero-Voltage-Switching Condition for $LCC$ Resonant Converter in Above-Resonance Operation ModeThe $LCC$ resonant converter in the above-resonance operation mode is gaining popularity in high-voltage generator applications due to its favorable characteristics, including zero-voltage switching (ZVS), step-up capability, and the absorption of parasitics. Nevertheless, with the increase of the voltage gain $G_{o}$ of the resonant tank, the ZVS condition is undermined for the $LCC$ resonant converter. This study aims to characterize the ZVS condition of the $LCC$ resonant converter in the above-resonance operation mode. For this purpose, a two-step-based ZVS analysis is carried out, incorporating the partial steady-state analysis and the dead-time analysis. The outcome of this analysis is the derivation of a set of three necessary conditions that define a sufficient ZVS condition model of the $LCC$ resonant converter in the above-resonance operation mode. According to the analytical dead-time analysis, a discriminator $\Delta$ representing the ZVS performance of the $LCC$ resonant converter is demonstrated, and the ZVS condition can only be achieved when $\Delta$ $>$ 0. Moreover, the analysis of the sign of $\Delta$ reveals that the $LCC$ resonant converter exhibits a weaker ZVS condition when $G_{o} >$ 1 than when $G_{o}$ $\leq$ 1. On the basis of the proposed ZVS condition model, a design method is proposed to illustrate the influence of the ZVS condition on the output of the step-up $LCC$ resonant converter. Finally, experimental results obtained from a prototype of a 1053-V 222-W output $LCC$ resonant converter are included to validate the accuracy of the theoretical analysis.
- Open Access
- 1 January 2023
- Published by Clausius Scientific Press, Inc. in Advances in Vocational and Technical Education
- Vol. 5 (8) , 93-98
Analysis and Reflection on the Present Status of Evaluation Competency for Teaching Faculty of the Standardized Residency Training in General Practice under the Background of New Medical Education
The evaluation competency of teaching faculty in standardized residency training for general practice is a dynamic intelligence based on educational reform, paradigm shift of evaluation, and the professional development needs of teachers in the context of new medical education. This study aims to analyze the present status of evaluation competency for these teaching faculty, including their knowledge, skills, ideas, and consciousness, as well as their internal cultivation and quality. Through a clinical teaching evaluation practice of standardized training for general practice residents, the study explores the value, expected performance, and empirical analysis of developing teacher evaluation competency. The research draws on domestic and foreign research experiences, and proposes a path for promoting the development of evaluation competency for teaching faculty in this field to improve the quality of residency training in general practice.
- 1 January 2023
- Published by Clausius Scientific Press, Inc. in Advances in Vocational and Technical Education
- Vol. 5 (8) , 93-98
Open AccessAnalysis and Reflection on the Present Status of Evaluation Competency for Teaching Faculty of the Standardized Residency Training in General Practice under the Background of New Medical Education
The evaluation competency of teaching faculty in standardized residency training for general practice is a dynamic intelligence based on educational reform, paradigm shift of evaluation, and the professional development needs of teachers in the context of new medical education. This study aims to analyze the present status of evaluation competency for these teaching faculty, including their knowledge, skills, ideas, and consciousness, as well as their internal cultivation and quality. Through a clinical teaching evaluation practice of standardized training for general practice residents, the study explores the value, expected performance, and empirical analysis of developing teacher evaluation competency. The research draws on domestic and foreign research experiences, and proposes a path for promoting the development of evaluation competency for teaching faculty in this field to improve the quality of residency training in general practice.
- Open Access
- 16 November 2022
- Published by Elsevier in Energy Reports
- Vol. 9, 568-576
Comparative evaluation and analysis of GaN-based VSIs and CSIs
- 16 November 2022
- Published by Elsevier in Energy Reports
- Vol. 9, 568-576
Open AccessComparative evaluation and analysis of GaN-based VSIs and CSIs
- Open Access
- 1 August 2021
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 14 (14) , 2305-2313
An ultra‐fast protection scheme for normally‐on wide bandgap devices
Here, an ultra‐fast protection scheme that is dedicated to depletion‐mode (d‐mode) devices is proposed. The key to the d‐mode device gate drive design is the negative supply and overcurrent protection, due to the safety concern for d‐mode devices when a failure happens in power conversion applications. This work evaluates specific requirement of d‐mode devices, such as the isolated negative power supply and short‐circuit protection. Normally‐on d‐mode GaN devices have lower on‐resistance and minimal dead time in comparison with enhancement‐mode (e‐mode) GaN devices, which can further reduce the switching loss and conduction loss. Both simulation and experimental verification are conducted in this work to evaluate the performance of the proposed protection scheme. The proposed desaturation scheme can wipe out the overcurrent event within 341 ns. Furthermore, the proposed negative power supply scheme can sustain its output for 60.5 ms, providing sufficient action time for the control unit to isolate the converter.
- 1 August 2021
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 14 (14) , 2305-2313
Open AccessAn ultra‐fast protection scheme for normally‐on wide bandgap devices
Here, an ultra‐fast protection scheme that is dedicated to depletion‐mode (d‐mode) devices is proposed. The key to the d‐mode device gate drive design is the negative supply and overcurrent protection, due to the safety concern for d‐mode devices when a failure happens in power conversion applications. This work evaluates specific requirement of d‐mode devices, such as the isolated negative power supply and short‐circuit protection. Normally‐on d‐mode GaN devices have lower on‐resistance and minimal dead time in comparison with enhancement‐mode (e‐mode) GaN devices, which can further reduce the switching loss and conduction loss. Both simulation and experimental verification are conducted in this work to evaluate the performance of the proposed protection scheme. The proposed desaturation scheme can wipe out the overcurrent event within 341 ns. Furthermore, the proposed negative power supply scheme can sustain its output for 60.5 ms, providing sufficient action time for the control unit to isolate the converter.