Ece Ates
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ece Ates has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Burak Kocak
Department of Radiology, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey
9 shared publications Emine Sebnem Durmaz
Department of Radiology, Buyukcekmece Mimar Sinan State Hospital, Istanbul, Turkey
6 shared publicationsOzgur Kilickesmez
Department of Radiology, Istanbul Training and Research Hospital, Samatya, Istanbul 34098, Turkey
5 shared publicationsOzlem Korkmaz Kaya
Department of Radiology, Koc University School of Medicine, Koc University Hospital, Istanbul, Turkey
3 shared publications- Abdullah Soydan Mahmutoğlu
Department of Radiology, Istanbul Training and Research Hospital, Istanbul, Turkey
2 shared publications Melis Baykara Ulusan
Department of Radiology, Istanbul Training and Research Hospital, Istanbul, Turkey
2 shared publications
Latest Publications
- Open Access
- 8 April 2026
- Published by Bentham Science Publishers Ltd. in Current Medical Imaging
- Vol. 22, 1-13
Differentiation of Fat-poor and Atypical Adrenal Adenomas from Metastases: MRI-based Radiomic, Radiologic, and Radiomic-radiologic Machine Learning Models
Introduction: The accurate differentiation of fat-poor and atypical adrenal adenomas from metastases remains a diagnostic challenge. This study aimed to evaluate the predictive value of MRI-based radiomic, radiologic, and combined radiomic-radiologic machine learning (ML) models. Methods: This single-center retrospective study included 37 patients with 44 adrenal masses (19 adenomas; 25 metastases). Data were split into training and testing sets (2:1). To expand the training set, data augmentation was performed by multiple sampling (56 labeled slices from 30 masses). Radiomic features were extracted from T2-weighted (T2W), in-phase, out-of-phase, and apparent diffusion coefficient (ADC) sequences, while mass size, T2W signal intensity, heterogeneity, and signal drop were assessed as radiologic features. Dimension reduction was performed by reliability analysis and wrapper-based feature selection with five algorithms. A support vector machine was used for classification, and performance was assessed using 10-fold cross-validation and unseen testing. Friedman test and post-hoc analyses compared bootstrapped unseen test AUCs. Results: Only 12% of radiomic features demonstrated excellent reproducibility. A significant difference was observed among the three models, χ2(2)=779.5, p<0.001. The combined radiomic-radiologic model achieved the best performance (AUC 0.939; accuracy 85.7%), outperforming radiomic-only (AUC 0.898; accuracy 85.7%) and radiologic-only (AUC 0.857; accuracy 78.5%) models (adjusted p<0.001). Discussion: Integrating radiomic and radiologic features improved classification performance compared to using either feature set alone. Although the reproducibility of radiomic features was limited, their complementary value enhanced model robustness. Conclusion: A combined radiomic-radiologic ML model based on multi-sequence MRI may serve as a promising non-invasive tool for differentiating atypical adrenal adenomas from metastases.
- 8 April 2026
- Published by Bentham Science Publishers Ltd. in Current Medical Imaging
- Vol. 22, 1-13
Open AccessDifferentiation of Fat-poor and Atypical Adrenal Adenomas from Metastases: MRI-based Radiomic, Radiologic, and Radiomic-radiologic Machine Learning Models
Introduction: The accurate differentiation of fat-poor and atypical adrenal adenomas from metastases remains a diagnostic challenge. This study aimed to evaluate the predictive value of MRI-based radiomic, radiologic, and combined radiomic-radiologic machine learning (ML) models. Methods: This single-center retrospective study included 37 patients with 44 adrenal masses (19 adenomas; 25 metastases). Data were split into training and testing sets (2:1). To expand the training set, data augmentation was performed by multiple sampling (56 labeled slices from 30 masses). Radiomic features were extracted from T2-weighted (T2W), in-phase, out-of-phase, and apparent diffusion coefficient (ADC) sequences, while mass size, T2W signal intensity, heterogeneity, and signal drop were assessed as radiologic features. Dimension reduction was performed by reliability analysis and wrapper-based feature selection with five algorithms. A support vector machine was used for classification, and performance was assessed using 10-fold cross-validation and unseen testing. Friedman test and post-hoc analyses compared bootstrapped unseen test AUCs. Results: Only 12% of radiomic features demonstrated excellent reproducibility. A significant difference was observed among the three models, χ2(2)=779.5, p<0.001. The combined radiomic-radiologic model achieved the best performance (AUC 0.939; accuracy 85.7%), outperforming radiomic-only (AUC 0.898; accuracy 85.7%) and radiologic-only (AUC 0.857; accuracy 78.5%) models (adjusted p<0.001). Discussion: Integrating radiomic and radiologic features improved classification performance compared to using either feature set alone. Although the reproducibility of radiomic features was limited, their complementary value enhanced model robustness. Conclusion: A combined radiomic-radiologic ML model based on multi-sequence MRI may serve as a promising non-invasive tool for differentiating atypical adrenal adenomas from metastases.
- 18 July 2025
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 50 (1) , 160-165
Radiomics-Based Preoperative Contrast Enhanced CT Histogram Analysis and Shape Feature Extraction in Laryngeal Squamous Cell Carcinoma: Correlation with Histopathological Parameters
Aim: This study aims to investigate whether preoperative contrast-enhanced laryngeal CT-derived histogram parameters and shape features can correlate with cervical lymph node metastasis, tumor differentiation (grade), lymphovascular invasion, and perineural invasion in laryngeal squamous cell carcinoma (LSCC). Materials and Methods: Ninety-one patients who underwent laryngectomy and simultaneous cervical lymph node dissection at our hospital between 2015 and 2021, with LSCC as the final pathological outcome, were included. Two radiologists independently performed segmentation using 3D Slicer Software, drawing regions of interest (ROIs) from the widest axial section of each tumor and volumes of interest (VOIs) to cover the entire visualizable tumor. Histogram parameters and shape features were extracted for each segmentation. Cut-off values were calculated, and intraclass correlation was used to measure interobserver agreement. Results: ROI measurements showed significant differences only for lymphovascular invasion. VOI measurements revealed significant differences between lymphovascular and perineural invasion and cervical lymph node metastasis. Key parameters included entropy, mean absolute deviation, and uniformity. No significant differences were found for tumor grade. VOI-based measurements outperformed ROI-based measurements in terms of reproducibility and diagnostic breadth, showing higher intraclass correlation values and more significant associations with pathological features. Conclusion: Preoperative contrast-enhanced CT histogram parameters and shape features may be useful in evaluating tumor characteristics in LSCC. Export
- 18 July 2025
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 50 (1) , 160-165
Radiomics-Based Preoperative Contrast Enhanced CT Histogram Analysis and Shape Feature Extraction in Laryngeal Squamous Cell Carcinoma: Correlation with Histopathological Parameters
Aim: This study aims to investigate whether preoperative contrast-enhanced laryngeal CT-derived histogram parameters and shape features can correlate with cervical lymph node metastasis, tumor differentiation (grade), lymphovascular invasion, and perineural invasion in laryngeal squamous cell carcinoma (LSCC). Materials and Methods: Ninety-one patients who underwent laryngectomy and simultaneous cervical lymph node dissection at our hospital between 2015 and 2021, with LSCC as the final pathological outcome, were included. Two radiologists independently performed segmentation using 3D Slicer Software, drawing regions of interest (ROIs) from the widest axial section of each tumor and volumes of interest (VOIs) to cover the entire visualizable tumor. Histogram parameters and shape features were extracted for each segmentation. Cut-off values were calculated, and intraclass correlation was used to measure interobserver agreement. Results: ROI measurements showed significant differences only for lymphovascular invasion. VOI measurements revealed significant differences between lymphovascular and perineural invasion and cervical lymph node metastasis. Key parameters included entropy, mean absolute deviation, and uniformity. No significant differences were found for tumor grade. VOI-based measurements outperformed ROI-based measurements in terms of reproducibility and diagnostic breadth, showing higher intraclass correlation values and more significant associations with pathological features. Conclusion: Preoperative contrast-enhanced CT histogram parameters and shape features may be useful in evaluating tumor characteristics in LSCC. Export
- 1 June 2025
- Published by ASEAN Neurological Association in Neurology Asia
- Vol. 30 (2) , 419-426
Evaluation of the thalamus volume and cortical thickness in patients with epilepsy and determining the relationship of these measurements with the clinical variables of the disease
Background & Objectives: The influence of cortical firing neurons and subcortical structures, especially thalamic networks, has a role in the formation and continuity of epileptic seizure activities. In our study, bilateral thalamus volume and cortex thickness from different regions (frontal, temporal, parietal, occipital) were measured in brain magnetic resonance imaging (MRI) of patients diagnosed with epilepsy (PWE)and compared with the healthy control (HC) group. The relationship between the obtained findings and clinical variables of PWEs is intended to be evaluated. Methods: Our study was designed as a retrospective cross-sectional study. Between January 2018 and December 2020, 62 PWE were diagnosed by specialist physicians in the neurology outpatient clinic, and 42HC groups were included in the study. Thalamus volume and cortical thickness of frontal, parietal, temporal, and occipital regions were measured by an experienced neuroradiologist and neurologist using a 1.5TMRI device from the 3-DT1sequence of brain MRI examinations of all participants. The measurements of MRI metrics in PWE and HC groups were compared. Results: The mean age of the PWE were35.7±12.162, and the mean age of the HC was35.7±11.0. The two groups were similar in age (p=0.842) and gender (p=0.812) distribution. Bilateral thalamus volumes (p<0.001) and cortical thickness (p<0.001) of PWE were found to be lower compared to the HC group. As the disease duration of PWE increased, there was a significant decrease in bilateral thalamus volüme (p<0.001) and temporal cortical thickness (p<0.001). In the group with high seizure frequency, there was a significant decrease in bilateral thalamus volüme (p<0.001) and a significant reduction in temporal cortical thickness (right temporal p=0.040; left temporal p=0.013). As MRImetrics were compared according to seizure type in the PWE group, right frontal cortex (p=0.043), bilateral parietal cortex (p=0.033, p=0.022), left occipital cortex thickness (p=0.031) were found to be lower in patients with focal seizures compared to patients with generalised seizures. Conclusions: In this study, bilateral thalamus volume and cortical thickness were significantly lower in PWE than in the HC group.
- 1 June 2025
- Published by ASEAN Neurological Association in Neurology Asia
- Vol. 30 (2) , 419-426
Evaluation of the thalamus volume and cortical thickness in patients with epilepsy and determining the relationship of these measurements with the clinical variables of the disease
Background & Objectives: The influence of cortical firing neurons and subcortical structures, especially thalamic networks, has a role in the formation and continuity of epileptic seizure activities. In our study, bilateral thalamus volume and cortex thickness from different regions (frontal, temporal, parietal, occipital) were measured in brain magnetic resonance imaging (MRI) of patients diagnosed with epilepsy (PWE)and compared with the healthy control (HC) group. The relationship between the obtained findings and clinical variables of PWEs is intended to be evaluated. Methods: Our study was designed as a retrospective cross-sectional study. Between January 2018 and December 2020, 62 PWE were diagnosed by specialist physicians in the neurology outpatient clinic, and 42HC groups were included in the study. Thalamus volume and cortical thickness of frontal, parietal, temporal, and occipital regions were measured by an experienced neuroradiologist and neurologist using a 1.5TMRI device from the 3-DT1sequence of brain MRI examinations of all participants. The measurements of MRI metrics in PWE and HC groups were compared. Results: The mean age of the PWE were35.7±12.162, and the mean age of the HC was35.7±11.0. The two groups were similar in age (p=0.842) and gender (p=0.812) distribution. Bilateral thalamus volumes (p<0.001) and cortical thickness (p<0.001) of PWE were found to be lower compared to the HC group. As the disease duration of PWE increased, there was a significant decrease in bilateral thalamus volüme (p<0.001) and temporal cortical thickness (p<0.001). In the group with high seizure frequency, there was a significant decrease in bilateral thalamus volüme (p<0.001) and a significant reduction in temporal cortical thickness (right temporal p=0.040; left temporal p=0.013). As MRImetrics were compared according to seizure type in the PWE group, right frontal cortex (p=0.043), bilateral parietal cortex (p=0.033, p=0.022), left occipital cortex thickness (p=0.031) were found to be lower in patients with focal seizures compared to patients with generalised seizures. Conclusions: In this study, bilateral thalamus volume and cortical thickness were significantly lower in PWE than in the HC group.
- Open Access
- 12 February 2025
- Published by Springer Nature in European Radiology
- Vol. 35 (8) , 4490-4505
Radiomics for differentiating radiation-induced brain injury from recurrence in gliomas: systematic review, meta-analysis, and methodological quality evaluation using METRICS and RQS
Objective: To systematically evaluate glioma radiomics literature on differentiating between radiation-induced brain injury and tumor recurrence. Methods: Literature was searched on PubMed and Web of Science (end date: May 7, 2024). Quality of eligible papers was assessed using METhodological RadiomICs Score (METRICS) and Radiomics Quality Score (RQS). Reliability of quality scoring tools were analyzed. Meta-analysis, meta-regression, and subgroup analysis were performed. Results: Twenty-seven papers were included in the qualitative assessment. Mean average METRICS score and RQS percentage score across three readers was 57% (SD, 14%) and 16% (SD, 12%), respectively. Score-wise inter-rater agreement for METRICS ranged from poor to excellent, while RQS demonstrated moderate to excellent agreement. Item-wise agreement was moderate for both tools. Meta-analysis of 11 eligible studies yielded an estimated area under the receiver operating characteristic curve of 0.832 (95% CI, 0.757–0.908), with significant heterogeneity (I 2 = 91%) and no statistical publication bias (p = 0.051). Meta-regression did not identify potential sources of heterogeneity. Subgroup analysis revealed high heterogeneity across all subgroups, with the lowest I 2 at 68% in studies with proper validation and higher quality scores. Statistical publication bias was generally not significant, except in the subgroup with the lowest heterogeneity (p = 0.044). However, most studies in both qualitative analysis (26/27; 96%) and primary meta-analysis (10/11; 91%) reported positive effects of radiomics, indicating high non-statistical publication bias. Conclusion: While a good performance was noted for radiomics, results should be interpreted cautiously due to heterogeneity, publication bias, and quality issues thoroughly examined in this study. Key Points: Question Radiomic literature on distinguishing radiation-induced brain injury from glioma recurrence lacks systematic reviews and meta-analyses that assess methodological quality using radiomics-specific tools. Findings While the results are encouraging, there was substantial heterogeneity, publication bias toward positive findings, and notable concerns regarding methodological quality. Clinical relevance Meta-analysis results need cautious interpretation due to significant problems detected during the analysis (e.g., suboptimal quality, heterogeneity, bias), which may help explain why radiomics has not yet been translated into clinical practice. Graphical
- 12 February 2025
- Published by Springer Nature in European Radiology
- Vol. 35 (8) , 4490-4505
Open AccessRadiomics for differentiating radiation-induced brain injury from recurrence in gliomas: systematic review, meta-analysis, and methodological quality evaluation using METRICS and RQS
Objective: To systematically evaluate glioma radiomics literature on differentiating between radiation-induced brain injury and tumor recurrence. Methods: Literature was searched on PubMed and Web of Science (end date: May 7, 2024). Quality of eligible papers was assessed using METhodological RadiomICs Score (METRICS) and Radiomics Quality Score (RQS). Reliability of quality scoring tools were analyzed. Meta-analysis, meta-regression, and subgroup analysis were performed. Results: Twenty-seven papers were included in the qualitative assessment. Mean average METRICS score and RQS percentage score across three readers was 57% (SD, 14%) and 16% (SD, 12%), respectively. Score-wise inter-rater agreement for METRICS ranged from poor to excellent, while RQS demonstrated moderate to excellent agreement. Item-wise agreement was moderate for both tools. Meta-analysis of 11 eligible studies yielded an estimated area under the receiver operating characteristic curve of 0.832 (95% CI, 0.757–0.908), with significant heterogeneity (I 2 = 91%) and no statistical publication bias (p = 0.051). Meta-regression did not identify potential sources of heterogeneity. Subgroup analysis revealed high heterogeneity across all subgroups, with the lowest I 2 at 68% in studies with proper validation and higher quality scores. Statistical publication bias was generally not significant, except in the subgroup with the lowest heterogeneity (p = 0.044). However, most studies in both qualitative analysis (26/27; 96%) and primary meta-analysis (10/11; 91%) reported positive effects of radiomics, indicating high non-statistical publication bias. Conclusion: While a good performance was noted for radiomics, results should be interpreted cautiously due to heterogeneity, publication bias, and quality issues thoroughly examined in this study. Key Points: Question Radiomic literature on distinguishing radiation-induced brain injury from glioma recurrence lacks systematic reviews and meta-analyses that assess methodological quality using radiomics-specific tools. Findings While the results are encouraging, there was substantial heterogeneity, publication bias toward positive findings, and notable concerns regarding methodological quality. Clinical relevance Meta-analysis results need cautious interpretation due to significant problems detected during the analysis (e.g., suboptimal quality, heterogeneity, bias), which may help explain why radiomics has not yet been translated into clinical practice. Graphical
- 5 January 2024
- Published by Springer Nature in European Radiology
- Vol. 34 (8) , 5028-5040
Self-reported checklists and quality scoring tools in radiomics: a meta-research
Objective To evaluate the use of reporting checklists and quality scoring tools for self-reporting purposes in radiomics literature. Methods Literature search was conducted in PubMed (date, April 23, 2023). The radiomics literature was sampled at random after a sample size calculation with a priori power analysis. A systematic assessment for self-reporting, including the use of documentation such as completed checklists or quality scoring tools, was conducted in original research papers. These eligible papers underwent independent evaluation by a panel of nine readers, with three readers assigned to each paper. Automatic annotation was used to assist in this process. Then, a detailed item-by-item confirmation analysis was carried out on papers with checklist documentation, with independent evaluation of two readers. Results The sample size calculation yielded 117 papers. Most of the included papers were retrospective (94%; 110/117), single-center (68%; 80/117), based on their private data (89%; 104/117), and lacked external validation (79%; 93/117). Only seven papers (6%) had at least one self-reported document (Radiomics Quality Score (RQS), Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis (TRIPOD), or Checklist for Artificial Intelligence in Medical Imaging (CLAIM)), with a statistically significant binomial test (p < 0.001). Median rate of confirmed items for all three documents was 81% (interquartile range, 6). For quality scoring tools, documented scores were higher than suggested scores, with a mean difference of − 7.2 (standard deviation, 6.8). Conclusion Radiomic publications often lack self-reported checklists or quality scoring tools. Even when such documents are provided, it is essential to be cautious, as the accuracy of the reported items or scores may be questionable. Clinical relevance statement Current state of radiomic literature reveals a notable absence of self-reporting with documentation and inaccurate reporting practices. This critical observation may serve as a catalyst for motivating the radiomics community to adopt and utilize such tools appropriately, thereby fostering rigor, transparency, and reproducibility of their research, moving the field forward. Key Points • In radiomics literature, there has been a notable absence of self-reporting with documentation. • Even if such documents are provided, it is critical to exercise caution because the accuracy of the reported items or scores may be questionable. • Radiomics community needs to be motivated to adopt and appropriately utilize the reporting checklists and quality scoring tools. Graphical Abstract
- 5 January 2024
- Published by Springer Nature in European Radiology
- Vol. 34 (8) , 5028-5040
Self-reported checklists and quality scoring tools in radiomics: a meta-research
Objective To evaluate the use of reporting checklists and quality scoring tools for self-reporting purposes in radiomics literature. Methods Literature search was conducted in PubMed (date, April 23, 2023). The radiomics literature was sampled at random after a sample size calculation with a priori power analysis. A systematic assessment for self-reporting, including the use of documentation such as completed checklists or quality scoring tools, was conducted in original research papers. These eligible papers underwent independent evaluation by a panel of nine readers, with three readers assigned to each paper. Automatic annotation was used to assist in this process. Then, a detailed item-by-item confirmation analysis was carried out on papers with checklist documentation, with independent evaluation of two readers. Results The sample size calculation yielded 117 papers. Most of the included papers were retrospective (94%; 110/117), single-center (68%; 80/117), based on their private data (89%; 104/117), and lacked external validation (79%; 93/117). Only seven papers (6%) had at least one self-reported document (Radiomics Quality Score (RQS), Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis (TRIPOD), or Checklist for Artificial Intelligence in Medical Imaging (CLAIM)), with a statistically significant binomial test (p < 0.001). Median rate of confirmed items for all three documents was 81% (interquartile range, 6). For quality scoring tools, documented scores were higher than suggested scores, with a mean difference of − 7.2 (standard deviation, 6.8). Conclusion Radiomic publications often lack self-reported checklists or quality scoring tools. Even when such documents are provided, it is essential to be cautious, as the accuracy of the reported items or scores may be questionable. Clinical relevance statement Current state of radiomic literature reveals a notable absence of self-reporting with documentation and inaccurate reporting practices. This critical observation may serve as a catalyst for motivating the radiomics community to adopt and utilize such tools appropriately, thereby fostering rigor, transparency, and reproducibility of their research, moving the field forward. Key Points • In radiomics literature, there has been a notable absence of self-reporting with documentation. • Even if such documents are provided, it is critical to exercise caution because the accuracy of the reported items or scores may be questionable. • Radiomics community needs to be motivated to adopt and appropriately utilize the reporting checklists and quality scoring tools. Graphical Abstract
- 4 August 2021
- Published by Galenos Yayinevi in Istanbul Medical Journal
- Vol. 22 (3) , 223-231
Machine Learning-Based Computed Tomography Texture Analysis of Lytic Bone Lesions Needing Biopsy: A Preliminary Study
- 4 August 2021
- Published by Galenos Yayinevi in Istanbul Medical Journal
- Vol. 22 (3) , 223-231
Machine Learning-Based Computed Tomography Texture Analysis of Lytic Bone Lesions Needing Biopsy: A Preliminary Study
- 1 January 2020
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 214 (1) , 129-136
Radiomics of Renal Masses: Systematic Review of Reproducibility and Validation Strategies
OBJECTIVE. The purpose of this study was to systematically review the radiomics literature on renal mass characterization in terms of reproducibility and validation strategies. MATERIALS AND METHOD...
- 1 January 2020
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 214 (1) , 129-136
Radiomics of Renal Masses: Systematic Review of Reproducibility and Validation Strategies
OBJECTIVE. The purpose of this study was to systematically review the radiomics literature on renal mass characterization in terms of reproducibility and validation strategies. MATERIALS AND METHOD...
- Top Cited Papers
- 5 November 2019
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 25 (6) , 485-495
Radiomics with artificial intelligence: a practical guide for beginners
Dir Journal Diagnostic and Interventional Radiology
- 5 November 2019
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 25 (6) , 485-495
Top Cited PapersRadiomics with artificial intelligence: a practical guide for beginners
Dir Journal Diagnostic and Interventional Radiology
- 1 August 2019
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 213 (2) , 377-383
Reliability of Single-Slice–Based 2D CT Texture Analysis of Renal Masses: Influence of Intra- and Interobserver Manual Segmentation Variability on Radiomic Feature Reproducibility
OBJECTIVE. The objective of our study was to investigate the potential influence of intra- and interobserver manual segmentation variability on the reliability of single-slice–based 2D CT texture analysis of renal masses. MATERIALS AND METHODS. For this retrospective study, 30 patients with clear cell renal cell carcinoma were included from a public database. For intra- and interobserver analyses, three radiologists with varying degrees of experience segmented the tumors from unenhanced CT and corticomedullary phase contrast-enhanced CT (CECT) in different sessions. Each radiologist was blind to the image slices selected by other radiologists and him- or herself in the previous session. A total of 744 texture features were extracted from original, filtered, and transformed images. The intraclass correlation coefficient was used for reliability analysis. RESULTS. In the intraobserver analysis, the rates of features with good to excellent reliability were 84.4–92.2% for unenhanced CT and 85.5–93.1% for CECT. Considering the mean rates of unenhanced CT and CECT, having high experience resulted in better reliability rates in terms of the intraobserver analysis. In the interobserver analysis, the rates were 76.7% for unenhanced CT and 84.9% for CECT. The gray-level cooccurrence matrix and first-order feature groups yielded higher good to excellent reliability rates on both unenhanced CT and CECT. Filtered and transformed images resulted in more features with good to excellent reliability than the original images did on both unenhanced CT and CECT. CONCLUSION. Single-slice–based 2D CT texture analysis of renal masses is sensitive to intra- and interobserver manual segmentation variability. Therefore, it may lead to nonreproducible results in radiomic analysis unless a reliability analysis is considered in the workflow.
- 1 August 2019
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 213 (2) , 377-383
Reliability of Single-Slice–Based 2D CT Texture Analysis of Renal Masses: Influence of Intra- and Interobserver Manual Segmentation Variability on Radiomic Feature Reproducibility
OBJECTIVE. The objective of our study was to investigate the potential influence of intra- and interobserver manual segmentation variability on the reliability of single-slice–based 2D CT texture analysis of renal masses. MATERIALS AND METHODS. For this retrospective study, 30 patients with clear cell renal cell carcinoma were included from a public database. For intra- and interobserver analyses, three radiologists with varying degrees of experience segmented the tumors from unenhanced CT and corticomedullary phase contrast-enhanced CT (CECT) in different sessions. Each radiologist was blind to the image slices selected by other radiologists and him- or herself in the previous session. A total of 744 texture features were extracted from original, filtered, and transformed images. The intraclass correlation coefficient was used for reliability analysis. RESULTS. In the intraobserver analysis, the rates of features with good to excellent reliability were 84.4–92.2% for unenhanced CT and 85.5–93.1% for CECT. Considering the mean rates of unenhanced CT and CECT, having high experience resulted in better reliability rates in terms of the intraobserver analysis. In the interobserver analysis, the rates were 76.7% for unenhanced CT and 84.9% for CECT. The gray-level cooccurrence matrix and first-order feature groups yielded higher good to excellent reliability rates on both unenhanced CT and CECT. Filtered and transformed images resulted in more features with good to excellent reliability than the original images did on both unenhanced CT and CECT. CONCLUSION. Single-slice–based 2D CT texture analysis of renal masses is sensitive to intra- and interobserver manual segmentation variability. Therefore, it may lead to nonreproducible results in radiomic analysis unless a reliability analysis is considered in the workflow.
- 1 June 2019
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 212 (6) , W132-W139
Unenhanced CT Texture Analysis of Clear Cell Renal Cell Carcinomas: A Machine Learning–Based Study for Predicting Histopathologic Nuclear Grade
OBJECTIVE. The purpose of this study is to investigate the predictive performance of machine learning (ML)–based unenhanced CT texture analysis in distinguishing low (grades I and II) and high (grades III and IV) nuclear grade clear cell renal cell carcinomas (RCCs). MATERIALS AND METHODS. For this retrospective study, 81 patients with clear cell RCC (56 high and 25 low nuclear grade) were included from a public database. Using 2D manual segmentation, 744 texture features were extracted from unenhanced CT images. Dimension reduction was done in three consecutive steps: reproducibility analysis by two radiologists, collinearity analysis, and feature selection. Models were created using artificial neural network (ANN) and binary logistic regression, with and without synthetic minority oversampling technique (SMOTE), and were validated using 10-fold cross-validation. The reference standard was histopathologic nuclear grade (low vs high). RESULTS. Dimension reduction steps yielded five texture features for th...
- 1 June 2019
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 212 (6) , W132-W139
Unenhanced CT Texture Analysis of Clear Cell Renal Cell Carcinomas: A Machine Learning–Based Study for Predicting Histopathologic Nuclear Grade
OBJECTIVE. The purpose of this study is to investigate the predictive performance of machine learning (ML)–based unenhanced CT texture analysis in distinguishing low (grades I and II) and high (grades III and IV) nuclear grade clear cell renal cell carcinomas (RCCs). MATERIALS AND METHODS. For this retrospective study, 81 patients with clear cell RCC (56 high and 25 low nuclear grade) were included from a public database. Using 2D manual segmentation, 744 texture features were extracted from unenhanced CT images. Dimension reduction was done in three consecutive steps: reproducibility analysis by two radiologists, collinearity analysis, and feature selection. Models were created using artificial neural network (ANN) and binary logistic regression, with and without synthetic minority oversampling technique (SMOTE), and were validated using 10-fold cross-validation. The reference standard was histopathologic nuclear grade (low vs high). RESULTS. Dimension reduction steps yielded five texture features for th...