Miranda van Berkel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Miranda van Berkel has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Christian Victor Hulzebos
Department of Neonatology, Beatrix Children's Hospital, University Medical Center Groningen, Groningen, The Netherlands
3 shared publications - Albertine E. Donker
Radboud Iron Expertise Center, Radboud University Medical Center , Nijmegen 6525 GA 10
2 shared publications - Christine H. Ten Hove
Department of Pediatrics , Rijnstate Hospital , Arnhem , The Netherlands
2 shared publications - Dorine. W. Swinkels
Department of Laboratory Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
2 shared publications - Joost G. J. Hoenderop
Radboud University Medical Center
2 shared publications - Marc Thelen
Department of Laboratory Medicine , Radboud University Medical Center , Nijmegen , The Netherlands
2 shared publications
Latest Publications
- Open Access
- 22 June 2026
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 64 (11) , 2522-2530
Novel Specturi urine collector device demonstrating high measurement accuracy and proven clinical usability
Objectives: Urine collection from neonates and infants remains challenging. Non-invasive urine collection methods (UCMs) are preferred, but they are often associated with drawbacks, such as feces contamination, discomfort, and/or inaccurate urinary analysis. This study aimed to demonstrate the measurement accuracy and clinical usability of the Specturi urine collector device. Methods: 25 different urines were incubated in the Specturi urine collector device and three non-invasive UCMs, namely gauzes, urine collection bag, and PeeSpot, for 3 h at 37 °C. Albumin, calcium, chloride, creatinine, glucose, magnesium, phosphate, potassium, protein, sodium, and urea concentrations as well as osmolality and pH were measured in the extracted urines and compared to a control. The measurements were also compared between the different UCMs. In addition, a clinical pilot study was performed with the Specturi urine collector device to assess the usability and safety as indicated by nurses and parents. Results: The novel Specturi urine collector device offered accurate measurements of the various urinary analytes. Its measurement accuracy was comparable to the urine collection bag and PeeSpot and more accurate than gauzes. Nurses indicated that the Specturi urine collector device was easy to use, noting the ease of application and removal. Both nurses and parents indicated that the participants experienced no discomfort while wearing the Specturi urine collector device and no significant skin reactions were observed, unlike for other UCMs. Conclusions: The Specturi urine collector device is a novel non-invasive UCM, offering accurate urinary analysis, ensuring patient safety and comfort, and providing easy usage by nurses.
- 22 June 2026
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 64 (11) , 2522-2530
Open AccessNovel Specturi urine collector device demonstrating high measurement accuracy and proven clinical usability
Objectives: Urine collection from neonates and infants remains challenging. Non-invasive urine collection methods (UCMs) are preferred, but they are often associated with drawbacks, such as feces contamination, discomfort, and/or inaccurate urinary analysis. This study aimed to demonstrate the measurement accuracy and clinical usability of the Specturi urine collector device. Methods: 25 different urines were incubated in the Specturi urine collector device and three non-invasive UCMs, namely gauzes, urine collection bag, and PeeSpot, for 3 h at 37 °C. Albumin, calcium, chloride, creatinine, glucose, magnesium, phosphate, potassium, protein, sodium, and urea concentrations as well as osmolality and pH were measured in the extracted urines and compared to a control. The measurements were also compared between the different UCMs. In addition, a clinical pilot study was performed with the Specturi urine collector device to assess the usability and safety as indicated by nurses and parents. Results: The novel Specturi urine collector device offered accurate measurements of the various urinary analytes. Its measurement accuracy was comparable to the urine collection bag and PeeSpot and more accurate than gauzes. Nurses indicated that the Specturi urine collector device was easy to use, noting the ease of application and removal. Both nurses and parents indicated that the participants experienced no discomfort while wearing the Specturi urine collector device and no significant skin reactions were observed, unlike for other UCMs. Conclusions: The Specturi urine collector device is a novel non-invasive UCM, offering accurate urinary analysis, ensuring patient safety and comfort, and providing easy usage by nurses.
- Open Access
- 13 April 2026
- Published by Springer Nature in Pediatric Research
A novel urine collection device for accurate urinary measurements in neonates and pre-continent infants
Urine collection from neonates and infants is challenging. All available urine collection methods (UCMs) have their disadvantages, like invasiveness, contamination, and/or inaccurate measurements of urinary components. This study aimed to demonstrate the accuracy of measurements of urinary components for the novel non-invasive 'Specturi urine collector device'. The urine collection textile was incubated under different conditions (incubation duration, temperature, and humidity) with either artificial or human urine. Concentrations of urinary components were compared before and after incubation. Because of suspected crystal formation, the effect of acidification was assessed in combination with crystal analysis. Urinary concentrations of calcium, magnesium, phosphate, sodium, creatinine, and protein, and pH were accurately measured, except for the calcium concentration in alkaline urines. The incubation conditions showed no to a small effect on the measurement of urinary components, which does not affect clinical decision-making. Crystals containing calcium, magnesium, and phosphorus formed on the textile after incubation with alkaline urine. Acidification recovered the calcium concentration in these urines. The non-invasive 'Specturi urine collector device' provides accurate measurements of urinary components under different conditions. This UCM is more accurate than other textile-based UCMs. Eventually, this device can be used as an accurate as well as patient- and staff-friendly UCM. All urine collection methods for neonates and pre-continent infants have their disadvantages, and textile-based urine collection methods provide inaccurate measurements of urinary components. Furthermore, the effect of changing environmental conditions on measurements of urinary components is unknown for these urine collection methods. This study introduces the 'Specturi urine collector device', a novel non-invasive urine collection device. This device provides accurate measurements for different urinary components under different conditions, like incubation duration, temperature, and humidity. The results show that the 'Specturi urine collector device' has the potential to become an alternative non-invasive urine collection method that is accurate, and patient- and staff-friendly.
- 13 April 2026
- Published by Springer Nature in Pediatric Research
Open AccessA novel urine collection device for accurate urinary measurements in neonates and pre-continent infants
Urine collection from neonates and infants is challenging. All available urine collection methods (UCMs) have their disadvantages, like invasiveness, contamination, and/or inaccurate measurements of urinary components. This study aimed to demonstrate the accuracy of measurements of urinary components for the novel non-invasive 'Specturi urine collector device'. The urine collection textile was incubated under different conditions (incubation duration, temperature, and humidity) with either artificial or human urine. Concentrations of urinary components were compared before and after incubation. Because of suspected crystal formation, the effect of acidification was assessed in combination with crystal analysis. Urinary concentrations of calcium, magnesium, phosphate, sodium, creatinine, and protein, and pH were accurately measured, except for the calcium concentration in alkaline urines. The incubation conditions showed no to a small effect on the measurement of urinary components, which does not affect clinical decision-making. Crystals containing calcium, magnesium, and phosphorus formed on the textile after incubation with alkaline urine. Acidification recovered the calcium concentration in these urines. The non-invasive 'Specturi urine collector device' provides accurate measurements of urinary components under different conditions. This UCM is more accurate than other textile-based UCMs. Eventually, this device can be used as an accurate as well as patient- and staff-friendly UCM. All urine collection methods for neonates and pre-continent infants have their disadvantages, and textile-based urine collection methods provide inaccurate measurements of urinary components. Furthermore, the effect of changing environmental conditions on measurements of urinary components is unknown for these urine collection methods. This study introduces the 'Specturi urine collector device', a novel non-invasive urine collection device. This device provides accurate measurements for different urinary components under different conditions, like incubation duration, temperature, and humidity. The results show that the 'Specturi urine collector device' has the potential to become an alternative non-invasive urine collection method that is accurate, and patient- and staff-friendly.
- Open Access
- 23 January 2026
- Published by Oxford University Press (OUP) in The Journal of Applied Laboratory Medicine
- Vol. 11 (3) , 632-646
Why Metrological Traceability Matters in Medical Laboratory Diagnostics
Application of the results provided by medical laboratories plays an essential role in medical decision-making. This is not limited to diagnosis and monitoring of disease but also involves its use in other phases of the health continuum, e.g., predisposition, risk stratification, screening, staging, prognosis, and surveillance. With the growing importance of precision medicine, the importance of requirements related to clinical performance, and consequently analytical performance of laboratory tests, also grows. To allow the community of laboratory medicine to translate clinical need into a test arsenal with adequate performance, the application of metrology concepts is essential. This paper summarizes, for all steps in the examination process from test development to clinical interpretation, why and how metrological traceability is a fundamental requirement for adequate medical decision-making and is critical for correct use of test results in algorithms and artificial intelligence-led approaches. This includes the importance of metrology concepts and their correct implementation for obtaining equivalence of test results upon cross-facility result exchange for primary or secondary use in healthcare and research. This is not limited to biochemistry and hematology but is also of importance to other areas of laboratory medicine, including microbiology. This paper provides an overview of the purposes of the underappreciated science of metrology in modern laboratory medicine and its importance to patients and caregivers.
- 23 January 2026
- Published by Oxford University Press (OUP) in The Journal of Applied Laboratory Medicine
- Vol. 11 (3) , 632-646
Open AccessWhy Metrological Traceability Matters in Medical Laboratory Diagnostics
Application of the results provided by medical laboratories plays an essential role in medical decision-making. This is not limited to diagnosis and monitoring of disease but also involves its use in other phases of the health continuum, e.g., predisposition, risk stratification, screening, staging, prognosis, and surveillance. With the growing importance of precision medicine, the importance of requirements related to clinical performance, and consequently analytical performance of laboratory tests, also grows. To allow the community of laboratory medicine to translate clinical need into a test arsenal with adequate performance, the application of metrology concepts is essential. This paper summarizes, for all steps in the examination process from test development to clinical interpretation, why and how metrological traceability is a fundamental requirement for adequate medical decision-making and is critical for correct use of test results in algorithms and artificial intelligence-led approaches. This includes the importance of metrology concepts and their correct implementation for obtaining equivalence of test results upon cross-facility result exchange for primary or secondary use in healthcare and research. This is not limited to biochemistry and hematology but is also of importance to other areas of laboratory medicine, including microbiology. This paper provides an overview of the purposes of the underappreciated science of metrology in modern laboratory medicine and its importance to patients and caregivers.
- Open Access
- 15 January 2026
- Published by Oxford University Press (OUP) in Journal of Sickle Cell Disease
- Vol. 3 (1)
Biomarker profiles in distinct clinical subphenotypes of SCD: an explorative study
Objective: To evaluate biomarkers of glomerular, tubular, and endothelial function in patients with SCD, focusing on differences between hemolysis-dominant and vaso-occlusion–dominant subphenotypes. Methods: This monocenter exploratory pilot study included 25 patients with SCD (21 HbSS, 4 HbSC) from the Radboud Iron Biobank. Primary analyses were restricted to 12 adults with HbSS, categorized into hemolysis‑dominant (HD, n = 8) and vaso‑occlusion–dominant (VOD, n = 4) subphenotypes. Serum and urine samples were collected during routine outpatient visits in clinically stable patients without any signs of sickle cell crises. Biomarkers reflecting glomerular function, tubular injury, and endothelial activation were quantified using nephelometry, ELISA, and routine clinical chemistry assays. Associations between biomarkers and clinical parameters were assessed using non‑parametric correlation analyses. Results: Microalbuminuria was observed in 5 adults, mainly in the hemolysis-dominant (HD) subgroup (n = 4). No cases of macroalbuminuria were identified. Other urinary markers (NGAL, KIM-1) were within reference intervals and did not distinguish between clinical subphenotypes; urinary cystatin C was largely unquantifiable. Findings in children were comparable, with no evidence of albuminuria. Exploratory analyses suggested lower renal biomarker levels in hydroxyurea-treated patients. Correlation analyses revealed a hemolysis-associated cluster, with strong associations between sFLT-1 and LDH, bilirubin, and reticulocytes. Conclusion: In this outpatient cohort, overt sickle cell nephropathy was not evident, and urinary biomarkers were largely within the reference intervals in a stable clinical situation without sickle cell crises. However, a hemolysis-associated endothelial signature was observed, involving sFLT-1. Larger longitudinal studies are needed to validate these preliminary findings before implementation in clinical practice.
- 15 January 2026
- Published by Oxford University Press (OUP) in Journal of Sickle Cell Disease
- Vol. 3 (1)
Open AccessBiomarker profiles in distinct clinical subphenotypes of SCD: an explorative study
Objective: To evaluate biomarkers of glomerular, tubular, and endothelial function in patients with SCD, focusing on differences between hemolysis-dominant and vaso-occlusion–dominant subphenotypes. Methods: This monocenter exploratory pilot study included 25 patients with SCD (21 HbSS, 4 HbSC) from the Radboud Iron Biobank. Primary analyses were restricted to 12 adults with HbSS, categorized into hemolysis‑dominant (HD, n = 8) and vaso‑occlusion–dominant (VOD, n = 4) subphenotypes. Serum and urine samples were collected during routine outpatient visits in clinically stable patients without any signs of sickle cell crises. Biomarkers reflecting glomerular function, tubular injury, and endothelial activation were quantified using nephelometry, ELISA, and routine clinical chemistry assays. Associations between biomarkers and clinical parameters were assessed using non‑parametric correlation analyses. Results: Microalbuminuria was observed in 5 adults, mainly in the hemolysis-dominant (HD) subgroup (n = 4). No cases of macroalbuminuria were identified. Other urinary markers (NGAL, KIM-1) were within reference intervals and did not distinguish between clinical subphenotypes; urinary cystatin C was largely unquantifiable. Findings in children were comparable, with no evidence of albuminuria. Exploratory analyses suggested lower renal biomarker levels in hydroxyurea-treated patients. Correlation analyses revealed a hemolysis-associated cluster, with strong associations between sFLT-1 and LDH, bilirubin, and reticulocytes. Conclusion: In this outpatient cohort, overt sickle cell nephropathy was not evident, and urinary biomarkers were largely within the reference intervals in a stable clinical situation without sickle cell crises. However, a hemolysis-associated endothelial signature was observed, involving sFLT-1. Larger longitudinal studies are needed to validate these preliminary findings before implementation in clinical practice.
- Open Access
- 1 January 2026
- Published by Wiley in Advances in Hematology
- Vol. 2026 (1) , 8684436
Urinary Proteomic Signatures in Sickle Cell Disease: Search for Biomarkers Associated With Underlying Molecular Pathways
Identifying urinary biomarkers of sickle cell disease (SCD) may provide insights into disease mechanisms and support improved disease monitoring. In this pilot study, we analyzed the urinary proteome of 32 SCD patients (children and adults, steady state, and various genotypes) and 19 healthy controls using mass spectrometry‐based proteomics. A total of 2263 proteins were detected, of which 978 were consistently quantified across groups. Ninety proteins showed differential abundance between SCD patients and controls, with 26 upregulated and 64 downregulated in SCD. Upregulated proteins included those associated with cellular stress response (e.g., DNA damage‐inducible 1 homolog 2) and immune activation, whereas proteins involved in hemoglobin clearance and mitochondrial metabolism were downregulated, consistent with hemolysis and mitochondrial dysfunction. These findings suggest that urinary proteomics can capture systemic processes relevant to SCD pathophysiology. Despite the small and heterogeneous cohort, this study highlights candidate urinary biomarkers and molecular pathways that warrant validation in larger, stratified cohorts to assess their potential for disease monitoring.
- 1 January 2026
- Published by Wiley in Advances in Hematology
- Vol. 2026 (1) , 8684436
Open AccessUrinary Proteomic Signatures in Sickle Cell Disease: Search for Biomarkers Associated With Underlying Molecular Pathways
Identifying urinary biomarkers of sickle cell disease (SCD) may provide insights into disease mechanisms and support improved disease monitoring. In this pilot study, we analyzed the urinary proteome of 32 SCD patients (children and adults, steady state, and various genotypes) and 19 healthy controls using mass spectrometry‐based proteomics. A total of 2263 proteins were detected, of which 978 were consistently quantified across groups. Ninety proteins showed differential abundance between SCD patients and controls, with 26 upregulated and 64 downregulated in SCD. Upregulated proteins included those associated with cellular stress response (e.g., DNA damage‐inducible 1 homolog 2) and immune activation, whereas proteins involved in hemoglobin clearance and mitochondrial metabolism were downregulated, consistent with hemolysis and mitochondrial dysfunction. These findings suggest that urinary proteomics can capture systemic processes relevant to SCD pathophysiology. Despite the small and heterogeneous cohort, this study highlights candidate urinary biomarkers and molecular pathways that warrant validation in larger, stratified cohorts to assess their potential for disease monitoring.
- Open Access
- 30 December 2025
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 72 (1) , 183-191
Evaluation of Total Bilirubin in a National Quality Program
Background: Accurate quantification of neonatal bilirubin remains a perennial challenge. To monitor analytical performance of total bilirubin measurements across hospitals in the Netherlands, a dedicated neonatal external quality assessment (EQA) program is in place. Methods: We retrospectively analyzed Dutch EQA data from 2013 until 2025. Each year, the 81 participating laboratories received 24 pooled adult blood serum samples spiked with unconjugated bilirubin (range 100–400 µmol/L or 5.85–23.40 mg/dL). Bias from the target value determined by the reference measurement procedure (RMP) and the coefficient of variation (CV) were established for both unfactored and factored measurements. Results: In total, 25 983 bilirubin measurements were analyzed. Three analytical principles were used on 12 platforms from 6 manufacturers. Diazo-based methods exhibited the lowest median bias (+0.4% in 2024), alongside spectrophotometric methods (−3.8% in 2024). Vanadate-based methods showed a bias of +19.5% in 2024 that was reduced to +3.0% for factored measurements. Substantial differences in bias were observed among manufacturers and platforms, with some exhibiting concentration dependency. Comparable patterns were seen for CVs, which generally remained below 5%. Conclusion: EQA results demonstrated temporal variability in bias across all analytical principles, manufacturers, and platforms used for neonatal bilirubin assays. Bias was found to vary with bilirubin concentration. Standardization of neonatal bilirubin assays is urgently needed to ensure more reliable and accurate measurements across different systems. Meanwhile, EQA programs are important in monitoring future assay adjustments to ensure appropriate and consistent management of neonatal hyperbilirubinemia.
- 30 December 2025
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 72 (1) , 183-191
Open AccessEvaluation of Total Bilirubin in a National Quality Program
Background: Accurate quantification of neonatal bilirubin remains a perennial challenge. To monitor analytical performance of total bilirubin measurements across hospitals in the Netherlands, a dedicated neonatal external quality assessment (EQA) program is in place. Methods: We retrospectively analyzed Dutch EQA data from 2013 until 2025. Each year, the 81 participating laboratories received 24 pooled adult blood serum samples spiked with unconjugated bilirubin (range 100–400 µmol/L or 5.85–23.40 mg/dL). Bias from the target value determined by the reference measurement procedure (RMP) and the coefficient of variation (CV) were established for both unfactored and factored measurements. Results: In total, 25 983 bilirubin measurements were analyzed. Three analytical principles were used on 12 platforms from 6 manufacturers. Diazo-based methods exhibited the lowest median bias (+0.4% in 2024), alongside spectrophotometric methods (−3.8% in 2024). Vanadate-based methods showed a bias of +19.5% in 2024 that was reduced to +3.0% for factored measurements. Substantial differences in bias were observed among manufacturers and platforms, with some exhibiting concentration dependency. Comparable patterns were seen for CVs, which generally remained below 5%. Conclusion: EQA results demonstrated temporal variability in bias across all analytical principles, manufacturers, and platforms used for neonatal bilirubin assays. Bias was found to vary with bilirubin concentration. Standardization of neonatal bilirubin assays is urgently needed to ensure more reliable and accurate measurements across different systems. Meanwhile, EQA programs are important in monitoring future assay adjustments to ensure appropriate and consistent management of neonatal hyperbilirubinemia.
- Open Access
- 6 November 2025
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 26 (21) , 10791
Bilirubin Photoisomers in Neonatal Jaundice
Phototherapy is the standard treatment for neonatal hyperbilirubinemia. During phototherapy, the highly lipophilic bilirubin is converted into more hydrophilic photoisomers, which can be more easily excreted from the body. This process typically lowers bilirubin levels to non-harmful concentrations. However, despite decades of research into the formation and role of bilirubin photoisomers, methodological limitations and the compound’s complex biochemistry have hindered comprehensive understanding. This review provides an updated overview of current knowledge on bilirubin photoisomers, including their basic chemistry, analytical quantification, clinical relevance, and future research directions. Improved insight into the mechanism of photoisomer formation and kinetics may inform optimization of phototherapy parameters, including light intensity and wavelength, and offer additional indicators of treatment efficacy beyond total bilirubin concentration. Advances in sensitive and standardized mass spectrometry techniques now enable more accurate measurement of different bilirubin isomers and serve as a first step towards a deeper insight into the clinical relevance of photoisomers.
- 6 November 2025
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 26 (21) , 10791
Open AccessBilirubin Photoisomers in Neonatal Jaundice
Phototherapy is the standard treatment for neonatal hyperbilirubinemia. During phototherapy, the highly lipophilic bilirubin is converted into more hydrophilic photoisomers, which can be more easily excreted from the body. This process typically lowers bilirubin levels to non-harmful concentrations. However, despite decades of research into the formation and role of bilirubin photoisomers, methodological limitations and the compound’s complex biochemistry have hindered comprehensive understanding. This review provides an updated overview of current knowledge on bilirubin photoisomers, including their basic chemistry, analytical quantification, clinical relevance, and future research directions. Improved insight into the mechanism of photoisomer formation and kinetics may inform optimization of phototherapy parameters, including light intensity and wavelength, and offer additional indicators of treatment efficacy beyond total bilirubin concentration. Advances in sensitive and standardized mass spectrometry techniques now enable more accurate measurement of different bilirubin isomers and serve as a first step towards a deeper insight into the clinical relevance of photoisomers.
- Open Access
- 24 January 2025
- Published by Elsevier in Clinical Nutrition ESPEN
- Vol. 66, 262-268
Accurate urine sodium measurements at home using point of care testing in patients with short bowel syndrome
- 24 January 2025
- Published by Elsevier in Clinical Nutrition ESPEN
- Vol. 66, 262-268
Open AccessAccurate urine sodium measurements at home using point of care testing in patients with short bowel syndrome
- Open Access
- 5 March 2024
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 62 (10) , 1892-1903
Bilirubin measurements in neonates: uniform neonatal treatment can only be achieved by improved standardization
Measurement of total bilirubin (TBil) concentration in serum is the gold standard approach for diagnosing neonatal unconjugated hyperbilirubinemia. It is of utmost importance that the measured TBil concentration is sufficiently accurate to prevent under treatment, unnecessary escalation of care, or overtreatment. However, it is widely recognized that TBil measurements urgently require improvement in neonatal clinical chemistry. External quality assessment (EQA) programs for TBil assess for differences between laboratories and provide supporting evidence of significant differences between various methods, manufacturers and measurement platforms. At the same time, many countries have adopted or only slightly adapted the neonatal hyperbilirubinemia management guidelines from the USA or UK, often without addressing differences in the methodology of TBil measurements. In this report, we provide an overview of the components of bilirubin that are measured by laboratory platforms, the availability of current reference measurement procedures and reference materials, and the role of EQA surveys in this context. Furthermore, the current status of agreement in neonatal bilirubin against clinical decision thresholds is reviewed. We advocate for enhancements in accuracy and comparability of neonatal TBil measurements, propose a path forward to accomplish this, and reflect on the position of the International Federation for Clinical Chemistry and Laboratory Medicine (IFCC) Working Group Neonatal Bilirubin (WG-NB) in this matter.
- 5 March 2024
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 62 (10) , 1892-1903
Open AccessBilirubin measurements in neonates: uniform neonatal treatment can only be achieved by improved standardization
Measurement of total bilirubin (TBil) concentration in serum is the gold standard approach for diagnosing neonatal unconjugated hyperbilirubinemia. It is of utmost importance that the measured TBil concentration is sufficiently accurate to prevent under treatment, unnecessary escalation of care, or overtreatment. However, it is widely recognized that TBil measurements urgently require improvement in neonatal clinical chemistry. External quality assessment (EQA) programs for TBil assess for differences between laboratories and provide supporting evidence of significant differences between various methods, manufacturers and measurement platforms. At the same time, many countries have adopted or only slightly adapted the neonatal hyperbilirubinemia management guidelines from the USA or UK, often without addressing differences in the methodology of TBil measurements. In this report, we provide an overview of the components of bilirubin that are measured by laboratory platforms, the availability of current reference measurement procedures and reference materials, and the role of EQA surveys in this context. Furthermore, the current status of agreement in neonatal bilirubin against clinical decision thresholds is reviewed. We advocate for enhancements in accuracy and comparability of neonatal TBil measurements, propose a path forward to accomplish this, and reflect on the position of the International Federation for Clinical Chemistry and Laboratory Medicine (IFCC) Working Group Neonatal Bilirubin (WG-NB) in this matter.
- Open Access
- 5 August 2021
- Published by Springer Nature in Critical Care
- Vol. 25 (1) , 1-12
Dexamethasone and tocilizumab treatment considerably reduces the value of C-reactive protein and procalcitonin to detect secondary bacterial infections in COVID-19 patients
Background: Procalcitonin (PCT) and C-reactive protein (CRP) were previously shown to have value for the detection of secondary infections in critically ill COVID-19 patients. However, since the introduction of immunomodulatory therapy, the value of these biomarkers is unclear. We investigated PCT and CRP kinetics in critically ill COVID-19 patients treated with dexamethasone with or without tocilizumab, and assessed the value of these biomarkers to detect secondary bacterial infections.Methods: In this prospective study, 190 critically ill COVID-19 patients were divided into three treatment groups:no dexamethasone, no tocilizumab (D−T−),dexamethasone, no tocilizumab (D+T−), anddexamethasone and tocilizumab (D+T+). Serial data of PCT and CRP were aligned on the last day of dexamethasone treatment, and kinetics of these biomarkers were analyzed between 6 days prior to cessation of dexamethasone and 10 days afterwards. Furthermore, the D+T− and D+T+ groups were subdivided into secondary infection and no-secondary infection groups to analyze differences in PCT and CRP kinetics and calculate detection accuracy of these biomarkers for the occurrence of a secondary infection.Results: Following cessation of dexamethasone, there was a rebound in PCT and CRP levels, most pronounced in the D+T− group. Upon occurrence of a secondary infection, no significant increase in PCT and CRP levels was observed in the D+T− group (p = 0.052 andp = 0.08, respectively). Although PCT levels increased significantly in patients of the D+T+ group who developed a secondary infection (p = 0.0003), this rise was only apparent from day 2 post-infection onwards. CRP levels remained suppressed in the D+T+ group. Receiver operating curve analysis of PCT and CRP levels yielded area under the curves of 0.52 and 0.55, respectively, which are both markedly lower than those found in the group of COVID-19 patients not treated with immunomodulatory drugs (0.80 and 0.76, respectively, withpvalues for differences between groups of 0.001 and 0.02, respectively).Conclusions: Cessation of dexamethasone in critically ill COVID-19 patients results in a rebound increase in PCT and CRP levels unrelated to the occurrence of secondary bacterial infections. Furthermore, immunomodulatory treatment with dexamethasone and tocilizumabconsiderably reducesthe value of PCT and CRP for detection of secondary infections in COVID-19 patients.
- 5 August 2021
- Published by Springer Nature in Critical Care
- Vol. 25 (1) , 1-12
Open AccessDexamethasone and tocilizumab treatment considerably reduces the value of C-reactive protein and procalcitonin to detect secondary bacterial infections in COVID-19 patients
Background: Procalcitonin (PCT) and C-reactive protein (CRP) were previously shown to have value for the detection of secondary infections in critically ill COVID-19 patients. However, since the introduction of immunomodulatory therapy, the value of these biomarkers is unclear. We investigated PCT and CRP kinetics in critically ill COVID-19 patients treated with dexamethasone with or without tocilizumab, and assessed the value of these biomarkers to detect secondary bacterial infections.Methods: In this prospective study, 190 critically ill COVID-19 patients were divided into three treatment groups:no dexamethasone, no tocilizumab (D−T−),dexamethasone, no tocilizumab (D+T−), anddexamethasone and tocilizumab (D+T+). Serial data of PCT and CRP were aligned on the last day of dexamethasone treatment, and kinetics of these biomarkers were analyzed between 6 days prior to cessation of dexamethasone and 10 days afterwards. Furthermore, the D+T− and D+T+ groups were subdivided into secondary infection and no-secondary infection groups to analyze differences in PCT and CRP kinetics and calculate detection accuracy of these biomarkers for the occurrence of a secondary infection.Results: Following cessation of dexamethasone, there was a rebound in PCT and CRP levels, most pronounced in the D+T− group. Upon occurrence of a secondary infection, no significant increase in PCT and CRP levels was observed in the D+T− group (p = 0.052 andp = 0.08, respectively). Although PCT levels increased significantly in patients of the D+T+ group who developed a secondary infection (p = 0.0003), this rise was only apparent from day 2 post-infection onwards. CRP levels remained suppressed in the D+T+ group. Receiver operating curve analysis of PCT and CRP levels yielded area under the curves of 0.52 and 0.55, respectively, which are both markedly lower than those found in the group of COVID-19 patients not treated with immunomodulatory drugs (0.80 and 0.76, respectively, withpvalues for differences between groups of 0.001 and 0.02, respectively).Conclusions: Cessation of dexamethasone in critically ill COVID-19 patients results in a rebound increase in PCT and CRP levels unrelated to the occurrence of secondary bacterial infections. Furthermore, immunomodulatory treatment with dexamethasone and tocilizumabconsiderably reducesthe value of PCT and CRP for detection of secondary infections in COVID-19 patients.