Huancai Yin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Huancai Yin has a total of 95 co-authors. Here are the top co-authors by number of shared publications:
- Jian Yin
School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine University of Science and Technology of China Suzhou Jiangsu China
9 shared publications Jiaojiao Sun
6 shared publicationsJingjing Tian
CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, PR China; Academy for Engineering & Technology, Fudan University, Shanghai 200433, PR China
6 shared publicationsJian Yin
5 shared publicationsMingli Chen
5 shared publications- Rui Sun
School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Suzhou, Jiangsu 215163, P. R. China
4 shared publications
Latest Publications
- 31 March 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1405, 345468
A triple-mode SERS-LFIA platform based on Au@4-MBA@Ag core-shell nanorods for ultrasensitive point-of-care detection of cortisol
- 31 March 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1405, 345468
A triple-mode SERS-LFIA platform based on Au@4-MBA@Ag core-shell nanorods for ultrasensitive point-of-care detection of cortisol
- Open Access
- 9 March 2026
- Published by Frontiers Media SA in Frontiers in Cellular and Infection Microbiology
- Vol. 16, 1779950
From proteomics to colloidal gold tests for urinary thrombomodulin: a prospective cohort study on accurate sepsis screening
Background: To develop a new non-invasive screening method for sepsis by detecting urine samples. Methods: A prospective study was conducted to collect urine samples from a cohort of 22 individuals diagnosed with sepsis and admitted to the Intensive Care Unit (ICU) of a university-affiliated teaching hospital in China. Utilizing proteomic and bioinformatics analyses, we sought to identify potential biomarkers indicative of sepsis. These biomarkers were subsequently validated using serum and urine samples from 31 patients with septic shock, 83 patients with sepsis, and 50 healthy controls. Receiver operating characteristic (ROC) curves were employed to determine the optimal cutoff values for these biomarkers. Based on the diagnostic thresholds derived from ROC analysis, colloidal gold test strips were developed and applied to screen a cohort of 92 ICU patients. The diagnostic accuracy of these test strips was rigorously assessed by comparing their results with those from immunofluorescence assays. Results: Data-independent acquisition (DIA) proteomics analysis of urine samples identified 2,846 proteins, with stringent filtration criteria (fold change > 2 or < 0.5, P-value < 0.05) yielding 178 differentially expressed proteins (DEPs). Kyoto Encyclopedia of Genes and Genomes (KEGG) pathway enrichment analysis revealed significant enrichment of DEPs in pathways associated with “cell adhesion molecules,” “lysosomes,” and metabolic processes. The Boruta algorithm, integrating Random Forest and Support Vector Machine (SVM) analysis, identified urinary thrombomodulin (TM) as a key candidate molecule. Immunofluorescence analysis for validation trial showed rising trend in blood TM levels across disease severities: 7.55 (6.58-8.72) TU/mL in healthy controls, 10.08 (8.00-14.15) TU/mL in general sepsis, and 12.30 (7.54-18.68) TU/mL in septic shock. Conversely, urinary TM levels decreased: 23.65 (18.08-31.06) TU/mL, 17.70 (13.80-28.80) TU/mL, and 5.84 (4.00-11.59) TU/mL, respectively. At a urinary TM threshold of 15.46 TU/mL, the ROC AUC for sepsis diagnosis is 0.72, with 57% sensitivity and 88% specificity (P0.05). For septic shock diagnosis and 28-day mortality prediction, a urinary TM threshold of 11.85 TU/mL yields an ROC AUC of 0.92, with 93% sensitivity and 81% specificity, outperforming blood TM (P<0.05). A urinary TM colloidal gold test strip, which turns red at TM levels above 15.46 TU/mL, was developed and validated on urine samples from 43 sepsis and 49 non-sepsis patients, achieving 86.1% sensitivity, 77.6% specificity and an overall accuracy of 81.5% for sepsis diagnosis. The Kappa test validated the concordance of the colloidal gold strip test with Sepsis 3.0 diagnostic criteria, while the McNemar test indicated no significant difference in sepsis diagnosis efficacy between the strip test and chemiluminescent immunofluorescence (p=0.228). Conclusions: The utilization of urine test strips for the detection of TM offers a precise, convenient, and practical method for the screening of sepsis.
- 9 March 2026
- Published by Frontiers Media SA in Frontiers in Cellular and Infection Microbiology
- Vol. 16, 1779950
Open AccessFrom proteomics to colloidal gold tests for urinary thrombomodulin: a prospective cohort study on accurate sepsis screening
Background: To develop a new non-invasive screening method for sepsis by detecting urine samples. Methods: A prospective study was conducted to collect urine samples from a cohort of 22 individuals diagnosed with sepsis and admitted to the Intensive Care Unit (ICU) of a university-affiliated teaching hospital in China. Utilizing proteomic and bioinformatics analyses, we sought to identify potential biomarkers indicative of sepsis. These biomarkers were subsequently validated using serum and urine samples from 31 patients with septic shock, 83 patients with sepsis, and 50 healthy controls. Receiver operating characteristic (ROC) curves were employed to determine the optimal cutoff values for these biomarkers. Based on the diagnostic thresholds derived from ROC analysis, colloidal gold test strips were developed and applied to screen a cohort of 92 ICU patients. The diagnostic accuracy of these test strips was rigorously assessed by comparing their results with those from immunofluorescence assays. Results: Data-independent acquisition (DIA) proteomics analysis of urine samples identified 2,846 proteins, with stringent filtration criteria (fold change > 2 or < 0.5, P-value < 0.05) yielding 178 differentially expressed proteins (DEPs). Kyoto Encyclopedia of Genes and Genomes (KEGG) pathway enrichment analysis revealed significant enrichment of DEPs in pathways associated with “cell adhesion molecules,” “lysosomes,” and metabolic processes. The Boruta algorithm, integrating Random Forest and Support Vector Machine (SVM) analysis, identified urinary thrombomodulin (TM) as a key candidate molecule. Immunofluorescence analysis for validation trial showed rising trend in blood TM levels across disease severities: 7.55 (6.58-8.72) TU/mL in healthy controls, 10.08 (8.00-14.15) TU/mL in general sepsis, and 12.30 (7.54-18.68) TU/mL in septic shock. Conversely, urinary TM levels decreased: 23.65 (18.08-31.06) TU/mL, 17.70 (13.80-28.80) TU/mL, and 5.84 (4.00-11.59) TU/mL, respectively. At a urinary TM threshold of 15.46 TU/mL, the ROC AUC for sepsis diagnosis is 0.72, with 57% sensitivity and 88% specificity (P0.05). For septic shock diagnosis and 28-day mortality prediction, a urinary TM threshold of 11.85 TU/mL yields an ROC AUC of 0.92, with 93% sensitivity and 81% specificity, outperforming blood TM (P<0.05). A urinary TM colloidal gold test strip, which turns red at TM levels above 15.46 TU/mL, was developed and validated on urine samples from 43 sepsis and 49 non-sepsis patients, achieving 86.1% sensitivity, 77.6% specificity and an overall accuracy of 81.5% for sepsis diagnosis. The Kappa test validated the concordance of the colloidal gold strip test with Sepsis 3.0 diagnostic criteria, while the McNemar test indicated no significant difference in sepsis diagnosis efficacy between the strip test and chemiluminescent immunofluorescence (p=0.228). Conclusions: The utilization of urine test strips for the detection of TM offers a precise, convenient, and practical method for the screening of sepsis.
- 8 January 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (5) , 1116-1125
Development of a novel MSRE-dPCR assay for non-invasive prenatal testing of trisomy 21
Currently, next-generation sequencing (NGS)-based non-invasive prenatal diagnosis testing (NIPT) of fetal T21 has been proven to be much more advantageous than traditional serum biochemical tests in terms of accuracy and sensitivity.
- 8 January 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (5) , 1116-1125
Development of a novel MSRE-dPCR assay for non-invasive prenatal testing of trisomy 21
Currently, next-generation sequencing (NGS)-based non-invasive prenatal diagnosis testing (NIPT) of fetal T21 has been proven to be much more advantageous than traditional serum biochemical tests in terms of accuracy and sensitivity.
- Open Access
- 1 August 2025
- Published by Tsinghua University Press in Nano Research
- Vol. 18 (8)
Ligand-assisted core-cavity-corona cubic plasmonic nanostructures amplify immunoassays for ultrasensitive triple-mode sensing of thrombomodulin
Thrombomodulin (TM) is a critical biomarker for endothelial dysfunction, yet there is currently no simple and rapid detection method, such as immunochromatographic assay (ICA). Conventional gold nanoparticles (AuNPs)-based ICA suffers from limited sensitivity, making it unsuitable for detecting trace biomarkers. Herein, we introduced a ligand-assisted core-cavity-corona cubic plasmonic nanostructure (RCmC) amplifying immunoassays for ultrasensitive triple-mode (visual/optical/surface-enhanced Raman spectroscopy) detection of TM. This unique design features a cubic nanocage framework encapsulating an anisotropic gold nanorod and p-mercaptobenzoic acid Raman reporters internally, and decorated with surface-roughened nanocoronas externally. By coupling with the hydrophobic interactions of cetyltrimethylammonium chloride ligand, RCmC further enhanced antibody coupling efficiency, leading to a 2.5-fold increase in antibody adsorption compared to AuNPs. The RCmC-based ICA achieved a quantitative limit of detection of 0.005 ng·mL-1, providing a 346-fold enhancement in quantitative performance over AuNP-based ICA. Additionally, the detection process was drastically reduced to within 5 min, with recoveries ranging from 88.80% to 103.80% and coefficients of variation between 3.32% and 7.62% for serum and urine samples. These results were consistent with those from commercial enzyme-linked immunosorbent assay kits, demonstrating the significant potential of RCmC as a signal reporter for the ultrasensitive detection of trace biomarkers.
- 1 August 2025
- Published by Tsinghua University Press in Nano Research
- Vol. 18 (8)
Open AccessLigand-assisted core-cavity-corona cubic plasmonic nanostructures amplify immunoassays for ultrasensitive triple-mode sensing of thrombomodulin
Thrombomodulin (TM) is a critical biomarker for endothelial dysfunction, yet there is currently no simple and rapid detection method, such as immunochromatographic assay (ICA). Conventional gold nanoparticles (AuNPs)-based ICA suffers from limited sensitivity, making it unsuitable for detecting trace biomarkers. Herein, we introduced a ligand-assisted core-cavity-corona cubic plasmonic nanostructure (RCmC) amplifying immunoassays for ultrasensitive triple-mode (visual/optical/surface-enhanced Raman spectroscopy) detection of TM. This unique design features a cubic nanocage framework encapsulating an anisotropic gold nanorod and p-mercaptobenzoic acid Raman reporters internally, and decorated with surface-roughened nanocoronas externally. By coupling with the hydrophobic interactions of cetyltrimethylammonium chloride ligand, RCmC further enhanced antibody coupling efficiency, leading to a 2.5-fold increase in antibody adsorption compared to AuNPs. The RCmC-based ICA achieved a quantitative limit of detection of 0.005 ng·mL-1, providing a 346-fold enhancement in quantitative performance over AuNP-based ICA. Additionally, the detection process was drastically reduced to within 5 min, with recoveries ranging from 88.80% to 103.80% and coefficients of variation between 3.32% and 7.62% for serum and urine samples. These results were consistent with those from commercial enzyme-linked immunosorbent assay kits, demonstrating the significant potential of RCmC as a signal reporter for the ultrasensitive detection of trace biomarkers.
- 14 May 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (23) , 4796-4804
Development of a non-transfer microdroplet generation chip and digital molecular detection system
Droplet digital PCR (ddPCR) is a transformative technology for nucleic acid detection, offering exceptional sensitivity and absolute quantification. In this study, we developed a non-transfer microdroplet generation chip based on a cross-junction flow-focusing mechanism, enabling precise production of uniformly sized water-in-oil droplets. This chip integrates droplet generation and PCR amplification in a closed workflow, eliminating manual transfer steps and reducing contamination risks. Combined with a custom fluorescence reader, the system achieves a dynamic range of 1–104 copies per μL with high reproducibility (intra-/inter-batch CV vs. 95–131%) and linearity (R2 = 0.998 vs. 0.999). Critically, our platform offers three key advantages: (1) cost-effectiveness (lower chip production costs), (2) elimination of transfer steps: (avoids a major source of contamination and droplet loss), and (3) simplified workflow (reduction in hands-on time). These innovations position the system as a practical solution for applications demanding reliable low-abundance nucleic acid detection, such as liquid biopsy and pathogen surveillance.
- 14 May 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (23) , 4796-4804
Development of a non-transfer microdroplet generation chip and digital molecular detection system
Droplet digital PCR (ddPCR) is a transformative technology for nucleic acid detection, offering exceptional sensitivity and absolute quantification. In this study, we developed a non-transfer microdroplet generation chip based on a cross-junction flow-focusing mechanism, enabling precise production of uniformly sized water-in-oil droplets. This chip integrates droplet generation and PCR amplification in a closed workflow, eliminating manual transfer steps and reducing contamination risks. Combined with a custom fluorescence reader, the system achieves a dynamic range of 1–104 copies per μL with high reproducibility (intra-/inter-batch CV vs. 95–131%) and linearity (R2 = 0.998 vs. 0.999). Critically, our platform offers three key advantages: (1) cost-effectiveness (lower chip production costs), (2) elimination of transfer steps: (avoids a major source of contamination and droplet loss), and (3) simplified workflow (reduction in hands-on time). These innovations position the system as a practical solution for applications demanding reliable low-abundance nucleic acid detection, such as liquid biopsy and pathogen surveillance.
- 22 November 2024
- Published by Elsevier in Food and Chemical Toxicology
- Vol. 195, 115127
The role of surface modification in the interactions between CdTe quantum dots and ABC transporters in lung cancer cells
- 22 November 2024
- Published by Elsevier in Food and Chemical Toxicology
- Vol. 195, 115127
The role of surface modification in the interactions between CdTe quantum dots and ABC transporters in lung cancer cells
- 13 August 2024
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 149 (20) , 5041-5051
SERS detection of thiram using a 3D sea cucumber-like composite flexible porous substrate
Nowadays, trace detection of thiram is in urgent demand due to its widespread application in agriculture and significant harmful effects on public health. In this work, a three-dimensional (3D) sea cucumber-like flexible porous surface-enhanced Raman scattering (SERS) substrate composed of a poly(vinylidene fluoride) (PVDF) membrane, ZnO nanorods, gold films, and Ag nanoparticles (Ag/Au/ZnO/P) has been established for the highly sensitive detection of thiram. The substrate takes advantage of the 3D morphology of the Ag/Au/ZnO system on a flexible porous PVDF membrane to produce abundant plasmonic hot spots. Meanwhile, the employment of an AgNPs/Au shell system combined the benefits of both gold and silver metals, thus guaranteeing stable and sensitive detection. With 4-mercaptobenzoic acid (4-MBA) as a probe molecule, the Ag/Au/ZnO/P substrate exhibited excellent linear detection in the range of 10−11–10−5 M, with a correlation coefficient (R2) of 0.99 and an enhancement cofactor of 7.09 × 107. The substrate exhibited excellent uniformity with a related standard deviation (RSD) value of 3.82% and demonstrated high stability during a 15 d-storage test. In addition, the substrate could detect thiram in an aqueous solution at concentrations as low as 10−10 M with excellent selectivity. Meanwhile, thiram on the surface of apple peel could be easily detected by the Ag/Au/ZnO/P substrate with the “paste-and-peel” method in less than 10 s, and the detection limit could be as low as 0.48 ng cm−2. Overall, the remarkable performance of the Ag/Au/ZnO/P SERS substrate demonstrated its great potential for the environmental monitoring of thiram.
- 13 August 2024
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 149 (20) , 5041-5051
SERS detection of thiram using a 3D sea cucumber-like composite flexible porous substrate
Nowadays, trace detection of thiram is in urgent demand due to its widespread application in agriculture and significant harmful effects on public health. In this work, a three-dimensional (3D) sea cucumber-like flexible porous surface-enhanced Raman scattering (SERS) substrate composed of a poly(vinylidene fluoride) (PVDF) membrane, ZnO nanorods, gold films, and Ag nanoparticles (Ag/Au/ZnO/P) has been established for the highly sensitive detection of thiram. The substrate takes advantage of the 3D morphology of the Ag/Au/ZnO system on a flexible porous PVDF membrane to produce abundant plasmonic hot spots. Meanwhile, the employment of an AgNPs/Au shell system combined the benefits of both gold and silver metals, thus guaranteeing stable and sensitive detection. With 4-mercaptobenzoic acid (4-MBA) as a probe molecule, the Ag/Au/ZnO/P substrate exhibited excellent linear detection in the range of 10−11–10−5 M, with a correlation coefficient (R2) of 0.99 and an enhancement cofactor of 7.09 × 107. The substrate exhibited excellent uniformity with a related standard deviation (RSD) value of 3.82% and demonstrated high stability during a 15 d-storage test. In addition, the substrate could detect thiram in an aqueous solution at concentrations as low as 10−10 M with excellent selectivity. Meanwhile, thiram on the surface of apple peel could be easily detected by the Ag/Au/ZnO/P substrate with the “paste-and-peel” method in less than 10 s, and the detection limit could be as low as 0.48 ng cm−2. Overall, the remarkable performance of the Ag/Au/ZnO/P SERS substrate demonstrated its great potential for the environmental monitoring of thiram.