Daan Harm Wielens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Daan Harm Wielens has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Lennart Vincent de Groot
Paleomagnetic Laboratory Fort Hoofddijk Department of Earth Sciences Utrecht University Utrecht The Netherlands
6 shared publications - Rosa Anne de Boer
Paleomagnetic laboratory Fort Hoofddijk, Department of Earth Sciences, Utrecht University, The Netherlands
6 shared publications - Alexander Brinkman
University of Twente
4 shared publications - Christoph Baeumer
University of Twente
3 shared publications - Omar Concepción
Peter Grünberg Institute for Semiconductor Nanoelectronics (PGI-9), Forschungszentrum Jülich GmbH 4 , 52425 Jülich
3 shared publications - Bernard Abraham Boukamp
University of Twente
2 shared publications
Latest Publications
- Open Access
- 24 October 2026
- Published by Springer Nature in Communications Physics
Time-reversal symmetry breaking and inherent Josephson diodes in a multi-component order parameter superconductor
- 24 October 2026
- Published by Springer Nature in Communications Physics
Open AccessTime-reversal symmetry breaking and inherent Josephson diodes in a multi-component order parameter superconductor
- Open Access
- 14 March 2026
- Published by Copernicus GmbH
The challenge of correlating imaging datasets in geoscience
A broad range of microscopy tools and imaging techniques is available for studying geoscientific samples. Often, multiple imaging datasets are correlated to connect chemical and/or physical information to investigate complex systems. However, combining datasets obtained from different imaging techniques remains challenging. They often cannot be directly matched due to differences in resolution, scale, or instrument calibration.One solution is the application of markers on samples. Several techniques exist for applying markers on the surface of polished geoscientific samples, such as thin sections. These markers can be used during sample handling to identify the area of interest and ensure reproducible sample placement. After data acquisition, they enable accurate scaling and co-registration of different imaging datasets during data processing. Marker application techniques range from accessible, simple, and cost-effective approaches to more complex, specialized, and expensive methods, depending on the intended purpose.I will provide a brief overview of the available techniques and highlight the use of microlithography on thin sections, a technique that enables writing nano- to microsized symbols on sample surfaces. These markers provide a practical solution for simplifying the correlation of multiple datasets and support a deeper understanding in geoscientific research.
- 14 March 2026
- Published by Copernicus GmbH
Open AccessThe challenge of correlating imaging datasets in geoscience
A broad range of microscopy tools and imaging techniques is available for studying geoscientific samples. Often, multiple imaging datasets are correlated to connect chemical and/or physical information to investigate complex systems. However, combining datasets obtained from different imaging techniques remains challenging. They often cannot be directly matched due to differences in resolution, scale, or instrument calibration.One solution is the application of markers on samples. Several techniques exist for applying markers on the surface of polished geoscientific samples, such as thin sections. These markers can be used during sample handling to identify the area of interest and ensure reproducible sample placement. After data acquisition, they enable accurate scaling and co-registration of different imaging datasets during data processing. Marker application techniques range from accessible, simple, and cost-effective approaches to more complex, specialized, and expensive methods, depending on the intended purpose.I will provide a brief overview of the available techniques and highlight the use of microlithography on thin sections, a technique that enables writing nano- to microsized symbols on sample surfaces. These markers provide a practical solution for simplifying the correlation of multiple datasets and support a deeper understanding in geoscientific research.
- Open Access
- 10 March 2026
- Published by Springer Nature in Research Square
Magnetoresistance governs apparent magnetic-field enhancements in water electrolysis
The origin of the recently discovered magnetic-field-induced enhancement of the oxygen evolution reaction (OER) remains controversial, with partly contradictory experimental observations and several competing mechanistic interpretations. Using epitaxial multilayers as well-defined model systems, we disentangle the various effects induced by the applied magnetic field, and establish a quantitative correlation between the observed OER current increments and magnetoresistance (MR) effects. In parallel, operando magneto-optical Kerr effect (MOKE) microscopy was performed to evaluate the frequently proposed role of domain-wall removal. Surprisingly, the measured OER enhancements under magnetic field do not correlate with the appearance or disappearance of domain walls. We find no catalytic current enhancements when MR effects are eliminated. Our work thus reveals the strictly magnetoresistive origin of the observed catalytic current increase in transition metal oxides under applied magnetic field and the absence of effects related to changes in surface long-range spin order. Moreover, we highlight the need for advanced methodology to separate between effects arising from MR and the long range order at the surface.
- 10 March 2026
- Published by Springer Nature in Research Square
Open AccessMagnetoresistance governs apparent magnetic-field enhancements in water electrolysis
The origin of the recently discovered magnetic-field-induced enhancement of the oxygen evolution reaction (OER) remains controversial, with partly contradictory experimental observations and several competing mechanistic interpretations. Using epitaxial multilayers as well-defined model systems, we disentangle the various effects induced by the applied magnetic field, and establish a quantitative correlation between the observed OER current increments and magnetoresistance (MR) effects. In parallel, operando magneto-optical Kerr effect (MOKE) microscopy was performed to evaluate the frequently proposed role of domain-wall removal. Surprisingly, the measured OER enhancements under magnetic field do not correlate with the appearance or disappearance of domain walls. We find no catalytic current enhancements when MR effects are eliminated. Our work thus reveals the strictly magnetoresistive origin of the observed catalytic current increase in transition metal oxides under applied magnetic field and the absence of effects related to changes in surface long-range spin order. Moreover, we highlight the need for advanced methodology to separate between effects arising from MR and the long range order at the surface.
- Open Access
- 21 November 2025
- Published by Copernicus GmbH in Geoscientific Instrumentation, Methods and Data Systems
- Vol. 14 (2) , 325-334
Improving co-registration of geoscientific imaging datasets with micro-sized marker structures on rock samples
Polished geological samples are frequently used in geoscientific research to investigate the chemical and physical characteristics of rocks. A broad range of imaging techniques is available to analyze such samples, but when combining datasets from multiple imaging techniques, an accurate co-registration of the datasets is often challenging. In this study, we investigate this issue in the context of Micromagnetic Tomography (MMT; De Groot et al., 2018, 2021). MMT combines surface magnetometry data with computed tomography (CT) data to analyze the magnetic state of rock samples. By combining the spatial (position) and dimensional (size) information of the magnetic grains in the samples with their magnetic surface expression, the individual magnetic moments per grain can be determined. This information can be used for paleomagnetic and rock-magnetic studies. Calculating the magnetic moments of the grains strongly depends on the correct co-registration of the two datasets, which proves to be challenging. In this study, we used two test samples for the application of micro-sized marker structures, to further develop the methodology of MMT. The marker structures are applied by microlithography and Nb-sputter coating, which are standard techniques used in the semiconductor industry. We determined that the marker structure application is possible on typical MMT samples. Marker structures larger than ca. 10 µm are clearly visible under the Quantum Diamond Microscope (QDM) used for the surface magnetometry. Given a sufficient marker structure thickness, they can also be observed in the CT scans used for determining the positions and shapes of the magnetic carriers. The marker structures are useful for identifying the orientation and location of the samples during measurements and can be used for scaling and mapping of the two datasets during data processing. Nb-marker structures do not fluoresce under the QDM, which means that no magnetic interference occurs during measurements. The application procedure is time-consuming but is valuable when a sample is lacking natural marker features, it makes the data processing time in MMT significantly faster, and more precise. This method can be useful for MMT, for Quantum Diamond Microscopy in general, and for broader geological applications that require visible anchor points for sample placement or marker structures for the co-registration of multiple datasets.
- 21 November 2025
- Published by Copernicus GmbH in Geoscientific Instrumentation, Methods and Data Systems
- Vol. 14 (2) , 325-334
Open AccessImproving co-registration of geoscientific imaging datasets with micro-sized marker structures on rock samples
Polished geological samples are frequently used in geoscientific research to investigate the chemical and physical characteristics of rocks. A broad range of imaging techniques is available to analyze such samples, but when combining datasets from multiple imaging techniques, an accurate co-registration of the datasets is often challenging. In this study, we investigate this issue in the context of Micromagnetic Tomography (MMT; De Groot et al., 2018, 2021). MMT combines surface magnetometry data with computed tomography (CT) data to analyze the magnetic state of rock samples. By combining the spatial (position) and dimensional (size) information of the magnetic grains in the samples with their magnetic surface expression, the individual magnetic moments per grain can be determined. This information can be used for paleomagnetic and rock-magnetic studies. Calculating the magnetic moments of the grains strongly depends on the correct co-registration of the two datasets, which proves to be challenging. In this study, we used two test samples for the application of micro-sized marker structures, to further develop the methodology of MMT. The marker structures are applied by microlithography and Nb-sputter coating, which are standard techniques used in the semiconductor industry. We determined that the marker structure application is possible on typical MMT samples. Marker structures larger than ca. 10 µm are clearly visible under the Quantum Diamond Microscope (QDM) used for the surface magnetometry. Given a sufficient marker structure thickness, they can also be observed in the CT scans used for determining the positions and shapes of the magnetic carriers. The marker structures are useful for identifying the orientation and location of the samples during measurements and can be used for scaling and mapping of the two datasets during data processing. Nb-marker structures do not fluoresce under the QDM, which means that no magnetic interference occurs during measurements. The application procedure is time-consuming but is valuable when a sample is lacking natural marker features, it makes the data processing time in MMT significantly faster, and more precise. This method can be useful for MMT, for Quantum Diamond Microscopy in general, and for broader geological applications that require visible anchor points for sample placement or marker structures for the co-registration of multiple datasets.
- Open Access
- 4 September 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-16
Reply on RC1
Polished geological samples are frequently used in geoscientific research to investigate the chemical and physical characteristics of rocks. A broad range of imaging techniques is available to analyze such samples, but when combining datasets from multiple imaging techniques, an accurate co-registration of the datasets is often challenging. In this study, we investigate this issue in the context of Micromagnetic Tomography (MMT; De Groot et al., 2018, 2021). MMT combines surface magnetometry with computed tomography (CT) to analyze the magnetic state of rock samples. By combining the spatial and dimensional information of the magnetic grains in the samples with their magnetic surface expression, the individual magnetic moments per grain can be determined. This information can be used for paleomagnetic and rock-magnetic studies. Calculating the magnetic moments of the grains strongly depends on the correct co-registration of the two datasets, which proves to be challenging. In this study, we used two test samples for the application of micro-sized marker structures, to further develop the methodology of MMT. The marker structures are applied by microlithography and Nb-sputter coating, which are standard techniques used in the semiconductor industry. We determined that the marker structure application is possible on typical MMT samples. Marker structures larger than ca. 10 μm are clearly visible under the Quantum Diamond Microscope (QDM) used for the surface magnetometry. Given a sufficient marker structure thickness, they can also be observed in the CT scans used for determining the positions and shapes of the magnetic carriers. The marker structures are useful for identifying the orientation and location of the samples during measurements and can be used for scaling and mapping of the two datasets during data processing. Nb-marker structures do not fluoresce under the QDM, which means that no magnetic interference occurs during measurements. The application procedure is time-consuming but is valuable when a sample is lacking natural marker features, it makes the data processing time in MMT significantly faster, and more precise. This method can be useful for MMT, for Quantum Diamond Microscopy in general, and for broader geological applications that require visible anchor points for sample placement or marker structures for the co-registration of multiple datasets.
- 4 September 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-16
Open AccessReply on RC1
Polished geological samples are frequently used in geoscientific research to investigate the chemical and physical characteristics of rocks. A broad range of imaging techniques is available to analyze such samples, but when combining datasets from multiple imaging techniques, an accurate co-registration of the datasets is often challenging. In this study, we investigate this issue in the context of Micromagnetic Tomography (MMT; De Groot et al., 2018, 2021). MMT combines surface magnetometry with computed tomography (CT) to analyze the magnetic state of rock samples. By combining the spatial and dimensional information of the magnetic grains in the samples with their magnetic surface expression, the individual magnetic moments per grain can be determined. This information can be used for paleomagnetic and rock-magnetic studies. Calculating the magnetic moments of the grains strongly depends on the correct co-registration of the two datasets, which proves to be challenging. In this study, we used two test samples for the application of micro-sized marker structures, to further develop the methodology of MMT. The marker structures are applied by microlithography and Nb-sputter coating, which are standard techniques used in the semiconductor industry. We determined that the marker structure application is possible on typical MMT samples. Marker structures larger than ca. 10 μm are clearly visible under the Quantum Diamond Microscope (QDM) used for the surface magnetometry. Given a sufficient marker structure thickness, they can also be observed in the CT scans used for determining the positions and shapes of the magnetic carriers. The marker structures are useful for identifying the orientation and location of the samples during measurements and can be used for scaling and mapping of the two datasets during data processing. Nb-marker structures do not fluoresce under the QDM, which means that no magnetic interference occurs during measurements. The application procedure is time-consuming but is valuable when a sample is lacking natural marker features, it makes the data processing time in MMT significantly faster, and more precise. This method can be useful for MMT, for Quantum Diamond Microscopy in general, and for broader geological applications that require visible anchor points for sample placement or marker structures for the co-registration of multiple datasets.
- Open Access
- 4 September 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-16
Reply on RC2
Polished geological samples are frequently used in geoscientific research to investigate the chemical and physical characteristics of rocks. A broad range of imaging techniques is available to analyze such samples, but when combining datasets from multiple imaging techniques, an accurate co-registration of the datasets is often challenging. In this study, we investigate this issue in the context of Micromagnetic Tomography (MMT; De Groot et al., 2018, 2021). MMT combines surface magnetometry with computed tomography (CT) to analyze the magnetic state of rock samples. By combining the spatial and dimensional information of the magnetic grains in the samples with their magnetic surface expression, the individual magnetic moments per grain can be determined. This information can be used for paleomagnetic and rock-magnetic studies. Calculating the magnetic moments of the grains strongly depends on the correct co-registration of the two datasets, which proves to be challenging. In this study, we used two test samples for the application of micro-sized marker structures, to further develop the methodology of MMT. The marker structures are applied by microlithography and Nb-sputter coating, which are standard techniques used in the semiconductor industry. We determined that the marker structure application is possible on typical MMT samples. Marker structures larger than ca. 10 μm are clearly visible under the Quantum Diamond Microscope (QDM) used for the surface magnetometry. Given a sufficient marker structure thickness, they can also be observed in the CT scans used for determining the positions and shapes of the magnetic carriers. The marker structures are useful for identifying the orientation and location of the samples during measurements and can be used for scaling and mapping of the two datasets during data processing. Nb-marker structures do not fluoresce under the QDM, which means that no magnetic interference occurs during measurements. The application procedure is time-consuming but is valuable when a sample is lacking natural marker features, it makes the data processing time in MMT significantly faster, and more precise. This method can be useful for MMT, for Quantum Diamond Microscopy in general, and for broader geological applications that require visible anchor points for sample placement or marker structures for the co-registration of multiple datasets.
- 4 September 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-16
Open AccessReply on RC2
Polished geological samples are frequently used in geoscientific research to investigate the chemical and physical characteristics of rocks. A broad range of imaging techniques is available to analyze such samples, but when combining datasets from multiple imaging techniques, an accurate co-registration of the datasets is often challenging. In this study, we investigate this issue in the context of Micromagnetic Tomography (MMT; De Groot et al., 2018, 2021). MMT combines surface magnetometry with computed tomography (CT) to analyze the magnetic state of rock samples. By combining the spatial and dimensional information of the magnetic grains in the samples with their magnetic surface expression, the individual magnetic moments per grain can be determined. This information can be used for paleomagnetic and rock-magnetic studies. Calculating the magnetic moments of the grains strongly depends on the correct co-registration of the two datasets, which proves to be challenging. In this study, we used two test samples for the application of micro-sized marker structures, to further develop the methodology of MMT. The marker structures are applied by microlithography and Nb-sputter coating, which are standard techniques used in the semiconductor industry. We determined that the marker structure application is possible on typical MMT samples. Marker structures larger than ca. 10 μm are clearly visible under the Quantum Diamond Microscope (QDM) used for the surface magnetometry. Given a sufficient marker structure thickness, they can also be observed in the CT scans used for determining the positions and shapes of the magnetic carriers. The marker structures are useful for identifying the orientation and location of the samples during measurements and can be used for scaling and mapping of the two datasets during data processing. Nb-marker structures do not fluoresce under the QDM, which means that no magnetic interference occurs during measurements. The application procedure is time-consuming but is valuable when a sample is lacking natural marker features, it makes the data processing time in MMT significantly faster, and more precise. This method can be useful for MMT, for Quantum Diamond Microscopy in general, and for broader geological applications that require visible anchor points for sample placement or marker structures for the co-registration of multiple datasets.
- Open Access
- 1 July 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-16
Comment on egusphere-2025-1692
Polished geological samples are frequently used in geoscientific research to investigate the chemical and physical characteristics of rocks. A broad range of imaging techniques is available to analyze such samples, but when combining datasets from multiple imaging techniques, an accurate co-registration of the datasets is often challenging. In this study, we investigate this issue in the context of Micromagnetic Tomography (MMT; De Groot et al., 2018, 2021). MMT combines surface magnetometry with computed tomography (CT) to analyze the magnetic state of rock samples. By combining the spatial and dimensional information of the magnetic grains in the samples with their magnetic surface expression, the individual magnetic moments per grain can be determined. This information can be used for paleomagnetic and rock-magnetic studies. Calculating the magnetic moments of the grains strongly depends on the correct co-registration of the two datasets, which proves to be challenging. In this study, we used two test samples for the application of micro-sized marker structures, to further develop the methodology of MMT. The marker structures are applied by microlithography and Nb-sputter coating, which are standard techniques used in the semiconductor industry. We determined that the marker structure application is possible on typical MMT samples. Marker structures larger than ca. 10 μm are clearly visible under the Quantum Diamond Microscope (QDM) used for the surface magnetometry. Given a sufficient marker structure thickness, they can also be observed in the CT scans used for determining the positions and shapes of the magnetic carriers. The marker structures are useful for identifying the orientation and location of the samples during measurements and can be used for scaling and mapping of the two datasets during data processing. Nb-marker structures do not fluoresce under the QDM, which means that no magnetic interference occurs during measurements. The application procedure is time-consuming but is valuable when a sample is lacking natural marker features, it makes the data processing time in MMT significantly faster, and more precise. This method can be useful for MMT, for Quantum Diamond Microscopy in general, and for broader geological applications that require visible anchor points for sample placement or marker structures for the co-registration of multiple datasets.
- 1 July 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-16
Open AccessComment on egusphere-2025-1692
Polished geological samples are frequently used in geoscientific research to investigate the chemical and physical characteristics of rocks. A broad range of imaging techniques is available to analyze such samples, but when combining datasets from multiple imaging techniques, an accurate co-registration of the datasets is often challenging. In this study, we investigate this issue in the context of Micromagnetic Tomography (MMT; De Groot et al., 2018, 2021). MMT combines surface magnetometry with computed tomography (CT) to analyze the magnetic state of rock samples. By combining the spatial and dimensional information of the magnetic grains in the samples with their magnetic surface expression, the individual magnetic moments per grain can be determined. This information can be used for paleomagnetic and rock-magnetic studies. Calculating the magnetic moments of the grains strongly depends on the correct co-registration of the two datasets, which proves to be challenging. In this study, we used two test samples for the application of micro-sized marker structures, to further develop the methodology of MMT. The marker structures are applied by microlithography and Nb-sputter coating, which are standard techniques used in the semiconductor industry. We determined that the marker structure application is possible on typical MMT samples. Marker structures larger than ca. 10 μm are clearly visible under the Quantum Diamond Microscope (QDM) used for the surface magnetometry. Given a sufficient marker structure thickness, they can also be observed in the CT scans used for determining the positions and shapes of the magnetic carriers. The marker structures are useful for identifying the orientation and location of the samples during measurements and can be used for scaling and mapping of the two datasets during data processing. Nb-marker structures do not fluoresce under the QDM, which means that no magnetic interference occurs during measurements. The application procedure is time-consuming but is valuable when a sample is lacking natural marker features, it makes the data processing time in MMT significantly faster, and more precise. This method can be useful for MMT, for Quantum Diamond Microscopy in general, and for broader geological applications that require visible anchor points for sample placement or marker structures for the co-registration of multiple datasets.
- Open Access
- 27 June 2025
- Published by Copernicus GmbH in EGUsphere
- Vol. 2025, 1-16
Improving co-registration of geoscientific imaging datasets with micro-sized marker structures on rock samples
Polished geological samples are frequently used in geoscientific research to investigate the chemical and physical characteristics of rocks. A broad range of imaging techniques is available to analyze such samples, but when combining datasets from multiple imaging techniques, an accurate co-registration of the datasets is often challenging. In this study, we investigate this issue in the context of Micromagnetic Tomography (MMT; De Groot et al., 2018, 2021). MMT combines surface magnetometry with computed tomography (CT) to analyze the magnetic state of rock samples. By combining the spatial and dimensional information of the magnetic grains in the samples with their magnetic surface expression, the individual magnetic moments per grain can be determined. This information can be used for paleomagnetic and rock-magnetic studies. Calculating the magnetic moments of the grains strongly depends on the correct co-registration of the two datasets, which proves to be challenging. In this study, we used two test samples for the application of micro-sized marker structures, to further develop the methodology of MMT. The marker structures are applied by microlithography and Nb-sputter coating, which are standard techniques used in the semiconductor industry. We determined that the marker structure application is possible on typical MMT samples. Marker structures larger than ca. 10 μm are clearly visible under the Quantum Diamond Microscope (QDM) used for the surface magnetometry. Given a sufficient marker structure thickness, they can also be observed in the CT scans used for determining the positions and shapes of the magnetic carriers. The marker structures are useful for identifying the orientation and location of the samples during measurements and can be used for scaling and mapping of the two datasets during data processing. Nb-marker structures do not fluoresce under the QDM, which means that no magnetic interference occurs during measurements. The application procedure is time-consuming but is valuable when a sample is lacking natural marker features, it makes the data processing time in MMT significantly faster, and more precise. This method can be useful for MMT, for Quantum Diamond Microscopy in general, and for broader geological applications that require visible anchor points for sample placement or marker structures for the co-registration of multiple datasets.
- 27 June 2025
- Published by Copernicus GmbH in EGUsphere
- Vol. 2025, 1-16
Open AccessImproving co-registration of geoscientific imaging datasets with micro-sized marker structures on rock samples
Polished geological samples are frequently used in geoscientific research to investigate the chemical and physical characteristics of rocks. A broad range of imaging techniques is available to analyze such samples, but when combining datasets from multiple imaging techniques, an accurate co-registration of the datasets is often challenging. In this study, we investigate this issue in the context of Micromagnetic Tomography (MMT; De Groot et al., 2018, 2021). MMT combines surface magnetometry with computed tomography (CT) to analyze the magnetic state of rock samples. By combining the spatial and dimensional information of the magnetic grains in the samples with their magnetic surface expression, the individual magnetic moments per grain can be determined. This information can be used for paleomagnetic and rock-magnetic studies. Calculating the magnetic moments of the grains strongly depends on the correct co-registration of the two datasets, which proves to be challenging. In this study, we used two test samples for the application of micro-sized marker structures, to further develop the methodology of MMT. The marker structures are applied by microlithography and Nb-sputter coating, which are standard techniques used in the semiconductor industry. We determined that the marker structure application is possible on typical MMT samples. Marker structures larger than ca. 10 μm are clearly visible under the Quantum Diamond Microscope (QDM) used for the surface magnetometry. Given a sufficient marker structure thickness, they can also be observed in the CT scans used for determining the positions and shapes of the magnetic carriers. The marker structures are useful for identifying the orientation and location of the samples during measurements and can be used for scaling and mapping of the two datasets during data processing. Nb-marker structures do not fluoresce under the QDM, which means that no magnetic interference occurs during measurements. The application procedure is time-consuming but is valuable when a sample is lacking natural marker features, it makes the data processing time in MMT significantly faster, and more precise. This method can be useful for MMT, for Quantum Diamond Microscopy in general, and for broader geological applications that require visible anchor points for sample placement or marker structures for the co-registration of multiple datasets.
- 20 June 2025
- Published by American Physical Society (APS) in Physical Review B
- Vol. 112 (4)
Non-Ohmic behavior in (Bi Sb ) Te by Joule heating- 20 June 2025
- Published by American Physical Society (APS) in Physical Review B
- Vol. 112 (4)
Non-Ohmic behavior in (Bi Sb ) Te by Joule heating- Open Access
- 31 March 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (14) , 21110-21121
Revealing the Intrinsic Oxygen Evolution Reaction Activity of Perovskite Oxides across Conductivity Ranges Using Thin Film Model Systems
The development of efficient electrocatalysts in water electrolysis is essential to decrease the high overpotentials, especially at the anode where the oxygen evolution reaction (OER) takes place. However, establishing catalyst design rules to find the optimal electrocatalysts is a substantial challenge. Complex oxides, which are often considered as suitable OER catalysts, can exhibit vastly different conductivity values, making it challenging to separate intrinsic catalytic activities from internal transport limitations. Here, we systematically decouple the limitations arising from electrical bulk resistivity, contact resistances to the catalyst support, and intrinsic OER catalytic properties using a systematic epitaxial thin film model catalyst approach. We investigate the influence of the resistivity of the three perovskite oxides LaNiO3-δ (3.7 × 10-4 Ω cm), La0.67Sr0.33MnO3-δ (2.7 × 10-3 Ω cm), and La0.6Ca0.4FeO3-δ (0.57 Ω·cm) on the observed catalytic activity. We tuned the electron pathway through the catalyst bulk by comparing insulating and conductive substrates. The conducting substrate reduces the electron pathway through the catalyst bulk from the millimeter to nanometer length scale. As we show, for the large electron pathways, the observed catalytic activity scales with resistivity because of a highly inhomogeneous lateral current density distribution. At the same time, even on the conducting substrate (Nb-doped SrTiO3), large contact resistances occur that limit the determination of intrinsic catalytic properties. By inserting interfacial dipole layers (in this case, LaAlO3) we lifted these interface resistances, allowing us to reveal the intrinsic catalytic properties of all examined catalysts. We find that La0.6Ca0.4FeO3-δ and LaNiO3-δ exhibit a similar intrinsic overpotential of 0.36 V at 0.1 mA/cm2, while their resistivities differ by 3 orders of magnitude. This finding shows that optimizing the electron pathway of the OER catalyst can lead the way to find new structure-activity relationships and to identify high-activity catalysts even if the electronic resistance is high.
- 31 March 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (14) , 21110-21121
Open AccessRevealing the Intrinsic Oxygen Evolution Reaction Activity of Perovskite Oxides across Conductivity Ranges Using Thin Film Model Systems
The development of efficient electrocatalysts in water electrolysis is essential to decrease the high overpotentials, especially at the anode where the oxygen evolution reaction (OER) takes place. However, establishing catalyst design rules to find the optimal electrocatalysts is a substantial challenge. Complex oxides, which are often considered as suitable OER catalysts, can exhibit vastly different conductivity values, making it challenging to separate intrinsic catalytic activities from internal transport limitations. Here, we systematically decouple the limitations arising from electrical bulk resistivity, contact resistances to the catalyst support, and intrinsic OER catalytic properties using a systematic epitaxial thin film model catalyst approach. We investigate the influence of the resistivity of the three perovskite oxides LaNiO3-δ (3.7 × 10-4 Ω cm), La0.67Sr0.33MnO3-δ (2.7 × 10-3 Ω cm), and La0.6Ca0.4FeO3-δ (0.57 Ω·cm) on the observed catalytic activity. We tuned the electron pathway through the catalyst bulk by comparing insulating and conductive substrates. The conducting substrate reduces the electron pathway through the catalyst bulk from the millimeter to nanometer length scale. As we show, for the large electron pathways, the observed catalytic activity scales with resistivity because of a highly inhomogeneous lateral current density distribution. At the same time, even on the conducting substrate (Nb-doped SrTiO3), large contact resistances occur that limit the determination of intrinsic catalytic properties. By inserting interfacial dipole layers (in this case, LaAlO3) we lifted these interface resistances, allowing us to reveal the intrinsic catalytic properties of all examined catalysts. We find that La0.6Ca0.4FeO3-δ and LaNiO3-δ exhibit a similar intrinsic overpotential of 0.36 V at 0.1 mA/cm2, while their resistivities differ by 3 orders of magnitude. This finding shows that optimizing the electron pathway of the OER catalyst can lead the way to find new structure-activity relationships and to identify high-activity catalysts even if the electronic resistance is high.