David Vera Anaya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
David Vera Anaya has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Lim Wei Yap
The University of Sydney
2 shared publications - Wenlong Cheng
The University of Sydney
2 shared publications Yan Lu
School of Biomedical Engineering, Faculty of Engineering, University of Sydney, Darlington, New South Wales 2008, Australia
2 shared publications- Abdulla Al Mamun
Department of Computer Science and Engineering Hajee Mohammad Danesh Science and Technology University Dinajpur Bangladesh hstu.ac.bd
1 shared publication - Allison Thomas
Department of Obstetrics and Gynaecology, Monash University, Clayton, Victoria 3168, Australia
1 shared publication - Arie Levin
Department of Chemical and Biological Engineering, Faculty of Engineering, Monash University, Clayton, Victoria 3168, Australia
1 shared publication
Latest Publications
- Open Access
- 28 November 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (48) , eady2661
An intelligent, compact wearable pressure-strain combo sensor system for continuous fetal movement monitoring
Continuous fetal movement monitoring in late pregnancy may improve fetal wellbeing and pregnancy outcomes. While fetal movements can be visualized with ultrasound, it is intermittent and limited to clinical settings. Inertial measurement units may enable at-home fetal monitoring but usually require a large-footprint, multisensor design. Here, we report smart, compact wearable pressure-strain combo sensors continuously monitoring fetal movements through maternal abdominal skin motions. In the 2D and 3D artificial abdomen systems, our octagonal-shaped gold nanowire–based strain sensor served as an isotropic sensor, enabling omnidirectional simulated “kicking load” detection within an area of ~77 (2D) and ~217 cm 2 (3D), while an interdigitated electrode–based pressure sensor showed highly sensitive localized load detection. Building upon these findings, we designed compact pressure- and strain-sensing integrated Band-Aids and tested on 59 pregnant women. We developed machine learning models to distinguish fetal from nonfetal movements with >90% accuracy in ultrasound-based validation studies. This AI-powered, Band-Aid–like sensing system offers potential as a compact, comfortable, and accurate continuous out-of-hospital fetal movement monitoring technology.
- 28 November 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (48) , eady2661
Open AccessAn intelligent, compact wearable pressure-strain combo sensor system for continuous fetal movement monitoring
Continuous fetal movement monitoring in late pregnancy may improve fetal wellbeing and pregnancy outcomes. While fetal movements can be visualized with ultrasound, it is intermittent and limited to clinical settings. Inertial measurement units may enable at-home fetal monitoring but usually require a large-footprint, multisensor design. Here, we report smart, compact wearable pressure-strain combo sensors continuously monitoring fetal movements through maternal abdominal skin motions. In the 2D and 3D artificial abdomen systems, our octagonal-shaped gold nanowire–based strain sensor served as an isotropic sensor, enabling omnidirectional simulated “kicking load” detection within an area of ~77 (2D) and ~217 cm 2 (3D), while an interdigitated electrode–based pressure sensor showed highly sensitive localized load detection. Building upon these findings, we designed compact pressure- and strain-sensing integrated Band-Aids and tested on 59 pregnant women. We developed machine learning models to distinguish fetal from nonfetal movements with >90% accuracy in ultrasound-based validation studies. This AI-powered, Band-Aid–like sensing system offers potential as a compact, comfortable, and accurate continuous out-of-hospital fetal movement monitoring technology.
- 19 September 2024
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 9 (10) , 5414-5424
Gold Nanowire Sponge Electrochemistry for Permeable Wearable Sweat Analysis Comfortably and Wirelessly
Electrochemistry-based wearable and wireless sweat analysis is emerging as a promising noninvasive method for real-time health monitoring by tracking chemical and biological markers without the need for invasive blood sampling. It offers the potential to remotely monitor human sweat conditions in relation to metabolic health, stress, and electrolyte balance, which have implications for athletes, patients with chronic conditions, and individuals for the early detection and management of health issues. The state-of-the-art mainstream technology is dominated by the concept of a wearable microfluidic chip, typically based on elastomeric PDMS. While outstanding sensing performance can be realized, the design suffers from the poor permeability of PDMS, which could cause skin redness or irritation. Here, we introduce an omnidirectionally permeable, deformable, and wearable sweat analysis system based on gold nanowire sponges. We demonstrate the concept of all-in-one soft sponge electrochemistry, where the working, reference, and counter electrodes and electrolytes are all integrated within the sponge matrix. The intrinsic porosity of sponge in conjunction with vertically aligned gold nanowire electrodes gives rise to a high electrochemically active surface area of ∼67 cm2. Remarkably, this all-in-one sponge-based electrochemical system exhibited stable performance under a pressure of 10 kPa and 300% omnidirectional strain. The gold sponge biosensing electrodes could be sandwiched between two biocompatible sweat pads, which can serve as natural sweat collection and outflow layers. This naturally biocompatible and permeable platform can be integrated with wireless communication circuits, leading to a wireless sweat analysis system for the real-time monitoring of glucose, lactate, and pH during exercise.
- 19 September 2024
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 9 (10) , 5414-5424
Gold Nanowire Sponge Electrochemistry for Permeable Wearable Sweat Analysis Comfortably and Wirelessly
Electrochemistry-based wearable and wireless sweat analysis is emerging as a promising noninvasive method for real-time health monitoring by tracking chemical and biological markers without the need for invasive blood sampling. It offers the potential to remotely monitor human sweat conditions in relation to metabolic health, stress, and electrolyte balance, which have implications for athletes, patients with chronic conditions, and individuals for the early detection and management of health issues. The state-of-the-art mainstream technology is dominated by the concept of a wearable microfluidic chip, typically based on elastomeric PDMS. While outstanding sensing performance can be realized, the design suffers from the poor permeability of PDMS, which could cause skin redness or irritation. Here, we introduce an omnidirectionally permeable, deformable, and wearable sweat analysis system based on gold nanowire sponges. We demonstrate the concept of all-in-one soft sponge electrochemistry, where the working, reference, and counter electrodes and electrolytes are all integrated within the sponge matrix. The intrinsic porosity of sponge in conjunction with vertically aligned gold nanowire electrodes gives rise to a high electrochemically active surface area of ∼67 cm2. Remarkably, this all-in-one sponge-based electrochemical system exhibited stable performance under a pressure of 10 kPa and 300% omnidirectional strain. The gold sponge biosensing electrodes could be sandwiched between two biocompatible sweat pads, which can serve as natural sweat collection and outflow layers. This naturally biocompatible and permeable platform can be integrated with wireless communication circuits, leading to a wireless sweat analysis system for the real-time monitoring of glucose, lactate, and pH during exercise.
- Open Access
Landmark-Assisted Compensation of User’s Body Shadowing on RSSI for Improved Indoor Localisation with Chest-Mounted Wearable Device
Nowadays, location awareness becomes the key to numerous Internet of Things (IoT) applications. Among the various methods for indoor localisation, received signal strength indicator (RSSI)-based fingerprinting attracts massive attention. However, the RSSI fingerprinting method is susceptible to lower accuracies because of the disturbance triggered by various factors from the indoors that influence the link quality of radio signals. Localisation using body-mounted wearable devices introduces an additional source of error when calculating the RSSI, leading to the deterioration of localisation performance. The broad aim of this study is to mitigate the user’s body shadowing effect on RSSI to improve localisation accuracy. Firstly, this study examines the effect of the user’s body on RSSI. Then, an angle estimation method is proposed by leveraging the concept of landmark. For precise identification of landmarks, an inertial measurement unit (IMU)-aided decision tree-based motion mode classifier is implemented. After that, a compensation model is proposed to correct the RSSI. Finally, the unknown location is estimated using the nearest neighbour method. Results demonstrated that the proposed system can significantly improve the localisation accuracy, where a median localisation accuracy of 1.46 m is achieved after compensating the body effect, which is 2.68 m before the compensation using the classical K-nearest neighbour method. Moreover, the proposed system noticeably outperformed others when comparing its performance with two other related works. The median accuracy is further improved to 0.74 m by applying a proposed weighted K-nearest neighbour algorithm.
Open AccessLandmark-Assisted Compensation of User’s Body Shadowing on RSSI for Improved Indoor Localisation with Chest-Mounted Wearable Device
Nowadays, location awareness becomes the key to numerous Internet of Things (IoT) applications. Among the various methods for indoor localisation, received signal strength indicator (RSSI)-based fingerprinting attracts massive attention. However, the RSSI fingerprinting method is susceptible to lower accuracies because of the disturbance triggered by various factors from the indoors that influence the link quality of radio signals. Localisation using body-mounted wearable devices introduces an additional source of error when calculating the RSSI, leading to the deterioration of localisation performance. The broad aim of this study is to mitigate the user’s body shadowing effect on RSSI to improve localisation accuracy. Firstly, this study examines the effect of the user’s body on RSSI. Then, an angle estimation method is proposed by leveraging the concept of landmark. For precise identification of landmarks, an inertial measurement unit (IMU)-aided decision tree-based motion mode classifier is implemented. After that, a compensation model is proposed to correct the RSSI. Finally, the unknown location is estimated using the nearest neighbour method. Results demonstrated that the proposed system can significantly improve the localisation accuracy, where a median localisation accuracy of 1.46 m is achieved after compensating the body effect, which is 2.68 m before the compensation using the classical K-nearest neighbour method. Moreover, the proposed system noticeably outperformed others when comparing its performance with two other related works. The median accuracy is further improved to 0.74 m by applying a proposed weighted K-nearest neighbour algorithm.