You Jeong Jeong

You Jeong Jeong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


You Jeong Jeong has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Tong In Oh

    Department of Biomedical Engineering, College of Medicine, Kyung Hee University, Seoul 02447, Republic of Korea

    4 shared publications
  • Dong Choon Park

    Department of Obstetrics and Gynecology, St. Vincent’s Hospital, College of Medicine, The Catholic University of Korea, Suwon 16247, Republic of Korea

    2 shared publications
  • Hongdoo Kim

    Department of Advanced Materials Engineering for Information and Electronics, College of Engineering, Kyung Hee University, Yongin-si, Republic of Korea

    1 shared publication
  • Jin Won Mok

    Department of Biomedical Engineering, Kyung Hee University, Seoul, Republic of Korea

    1 shared publication
  • Ju-Young Moon

    Division of Nephrology, Department of Internal Medicine, Kyung Hee University Hospital at Gangdong, Seoul, Republic of Korea

    1 shared publication
  • Kap Jin Kim

    Department of Advanced Materials Engineering for Information and Electronics, College of Engineering, Kyung Hee University, Yongin-si, Republic of Korea

    1 shared publication

Latest Publications

  • Open Access

    Index for prevention and management of intradialytic hypotension with noninvasive hemodynamic monitoring based on electrical impedance tomography

    by Yoosun Joo, You Jeong Jeong, Jin Won Mok, Youngyoon Moon, Su-Woong Jung, Yang Gyun Kim, Sangho Lee, Tong In Oh, Ju-Young Moon

  • Open Access

    Electrospun Rubber Nanofiber Web-Based Dry Electrodes for Biopotential Monitoring

    by Mohammad Shamim Reza, Lu Jin, You Jeong Jeong, Tong In Oh, Hongdoo Kim, Kap Jin Kim

    This study aims to find base materials for dry electrode fabrication with high accuracy and without reducing electrode performance for long-term bioelectric potential monitoring after electroless silver plating. Most applications of dry electrodes that have been developed in the past few decades are restricted by low accuracy compared to commercial Ag/AgCl gel electrodes, as in our previous study of PVDF-based dry electrodes. In a recent study, however, nanoweb-based chlorinated polyisoprene (CPI) and poly(styrene-b-butadiene-b-styrene) (SBS) rubber were selected as promising candidates due to their excellent elastic properties, as well as their nanofibril nature, which may improve electrode durability and skin contact. The electroless silver plating technique was employed to coat the nanofiber web with silver, and silver nanoweb(AgNW)-based dry electrodes were fabricated. The key electrode properties (contact impedance, step response, and noise characteristics) for AgNW dry electrodes were investigated thoroughly using agar phantoms. The dry electrodes were subsequently tested on human subjects to establish their realistic performance in terms of ECG, EMG monitoring, and electrical impedance tomography (EIT) measurements. The experimental results demonstrated that the AgNW dry electrodes, particularly the SBS-AgNW dry electrodes, performed similarly to commercial Ag/AgCl gel electrodes and were outperformed in terms of long-term stability.


  • Open Access

    Tissue Characterization Using an Electrical Bioimpedance Spectroscopy-Based Multi-Electrode Probe to Screen for Cervical Intraepithelial Neoplasia

    by Tong In Oh, Min Ji Kang, You Jeong Jeong, Tingting Zhang, Seung Geun Yeo, Dong Choon Park

    The successful management of cervical intraepithelial neoplasia (CIN) with proper screening and treatment methods could prevent cervical cancer progression. We propose a bioimpedance spectroscopic measurement device and a multi-electrode probe as an independent screening tool for CIN. To evaluate the performance of this screening method, we enrolled 123 patients, including 69 patients with suspected CIN and 54 control patients without cervical dysplasia who underwent a hysterectomy for benign disease (non-CIN). Following conization, the electrical properties of the excised cervical tissue were characterized using an electrical bioimpedance spectroscopy-based multi-electrode probe. Twenty-eight multifrequency voltages were collected through the two concentric array electrodes via a sensitivity-optimized measurement protocol based on an electrical energy concentration method. The electrical properties of the CIN and non-CIN groups were compared with the results of the pathology reports. Reconstructed resistivity tended to decrease in the CIN and non-CIN groups as frequency increased. Reconstructed resistivity from 625 Hz to 50 kHz differed significantly between the CIN and non-CIN groups (p < 0.001). Using 100 kHz as the reference, the difference between the CIN and non-CIN groups was significant. Based on the difference in reconstructed resistivity between 100 kHz and the other frequencies, this method had a sensitivity of 94.3%, a specificity of 84%, and an accuracy of 90% in CIN screening. The feasibility of noninvasive CIN screening was confirmed through the difference in the frequency spectra evaluated in the excised tissue using the electrical bioimpedance spectroscopy-based multi-electrode screening probe.


  • Open Access

    Performance Evaluation of Multiple Electrodes Based Electrical Impedance Spectroscopic Probe for Screening of Cervical Intraepithelial Neoplasia

    by Tingting Zhang, Youjeong Jeong, Dongchoon Park, Tongin Oh

    As regular cervical cancer screening becomes more common, the detection of cervical intraepithelial neoplasia (CIN) is increasing. We proposed a noninvasive and low-cost multi-channel electrical impedance spectroscopy (EIS) and probe with multiple active electrodes for screening CIN. Compared with four-electrode probes for impedance spectroscopy, the multiple active electrodes facilitated more flexible combination of current injection and voltage measurement, which allowed well-designed measurement protocols for focused sensitivity underneath the large size of the probe. Furthermore, the multiple active electrodes reduced the negative effects of the cabling between the system and probe inserted into the cervix. After presenting the basic performance, the EIS probe was tested by three different experimental phantoms using four different materials of electrical properties. The corresponding experimental results were presented to prove the functionality of the EIS probe and characterize the electrical properties at a wide range of frequencies from 0.625 to 100 kHz. It had high sensitivity underneath the surface of the probe and a rapidly decreased outer. Furthermore, we verified the frequency-dependent impedance changes using the giant vesicle phantoms with different amounts of extra- and intra-fluids separated by the insulating membranes. This study facilitates the feasibility into clinical practice for identifying CIN in the future.