William F. Blakely
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
William F. Blakely has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
David L. Bolduc
Scientific Research Department, Armed Forces Radiobiology Research Institute
3 shared publicationsFrancis Hérodin
Effets Biologiques des Rayonnements Département, Institut de Recherche Biomédicale des Armées
2 shared publications- Lalitha Kurada
Biodosimetry Program, Scientific Research Department, Armed Forces Radiobiology Research Institute, Uniformed Services University of the Health Sciences
2 shared publications Matthias Port
Bundeswehr Institute of Radiobiology affiliated to the University of Ulm, Munich, Germany
2 shared publicationsMichael Abend
Bundeswehr Institute of Radiobiology affiliated to the University of Ulm, Munich, Germany
2 shared publicationsAlexander Romanyukha
Naval Dosimetry Center, Bethesda, MD 20889, USA
1 shared publication
Latest Publications
- 7 August 2026
- Published by Taylor & Francis in International Journal of Radiation Biology
- p. 1-9
Early-phase dose and H-ARS severity-based response category algorithms using hematological biomarkers in baboon gamma and mixed-field neutron/gamma radiation models
Risk from accidental, medical, or intentional use of ionizing radiation necessitates a robust medical-preparedness response capability (Al-Ibraheem et al. 2024). National defense plans and global t...
- 7 August 2026
- Published by Taylor & Francis in International Journal of Radiation Biology
- p. 1-9
Early-phase dose and H-ARS severity-based response category algorithms using hematological biomarkers in baboon gamma and mixed-field neutron/gamma radiation models
Risk from accidental, medical, or intentional use of ionizing radiation necessitates a robust medical-preparedness response capability (Al-Ibraheem et al. 2024). National defense plans and global t...
- 1 May 2024
- Published by Radiation Research Society in Radiation Research
- Vol. 201 (5) , 406-417
Natural-history Characterization of a Murine Partial-body Irradiation Model System: Establishment of a Multiple-Parameter Based GI-ARS Severity-Scoring System
The purpose of this investigation was to characterize the natural history of a murine total-abdominal-irradiation exposure model to measure gastrointestinal acute radiation injury. Male CD2F1 mice at 12 to 15 weeks old received total-abdominal irradiation using 4-MV linear accelerator X-rays doses of 0, 11, 13.5, 15, 15.75 and 16.5 Gy (2.75 Gy/min). Daily cage-side (i.e., in the animal housing room) observations of clinical signs and symptoms including body weights on all animals were measured up to 10 days after exposure. Jejunum tissues from cohorts of mice were collected at 1, 3, 7 and 10 days after exposure and radiation injury was assessed by histopathological analyses. Results showed time- and dose-dependent loss of body weight [for example at 7 days: 0.66 (±0.80) % loss for 0 Gy, 6.40 (±0.76) % loss at 11 Gy, 9.43 (±2.06) % loss at 13.5 Gy, 23.53 (± 1.91) % loss at 15 Gy, 29.97 (±1.16) % loss at 15.75 Gy, and 31.79 (±0.76) % loss at 16.5 Gy]. Negligible clinical signs and symptoms, except body weight changes, of radiation injury were observed up to 10 days after irradiation with doses of 11 to 15 Gy. Progressive increases in the severity of clinical signs and symptoms were found after irradiation with doses >15 Gy. Jejunum histology showed a progressive dose-dependent increase in injury. For example, at 7 days postirradiation, the percent of crypts, compared to controls, decreased to 82.3 (±9.5), 69.2 (±12.3), 45.4 (±11.9), 18.0 (±3.4), and 11.5 (± 1.8) with increases in doses from 11 to 16.5 Gy. A mucosal injury scoring system was used that mainly focused on changes in villus morphology damage (i.e., subepithelial spaces near the tips of the villi with capillary congestion, significant epithelial lifting along the length of the villi with a few denuded villus tips). Peak levels of total-abdominal irradiation induced effects on the mucosal injury score were seen 7 days after irradiation for doses ≥15 Gy, with a trend to show a decline after 7 days. A murine multiple-parameter gastrointestinal acute-radiation syndrome severity-scoring system was established based on clinical signs and symptoms that included measures of appearance (i.e., hunched and/or fluffed fur), respiratory rate, general (i.e., decreased mobility) and provoked behavior (i.e., subdued response to stimulation), weight loss, and feces/diarrhea score combined with jejunum mucosal-injury grade score. In summary, the natural-history radio-response for murine partial-body irradiation exposures is important for establishing a well-characterized radiation model system; here we established a multiple-parameter gastrointestinal acute-radiation syndrome severity-scoring system that provides a radiation injury gastrointestinal tissue-based assessment utility.
- 1 May 2024
- Published by Radiation Research Society in Radiation Research
- Vol. 201 (5) , 406-417
Natural-history Characterization of a Murine Partial-body Irradiation Model System: Establishment of a Multiple-Parameter Based GI-ARS Severity-Scoring System
The purpose of this investigation was to characterize the natural history of a murine total-abdominal-irradiation exposure model to measure gastrointestinal acute radiation injury. Male CD2F1 mice at 12 to 15 weeks old received total-abdominal irradiation using 4-MV linear accelerator X-rays doses of 0, 11, 13.5, 15, 15.75 and 16.5 Gy (2.75 Gy/min). Daily cage-side (i.e., in the animal housing room) observations of clinical signs and symptoms including body weights on all animals were measured up to 10 days after exposure. Jejunum tissues from cohorts of mice were collected at 1, 3, 7 and 10 days after exposure and radiation injury was assessed by histopathological analyses. Results showed time- and dose-dependent loss of body weight [for example at 7 days: 0.66 (±0.80) % loss for 0 Gy, 6.40 (±0.76) % loss at 11 Gy, 9.43 (±2.06) % loss at 13.5 Gy, 23.53 (± 1.91) % loss at 15 Gy, 29.97 (±1.16) % loss at 15.75 Gy, and 31.79 (±0.76) % loss at 16.5 Gy]. Negligible clinical signs and symptoms, except body weight changes, of radiation injury were observed up to 10 days after irradiation with doses of 11 to 15 Gy. Progressive increases in the severity of clinical signs and symptoms were found after irradiation with doses >15 Gy. Jejunum histology showed a progressive dose-dependent increase in injury. For example, at 7 days postirradiation, the percent of crypts, compared to controls, decreased to 82.3 (±9.5), 69.2 (±12.3), 45.4 (±11.9), 18.0 (±3.4), and 11.5 (± 1.8) with increases in doses from 11 to 16.5 Gy. A mucosal injury scoring system was used that mainly focused on changes in villus morphology damage (i.e., subepithelial spaces near the tips of the villi with capillary congestion, significant epithelial lifting along the length of the villi with a few denuded villus tips). Peak levels of total-abdominal irradiation induced effects on the mucosal injury score were seen 7 days after irradiation for doses ≥15 Gy, with a trend to show a decline after 7 days. A murine multiple-parameter gastrointestinal acute-radiation syndrome severity-scoring system was established based on clinical signs and symptoms that included measures of appearance (i.e., hunched and/or fluffed fur), respiratory rate, general (i.e., decreased mobility) and provoked behavior (i.e., subdued response to stimulation), weight loss, and feces/diarrhea score combined with jejunum mucosal-injury grade score. In summary, the natural-history radio-response for murine partial-body irradiation exposures is important for establishing a well-characterized radiation model system; here we established a multiple-parameter gastrointestinal acute-radiation syndrome severity-scoring system that provides a radiation injury gastrointestinal tissue-based assessment utility.
- Open Access
- 19 January 2024
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 200 (5) , 448-458
Optimizing chemical-induced premature chromosome condensation assay for rapid estimation of high-radiation doses
In the event of exposure to high doses of radiation, prompt dose estimation is crucial for selecting appropriate treatment modalities, such as cytokine therapy or stem cell transplantation. The chemical-induced premature chromosome condensation (PCC) method offers a simple approach for such dose estimation with significant radiation exposure, but its 48-h incubation time poses challenges for early dose assessment. In this study, we optimized the chemical-induced PCC assay for more rapid dose assessment. A sufficient number of PCC and G2/M-PCC cells were obtained after 40 h of culture for irradiated human peripheral blood up to 20 Gy. By adding caffeine (final concentration of 1 mM) at 34 h from the start of culture, G2/M-PCC index increased by 1.4-fold in 10 Gy cultures. There was also no significant difference in the G2/M-PCC ring frequency induced for doses 0 to 15 Gy between our 40-h caffeine-supplemented chemical-induced PCC method and the conventional 48-h PCC assay.
- 19 January 2024
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 200 (5) , 448-458
Open AccessOptimizing chemical-induced premature chromosome condensation assay for rapid estimation of high-radiation doses
In the event of exposure to high doses of radiation, prompt dose estimation is crucial for selecting appropriate treatment modalities, such as cytokine therapy or stem cell transplantation. The chemical-induced premature chromosome condensation (PCC) method offers a simple approach for such dose estimation with significant radiation exposure, but its 48-h incubation time poses challenges for early dose assessment. In this study, we optimized the chemical-induced PCC assay for more rapid dose assessment. A sufficient number of PCC and G2/M-PCC cells were obtained after 40 h of culture for irradiated human peripheral blood up to 20 Gy. By adding caffeine (final concentration of 1 mM) at 34 h from the start of culture, G2/M-PCC index increased by 1.4-fold in 10 Gy cultures. There was also no significant difference in the G2/M-PCC ring frequency induced for doses 0 to 15 Gy between our 40-h caffeine-supplemented chemical-induced PCC method and the conventional 48-h PCC assay.
- Open Access
- 24 May 2023
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 99 (7) , 1037-1045
Severity scoring systems for radiation-induced GI injury – prioritization for use of GI-ARS medical countermeasures
Severity scoring systems for ionizing radiation-induced gastrointestinal injury have been used in animal radiation models, human studies involving the use of radiation therapy, and radiation accidents. Various radiation exposure scenarios (i.e., total body irradiation, total abdominal irradiation, etc.) have been used to investigate ionizing radiation-induced gastrointestinal injury. These radiation-induced GI severity scoring systems are based on clinical signs and symptoms and gastrointestinal-specific biomarkers (i.e., citrulline, etc.). In addition, the time course for radiation-induced changes in blood citrulline levels were compared across various animal (i.e., mice, minipigs, Rhesus Macaque, etc.) and human model systems. A worksheet tool was developed to prioritize individuals with severe life-threatening gastrointestinal acute radiation syndrome, based on the design of the Exposure and Symptom Tool addressing hematopoietic acute radiation syndrome, to rescue individuals from potential gastrointestinal acute radiation syndrome injury. This tool provides a triage diagnostic approach to assist first-responders to assess individuals suspected of showing gastrointestinal acute radiation syndrome severity to guide medical management, hence enhancing medical readiness for managing radiological casualties.
- 24 May 2023
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 99 (7) , 1037-1045
Open AccessSeverity scoring systems for radiation-induced GI injury – prioritization for use of GI-ARS medical countermeasures
Severity scoring systems for ionizing radiation-induced gastrointestinal injury have been used in animal radiation models, human studies involving the use of radiation therapy, and radiation accidents. Various radiation exposure scenarios (i.e., total body irradiation, total abdominal irradiation, etc.) have been used to investigate ionizing radiation-induced gastrointestinal injury. These radiation-induced GI severity scoring systems are based on clinical signs and symptoms and gastrointestinal-specific biomarkers (i.e., citrulline, etc.). In addition, the time course for radiation-induced changes in blood citrulline levels were compared across various animal (i.e., mice, minipigs, Rhesus Macaque, etc.) and human model systems. A worksheet tool was developed to prioritize individuals with severe life-threatening gastrointestinal acute radiation syndrome, based on the design of the Exposure and Symptom Tool addressing hematopoietic acute radiation syndrome, to rescue individuals from potential gastrointestinal acute radiation syndrome injury. This tool provides a triage diagnostic approach to assist first-responders to assess individuals suspected of showing gastrointestinal acute radiation syndrome severity to guide medical management, hence enhancing medical readiness for managing radiological casualties.
- Open Access
- 22 March 2023
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 99 (7) , 1055-1065
Combined radiation injury and its impacts on radiation countermeasures and biodosimetry
Preparedness for medical responses to major radiation accidents and the increasing threat of nuclear warfare worldwide necessitates an understanding of the complexity of combined radiation injury (...
- 22 March 2023
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 99 (7) , 1055-1065
Open AccessCombined radiation injury and its impacts on radiation countermeasures and biodosimetry
Preparedness for medical responses to major radiation accidents and the increasing threat of nuclear warfare worldwide necessitates an understanding of the complexity of combined radiation injury (...
- Open Access
- 25 January 2022
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 42 (1) , 010503
Early molecular markers for retrospective biodosimetry and prediction of acute health effects
Radiation-induced biological changes occurring within hours and days after irradiation can be potentially used for either exposure reconstruction (retrospective dosimetry) or the prediction of consecutively occurring acute or chronic health effects. The advantage of molecular protein or gene expression (GE) (mRNA) marker lies in their capability for early (1–3 days after irradiation), high-throughput and point-of-care diagnosis, required for the prediction of the acute radiation syndrome (ARS) in radiological or nuclear scenarios. These molecular marker in most cases respond differently regarding exposure characteristics such as e.g. radiation quality, dose, dose rate and most importantly over time. Changes over time are in particular challenging and demand certain strategies to deal with. With this review, we provide an overview and will focus on already identified and used mRNA GE and protein markers of the peripheral blood related to the ARS. These molecules are examined in light of ‘ideal’ characteristics of a biomarkers (e.g. easy accessible, early response, signal persistency) and the validation degree. Finally, we present strategies on the use of these markers considering challenges as their variation over time and future developments regarding e.g. origin of samples, point of care and high-throughput diagnosis.
- 25 January 2022
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 42 (1) , 010503
Open AccessEarly molecular markers for retrospective biodosimetry and prediction of acute health effects
Radiation-induced biological changes occurring within hours and days after irradiation can be potentially used for either exposure reconstruction (retrospective dosimetry) or the prediction of consecutively occurring acute or chronic health effects. The advantage of molecular protein or gene expression (GE) (mRNA) marker lies in their capability for early (1–3 days after irradiation), high-throughput and point-of-care diagnosis, required for the prediction of the acute radiation syndrome (ARS) in radiological or nuclear scenarios. These molecular marker in most cases respond differently regarding exposure characteristics such as e.g. radiation quality, dose, dose rate and most importantly over time. Changes over time are in particular challenging and demand certain strategies to deal with. With this review, we provide an overview and will focus on already identified and used mRNA GE and protein markers of the peripheral blood related to the ARS. These molecules are examined in light of ‘ideal’ characteristics of a biomarkers (e.g. easy accessible, early response, signal persistency) and the validation degree. Finally, we present strategies on the use of these markers considering challenges as their variation over time and future developments regarding e.g. origin of samples, point of care and high-throughput diagnosis.
- Open Access
- 1 December 2021
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 41 (4) , R152-R175
Early-response multiple-parameter biodosimetry and dosimetry: risk predictions
The accepted generic multiple-parameter and early-response biodosimetry and dosimetry assessment approach for suspected high-dose radiation (i.e. life-threatening) exposure includes measuring radioactivity associated with the exposed individual (if appropriate); observing and recording prodromal signs/symptoms; obtaining serial complete blood counts with white-blood-cell differential; sampling blood for the chromosome-aberration cytogenetic bioassay using the ‘gold standard’ dicentric assay (premature chromosome condensation assay for exposures >5 Gy photon acute doses equivalent), measurement of proteomic biomarkers and gene expression assays for dose assessment; bioassay sampling, if appropriate, to determine radioactive internal contamination; physical dose reconstruction, and using other available opportunistic dosimetry approaches. Biodosimetry and dosimetry resources are identified and should be setup in advance along with agreements to access additional national, regional, and international resources. This multifaceted capability needs to be integrated into a biodosimetry/dosimetry ‘concept of operations’ for use in a radiological emergency. The combined use of traditional biological-, clinical-, and physical-dosimetry should be use in an integrated approach to provide: (a) early-phase diagnostics to guide the development of initial medical-management strategy, and (b) intermediate and definitive assessment of radiation dose and injury. Use of early-phase (a) clinical signs and symptoms, (b) blood chemistry biomarkers, and (c) triage cytogenetics shows diagnostic utility to predict acute radiation injury severity.
- 1 December 2021
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 41 (4) , R152-R175
Open AccessEarly-response multiple-parameter biodosimetry and dosimetry: risk predictions
The accepted generic multiple-parameter and early-response biodosimetry and dosimetry assessment approach for suspected high-dose radiation (i.e. life-threatening) exposure includes measuring radioactivity associated with the exposed individual (if appropriate); observing and recording prodromal signs/symptoms; obtaining serial complete blood counts with white-blood-cell differential; sampling blood for the chromosome-aberration cytogenetic bioassay using the ‘gold standard’ dicentric assay (premature chromosome condensation assay for exposures >5 Gy photon acute doses equivalent), measurement of proteomic biomarkers and gene expression assays for dose assessment; bioassay sampling, if appropriate, to determine radioactive internal contamination; physical dose reconstruction, and using other available opportunistic dosimetry approaches. Biodosimetry and dosimetry resources are identified and should be setup in advance along with agreements to access additional national, regional, and international resources. This multifaceted capability needs to be integrated into a biodosimetry/dosimetry ‘concept of operations’ for use in a radiological emergency. The combined use of traditional biological-, clinical-, and physical-dosimetry should be use in an integrated approach to provide: (a) early-phase diagnostics to guide the development of initial medical-management strategy, and (b) intermediate and definitive assessment of radiation dose and injury. Use of early-phase (a) clinical signs and symptoms, (b) blood chemistry biomarkers, and (c) triage cytogenetics shows diagnostic utility to predict acute radiation injury severity.
- 1 July 2020
- Published by Wolters Kluwer Health in Health Physics
- Vol. 119 (1) , 52-58
Automated Dicentric Aberration Scoring for Triage Dose Assessment: 60Co Gamma Ray Dose-response at Different Dose Rates
The objective of this study was to establish radiation dose-response calibration curves using automated dicentric scoring to support rapid and accurate cytogenetic triage dose-assessment. Blood was drawn from healthy human volunteers and exposed to 60Co gamma rays at several dose rates (i.e., 1.0, 0.6, and 0.1 Gy min−1). After radiation, the blood was placed for 2 h in a 37 °C incubator for repair. Blood was then cultured in complete media to which a mitogen (i.e., phytoghemagglutinin, concentration 4%) was added for 48 h. Colcemid was added to the culture at a final concentration of 0.2 μg mL−1 after 24 h for the purpose of arresting first-division metaphase mitotics. Cells were harvested at the end of 48 h. Samples were processed using an automated metaphase harvester and automated microscope metaphase finder equipped with a suite of software including a specialized automated dicentric scoring application. The data obtained were used to create dose-response tables of dicentric yields. The null hypothesis that the data is Poisson-distributed could not be rejected at the significance level of α = 0.05 using results from a Shiny R Studio application (goodness-of-fit Poisson). Calibration curves based on linear-quadratic fits for 60Co gamma rays at the three different dose rates were generated using these data. The calibration curves were used to detect blind test cases. In conclusion, using the automated harvester and automated microscope metaphase finder with associated automated dicentric scoring software demonstrates high-throughput with suitable accuracy for triage radiation dose assessment.
- 1 July 2020
- Published by Wolters Kluwer Health in Health Physics
- Vol. 119 (1) , 52-58
Automated Dicentric Aberration Scoring for Triage Dose Assessment: 60Co Gamma Ray Dose-response at Different Dose Rates
The objective of this study was to establish radiation dose-response calibration curves using automated dicentric scoring to support rapid and accurate cytogenetic triage dose-assessment. Blood was drawn from healthy human volunteers and exposed to 60Co gamma rays at several dose rates (i.e., 1.0, 0.6, and 0.1 Gy min−1). After radiation, the blood was placed for 2 h in a 37 °C incubator for repair. Blood was then cultured in complete media to which a mitogen (i.e., phytoghemagglutinin, concentration 4%) was added for 48 h. Colcemid was added to the culture at a final concentration of 0.2 μg mL−1 after 24 h for the purpose of arresting first-division metaphase mitotics. Cells were harvested at the end of 48 h. Samples were processed using an automated metaphase harvester and automated microscope metaphase finder equipped with a suite of software including a specialized automated dicentric scoring application. The data obtained were used to create dose-response tables of dicentric yields. The null hypothesis that the data is Poisson-distributed could not be rejected at the significance level of α = 0.05 using results from a Shiny R Studio application (goodness-of-fit Poisson). Calibration curves based on linear-quadratic fits for 60Co gamma rays at the three different dose rates were generated using these data. The calibration curves were used to detect blind test cases. In conclusion, using the automated harvester and automated microscope metaphase finder with associated automated dicentric scoring software demonstrates high-throughput with suitable accuracy for triage radiation dose assessment.
- 1 December 2018
- Published by American Association for Laboratory Animal Science in Comparative Medicine
- Vol. 68 (6) , 474-488
System for Scoring Severity of Acute Radiation Syndrome Response in Rhesus Macaques (Macaca mulatta)
We developed a clinical assessment tool for use in an NHP radiation model to 1) quantify severity responses for subsyndromes of the acute radiation syndrome (ARS; that is, hematopoietic and others) and 2) identify animals that required enhanced monitoring. Our assessment tool was based primarily on the MEdical TREatment ProtocOLs for Radiation Accident Victims (METREPOL) scoring system but was adapted for NHP to include additional indices (for example, behaviors) for use in NHP studies involving limited medical intervention. Male (n = 16) and female (n = 12) rhesus macaques (Macaca mulatta; 5 groups: sham and 1.0, 3.5, 6.5, and 8.5 Gy; n = 6 per group) received sham- or bilateral 60 Co γ-irradiation at approximately 0.6 Gy/mn. Clinical signs of ARS and blood analysis were obtained before and serially for clinical assessment during the period of 6 h to 60 d after sham or 60 Co irradiation. Minimal supportive care (that is, supplemental nutrition, subcutaneous fluid, loperamide, acetaminophen, and topical antibiotic ointment) was prescribed based on clinical observations. Results from clinical signs and assays for assessment of relevant organ systems in individual animals were stratified into ARS severity scores of normal (0), mild (1), moderate (2), and severe (3 or 4). Individual NHP were scored for maximal subsyndrome ARS severity in multiple organ systems by using the proposed ARS scoring system to obtain an overall ARS response category. One NHP died unexpectedly. The multiple-parameter ARS severity scoring tool aided in the identification of animals in the high-dose (6.5 and 8.5 Gy) groups that required enhanced monitoring.
- 1 December 2018
- Published by American Association for Laboratory Animal Science in Comparative Medicine
- Vol. 68 (6) , 474-488
System for Scoring Severity of Acute Radiation Syndrome Response in Rhesus Macaques (Macaca mulatta)
We developed a clinical assessment tool for use in an NHP radiation model to 1) quantify severity responses for subsyndromes of the acute radiation syndrome (ARS; that is, hematopoietic and others) and 2) identify animals that required enhanced monitoring. Our assessment tool was based primarily on the MEdical TREatment ProtocOLs for Radiation Accident Victims (METREPOL) scoring system but was adapted for NHP to include additional indices (for example, behaviors) for use in NHP studies involving limited medical intervention. Male (n = 16) and female (n = 12) rhesus macaques (Macaca mulatta; 5 groups: sham and 1.0, 3.5, 6.5, and 8.5 Gy; n = 6 per group) received sham- or bilateral 60 Co γ-irradiation at approximately 0.6 Gy/mn. Clinical signs of ARS and blood analysis were obtained before and serially for clinical assessment during the period of 6 h to 60 d after sham or 60 Co irradiation. Minimal supportive care (that is, supplemental nutrition, subcutaneous fluid, loperamide, acetaminophen, and topical antibiotic ointment) was prescribed based on clinical observations. Results from clinical signs and assays for assessment of relevant organ systems in individual animals were stratified into ARS severity scores of normal (0), mild (1), moderate (2), and severe (3 or 4). Individual NHP were scored for maximal subsyndrome ARS severity in multiple organ systems by using the proposed ARS scoring system to obtain an overall ARS response category. One NHP died unexpectedly. The multiple-parameter ARS severity scoring tool aided in the identification of animals in the high-dose (6.5 and 8.5 Gy) groups that required enhanced monitoring.
- 1 July 2018
- Published by Wolters Kluwer Health in Health Physics
- Vol. 115 (1) , 29-36
Use of Proteomic and Hematology Biomarkers for Prediction of Hematopoietic Acute Radiation Syndrome Severity in Baboon Radiation Models
Use of plasma proteomic and hematological biomarkers represents a promising approach to provide useful diagnostic information for assessment of the severity of hematopoietic acute radiation syndrome. Eighteen baboons were evaluated in a radiation model that underwent total-body and partial-body irradiations at doses of 60Co gamma rays from 2.5 to 15 Gy at dose rates of 6.25 cGy min-1 and 32 cGy min-1. Hematopoietic acute radiation syndrome severity levels determined by an analysis of blood count changes measured up to 60 d after irradiation were used to gauge overall hematopoietic acute radiation syndrome severity classifications. A panel of protein biomarkers was measured on plasma samples collected at 0 to 28 d after exposure using electrochemiluminescence-detection technology. The database was split into two distinct groups (i.e., “calibration,” n = 11; “validation,” n = 7). The calibration database was used in an initial stepwise regression multivariate model-fitting approach followed by down selection of biomarkers for identification of subpanels of hematopoietic acute radiation syndrome-responsive biomarkers for three time windows (i.e., 0–2 d, 2–7 d, 7–28 d). Model 1 (0–2 d) includes log C-reactive protein (p < 0.0001), log interleukin‐13 (p < 0.0054), and procalcitonin (p < 0.0316) biomarkers; model 2 (2–7 d) includes log CD27 (p < 0.0001), log FMS-related tyrosine kinase 3 ligand (p < 0.0001), log serum amyloid A (p < 0.0007), and log interleukin‐6 (p < 0.0002); and model 3 (7–28 d) includes log CD27 (p < 0.0012), log serum amyloid A (p < 0.0002), log erythropoietin (p < 0.0001), and log CD177 (p < 0.0001). The predicted risk of radiation injury categorization values, representing the hematopoietic acute radiation syndrome severity outcome for the three models, produced least squares multiple regression fit confidences of R 2 = 0.73, 0.82, and 0.75, respectively. The resultant algorithms support the proof of concept that plasma proteomic biomarkers can supplement clinical signs and symptoms to assess hematopoietic acute radiation syndrome risk severity.
- 1 July 2018
- Published by Wolters Kluwer Health in Health Physics
- Vol. 115 (1) , 29-36
Use of Proteomic and Hematology Biomarkers for Prediction of Hematopoietic Acute Radiation Syndrome Severity in Baboon Radiation Models
Use of plasma proteomic and hematological biomarkers represents a promising approach to provide useful diagnostic information for assessment of the severity of hematopoietic acute radiation syndrome. Eighteen baboons were evaluated in a radiation model that underwent total-body and partial-body irradiations at doses of 60Co gamma rays from 2.5 to 15 Gy at dose rates of 6.25 cGy min-1 and 32 cGy min-1. Hematopoietic acute radiation syndrome severity levels determined by an analysis of blood count changes measured up to 60 d after irradiation were used to gauge overall hematopoietic acute radiation syndrome severity classifications. A panel of protein biomarkers was measured on plasma samples collected at 0 to 28 d after exposure using electrochemiluminescence-detection technology. The database was split into two distinct groups (i.e., “calibration,” n = 11; “validation,” n = 7). The calibration database was used in an initial stepwise regression multivariate model-fitting approach followed by down selection of biomarkers for identification of subpanels of hematopoietic acute radiation syndrome-responsive biomarkers for three time windows (i.e., 0–2 d, 2–7 d, 7–28 d). Model 1 (0–2 d) includes log C-reactive protein (p < 0.0001), log interleukin‐13 (p < 0.0054), and procalcitonin (p < 0.0316) biomarkers; model 2 (2–7 d) includes log CD27 (p < 0.0001), log FMS-related tyrosine kinase 3 ligand (p < 0.0001), log serum amyloid A (p < 0.0007), and log interleukin‐6 (p < 0.0002); and model 3 (7–28 d) includes log CD27 (p < 0.0012), log serum amyloid A (p < 0.0002), log erythropoietin (p < 0.0001), and log CD177 (p < 0.0001). The predicted risk of radiation injury categorization values, representing the hematopoietic acute radiation syndrome severity outcome for the three models, produced least squares multiple regression fit confidences of R 2 = 0.73, 0.82, and 0.75, respectively. The resultant algorithms support the proof of concept that plasma proteomic biomarkers can supplement clinical signs and symptoms to assess hematopoietic acute radiation syndrome risk severity.