Peter Mardle
Research Subjects
Peter Mardle has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Steven Holdcroft
Department of Chemistry, Simon Fraser University, Burnaby, BC, V5A 1S6, Canada
7 shared publications - Simon Cassegrain
Department of Chemistry, Simon Fraser University, 8888 University Drive, Burnaby, BC V5A 1S6, Canada
5 shared publications - Binyu Chen
Department of Chemistry, Simon Fraser University, 8888 University Drive, Burnaby, British Columbia V5A 1S6, Canada
3 shared publications - Torben Saatkamp
PSI Center for Energy and Environmental Sciences
3 shared publications Wei Qu
Clean Energy Innovation Research Centre
3 shared publications- Hanshuo Liu
Clean Energy Innovation Research Centre
2 shared publications
Latest Publications
- 20 April 2025
- Published by Elsevier in Electrochimica Acta
- Vol. 528
Effects of Aemion and Aemion+ binders in oxygen evolution reaction catalyst layers
- 20 April 2025
- Published by Elsevier in Electrochimica Acta
- Vol. 528
Effects of Aemion and Aemion+ binders in oxygen evolution reaction catalyst layers
- Open Access
- 1 April 2025
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 172 (4) , 044510
Edge-Type Reference Electrode Application for AEM-WE Durability Testing
Anion-exchange membrane water electrolyzers (AEM-WE) have been identified as a promising solution to deliver green hydrogen at a lower cost than alkaline water electrolyzers (AWEs) and proton-exchange membrane water electrolyzers (PEM-WEs). However, scaling AEM-WE is limited by high voltage degradation rates which can become amplified and more complicated during operation as components within the membrane electrode assembly (MEA) evolve and interact with one another. These phenomena necessitate testing protocols that capture the degradation of individual MEA components in situ. Herein, an edge-type reference electrode and a novel flow plate design enabled decoupling of anode and cathode degradation over stability tests >200 h. A critical assessment of the overpotential measurements is provided, utilizing half-cell impedance measurements to highlight the effects of electrode misalignment. 3-electrode cyclic voltammetry is presented as an effective in situ tool to evaluate electrode degradation. These findings demonstrate the utility of edge-type reference electrode configurations in stability tests for the development of commercial scale AEM-WE.
- 1 April 2025
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 172 (4) , 044510
Open AccessEdge-Type Reference Electrode Application for AEM-WE Durability Testing
Anion-exchange membrane water electrolyzers (AEM-WE) have been identified as a promising solution to deliver green hydrogen at a lower cost than alkaline water electrolyzers (AWEs) and proton-exchange membrane water electrolyzers (PEM-WEs). However, scaling AEM-WE is limited by high voltage degradation rates which can become amplified and more complicated during operation as components within the membrane electrode assembly (MEA) evolve and interact with one another. These phenomena necessitate testing protocols that capture the degradation of individual MEA components in situ. Herein, an edge-type reference electrode and a novel flow plate design enabled decoupling of anode and cathode degradation over stability tests >200 h. A critical assessment of the overpotential measurements is provided, utilizing half-cell impedance measurements to highlight the effects of electrode misalignment. 3-electrode cyclic voltammetry is presented as an effective in situ tool to evaluate electrode degradation. These findings demonstrate the utility of edge-type reference electrode configurations in stability tests for the development of commercial scale AEM-WE.
- 21 December 2023
- Published by American Chemical Society (ACS) in Chemistry of Materials
- Vol. 36 (1) , 197-210
Zwitterionic Ionenes toward Processable, Low Water-Containing Anion Exchange Membranes: Synthesis, Characterization, and Application in Electrochemical CO2 Reduction
- 21 December 2023
- Published by American Chemical Society (ACS) in Chemistry of Materials
- Vol. 36 (1) , 197-210
Zwitterionic Ionenes toward Processable, Low Water-Containing Anion Exchange Membranes: Synthesis, Characterization, and Application in Electrochemical CO2 Reduction
- Top Cited Papers
- 25 July 2023
- Published by American Chemical Society (ACS) in ACS Energy Letters
- Vol. 8 (8) , 3330-3342
Opportunities of Ionomer Development for Anion-Exchange Membrane Water Electrolysis
- 25 July 2023
- Published by American Chemical Society (ACS) in ACS Energy Letters
- Vol. 8 (8) , 3330-3342
Top Cited PapersOpportunities of Ionomer Development for Anion-Exchange Membrane Water Electrolysis
- Open Access
- 13 June 2023
- Published by Wiley in ChemSusChem
- Vol. 16 (14) , e202202376
Performance and Stability of Aemion and Aemion+ Membranes in Zero‐Gap CO2 Electrolyzers with Mild Anolyte Solutions
The dependence of performance and stability of a zero‐gap CO2 electrolyzer on the properties of the anion exchange membrane (AEM) is examined. This work firstly assesses the influence of the anolyte when using an Aemion membrane and then shows that when using 10 mM KHCO3, a CO2 electrolyzer using a next‐generation Aemion+ membrane can achieve lower cell voltages and longer lifetimes due to increased water permeation. The impact of lower permselectivity of Aemion+ on water transport is also discussed. Using Aemion+, a cell voltage of 3.17 V at 200 mA cm−2 is achieved at room temperature, with a faradaic efficiency of >90 %. Stable CO2 electrolysis at 100 mA cm−2 is demonstrated for 100 h, but with reduced lifetime at 300 mA cm−2. However, the lifetime of the cell at high current densities is shown to be increased by improving water transport characteristics of the AEM and reducing dimensional swelling, as well as by improving cathode design to reduce localized dehydration of the membrane.
- 13 June 2023
- Published by Wiley in ChemSusChem
- Vol. 16 (14) , e202202376
Open AccessPerformance and Stability of Aemion and Aemion+ Membranes in Zero‐Gap CO2 Electrolyzers with Mild Anolyte Solutions
The dependence of performance and stability of a zero‐gap CO2 electrolyzer on the properties of the anion exchange membrane (AEM) is examined. This work firstly assesses the influence of the anolyte when using an Aemion membrane and then shows that when using 10 mM KHCO3, a CO2 electrolyzer using a next‐generation Aemion+ membrane can achieve lower cell voltages and longer lifetimes due to increased water permeation. The impact of lower permselectivity of Aemion+ on water transport is also discussed. Using Aemion+, a cell voltage of 3.17 V at 200 mA cm−2 is achieved at room temperature, with a faradaic efficiency of >90 %. Stable CO2 electrolysis at 100 mA cm−2 is demonstrated for 100 h, but with reduced lifetime at 300 mA cm−2. However, the lifetime of the cell at high current densities is shown to be increased by improving water transport characteristics of the AEM and reducing dimensional swelling, as well as by improving cathode design to reduce localized dehydration of the membrane.
- Open Access
- 26 January 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (2) , 024502
Proton Exchange Membrane Water Electrolysis Incorporating Sulfo-Phenylated Polyphenylene Catalyst Coated Membranes
Herein, fully hydrocarbon-based ionomer catalyst coated membranes (CCM)s based on sulfo-phenylated polyphenylene biphenyl (sPPB-H+) are evaluated in a proton exchange membrane water electrolyzer cell at 70 °C. In conjunction with catalyst layers incorporating Nafion® D520 ionomer, sPPB-H+ membranes require a lower applied potential than reference Nafion® NR112 recast membranes of equal thickness, e.g., 1.66 V vs 1.75 V at 1 A cm−2. Initially, sPPB-H+ membranes yield substantially lower gas crossover compared to the CCMs containing NR112 membrane, however, increasing gas crossover and a higher rates of voltage evolution is measured during a stability test at 1 A cm−2. A reinforced and commercialized membrane of similar chemistry (Pemion®) is also evaluated, demonstrating smaller changes to the initial gas crossover owing to higher mechanical stability. Employment of sPPB-H+ as the catalyst layer binder is also investigated, where the highest efficiency for all-sPPB-H+ CCMs is achieved when the anode and cathode ionomer content are 20 wt%, which from electrochemical impedance spectroscopy is predominately attributed to changes in the proton conductivity within the catalyst layer. Despite this advancement, high ionomer swelling and catalyst delamination led to shorter electrolyzer lifetimes for the all hydrocarbon and non fluorinated membrane electrode assembly, informing future ionomer development.
- 26 January 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (2) , 024502
Open AccessProton Exchange Membrane Water Electrolysis Incorporating Sulfo-Phenylated Polyphenylene Catalyst Coated Membranes
Herein, fully hydrocarbon-based ionomer catalyst coated membranes (CCM)s based on sulfo-phenylated polyphenylene biphenyl (sPPB-H+) are evaluated in a proton exchange membrane water electrolyzer cell at 70 °C. In conjunction with catalyst layers incorporating Nafion® D520 ionomer, sPPB-H+ membranes require a lower applied potential than reference Nafion® NR112 recast membranes of equal thickness, e.g., 1.66 V vs 1.75 V at 1 A cm−2. Initially, sPPB-H+ membranes yield substantially lower gas crossover compared to the CCMs containing NR112 membrane, however, increasing gas crossover and a higher rates of voltage evolution is measured during a stability test at 1 A cm−2. A reinforced and commercialized membrane of similar chemistry (Pemion®) is also evaluated, demonstrating smaller changes to the initial gas crossover owing to higher mechanical stability. Employment of sPPB-H+ as the catalyst layer binder is also investigated, where the highest efficiency for all-sPPB-H+ CCMs is achieved when the anode and cathode ionomer content are 20 wt%, which from electrochemical impedance spectroscopy is predominately attributed to changes in the proton conductivity within the catalyst layer. Despite this advancement, high ionomer swelling and catalyst delamination led to shorter electrolyzer lifetimes for the all hydrocarbon and non fluorinated membrane electrode assembly, informing future ionomer development.
- 8 June 2022
- Published by Royal Society of Chemistry (RSC) in Sustainable Energy & Fuels
- Vol. 6 (15) , 3551-3564
On the stability of anion exchange membrane fuel cells incorporating polyimidazolium ionene (Aemion+®) membranes and ionomers
We report the anion exchange membrane fuel cell (AEMFC) performance using commercial, polyimidazolium-based, Aemion+® as both the ionomer and membrane. Aemion+® affords reduced dimensional swelling yet higher water permeance compared to previously reported polybenzimidazolium-based Aemion® membranes and ionomers. Non-reinforced Aemion+® is shown to enhance the properties of Aemion® membranes, and Aemion+® reinforced with a fluorine-free polyolefin substrate is shown to enhance the properties considered important to fuel cell operation with respect to non-reinforced analogues. The highest AEMFC power density of 1.4 W cm−2 at 70 °C, 250 kPabs H2/O2 was obtained by using a direct membrane deposition (DMD) approach, where an ultrathin 5 μm membrane increased the voltage stability through enhanced water permeation, allowing characterization under these conditions. However, the reinforcement was found to be pivotal in enabling stable AEMFC operation at 80 °C, where a 10 μm-thick reinforced Aemion+® provided 1.1 W cm−2 power at 80 °C, 300 kPaabs H2/O2. The degradation properties of this material under varied cell temperatures, current densities and RHs are finally examined.
- 8 June 2022
- Published by Royal Society of Chemistry (RSC) in Sustainable Energy & Fuels
- Vol. 6 (15) , 3551-3564
On the stability of anion exchange membrane fuel cells incorporating polyimidazolium ionene (Aemion+®) membranes and ionomers
We report the anion exchange membrane fuel cell (AEMFC) performance using commercial, polyimidazolium-based, Aemion+® as both the ionomer and membrane. Aemion+® affords reduced dimensional swelling yet higher water permeance compared to previously reported polybenzimidazolium-based Aemion® membranes and ionomers. Non-reinforced Aemion+® is shown to enhance the properties of Aemion® membranes, and Aemion+® reinforced with a fluorine-free polyolefin substrate is shown to enhance the properties considered important to fuel cell operation with respect to non-reinforced analogues. The highest AEMFC power density of 1.4 W cm−2 at 70 °C, 250 kPabs H2/O2 was obtained by using a direct membrane deposition (DMD) approach, where an ultrathin 5 μm membrane increased the voltage stability through enhanced water permeation, allowing characterization under these conditions. However, the reinforcement was found to be pivotal in enabling stable AEMFC operation at 80 °C, where a 10 μm-thick reinforced Aemion+® provided 1.1 W cm−2 power at 80 °C, 300 kPaabs H2/O2. The degradation properties of this material under varied cell temperatures, current densities and RHs are finally examined.