Anil Gambhir
Anil Gambhir has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Amol Chitre
Wrightington Hospital, Wigan, United Kingdom
1 shared publication - Debbie Shaw
Trauma and Orthopaedics, Wrightington, Wigan and Leigh NHS Foundation Trust, Wigan, GBR
1 shared publication - George Pavlou
Wrightington Hospital, Wigan, United Kingdom
1 shared publication - Henry Wynn Jones
Wrightington Hospital, Wigan, United Kingdom
1 shared publication - Hiren Maganlal Divecha
Centre for Hip Surgery, Wrightington Hospital, Wrightington Wigan and Leigh NHS Foundation Trust, Wigan, UK
1 shared publication - Jez Oakley
Wrightington Hospital, Wigan, United Kingdom
1 shared publication
Latest Publications
- Open Access
- 1 March 2022
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 3 (3) , 229-235
Proximal femoral replacement in non-neoplastic revision hip arthroplasty
Aims: With increasing burden of revision hip arthroplasty (THA), one of the major challenges is the management of proximal femoral bone loss associated with previous multiple surgeries. Proximal femoral arthroplasty (PFA) has already been popularized for tumour surgeries. Our aim was to describe the outcome of using PFA in these demanding non-neoplastic cases. Methods: A retrospective review of 25 patients who underwent PFA for non-neoplastic indications between January 2009 and December 2015 was undertaken. Their clinical and radiological outcome, complication rates, and survival were recorded. All patients had the Stanmore Implant – Modular Endo-prosthetic Tumour System (METS). Results: At mean follow-up of 5.9 years, there were no periprosthetic fractures. Clearance of infection was achieved in 63.6% of cases. One hip was re-revised to pseudo arthroplasty for deep infection. Instability was noted in eight of the hips (32%), of which seven needed further surgery. Out of these eight hips with instability, five had preoperative infection. Deep infection was noted in five of the hips (20%), of which four were primarily revised for infection. One patient had aseptic loosening of the femoral component and awaits revision surgery. The Kaplan-Meier survivorship free of revision of any component for any reason was 72% (95% confidence interval (CI) 51.3% to 92.7%), and for revisions of only femoral component for any reason was 96% (95% CI 86.3% to 105.7%) at five years. Conclusion: Dislocation and infection remain the major cause for failure, particularly in patients with pre-existing infection. The use of dual mobility cups, silver-coated implants, and less aggressive postoperative rehabilitation regimens would possibly aid in the reduction of complications. PFA performed in patients with periprosthetic fracture seem to fair better. This study supports the judicious use of PFA in non-oncological revision hip arthroplasties, and that they be performed by experienced revision arthroplasty surgeons. Cite this article: Bone Jt Open 2022;3(3):229–235.
- 1 March 2022
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 3 (3) , 229-235
Open AccessProximal femoral replacement in non-neoplastic revision hip arthroplasty
Aims: With increasing burden of revision hip arthroplasty (THA), one of the major challenges is the management of proximal femoral bone loss associated with previous multiple surgeries. Proximal femoral arthroplasty (PFA) has already been popularized for tumour surgeries. Our aim was to describe the outcome of using PFA in these demanding non-neoplastic cases. Methods: A retrospective review of 25 patients who underwent PFA for non-neoplastic indications between January 2009 and December 2015 was undertaken. Their clinical and radiological outcome, complication rates, and survival were recorded. All patients had the Stanmore Implant – Modular Endo-prosthetic Tumour System (METS). Results: At mean follow-up of 5.9 years, there were no periprosthetic fractures. Clearance of infection was achieved in 63.6% of cases. One hip was re-revised to pseudo arthroplasty for deep infection. Instability was noted in eight of the hips (32%), of which seven needed further surgery. Out of these eight hips with instability, five had preoperative infection. Deep infection was noted in five of the hips (20%), of which four were primarily revised for infection. One patient had aseptic loosening of the femoral component and awaits revision surgery. The Kaplan-Meier survivorship free of revision of any component for any reason was 72% (95% confidence interval (CI) 51.3% to 92.7%), and for revisions of only femoral component for any reason was 96% (95% CI 86.3% to 105.7%) at five years. Conclusion: Dislocation and infection remain the major cause for failure, particularly in patients with pre-existing infection. The use of dual mobility cups, silver-coated implants, and less aggressive postoperative rehabilitation regimens would possibly aid in the reduction of complications. PFA performed in patients with periprosthetic fracture seem to fair better. This study supports the judicious use of PFA in non-oncological revision hip arthroplasties, and that they be performed by experienced revision arthroplasty surgeons. Cite this article: Bone Jt Open 2022;3(3):229–235.
- Open Access
- 1 July 2021
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 6 (3)
Early Functional Outcomes After Evolutionary Total Knee Arthroplasty
Background: Total knee replacement (TKR) designs continue to evolve with the aim of improving patient outcomes; however, there remains a significant patient dissatisfaction rate. We report the early functional outcomes of an evolutionary knee design in the context of a single-blinded, noninferiority, randomized controlled trial. Methods: Patients were randomized to receive either the P.F.C. SIGMA or ATTUNE knee implant systems (DePuy Synthes). All implants were fixed-bearing, cruciate-retaining, and cemented constructs. Patients were assessed at baseline and 6 weeks, 3 months, and 1 year postoperatively using clinical and functional outcome measures, including range of motion, Oxford Knee Score (OKS), Oxford Knee Score-Activity and Participation Questionnaire (OKS-APQ), Patient Knee Implant Performance (PKIP) score, 5-Level EuroQol 5 Dimensions (EQ-5D-5L), and Short Form-36 outcome measures. Results: There were 150 patients who underwent a surgical procedure (76 with the ATTUNE implant and 74 with the P.F.C. SIGMA implant), with 147 patients remaining at the final review. No differences were observed in any of the outcome measures between the groups at any time point. Tourniquet time was significantly shorter in the P.F.C. SIGMA arm (p = 0.001); however, this had no clinical impact on the OKS (analysis of covariance [ANCOVA] test) at the final review (p = 0.825). There was no difference in the numbers of patients achieving the minimal clinically important difference for the OKS between the groups (p = 0.817). Conclusions: This trial did not show inferiority of the ATTUNE implant when compared with the P.F.C. SIGMA implant. The authors believe that implant innovation should continue and that modern implants should be introduced into the market following randomized controlled trials. Further work should assess the effect of non-implant-related factors on patient outcomes. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
- 1 July 2021
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 6 (3)
Open AccessEarly Functional Outcomes After Evolutionary Total Knee Arthroplasty
Background: Total knee replacement (TKR) designs continue to evolve with the aim of improving patient outcomes; however, there remains a significant patient dissatisfaction rate. We report the early functional outcomes of an evolutionary knee design in the context of a single-blinded, noninferiority, randomized controlled trial. Methods: Patients were randomized to receive either the P.F.C. SIGMA or ATTUNE knee implant systems (DePuy Synthes). All implants were fixed-bearing, cruciate-retaining, and cemented constructs. Patients were assessed at baseline and 6 weeks, 3 months, and 1 year postoperatively using clinical and functional outcome measures, including range of motion, Oxford Knee Score (OKS), Oxford Knee Score-Activity and Participation Questionnaire (OKS-APQ), Patient Knee Implant Performance (PKIP) score, 5-Level EuroQol 5 Dimensions (EQ-5D-5L), and Short Form-36 outcome measures. Results: There were 150 patients who underwent a surgical procedure (76 with the ATTUNE implant and 74 with the P.F.C. SIGMA implant), with 147 patients remaining at the final review. No differences were observed in any of the outcome measures between the groups at any time point. Tourniquet time was significantly shorter in the P.F.C. SIGMA arm (p = 0.001); however, this had no clinical impact on the OKS (analysis of covariance [ANCOVA] test) at the final review (p = 0.825). There was no difference in the numbers of patients achieving the minimal clinically important difference for the OKS between the groups (p = 0.817). Conclusions: This trial did not show inferiority of the ATTUNE implant when compared with the P.F.C. SIGMA implant. The authors believe that implant innovation should continue and that modern implants should be introduced into the market following randomized controlled trials. Further work should assess the effect of non-implant-related factors on patient outcomes. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.