Bayu-Tri Murti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bayu-Tri Murti has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Po-Kang Yang
Department of Biomedical Sciences and Engineering National Central University Taoyuan Taiwan
2 shared publications - Bansi Dhar Malhotra
Nanobioelectronics Laboratory, Department of Biotechnology, Delhi Technological University, Delhi, India
1 shared publication - Carlo Carraro
Department of Chemical and Biomolecular Engineering and Berkeley Sensor and Actuator Center, University of California at Berkeley, Berkeley, CA, USA
1 shared publication - Chuan-Pei Lee
Department of Applied Physics and Chemistry, University of Taipei, No.1,Ai-Guo West Road,Taipei,10048 Taiwan R.O.C., Taipei, 10048, TAIWAN
1 shared publication - Francesca Rossi
Institute of Materials for Electronics and Magnetism, National Research Council (CNR-IMEM), Viale Area delle Scienze 37/A, 43100 Parma, PR, Italy
1 shared publication - Kirti Saxena
Amity Institute of Nanotechnology, Amity University Uttar Pradesh (AUUP), Sector-125, Noida 201313, India
1 shared publication
Latest Publications
- Open Access
- 23 November 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (12) , 1066
Fabrication of a Molecularly Imprinted Nano-Interface-Based Electrochemical Biosensor for the Detection of CagA Virulence Factors of H. pylori
H. pylori is responsible for several stomach-related diseases including gastric cancer. The main virulence factor responsible for its establishment in human gastric cells is known as CagA. Therefore, in this study, we have fabricated a highly sensitive MIP-based electrochemical biosensor for the detection of CagA. For this, an rGO and gold-coated, screen-printed electrode sensing platform was designed to provide a surface for the immobilization of a CagA-specific, molecularly imprinted polymer; then it was characterized electrochemically. Interestingly, molecular dynamics simulations were studied to optimize the MIP prepolymerization system, resulting in a well-matched, optimized molar ratio within the experiment. A low binding energy upon template removal indicates the capability of MIP to recognize the CagA antigen through a strong binding affinity. Under the optimized electrochemical experimental conditions, the fabricated CagA-MIP/Au/rGO@SPE sensor exhibited high sensitivity (0.275 µA ng−1 mL−1) and a very low limit of detection (0.05 ng mL−1) in a linear range of 0.05–50 ng mL−1. The influence of other possible interferents in analytical response has also been observed with the successful determination of the CagA antigen.
- 23 November 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (12) , 1066
Open AccessFabrication of a Molecularly Imprinted Nano-Interface-Based Electrochemical Biosensor for the Detection of CagA Virulence Factors of H. pylori
H. pylori is responsible for several stomach-related diseases including gastric cancer. The main virulence factor responsible for its establishment in human gastric cells is known as CagA. Therefore, in this study, we have fabricated a highly sensitive MIP-based electrochemical biosensor for the detection of CagA. For this, an rGO and gold-coated, screen-printed electrode sensing platform was designed to provide a surface for the immobilization of a CagA-specific, molecularly imprinted polymer; then it was characterized electrochemically. Interestingly, molecular dynamics simulations were studied to optimize the MIP prepolymerization system, resulting in a well-matched, optimized molar ratio within the experiment. A low binding energy upon template removal indicates the capability of MIP to recognize the CagA antigen through a strong binding affinity. Under the optimized electrochemical experimental conditions, the fabricated CagA-MIP/Au/rGO@SPE sensor exhibited high sensitivity (0.275 µA ng−1 mL−1) and a very low limit of detection (0.05 ng mL−1) in a linear range of 0.05–50 ng mL−1. The influence of other possible interferents in analytical response has also been observed with the successful determination of the CagA antigen.
- Open Access
Cobalt Oxide-Decorated Silicon Carbide Nano-Tree Array Electrode for Micro-Supercapacitor Application
A cobalt oxide (Co3O4)-decorated silicon carbide (SiC) nano-tree array (denoted as Co3O4/SiC NTA) electrode is synthesized, and it is investigated for use in micro-supercapacitor applications. Firstly, the well-standing SiC nanowires (NWs) are prepared by nickel (Ni)-catalyzed chemical vapor deposition (CVD) method, and then the thin layer of Co3O4 and the hierarchical Co3O4 nano-flower-clusters are, respectively, fabricated on the side-walls and the top side of the SiC NWs via electrodeposition. The deposition of Co3O4 on the SiC NWs benefits the charge transfer at the electrode/aqueous electrolyte interface due to its extremely hydrophilic surface characteristic after Co3O4 decoration. Furthermore, the Co3O4/SiC NTA electrode provides a directional charge transport route along the length of SiC nanowires owing to their well-standing architecture. By using the Co3O4/SiC NTA electrode for micro-supercapacitor application, the areal capacitance obtained from cyclic voltammetry measurement reaches 845 mF cm−2 at a 10 mV s−1 scan rate. Finally, the capacitance durability is also evaluated by the cycling test of cyclic voltammetry at a high scan rate of 150 mV s−1 for 2000 cycles, exhibiting excellent stability.
Open AccessCobalt Oxide-Decorated Silicon Carbide Nano-Tree Array Electrode for Micro-Supercapacitor Application
A cobalt oxide (Co3O4)-decorated silicon carbide (SiC) nano-tree array (denoted as Co3O4/SiC NTA) electrode is synthesized, and it is investigated for use in micro-supercapacitor applications. Firstly, the well-standing SiC nanowires (NWs) are prepared by nickel (Ni)-catalyzed chemical vapor deposition (CVD) method, and then the thin layer of Co3O4 and the hierarchical Co3O4 nano-flower-clusters are, respectively, fabricated on the side-walls and the top side of the SiC NWs via electrodeposition. The deposition of Co3O4 on the SiC NWs benefits the charge transfer at the electrode/aqueous electrolyte interface due to its extremely hydrophilic surface characteristic after Co3O4 decoration. Furthermore, the Co3O4/SiC NTA electrode provides a directional charge transport route along the length of SiC nanowires owing to their well-standing architecture. By using the Co3O4/SiC NTA electrode for micro-supercapacitor application, the areal capacitance obtained from cyclic voltammetry measurement reaches 845 mF cm−2 at a 10 mV s−1 scan rate. Finally, the capacitance durability is also evaluated by the cycling test of cyclic voltammetry at a high scan rate of 150 mV s−1 for 2000 cycles, exhibiting excellent stability.