Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ahmed Mahmoud Alnahhal has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Insight into the accuracy and precision of SEM–EDS hyperspectral mapping for quantitative phase analysis in hydrated cement paste

    by Zuobang Yao, Ahmed Mahmoud Alnahhal, Yunxuan Cui, Jiayi Zhang, Seunghee Park, Taehwan Kim

  • Open Access

    Comprehensive evaluation on the properties of blended cement containing calcined paper sludge

    by Mohammed K. H. Radwan, Farooq Ahmed Athar, Jerome Song Yeo, Ahmed Mahmoud Alnahhal, Haider Hamad Ghayeb, Chee Ban Cheah, Kim Hung Mo

    This paper investigates the feasibility of exploiting paper sludge (PS) waste as partial cement replacement. Initially, PS was subjected to treatment by calcination to obtain paper sludge ash (PSA) followed by physical and chemical characterization. The influence of PSA inclusion at various cement replacement levels (5, 10, and 15% by weight) on cement properties was initially assessed. Next, the fresh properties, mechanical strengths, water transport, sulfate resistance, and drying shrinkage of blended cement mortars were observed and evaluated. Finally, the microstructure of selected blended cement pastes was observed through SEM–EDS, XRD, and TGA analysis. It was confirmed that using up to 15% of PSA complies with BS EN 196–3 requirements. The results also demonstrated that incorporation of up to 10% PSA was favourable as it has minimal influence on the consistency, early and late age, as well as residual strengths. Meanwhile, the filler effect of PSA imparted an improvement in drying shrinkage (> 7%), sulfate resistance (− 40%) as well as sorptivity when 5–10% of cement was replaced with PSA. While slight changes were observed from the diffractogram, both SEM–EDS and TGA–DSC analysis suggested that limited hydration occurred, hence PSA filler effect is more dominant. Overall, this study suggests limiting PSA incorporation in blended cement mortar mixtures up to 10% to attain adequate performance. Consequently, an eco-friendly blended cement can be produced with reduced cement usage while valorising waste streams from the paper industry simultaneously. Graphical abstract


  • Open Access

    PERFORMANCE EVALUATION OF PALM OIL CLINKER AS CEMENT AND SAND REPLACEMENT MATERIALS IN FOAMED CONCRETE

    by Farhang Salari, U. Johnson Alengaram, Ahmed Mahmoud Alnahhal, Zainah Ibrahim, Karthick Srinivas M, Muhammad S. I. Ibrahim, Anand N

    Cellular lightweight concrete (CLC), also known as foamed concrete, has been extensively used in construction for decades. Foamed concrete’s properties include low density, excellent thermal conductivity, great workability, and selfcompaction; these features enable foamed concrete to be utilized in various contexts. However, the excessive use of conventional materials in concrete production harms the environment. Therefore, using agro-waste as a material to construct ecologically sustainable structures has numerous practical and financial benefits. Palm oil clinker (POC) is a waste product resulting from solid waste combustion during palm oil extraction. This research focused on the properties of foamed concrete with POC at 0%, 25%, 50%, 75%, and 100% as the fine aggregate replacement to develop lightweight foamed concrete (LFC) with a density of 1300 kg/m3. Besides, the potential of POC powder (POCP) and thermally activated POCP (TPOCP) at 0%, 10%, 20%, and 30% as cement replacements was examined. The development of compressive strength during a 90-day curing period was investigated. In addition, tensile and flexural strengths were assessed and reported, and the elastic modulus of the LFC was discussed. The transport properties of water absorption, porosity, and sorptivity were also investigated. The durability of concrete derivatives can exhibit the product’s resistance to chemical attacks and environmental conditions. After 75 days of immersion in hydrochloric acid and magnesium sulfate, the chemical resistivity of the produced LFC was determined by measuring the loss in weight and compressive strength. In addition, the effects of elevated temperatures on the LFC were determined by analyzing the mass loss and compressive strength degradation of specimens exposed to temperatures ranging from 200 to 800 °C. The test results demonstrated that the complete replacement of sand with POC enhanced the compressive strength of LFC by more than 50%. Similarly, POC-based LFC had higher flexural and tensile strengths than normal LFC. Besides, substituting 20% of cement with TPOCP could improve the strength of LFC by 23% during the initial curing days. Utilizing the optimal proportions of POC and POCP could enhance the residual strengths of LFC. Therefore, POC has the potential to be utilized as a fine aggregate and cementitious material to produce sustainable concrete. Keyword : palm oil clinker, sand replacement material, foamed concrete, durability performance