Shuhan Cai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shuhan Cai has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Zhiyong Peng
Department of Critical Care Medicine, Zhongnan Hospital of Wuhan University, Wuhan, China
3 shared publications Xiao Yang
Department of Critical Care Medicine, Zhongnan Hospital of Wuhan University, Wuhan, China
2 shared publicationsAihua Qin
1 shared publicationBo Hu
1 shared publication- Bo Hu
Department of Critical Care Medicine, Zhongnan Hospital of Wuhan University, Wuhan, 430071, Hubei, China
1 shared publication Chang Hu
Department of Critical Care Medicine, Zhongnan Hospital of Wuhan University, Wuhan, Hubei, China
1 shared publication
Latest Publications
- Open Access
- 20 November 2026
- Published by Springer Nature in BMC Anesthesiology
Predictive value of postoperative serum Annexin-A1 for cardiac surgery-associated acute kidney injury in ICU patients: a prospective cohort study
- 20 November 2026
- Published by Springer Nature in BMC Anesthesiology
Open AccessPredictive value of postoperative serum Annexin-A1 for cardiac surgery-associated acute kidney injury in ICU patients: a prospective cohort study
- Open Access
- 25 June 2024
- Published by Elsevier in Journal of Intensive Medicine
- Vol. 4 (4) , 526-536
Association between hyperglycemia at ICU admission and postoperative acute kidney injury in patients undergoing cardiac surgery: Analysis of the MIMIC-IV database
- 25 June 2024
- Published by Elsevier in Journal of Intensive Medicine
- Vol. 4 (4) , 526-536
Open AccessAssociation between hyperglycemia at ICU admission and postoperative acute kidney injury in patients undergoing cardiac surgery: Analysis of the MIMIC-IV database
- Open Access
- 1 December 2022
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 22 (1) , 1-12
Comparison of assessment of diaphragm function using speckle tracking between patients with successful and failed weaning: a multicentre, observational, pilot study
Background: Diaphragmatic ultrasound has been increasingly used to evaluate diaphragm function. However, current diaphragmatic ultrasound parameters provide indirect estimates of diaphragmatic contractile function, and the predictive value is controversial. Two-dimensional (2D) speckle tracking is an effective technology for measuring tissue deformation and can be used to measure diaphragm longitudinal strain (DLS) to assess diaphragm function. The purpose of this study was to determine the feasibility and reproducibility of DLS quantification by 2D speckle tracking and to determine whether maximal DLS could be used to predict weaning outcomes. Methods: This study was performed in the intensive care unit of two teaching hospitals, and was divided into two studies. Study A was a prospective study to evaluate the feasibility, reliability, and repeatability of speckle tracking in assessing DLS in healthy subjects and mechanically ventilated patients. Study B was a multicentre retrospective study to assess the use of maximal DLS measured by speckle tracking in predicting weaning outcomes. Results: Twenty-five healthy subjects and twenty mechanically ventilated patients were enrolled in Study A. Diaphragmatic speckle tracking was easily accessible. The intra- and interoperator reliability were good to excellent under conditions of eupnoea, deep breathing, and mechanical ventilation. The intraclass correlation coefficient (ICC) ranged from 0.78 to 0.95. Ninety-six patients (fifty-nine patients were successfully weaned) were included in Study B. DLS exhibited a fair linear relationship with both the diaphragmatic thickening fraction (DTF) (R2 = 0.73, p < 0.0001) and diaphragmatic excursion (DE) (R2 = 0.61, p < 0.0001). For the prediction of successful weaning, the areas under the ROC curves of DLS, diaphragmatic thickening fraction DTF, RSBI, and DE were 0.794, 0.794, 0.723, and 0.728, respectively. The best cut-off value for predicting the weaning success of DLS was less than -21%, which had the highest sensitivity of 89.19% and specificity of 64.41%. Conclusions: Diaphragmatic strain quantification using speckle tracking is easy to obtain in healthy subjects and mechanically ventilated patients and has a high predictive value for mechanical weaning. However, this method offers no advantage over RSBI. Future research should assess its value as a predictor of weaning. Trial registration: This study was registered in the Chinese Clinical Trial Register (ChiCTR), ChiCTR2100049816. Registered 10 August 2021. http://www.chictr.org.cn/showproj.aspx?proj=131790
- 1 December 2022
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 22 (1) , 1-12
Open AccessComparison of assessment of diaphragm function using speckle tracking between patients with successful and failed weaning: a multicentre, observational, pilot study
Background: Diaphragmatic ultrasound has been increasingly used to evaluate diaphragm function. However, current diaphragmatic ultrasound parameters provide indirect estimates of diaphragmatic contractile function, and the predictive value is controversial. Two-dimensional (2D) speckle tracking is an effective technology for measuring tissue deformation and can be used to measure diaphragm longitudinal strain (DLS) to assess diaphragm function. The purpose of this study was to determine the feasibility and reproducibility of DLS quantification by 2D speckle tracking and to determine whether maximal DLS could be used to predict weaning outcomes. Methods: This study was performed in the intensive care unit of two teaching hospitals, and was divided into two studies. Study A was a prospective study to evaluate the feasibility, reliability, and repeatability of speckle tracking in assessing DLS in healthy subjects and mechanically ventilated patients. Study B was a multicentre retrospective study to assess the use of maximal DLS measured by speckle tracking in predicting weaning outcomes. Results: Twenty-five healthy subjects and twenty mechanically ventilated patients were enrolled in Study A. Diaphragmatic speckle tracking was easily accessible. The intra- and interoperator reliability were good to excellent under conditions of eupnoea, deep breathing, and mechanical ventilation. The intraclass correlation coefficient (ICC) ranged from 0.78 to 0.95. Ninety-six patients (fifty-nine patients were successfully weaned) were included in Study B. DLS exhibited a fair linear relationship with both the diaphragmatic thickening fraction (DTF) (R2 = 0.73, p < 0.0001) and diaphragmatic excursion (DE) (R2 = 0.61, p < 0.0001). For the prediction of successful weaning, the areas under the ROC curves of DLS, diaphragmatic thickening fraction DTF, RSBI, and DE were 0.794, 0.794, 0.723, and 0.728, respectively. The best cut-off value for predicting the weaning success of DLS was less than -21%, which had the highest sensitivity of 89.19% and specificity of 64.41%. Conclusions: Diaphragmatic strain quantification using speckle tracking is easy to obtain in healthy subjects and mechanically ventilated patients and has a high predictive value for mechanical weaning. However, this method offers no advantage over RSBI. Future research should assess its value as a predictor of weaning. Trial registration: This study was registered in the Chinese Clinical Trial Register (ChiCTR), ChiCTR2100049816. Registered 10 August 2021. http://www.chictr.org.cn/showproj.aspx?proj=131790
- Open Access
- 23 November 2020
- Published by Wolters Kluwer Health in Shock
- Vol. 56 (2) , 200-205
Findings and Prognostic Value of Lung Ultrasonography in Coronal Virus Disease 2019 (COVID-19) Pneumonia
Purpose: We used lung ultrasonography to identify features of COVID-19 pneumonia and to evaluate the prognostic value. Patients and Methods: We performed lung ultrasonography on 48 COVID-19 patients in an intensive care unit (ICU) (Wuhan, China) using a 12-zone method. The associations between lung ultrasonography score, PaO2/FiO2, APACHE II, SOFA, and PaCO2 with 28-day mortality were analyzed and the receiver operator characteristic curve was plotted. Results: 25.9% areas in all scanning zones presented with B7 lines and 23.5% with B3 lines (B-pattern) on lung ultrasonography; 13% areas with confluent B lines (B-pattern), 24.9% in areas with consolidations, and 9.9% in areas with A lines. Pleural effusion was observed in 2.8% of areas. Lung ultrasonography score was negatively correlated with PaO2/FiO2 (n = 48, r = −0.498, P < 0.05) and positively correlated with APACHE II (n = 48, r = 0.435, P < 0.05). Lung ultrasonography score was independently associated with 28-day mortality. The areas under receiver operator characteristic curves of lung ultrasonography score were 0.735 (95% CI: 0.586–0.844). The sensitivity, specificity, and cutoff values were 0.833, 0.722, and 22.5, respectively. Conclusions: Lung ultrasonography could be used to assess the severity of COVID-19 pneumonia, and it could also reveal the pathological signs of the disease. The lung ultrasonography score on ICU admission was independently related to the ICU 28-day mortality.
- 23 November 2020
- Published by Wolters Kluwer Health in Shock
- Vol. 56 (2) , 200-205
Open AccessFindings and Prognostic Value of Lung Ultrasonography in Coronal Virus Disease 2019 (COVID-19) Pneumonia
Purpose: We used lung ultrasonography to identify features of COVID-19 pneumonia and to evaluate the prognostic value. Patients and Methods: We performed lung ultrasonography on 48 COVID-19 patients in an intensive care unit (ICU) (Wuhan, China) using a 12-zone method. The associations between lung ultrasonography score, PaO2/FiO2, APACHE II, SOFA, and PaCO2 with 28-day mortality were analyzed and the receiver operator characteristic curve was plotted. Results: 25.9% areas in all scanning zones presented with B7 lines and 23.5% with B3 lines (B-pattern) on lung ultrasonography; 13% areas with confluent B lines (B-pattern), 24.9% in areas with consolidations, and 9.9% in areas with A lines. Pleural effusion was observed in 2.8% of areas. Lung ultrasonography score was negatively correlated with PaO2/FiO2 (n = 48, r = −0.498, P < 0.05) and positively correlated with APACHE II (n = 48, r = 0.435, P < 0.05). Lung ultrasonography score was independently associated with 28-day mortality. The areas under receiver operator characteristic curves of lung ultrasonography score were 0.735 (95% CI: 0.586–0.844). The sensitivity, specificity, and cutoff values were 0.833, 0.722, and 22.5, respectively. Conclusions: Lung ultrasonography could be used to assess the severity of COVID-19 pneumonia, and it could also reveal the pathological signs of the disease. The lung ultrasonography score on ICU admission was independently related to the ICU 28-day mortality.