Xiaojian Shi
Xiaojian Shi has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Jiajie Yang
Nantong Haimen Peoples Hospital, Nantong, China
2 shared publications - Kaibing Shi
Nantong Haimen Peoples Hosp, 1201 Beijing Rd, Nantong 226100, Jiangsu, Peoples R China
2 shared publications Chao Qin
Nantong Haimen Peoples Hosp, 1201 Beijing Rd, Nantong 226100, Jiangsu, Peoples R China
1 shared publication- Chunxi Yang
Department of Bone and Joint Surgery, Department of Orthopedic, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
1 shared publication - Jiajia Lu
Department of Orthopedic Trauma, Shanghai Fourth People’s Hospital, School of Medicine, Tongji University
1 shared publication Jianhua Lu
Nantong Haimen Peoples Hosp, 1201 Beijing Rd, Nantong 226100, Jiangsu, Peoples R China
1 shared publication
Latest Publications
- Open Access
- 1 July 2024
- Published by IOP Publishing in Materials Research Express
- Vol. 11 (7) , 075404
Investigating mechanical properties of 3D printed porous titanium scaffolds for bone tissue engineering
Objective. Three-dimensional (3D) printed porous titanium scaffolds serve as a bone tissue engineering technology that offers a promising solution for addressing bone defects. The scaffold’s pore structure offers structural support and facilitates the proliferation of bone cells. Therefore, investigating the aperture and pore shape is of crucial for the development of 3D printed porous titanium scaffolds. Methods. Ti6Al4V scaffolds with the specified structure were fabricated using selective laser melting (SLM) technology. The scaffolds comprised fifteen cylindrical models measuring 20 mm in diameter and 20 mm in height. These models featured five scaffold shapes: imitation diamond-60°, imitation diamond-90°, imitation diamond-120°, regular tetrahedron and regular hexahedron. Each of these structural shapes was characterized by three different aperture sizes (400 μm, 600 μm and 800 μm). The porosity and mechanical properties of Ti6Al4V scaffolds were examined. Results. The measured porosity of Ti6Al4V scaffolds varied between 56.50% and 95.28%. The porosity increased with the size of the aperture. The mechanical properties tests revealed that, for identical apertures, the compressive strength and torsional strength were influenced by the configuration of the unit structure. Furthermore, the positive and lateral compressive strength as well as torsional strength of various unit structures exhibited distinct advantages and disadvantages. Within a uniform unit structure shape, the compressive strength and torsional strength were found to be correlated with the size of apertures, indicating that larger apertures result in decreased compressive and torsional strength. Conclusion. The configuration of the aperture and the shape of the pore were identified as significant factors that influenced the compressive strength. The compressive strength of Ti6Al4V scaffolds with various unit structure shapes exhibited both advantages and disadvantages when subjected to positive, lateral, and torsional forces. The enlarged aperture augmented the scaffold’s porosity while diminishing its compressive and torsional strength.
- 1 July 2024
- Published by IOP Publishing in Materials Research Express
- Vol. 11 (7) , 075404
Open AccessInvestigating mechanical properties of 3D printed porous titanium scaffolds for bone tissue engineering
Objective. Three-dimensional (3D) printed porous titanium scaffolds serve as a bone tissue engineering technology that offers a promising solution for addressing bone defects. The scaffold’s pore structure offers structural support and facilitates the proliferation of bone cells. Therefore, investigating the aperture and pore shape is of crucial for the development of 3D printed porous titanium scaffolds. Methods. Ti6Al4V scaffolds with the specified structure were fabricated using selective laser melting (SLM) technology. The scaffolds comprised fifteen cylindrical models measuring 20 mm in diameter and 20 mm in height. These models featured five scaffold shapes: imitation diamond-60°, imitation diamond-90°, imitation diamond-120°, regular tetrahedron and regular hexahedron. Each of these structural shapes was characterized by three different aperture sizes (400 μm, 600 μm and 800 μm). The porosity and mechanical properties of Ti6Al4V scaffolds were examined. Results. The measured porosity of Ti6Al4V scaffolds varied between 56.50% and 95.28%. The porosity increased with the size of the aperture. The mechanical properties tests revealed that, for identical apertures, the compressive strength and torsional strength were influenced by the configuration of the unit structure. Furthermore, the positive and lateral compressive strength as well as torsional strength of various unit structures exhibited distinct advantages and disadvantages. Within a uniform unit structure shape, the compressive strength and torsional strength were found to be correlated with the size of apertures, indicating that larger apertures result in decreased compressive and torsional strength. Conclusion. The configuration of the aperture and the shape of the pore were identified as significant factors that influenced the compressive strength. The compressive strength of Ti6Al4V scaffolds with various unit structure shapes exhibited both advantages and disadvantages when subjected to positive, lateral, and torsional forces. The enlarged aperture augmented the scaffold’s porosity while diminishing its compressive and torsional strength.
- Open Access
- 18 July 2023
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 109 (11) , 3677-3678
Trabecular metal versus non-trabecular metal acetabular components for acetabular revision surgery
An abstract is unavailable. This article is available as a PDF only.
- 18 July 2023
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 109 (11) , 3677-3678
Open AccessTrabecular metal versus non-trabecular metal acetabular components for acetabular revision surgery
An abstract is unavailable. This article is available as a PDF only.
- Open Access
- 2 August 2021
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 22 (1) , 1-11
Design and analysis of three-dimensional printing of a porous titanium scaffold
Objective: Mechanic strength, pore morphology and size are key factors for the three-dimensional (3D) printing of porous titanium scaffolds, therefore, developing optimal structure for the 3D printed titanium scaffold to fill bone defects in knee joints is instructive and important. Methods: Structural models of titanium scaffolds with fifteen different pore unit were designed with 3D printing computer software; five different scaffold shapes were designed: imitation diamond-60°, imitation diamond-90°, imitation diamond-120°, regular tetrahedron and regular hexahedron. Each structural shape was evaluated with three pore sizes (400, 600 and 800 μm), and fifteen types of cylindrical models (size: 20 mm; height: 20 mm). Autodesk Inventor software was used to determine the strength and safety of the models by simulating simple strength acting on the knee joints. We analyzed the data and found suitable models for the design of 3D printing of porous titanium scaffolds. Results: Fifteen different types of pore unit structural models were evaluated under positive pressure and lateral pressure; the compressive strength reduced when the pore size increased. Under torsional pressure, the strengths of the imitation diamond structure were similar when the pore size increased, and the strengths of the regular tetrahedron and regular hexahedron structures reduced when the pore size increased. In each case, the compressive strength of the regular hexahedron structure was highest, that of the regular tetrahedron was second highest, and that of the imitation diamond structure was relatively low. Fifteen types of cylindrical models under a set force were evaluated, and the sequence of comprehensive compressive strength, from strong to weak was: regular hexahedron > regular tetrahedron > imitation diamond-120° > imitation diamond-90° > imitation diamond-60°. The compressive strength of cylinder models was higher when the pore size was smaller. Conclusion: The pore size and pore morphology were important factors influencing the compressive strength. The strength of each structure reduced when the pore size (400, 600 and 800 μm) increased. The models of regular hexahedron, regular tetrahedron and imitation diamond-120°appeared to meet the conditions of large pore sizes and high compressive strength.
- 2 August 2021
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 22 (1) , 1-11
Open AccessDesign and analysis of three-dimensional printing of a porous titanium scaffold
Objective: Mechanic strength, pore morphology and size are key factors for the three-dimensional (3D) printing of porous titanium scaffolds, therefore, developing optimal structure for the 3D printed titanium scaffold to fill bone defects in knee joints is instructive and important. Methods: Structural models of titanium scaffolds with fifteen different pore unit were designed with 3D printing computer software; five different scaffold shapes were designed: imitation diamond-60°, imitation diamond-90°, imitation diamond-120°, regular tetrahedron and regular hexahedron. Each structural shape was evaluated with three pore sizes (400, 600 and 800 μm), and fifteen types of cylindrical models (size: 20 mm; height: 20 mm). Autodesk Inventor software was used to determine the strength and safety of the models by simulating simple strength acting on the knee joints. We analyzed the data and found suitable models for the design of 3D printing of porous titanium scaffolds. Results: Fifteen different types of pore unit structural models were evaluated under positive pressure and lateral pressure; the compressive strength reduced when the pore size increased. Under torsional pressure, the strengths of the imitation diamond structure were similar when the pore size increased, and the strengths of the regular tetrahedron and regular hexahedron structures reduced when the pore size increased. In each case, the compressive strength of the regular hexahedron structure was highest, that of the regular tetrahedron was second highest, and that of the imitation diamond structure was relatively low. Fifteen types of cylindrical models under a set force were evaluated, and the sequence of comprehensive compressive strength, from strong to weak was: regular hexahedron > regular tetrahedron > imitation diamond-120° > imitation diamond-90° > imitation diamond-60°. The compressive strength of cylinder models was higher when the pore size was smaller. Conclusion: The pore size and pore morphology were important factors influencing the compressive strength. The strength of each structure reduced when the pore size (400, 600 and 800 μm) increased. The models of regular hexahedron, regular tetrahedron and imitation diamond-120°appeared to meet the conditions of large pore sizes and high compressive strength.