Satoshi Nomura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Satoshi Nomura has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Akihiko Hiyama
Department of Orthopaedic Surgery, Tokai University School of Medicine, Kanagawa, Japan
5 shared publications - Masahiko Watanabe
Department of Orthopaedic Surgery, Tokai University School of Medicine, Kanagawa, Japan
5 shared publications - Daisuke Sakai
Department of Orthopaedic Surgery, Tokai University School of Medicine, Isehara, Japan
4 shared publications - Hiroyuki Katoh
Department of Orthopaedic Surgery, Tokai University School of Medicine, Kanagawa, Japan
4 shared publications - Masato Sato
Department of Orthopaedic Surgery, Tokai University School of Medicine, Kanagawa, Japan
2 shared publications - Taku Ukai
Department of Orthopaedic Surgery, Surgical Science, Tokai University School of Medicine, Isehara, Japan
1 shared publication
Latest Publications
- Open Access
- 3 November 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (21) , 6914
Assessing Procedural Accuracy in Lateral Spine Surgery: A Retrospective Analysis of Percutaneous Pedicle Screw Placement with Intraoperative CT Navigation
Percutaneous pedicle screws (PPSs) are commonly used in posterior spinal fusion to treat spine conditions such as trauma, tumors, and degenerative diseases. Precise PPS placement is essential in preventing neurological complications and improving patient outcomes. Recent studies have suggested that intraoperative computed tomography (CT) navigation can reduce the dependence on extensive surgical expertise for achieving accurate PPS placement. However, more comprehensive documentation is needed regarding the procedural accuracy of lateral spine surgery (LSS). In this retrospective study, we investigated patients who underwent posterior instrumentation with PPSs in the thoracic to lumbar spine, utilizing an intraoperative CT navigation system, between April 2019 and September 2023. The system’s methodology involved real-time CT-based guidance during PPS placement, ensuring precision. Our study included 170 patients (151 undergoing LLIF procedures and 19 trauma patients), resulting in 836 PPS placements. The overall PPS deviation rate, assessed using the Ravi scale, was 2.5%, with a notably higher incidence of deviations observed in the thoracic spine (7.4%) compared to the lumbar spine (1.9%). Interestingly, we found no statistically significant difference in screw deviation rates between upside and downside PPS placements. Regarding perioperative complications, three patients experienced issues related to intraoperative CT navigation. The observed higher rate of inaccuracies in the thoracic spine suggests that various factors may contribute to these differences in accuracy, including screw size and anatomical variations. Further research is required to refine PPS insertion techniques, particularly in the context of LSS. In conclusion, this retrospective study sheds light on the challenges associated with achieving precise PPS placement in the lateral decubitus position, with a significantly higher deviation rate observed in the thoracic spine compared to the lumbar spine. This study emphasizes the need for ongoing research to improve PPS insertion techniques, leading to enhanced patient outcomes in spine surgery.
- 3 November 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (21) , 6914
Open AccessAssessing Procedural Accuracy in Lateral Spine Surgery: A Retrospective Analysis of Percutaneous Pedicle Screw Placement with Intraoperative CT Navigation
Percutaneous pedicle screws (PPSs) are commonly used in posterior spinal fusion to treat spine conditions such as trauma, tumors, and degenerative diseases. Precise PPS placement is essential in preventing neurological complications and improving patient outcomes. Recent studies have suggested that intraoperative computed tomography (CT) navigation can reduce the dependence on extensive surgical expertise for achieving accurate PPS placement. However, more comprehensive documentation is needed regarding the procedural accuracy of lateral spine surgery (LSS). In this retrospective study, we investigated patients who underwent posterior instrumentation with PPSs in the thoracic to lumbar spine, utilizing an intraoperative CT navigation system, between April 2019 and September 2023. The system’s methodology involved real-time CT-based guidance during PPS placement, ensuring precision. Our study included 170 patients (151 undergoing LLIF procedures and 19 trauma patients), resulting in 836 PPS placements. The overall PPS deviation rate, assessed using the Ravi scale, was 2.5%, with a notably higher incidence of deviations observed in the thoracic spine (7.4%) compared to the lumbar spine (1.9%). Interestingly, we found no statistically significant difference in screw deviation rates between upside and downside PPS placements. Regarding perioperative complications, three patients experienced issues related to intraoperative CT navigation. The observed higher rate of inaccuracies in the thoracic spine suggests that various factors may contribute to these differences in accuracy, including screw size and anatomical variations. Further research is required to refine PPS insertion techniques, particularly in the context of LSS. In conclusion, this retrospective study sheds light on the challenges associated with achieving precise PPS placement in the lateral decubitus position, with a significantly higher deviation rate observed in the thoracic spine compared to the lumbar spine. This study emphasizes the need for ongoing research to improve PPS insertion techniques, leading to enhanced patient outcomes in spine surgery.
- Open Access
- 2 March 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (5) , 1374
Comparative Study of Cage Subsidence in Single-Level Lateral Lumbar Interbody Fusion
We investigated the incidence and clinical features of cage subsidence after single-level lateral lumbar interbody fusion (LLIF). We studied a retrospective cohort of 59 patients (34 males, 25 females; mean age, 68.9 years) who received single-level LLIF. Patients were classified into subsidence and no-subsidence groups. Cage subsidence was defined as any violation of either endplate, classified using radiographs and computed tomography (CT) images. After one year, we compared patient characteristics, surgical parameters, radiological findings, pain scores, and fusion status. We also compared the Hounsfield unit (HU) endplate value obtained on CT preoperatively. Twenty patients (33.9%) had radiographic evidence of interbody cage subsidence. There were significant differences between the subsidence and no-subsidence groups in sex, cage height, fusion rate, and average HU value of both endplates (p < 0.05). There were no significant differences in age, height, weight, or body mass index. Moreover, there were no significant differences in global alignment and Numerical Rating Scale change in low back pain, leg pain, and numbness. Despite suggestions that patients with lower HU values might develop cage subsidence, our results showed that cage subsidence after single-level LLIF was not associated with low back pain, leg pain, or numbness one year post-operation.
- 2 March 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (5) , 1374
Open AccessComparative Study of Cage Subsidence in Single-Level Lateral Lumbar Interbody Fusion
We investigated the incidence and clinical features of cage subsidence after single-level lateral lumbar interbody fusion (LLIF). We studied a retrospective cohort of 59 patients (34 males, 25 females; mean age, 68.9 years) who received single-level LLIF. Patients were classified into subsidence and no-subsidence groups. Cage subsidence was defined as any violation of either endplate, classified using radiographs and computed tomography (CT) images. After one year, we compared patient characteristics, surgical parameters, radiological findings, pain scores, and fusion status. We also compared the Hounsfield unit (HU) endplate value obtained on CT preoperatively. Twenty patients (33.9%) had radiographic evidence of interbody cage subsidence. There were significant differences between the subsidence and no-subsidence groups in sex, cage height, fusion rate, and average HU value of both endplates (p < 0.05). There were no significant differences in age, height, weight, or body mass index. Moreover, there were no significant differences in global alignment and Numerical Rating Scale change in low back pain, leg pain, and numbness. Despite suggestions that patients with lower HU values might develop cage subsidence, our results showed that cage subsidence after single-level LLIF was not associated with low back pain, leg pain, or numbness one year post-operation.
- Open Access
- 15 January 2022
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 17 (1) , 1-8
The combination of intraoperative CT navigation and C-arm fluoroscopy for INFIX and percutaneous TITS screw placement in the treatment of pelvic ring injury: technical note
Background: The subcutaneous screw rod system, commonly known as the internal pelvic fixator (INFIX), is useful in managing unstable pelvic ring fractures. Conventional INFIX and transiliac–transsacral (TITS) screw techniques are performed using C-arm fluoroscopy. There have been problems with medical exposure and screw insertion accuracy with these techniques. This work describes new INFIX and TITS techniques using intraoperative computed tomography (CT) navigation and C-arm fluoroscopy for pelvic ring fracture. Methods: A typical case is presented in this study. An 86-year-old woman suffered from an unstable pelvic ring fracture due to a fall from a height. INFIX and TITS screw fixation with intraoperative CT navigation were selected to optimize surgical invasiveness and proper implant placement. Results: The patient was placed in a supine position on a Jackson table. An intraoperative CT navigation was imaged, and screws were inserted under the navigation. Postoperative X-rays and CT confirmed that the screw was inserted correctly. This technique was less invasive to the patient and had little radiation exposure to the surgeon. Rehabilitation of walking practice was started early after the surgery, and she was able to walk with the assistance of a walker by the time of transfer. Conclusions: The technique employed in our case study has the cumulative advantages of safety, accuracy, and reduced radiation exposure, together with the inherent advantages of functional outcomes of previously reported INFIX and TITS screw techniques. Further experience with this approach will refine this technique to overcome its limitations and facilitate its wider use.
- 15 January 2022
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 17 (1) , 1-8
Open AccessThe combination of intraoperative CT navigation and C-arm fluoroscopy for INFIX and percutaneous TITS screw placement in the treatment of pelvic ring injury: technical note
Background: The subcutaneous screw rod system, commonly known as the internal pelvic fixator (INFIX), is useful in managing unstable pelvic ring fractures. Conventional INFIX and transiliac–transsacral (TITS) screw techniques are performed using C-arm fluoroscopy. There have been problems with medical exposure and screw insertion accuracy with these techniques. This work describes new INFIX and TITS techniques using intraoperative computed tomography (CT) navigation and C-arm fluoroscopy for pelvic ring fracture. Methods: A typical case is presented in this study. An 86-year-old woman suffered from an unstable pelvic ring fracture due to a fall from a height. INFIX and TITS screw fixation with intraoperative CT navigation were selected to optimize surgical invasiveness and proper implant placement. Results: The patient was placed in a supine position on a Jackson table. An intraoperative CT navigation was imaged, and screws were inserted under the navigation. Postoperative X-rays and CT confirmed that the screw was inserted correctly. This technique was less invasive to the patient and had little radiation exposure to the surgeon. Rehabilitation of walking practice was started early after the surgery, and she was able to walk with the assistance of a walker by the time of transfer. Conclusions: The technique employed in our case study has the cumulative advantages of safety, accuracy, and reduced radiation exposure, together with the inherent advantages of functional outcomes of previously reported INFIX and TITS screw techniques. Further experience with this approach will refine this technique to overcome its limitations and facilitate its wider use.
- 1 November 2021
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 93, 75-81
Intraoperative computed tomography-guided navigation versus fluoroscopy for single-position surgery after lateral lumbar interbody fusion
- 1 November 2021
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 93, 75-81
Intraoperative computed tomography-guided navigation versus fluoroscopy for single-position surgery after lateral lumbar interbody fusion