JGJoaquim Goffin

Joaquim Goffin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Joaquim Goffin has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Study on impact of robotic-assisted orthopaedic industrial noise (SIREN)

    by Joaquim Goffin, Emma MacRae, Luke Farrow, Duncan Whittaker, James Dixon, Iain Rankin, Anjan Krishnamurthy, Iain Stevenson

    Introduction: The aim of this study was to evaluate noise exposure to the operating room staff consisting of the surgeon, assistant, anaesthetist and Mako Product Specialist (MPS) during Mako robotic-arm assisted total knee arthroplasty (TKA) and total hip arthroplasty (THA). We aimed to determine whether employees were exposed to noise at or above a lower exposure action value (LEAV) set out by the Noise at Work Regulations 2005, Health and Safety Executive (HSE), UK. Materials and methods: We prospectively recorded intra-operative noise levels in Mako robotic-arm assisted TKA and THA over a period of two months using the MicW i436 connected to an iOS device (Apple), using the Sound Level Meter App (iOS) by the National Institute for Occupation Safety and Health (NIOSH). Data obtained was then used to calculate “worst case” daily exposure value to assess if sound levels were compliant with UK guidelines. Comparison between operating room staff groups was performed with ANOVA testing. Results: A total of 19 TKA and 11 THA operations were recorded. During TKA, for the primary surgeon and the assistant, the equivalent continuous sound pressure level (LAeq) was over 80 dB, exceeding the LEAV set out by the Noise at Work Regulations by HSE. During THA, the average LAeq and peak sound pressure levels did not exceed the LEAV. The calculated daily exposure for the primary surgeon in TKA was 82 dB. A Tukey post hoc test revealed that LAeq was statistically significantly lower in the anaesthetist and MPS (p < .001) compared to the primary surgeon and assistant in both TKA and THA. Conclusions: Operating room staff, particularly the primary surgeon and assistant are exposed to significant levels of noise during Mako robotic-arm assisted TKA and THA. Formal assessments should be performed to further assess the risk of noise induced hearing loss in robotic-arm assisted arthroplasty.


  • Open Access

    Surgical Rib Fracture Fixation: Early Operative Intervention Improves Outcomes

    by James Dixon, Iain Rankin, Nicholas Diston, Joaquim Goffin, Iain Stevenson

    James Dixon, M.B.Ch.B., Iain Rankin, M.B.Ch.B., Ph.D., Nicholas Diston, B.Sc., Joaquim Goffin, M.B.Ch.B., B.Sc., Iain Stevenson, M.B.Ch.B., F.R.C.S.. J Chest Surg 2024;57:120-5. https://doi.org/10.5090/jcs.23.095


  • The use of digital tomosynthesis in suspected scaphoid fractures

    by Joaquim Stanislas Olivier Goffin, Iain A Rankin, Juan De Dios Robinson

    We report a retrospective observational series of patients undergoing digital tomosynthesis (DTS) for suspected scaphoid fractures. With a specificity and sensitivity of 100%, DTS demonstrates the potential to be an excellent tool in the diagnosis of occult scaphoid fractures.


  • Stress shielding of the proximal humerus in stemless anatomic total shoulder arthroplasty

    by Iain A Rankin, Joaquim Goffin, L A Kash Khan, David Cairns, Scott L Barker, Kapil Kumar

    Background: This study aimed to assess the radiographic proximal humerus bony adaptations to stress shielding and associated clinical outcomes following stemless total shoulder arthroplasty. Methods: A retrospective review of all patients who underwent stemless total shoulder arthroplasty surgery at our centre from 2010 to 2020 was performed. Results: In total, 115 stemless total shoulder arthroplasty utilising a single implant design with a minimum one-year follow-up were identified over a 10-year period. The median follow-up was 3.5 years (range: 1–8.9 years). Evidence of stress shielding was observed in 20 cases (17%), (9 mild (8%), 0 moderate (0%), 11 severe (9%). No significant differences were seen between stress shielding and gender, body mass index, post-operative range-of-motion, patient satisfaction, or Oxford shoulder score. No significant differences were seen between the operative technique and stress shielding. No cases had evidence of humeral lucency. In total, 24 cases (21%) had evidence of glenoid lucency of Lazarus grade 0–3. No cases had Lazarus grades 4 or 5. There was no association between stress shielding and humeral lucency, glenoid lucency, or revision procedure. Discussion: Stress shielding in this study occurred at lower rates than anticipated following stemless total shoulder arthroplasty and was not associated with radiographic evidence of lucency, revision procedures, or adverse effect on clinical outcome measures.


  • Evaluation of sound levels in elective orthopaedic theatres during primary hip and knee arthroplasty

    by Joaquim S.O. Goffin, David R.W. MacDonald, David Neilly, Christopher Munro, George Patrick Ashcroft