Joaquim Goffin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Joaquim Goffin has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Iain Rankin
Aberdeen Royal Infirmary, Foresterhill Health Campus, Aberdeen AB25 2ZN, UK
2 shared publications Anjan Krishnamurthy
Grampian Orthopaedics, Woodend Hospital, Aberdeen, UK
1 shared publicationChristopher Munro
Department of Orthopaedics, Woodend General Hospital, Eday Road, Aberdeen, UK
1 shared publicationDavid Cairns
Department of Trauma and Orthopaedics, Aberdeen Upper Limb Unit, Woodend Hospital, Aberdeen, UK
1 shared publication- David Neilly
Department of Orthopaedics, Woodend General Hospital, Eday Road, Aberdeen, UK
1 shared publication David R.W. MacDonald
Department of Orthopaedics, Woodend General Hospital, Eday Road, Aberdeen, UK
1 shared publication
Latest Publications
- Open Access
- 5 April 2024
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 144 (5) , 2413-2420
Study on impact of robotic-assisted orthopaedic industrial noise (SIREN)
Introduction: The aim of this study was to evaluate noise exposure to the operating room staff consisting of the surgeon, assistant, anaesthetist and Mako Product Specialist (MPS) during Mako robotic-arm assisted total knee arthroplasty (TKA) and total hip arthroplasty (THA). We aimed to determine whether employees were exposed to noise at or above a lower exposure action value (LEAV) set out by the Noise at Work Regulations 2005, Health and Safety Executive (HSE), UK. Materials and methods: We prospectively recorded intra-operative noise levels in Mako robotic-arm assisted TKA and THA over a period of two months using the MicW i436 connected to an iOS device (Apple), using the Sound Level Meter App (iOS) by the National Institute for Occupation Safety and Health (NIOSH). Data obtained was then used to calculate “worst case” daily exposure value to assess if sound levels were compliant with UK guidelines. Comparison between operating room staff groups was performed with ANOVA testing. Results: A total of 19 TKA and 11 THA operations were recorded. During TKA, for the primary surgeon and the assistant, the equivalent continuous sound pressure level (LAeq) was over 80 dB, exceeding the LEAV set out by the Noise at Work Regulations by HSE. During THA, the average LAeq and peak sound pressure levels did not exceed the LEAV. The calculated daily exposure for the primary surgeon in TKA was 82 dB. A Tukey post hoc test revealed that LAeq was statistically significantly lower in the anaesthetist and MPS (p < .001) compared to the primary surgeon and assistant in both TKA and THA. Conclusions: Operating room staff, particularly the primary surgeon and assistant are exposed to significant levels of noise during Mako robotic-arm assisted TKA and THA. Formal assessments should be performed to further assess the risk of noise induced hearing loss in robotic-arm assisted arthroplasty.
- 5 April 2024
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 144 (5) , 2413-2420
Open AccessStudy on impact of robotic-assisted orthopaedic industrial noise (SIREN)
Introduction: The aim of this study was to evaluate noise exposure to the operating room staff consisting of the surgeon, assistant, anaesthetist and Mako Product Specialist (MPS) during Mako robotic-arm assisted total knee arthroplasty (TKA) and total hip arthroplasty (THA). We aimed to determine whether employees were exposed to noise at or above a lower exposure action value (LEAV) set out by the Noise at Work Regulations 2005, Health and Safety Executive (HSE), UK. Materials and methods: We prospectively recorded intra-operative noise levels in Mako robotic-arm assisted TKA and THA over a period of two months using the MicW i436 connected to an iOS device (Apple), using the Sound Level Meter App (iOS) by the National Institute for Occupation Safety and Health (NIOSH). Data obtained was then used to calculate “worst case” daily exposure value to assess if sound levels were compliant with UK guidelines. Comparison between operating room staff groups was performed with ANOVA testing. Results: A total of 19 TKA and 11 THA operations were recorded. During TKA, for the primary surgeon and the assistant, the equivalent continuous sound pressure level (LAeq) was over 80 dB, exceeding the LEAV set out by the Noise at Work Regulations by HSE. During THA, the average LAeq and peak sound pressure levels did not exceed the LEAV. The calculated daily exposure for the primary surgeon in TKA was 82 dB. A Tukey post hoc test revealed that LAeq was statistically significantly lower in the anaesthetist and MPS (p < .001) compared to the primary surgeon and assistant in both TKA and THA. Conclusions: Operating room staff, particularly the primary surgeon and assistant are exposed to significant levels of noise during Mako robotic-arm assisted TKA and THA. Formal assessments should be performed to further assess the risk of noise induced hearing loss in robotic-arm assisted arthroplasty.
- Open Access
- 16 January 2024
- Published by Korean Society for Thoracic and Cardiovascular Surgery in Journal of Chest Surgery
- Vol. 57 (2) , 120-125
Surgical Rib Fracture Fixation: Early Operative Intervention Improves Outcomes
James Dixon, M.B.Ch.B., Iain Rankin, M.B.Ch.B., Ph.D., Nicholas Diston, B.Sc., Joaquim Goffin, M.B.Ch.B., B.Sc., Iain Stevenson, M.B.Ch.B., F.R.C.S.. J Chest Surg 2024;57:120-5. https://doi.org/10.5090/jcs.23.095
- 16 January 2024
- Published by Korean Society for Thoracic and Cardiovascular Surgery in Journal of Chest Surgery
- Vol. 57 (2) , 120-125
Open AccessSurgical Rib Fracture Fixation: Early Operative Intervention Improves Outcomes
James Dixon, M.B.Ch.B., Iain Rankin, M.B.Ch.B., Ph.D., Nicholas Diston, B.Sc., Joaquim Goffin, M.B.Ch.B., B.Sc., Iain Stevenson, M.B.Ch.B., F.R.C.S.. J Chest Surg 2024;57:120-5. https://doi.org/10.5090/jcs.23.095
- 24 November 2023
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 49 (5) , 630-631
The use of digital tomosynthesis in suspected scaphoid fractures
We report a retrospective observational series of patients undergoing digital tomosynthesis (DTS) for suspected scaphoid fractures. With a specificity and sensitivity of 100%, DTS demonstrates the potential to be an excellent tool in the diagnosis of occult scaphoid fractures.
- 24 November 2023
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 49 (5) , 630-631
The use of digital tomosynthesis in suspected scaphoid fractures
We report a retrospective observational series of patients undergoing digital tomosynthesis (DTS) for suspected scaphoid fractures. With a specificity and sensitivity of 100%, DTS demonstrates the potential to be an excellent tool in the diagnosis of occult scaphoid fractures.
- 9 April 2023
- Published by SAGE Publications in Shoulder & Elbow
- Vol. 16 (5) , 493-500
Stress shielding of the proximal humerus in stemless anatomic total shoulder arthroplasty
Background: This study aimed to assess the radiographic proximal humerus bony adaptations to stress shielding and associated clinical outcomes following stemless total shoulder arthroplasty. Methods: A retrospective review of all patients who underwent stemless total shoulder arthroplasty surgery at our centre from 2010 to 2020 was performed. Results: In total, 115 stemless total shoulder arthroplasty utilising a single implant design with a minimum one-year follow-up were identified over a 10-year period. The median follow-up was 3.5 years (range: 1–8.9 years). Evidence of stress shielding was observed in 20 cases (17%), (9 mild (8%), 0 moderate (0%), 11 severe (9%). No significant differences were seen between stress shielding and gender, body mass index, post-operative range-of-motion, patient satisfaction, or Oxford shoulder score. No significant differences were seen between the operative technique and stress shielding. No cases had evidence of humeral lucency. In total, 24 cases (21%) had evidence of glenoid lucency of Lazarus grade 0–3. No cases had Lazarus grades 4 or 5. There was no association between stress shielding and humeral lucency, glenoid lucency, or revision procedure. Discussion: Stress shielding in this study occurred at lower rates than anticipated following stemless total shoulder arthroplasty and was not associated with radiographic evidence of lucency, revision procedures, or adverse effect on clinical outcome measures.
- 9 April 2023
- Published by SAGE Publications in Shoulder & Elbow
- Vol. 16 (5) , 493-500
Stress shielding of the proximal humerus in stemless anatomic total shoulder arthroplasty
Background: This study aimed to assess the radiographic proximal humerus bony adaptations to stress shielding and associated clinical outcomes following stemless total shoulder arthroplasty. Methods: A retrospective review of all patients who underwent stemless total shoulder arthroplasty surgery at our centre from 2010 to 2020 was performed. Results: In total, 115 stemless total shoulder arthroplasty utilising a single implant design with a minimum one-year follow-up were identified over a 10-year period. The median follow-up was 3.5 years (range: 1–8.9 years). Evidence of stress shielding was observed in 20 cases (17%), (9 mild (8%), 0 moderate (0%), 11 severe (9%). No significant differences were seen between stress shielding and gender, body mass index, post-operative range-of-motion, patient satisfaction, or Oxford shoulder score. No significant differences were seen between the operative technique and stress shielding. No cases had evidence of humeral lucency. In total, 24 cases (21%) had evidence of glenoid lucency of Lazarus grade 0–3. No cases had Lazarus grades 4 or 5. There was no association between stress shielding and humeral lucency, glenoid lucency, or revision procedure. Discussion: Stress shielding in this study occurred at lower rates than anticipated following stemless total shoulder arthroplasty and was not associated with radiographic evidence of lucency, revision procedures, or adverse effect on clinical outcome measures.
- 1 August 2022
- Published by Elsevier in The Surgeon
- Vol. 20 (4) , 225-230
Evaluation of sound levels in elective orthopaedic theatres during primary hip and knee arthroplasty
- 1 August 2022
- Published by Elsevier in The Surgeon
- Vol. 20 (4) , 225-230
Evaluation of sound levels in elective orthopaedic theatres during primary hip and knee arthroplasty