MKMichiko Kinoshita

Michiko Kinoshita

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Michiko Kinoshita has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Global growth, persistent hierarchies: A bibliometric and network analysis of international collaboration in anesthesiology (1996–2024)

    by Michiko Kinoshita, Katsuya Tanaka

    Background: Although international collaboration in anesthesiology has increased in recent decades, the evolution of global co-authorship networks and their influence on scholarly impact across the field remain insufficiently characterized. This study aimed to analyze temporal trends in international, national, and single-institution publications and their citation impact; characterize the evolving structure of the international collaboration network; and identify key contributors through network metrics. Methods: We conducted a bibliometric analysis of 1,95,955 articles published between 1996 and 2024 in the Scopus “Anesthesiology and Pain Medicine” category. Temporal trends were assessed across 3 distinct periods: 1996 to 2005, 2006 to 2015, and 2016 to 2024. Publications were categorized by collaboration type (international, national, or single institution) and analyzed for citation impact. Countries and collaborative ties are represented as nodes and links, respectively. Structural evolution was assessed using global metrics, and node-level centrality metrics and Gini coefficients were used to identify influential countries and assess collaboration disparities. Results: The share of international collaborative articles has more than doubled from 8.0% (1996–2005) to 17.1% (2016–2024). These articles consistently garnered approximately 2.5 times more citations per publication than those from single institutions. The collaboration network expanded substantially; participating countries increased from 117 (1996–2005) to 190 (2016–2024), and collaborative links surged from 585 (1996–2005) to 5245 (2016–2024). The network became denser and more clustered, with decreasing heterogeneity and stable centralization. Persistently high Gini coefficients for degree and betweenness centrality (range, 0.79–0.93) indicated a concentration of collaborative influence among dominant hub countries, including the United States, the United Kingdom, Germany, Canada, and Australia. Low Gini coefficients for closeness centrality (0.23–0.24) suggested equitable network access among most countries. Conclusions: International collaboration in anesthesiology increased substantially between 1996 and 2024, with collaborative articles consistently receiving more citations per publication than single-institution publications. The global collaboration network expanded and became more interconnected, while a small group of countries, primarily in North America and Europe, remained central. These findings illustrate the evolution and growing importance of international collaboration in anesthesiology over the past 3 decades.

  • Effects of spiral deflation and warming on cuff diameter, insertion force, extubation, and sealing performance in polyvinyl chloride-cuffed tracheal tubes

    by Hiroki Yonezawa, Michiko Kinoshita, Chiaki Murakami, Takako Ikezaki, Katsuya Tanaka

    Cuffed tracheal tubes are widely used in paediatric airway management, but passage through the relatively narrow subglottic airway may increase insertion resistance and risk mucosal trauma. This study evaluated whether spiral deflation (i.e. folding the cuff inward like an umbrella) and warming the tube could reduce cuff diameter and insertion force in a simulated trachea. Four commercially available polyvinyl chloride-cuffed tubes with an internal diameter of 5.0 mm (PORTEX ® (Smiths Medical International Ltd, Ashford, UK), Sheridan ® (Teleflex Inc., Morrisville, NC, USA), Shiley™ (Medtronic, Minneapolis, MN, USA), and VentiSeal™ (Flexicare Medical Ltd, Mountain Ash, UK)) were examined. Spiral deflation significantly reduced cuff diameter, with reductions of (mean difference, MD) −3.6 mm (95% confidence intervals, CI −4.5 to −2.7, P P P =0.001), and −4.9 mm (−6.0 to −3.9, P P =0.008), −0.34 N (−0.63 to −0.05, P =0.115), −0.49 N (−0.61 to −0.37, P P =0.028), respectively. Additional warming at 40°C further lowered insertion force, with reductions of (MD (CI)) −0.12 N (−0.19 to −0.05, P =0.020), −0.06 N (−0.08 to −0.03, P =0.002), −0.07 N (−0.11 to −0.03, P =0.010), and −0.48 N (−0.86 to −0.11, P =0.068), respectively. Spiral deflation with warming did not affect extubation force or sealing performance. Overall, spiral deflation effectively reduced cuff diameter by approximately 25% and lowered insertion force, while warming further enhanced ease of insertion. These approaches did not compromise sealing or extubation performance.

  • Open Access

    Factors influencing spinal anesthesia-to-delivery interval in elective cesarean sections: A retrospective analysis

    by Michiko Kinoshita, Yoko Sakai, Yoshimi Nakaji, Rikako Takahashi, Yako Matsumoto, Katsuya Tanaka

    Previous research has shown that longer intervals from spinal anesthesia (SA) to cesarean delivery are associated with lower umbilical arterial pH levels. This study aimed to identify specific risk factors related to SA-to-delivery interval in elective cesarean sections. In this retrospective analysis, 404 singleton parturients who underwent elective cesarean sections with SA after 37 weeks of gestation were assessed. Factors influencing the SA-to-delivery interval were explored. The correlation between SA-to-delivery interval and umbilical arterial pH levels was also investigated in our cohort. Factors that significantly prolonged the SA-to-delivery interval included higher body mass index (BMI; regression coefficient [RC]: 0.206, P = .003), history of previous cesarean section (RC: 1.699, P = .012), placenta previa/low-lying placenta (RC: 6.141, P < .001), and local anesthetic administration into the epidural space following SA (RC: 3.279, P < .001). The SA-to-delivery interval was slightly yet significantly inversely correlated with umbilical arterial pH ( r = −0.163, P = .001). A general linear model, adjusted for age, BMI, predominant ephedrine use, lowest systolic blood pressure between SA and delivery, diabetes mellitus, and hypertensive disorder of pregnancy have established the significant relationship between the SA-to-delivery interval and umbilical arterial pH (RC: −0.0012, P < .001). In conclusion, factors such as higher BMI, previous cesarean sections, placenta previa/low-lying placenta, and local anesthetic administration into the epidural space after SA significantly contributed to extended SA-to-delivery intervals. The SA-to-delivery interval was inversely correlated with umbilical arterial pH.

  • Earthquake Preparedness for Operating Room Staff: Lessons Learned From Experiences and the Literature

    by Yako Matsumoto, Michiko Kinoshita, Yoshinobu Tomiyama, Katsuya Tanaka

    Inform the development of effective safety measures in operating rooms. Additionally, we discuss the anesthesiologist’s role in crisis management....


  • Open Access

    Accuracy of infusion flow rates and bolus doses for portable infusion pump

    by Ryo Sekiguchi, Michiko Kinoshita, Yuki Maeda, Katsuya Tanaka

    This study aimed to investigate the flow rate accuracy and bolus doses of four portable pumps with different mechanisms. We evaluated two electronic (COOPDECH Amy PCA [Amy] and CADD-Solis) and two elastomeric balloon-type pumps (COOPDECH Balloonjector and Rakurakufuser) under the following conditions: placement with an epidural catheter, operation on a shaking table, warming to 32 °C, and at room temperature (control, 25 °C). Amy maintained consistent flow rates across all conditions. The CADD-Solis also exhibited consistent flow rates, with minor yet statistically significant changes upon epidural catheter placement (− 5.0%, P = 0.005) and motion conditions (4.2%, P = 0.015). The Balloonjector and Rakurakufuser exhibited flow rate variations over time, and temperature increases significantly increased flow rates by 24.3% (P < 0.001) and 20.3% (P < 0.001), respectively. Bolus volume accuracy for the Amy, Balloonjector, and Rakurakufuser was not significantly affected under different conditions. The CADD-Solis showed a slight decrease in bolus volume with an epidural catheter (mean difference, 0.3 mL; P = 0.003). The electronic pumps maintained consistent flow rates across various conditions, whereas elastomeric balloon pumps exhibited variable rates influenced by time and temperature, increasing the risk of medication overdose. Bolus dosing accuracy was clinically satisfactory for all pump mechanisms.


  • Open Access

    Gender representation among speakers at the Japanese Society of Anesthesiologists meetings: A retrospective analysis

    by Michiko Kinoshita, Yoko Sakai, Katsuya Tanaka

    Purpose: This study investigates the gender distribution of speakers at the Japanese Society of Anesthesiologists (JSA) annual and branch meetings of the Japanese Society of Anesthesiologists. Methods: We examined the gender of speakers in sessions at both JSA annual and branch meetings. We also verified the speakers’ Japanese medical licensure status and years of qualification. Results: We analyzed 383 sessions from JSA annual meetings between 2019 and 2024, which included 827 speaker slots. Of them, 679 (82.1%) were men and 148 (17.9%) were women. Women were significantly underrepresented in sessions with fewer speaker slots (chi-square test, p = 0.006; trend test, p < 0.001). Furthermore, sessions were frequently composed entirely of men: 73.1% of all sessions and 44.3% of panel presentations were solely male participants. Among the subspecialties, female representation was high in obstetric anesthesia (36.8%) and pediatric anesthesia (31.8%) but low in cardiovascular anesthesia (6.3%). Among 508 speakers with confirmed Japanese medical licenses, 425 (83.7%) were men, and 83 (16.3%) were women, with no significant differences in gender distribution based on the year of licensure (Fisher’s exact test, p = 0.968; trend test, p = 0.463). Additionally, we examined 104 sessions from JSA branch meetings between 2019 and 2023, comprising 176 speaker slots. Of them, 147 (83.5%) were men and 29 (16.5%) were women. There was no significant difference in gender distribution among branch meetings across different regions (p = 0.984). Conclusion: These findings underscore the need for proactive measures to promote gender diversity in Japan’s anesthesiology field.


  • Open Access

    Anesthetic management of a patient with mandibular hypoplasia, deafness, progeroid features, lipodystrophy syndrome: a case report

    by Ryo Sekiguchi, Michiko Kinoshita, Yoko Sakai, Katsuya Tanaka

    Background: Mandibular hypoplasia, deafness, progeroid features, and lipodystrophy (MDPL) syndrome is a rare autosomal dominant disorder that presents unique challenges for anesthetic management due to its multisystemic manifestations. This report outlines the anesthetic considerations for MDPL patients based on our case experience. Case presentation: A 15-year-old male with MDPL syndrome underwent testicular extraction under general anesthesia. Insertion of a peripheral venous catheter was challenging due to scleroderma-like skin. Although the facial features of MDPL syndrome suggested a difficult airway, intubation with a McGrath™ Mac video laryngoscope was successful. Despite MDPL syndrome’s association with hypertriglyceridemia due to lipodystrophy, this patient’s triglyceride levels were normal. Thiamylal and sevoflurane were used without issues such as delayed emergence from anesthesia. Conclusions: MDPL syndrome requires careful preoperative assessment and tailored anesthetic management due to potential airway challenges arising from its distinctive facial features and the possibility of altered anesthetic pharmacokinetics associated with lipodystrophy.

  • Impact of anesthesiologist experience on neuraxial anesthesia outcomes in cesarean sections

    by Yako Matsumoto, Yoko Sakai, Michiko Kinoshita, Yoshimi Nakaji, Rikako Takahashi, Katsuya Tanaka

    Despite the requirement for meticulous management of cesarean anesthesia, no study has explored the impact of novice trainee anesthesiologists in this field. This study assessed challenges in neuraxial anesthesia for cesarean sections and compared outcomes between novice and senior anesthesiologists. We retrospectively analyzed 446 cesarean sections with neuraxial anesthesia. The primary objective was to evaluate the impact of anesthesiologists' experience on the time required to administer neuraxial anesthesia and whether maternal body mass index (BMI) influenced this relationship. Secondary objectives included examining maternal hemodynamic variability, operative details, and newborn outcomes relative to the anesthesiologist's experience. Novice anesthesiologists required a significantly longer time to perform neuraxial anesthesia (24.9 [7.1] min vs. 18.2 [7.0] min, P<0.001) than their senior counterparts. A significant interaction was observed between anesthesiologist experience and maternal BMI on the time to administer neuraxial anesthesia (P=0.017), with a moderate correlation between BMI and administration time for novices (r=0.50, P<0.001) and only a slight correlation for seniors (r=0.17, P=0.001). Experience level did not significantly affect intraoperative hemodynamics, Apgar scores, or umbilical cord blood gas analyses. The effect of maternal BMI on the difficulty of performing neuraxial anesthesia in parturients can be more pronounced for novice anesthesiologists than for experienced ones. Despite requiring more time to perform neuraxial anesthesia, novice anesthesiologists do not significantly affect maternal hemodynamics or newborn distress during obstetric anesthesia, provided that they are under the supervision of experienced anesthesiologists.