Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Giorgio Cassiolas has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    In vivo efficacy of an injectable piezoelectric nanocomposite hydrogel and low-intensity pulsed ultrasound in two preclinical models of osteoarthritis

    by Matilde Tschon, Giorgia Codispoti, Paolo Cabras, Andrea Cafarelli, Diego Trucco, Lorenzo Vannozzi, Cristina Manferdini, Melania Carniato, Giorgio Cassiolas, Lucia Martini, et al.


  • Open Access

    Understanding the Structure–Function Relationship through 3D Imaging and Biomechanical Analysis: A Novel Methodological Approach Applied to Anterior Cruciate Ligaments

    by Marco Bontempi, Nicola Sancisi, Gregorio Marchiori, Michele Conconi, Matteo Berni, Giorgio Cassiolas, Gianluca Giavaresi, Annapaola Parrilli, Nicola Francesco Lopomo

    Understanding the microstructure of fibrous tissues, like ligaments, is crucial due to their nonlinear stress-strain behavior from unique fiber arrangements. This study introduces a new method to analyze the relationship between the microstructure and function of anterior cruciate ligaments (ACL). We tested the procedure on two ACL samples, one from a healthy individual and one from an osteoarthritis patient, using a custom tensioning device within a micro-CT scanner. The samples were stretched and scanned at various strain levels (namely 0%, 1%, 2%, 3%, 4%, 6%, 8%) to observe the effects of mechanical stress on the microstructure. The micro-CT images were processed to identify and map fibers, assessing their orientations and volume fractions. A probabilistic mathematical model was then proposed to relate the geometric and structural characteristics of the ACL to its mechanical properties, considering fiber orientation and thickness. Our feasibility test indicated differences in mechanical behavior, fiber orientation, and volume distribution between ligaments of different origins. These indicative results align with existing literature, validating the proposed methodology. However, further research is needed to confirm these preliminary observations. Overall, our comprehensive methodology shows promise for improving ACL diagnosis and treatment and for guiding the creation of tissue-engineered grafts that mimic the natural properties and microstructure of healthy tissue, thereby enhancing integration and performance in biomedical applications.


  • Proposal of a Multi-parametric Ergonomic Assessment Protocol Integrating Intra-operative Use of Wearable Technology to Evaluate Musculoskeletal Discomfort for Surgeon During Laryngeal Surgery

    by Emma Sala, Marco Mazzali, Emilio Paraggio, Gianluca Rossetto, Giorgio Cassiolas, Emilia Scalona, Francesco Negro, Giuseppe De Palma, Cesare Piazza, Nicola Francesco Lopomo


  • Open Access

    Knee Joint Contact Forces during High-Risk Dynamic Tasks: 90° Change of Direction and Deceleration Movements

    by Giorgio Cassiolas, Stefano Di Paolo, Gregorio Marchiori, Alberto Grassi, Francesco Della Villa, Laura Bragonzoni, Andrea Visani, Gianluca Giavaresi, Milena Fini, Stefano Zaffagnini, et al.

    Pivoting sports expose athletes to a high risk of knee injuries, mainly due to mechanical overloading of the joint which shatters overall tissue integrity. The present study explored the magnitude of tibiofemoral contact forces (TFCF) in high-risk dynamic tasks. A novel musculoskeletal model with modifiable frontal plane knee alignment was developed to estimate the total, medial, and lateral TFCF developed during vigorous activities. Thirty-one competitive soccer players performing deceleration and 90° sidestepping tasks were assessed via 3D motion analysis by using a marker-based optoelectronic system and TFCF were assessed via OpenSim software. Statistical parametric mapping was used to investigate the effect of frontal plane alignment, compartment laterality, and varus–valgus genu on TFCF. Further, in consideration of specific risk factors, sex influence was also assessed. A strong correlation (R = 0.71 ÷ 0.98, p < 0.001) was found between modification of compartmental forces and changes in frontal plane alignment. Medial and lateral TFCF were similar throughout most of the tasks with the exception of the initial phase, where the lateral compartment had to withstand to higher loadings (1.5 ÷ 3 BW higher, p = 0.010). Significant sex differences emerged in the late phase of the deceleration task. A comprehensive view of factors influencing the mediolateral distribution of TFCF would benefit knee injury prevention and rehabilitation in sport activities.


  • Automatic Classification of Working Activities for Risk Assessment in Large-Scale Retail Distribution by Using Wearable Sensors: A Preliminary Analysis

    by Giuseppe Andreoni, Giorgio Cassiolas, Carlo Emilio Standoli, Stefano Elio Lenzi, Paolo Perego, Nicola Francesco Lopomo


  • Open Access

    A Comprehensive Framework to Evaluate the Effects of Anterior Cruciate Ligament Injury and Reconstruction on Graft and Cartilage Status through the Analysis of MRI T2 Relaxation Time and Knee Laxity: A Pilot Study

    by Gregorio Marchiori, Giorgio Cassiolas, Matteo Berni, Alberto Grassi, Giacomo Dal Fabbro, Milena Fini, Giuseppe Filardo, Stefano Zaffagnini, Nicola Francesco Lopomo

    Background: Anterior cruciate ligament (ACL) tear represents a common orthopedic traumatic issue that often leads to an early development of osteoarthritis. To improve the diagnostic and prognostic techniques involved in the assessment of the joint after the trauma and during the healing process, the present work proposes a multi-parametric approach that aims to investigate the relationship between joint function and soft tissue status before and after ACL reconstruction. Methods: Thirteen consecutive patients who underwent ACL reconstruction were preliminarily enrolled in this study. Joint laxity assessment as well as magnetic resonance imaging with T2 mapping were performed in the pre-operative stage, at four and 18 months after surgery to acquire objective information to correlate knee function and soft tissue condition. Results: Correlations were found between graft and cartilage T2 signal, suggesting an interplay between these tissues within the knee joint. Moreover, graft maturation resulted in being connected to joint laxity, as underlined by the correlation between the graft T2 signal and the temporal evolution of knee function. Conclusions: This preliminary study represents a step forward in assessing the effects of ACL graft maturation on knee biomechanics, and vice versa. The presented integrated framework underlines the possibility to quantitatively assess the impact of ACL reconstruction on trauma recovery and cartilage homeostasis. Moreover, the reported findings—despite the preliminary nature of the clinical impacts—evidence the possibility of monitoring the surgery outcomes using a multi-parametric prognostic investigation tool.


  • Anisotropy and inhomogeneity of permeability and fibrous network response in the pars intermedia of the human lateral meniscus

    by Matteo Berni, Gregorio Marchiori, Giorgio Cassiolas, Alberto Grassi, Stefano Zaffagnini, Milena Fini, Nicola Francesco Lopomo, Melania Maglio


  • Open Access

    Extra-Corporeal Membrane Oxygenation Cadaver Donors: What about Tissues Used as Allografts?

    by Gregorio Marchiori, Matteo Berni, Giorgio Cassiolas, Leonardo Vivarelli, Nicola Francesco Lopomo, Milena Fini, Dante Dallari, Marco Govoni

    Several studies demonstrated the efficacy of post-mortem extracorporeal membrane oxygenation (ECMO) on donors in preserving organ function addressing organ transplantation. Nevertheless, no common and shared evidence was reached about the possibility of using ECMO donors in tissue harvesting. Therefore, this work aimed first to review the current scientific literature about ECMO donors, and then to focus on the use of ECMO tissues as allografts, mainly addressing musculoskeletal tissues, which are of the most interest for reconstruction. A search was conducted on the current scientific literature, focusing on the keywords “ECMO” and “Donor”. Several online databases were used, including PubMed, Scopus, and Web of Science. From the preliminary search, 478 articles were obtained, out of which 173 specifically reported the use of ECMO for donation and transplantation purposes. Literature reported extensive analyses of ECMO organs—overall from the abdomen—both in pre- and post-transplantation studies. On the other hand, ECMO tissues were explanted only in a very limited number of cases; moreover, no information was referred about their status and use. A revision of the current scientific literature highlighted the lack of information concerning ECMO tissues and the necessity to perform preclinical, ex vivo studies to compare allografts from ECMO donors, with respect to standard donors, and, thus, to verify whether they can be harvested and implanted safely and with efficacy.


  • Open Access

    Impact of Surface Functionalization by Nanostructured Silver Thin Films on Thermoplastic Central Venous Catheters: Mechanical, Microscopical and Thermal Analyses

    by Gregorio Marchiori, Alessandro Gambardella, Matteo Berni, Devis Bellucci, Giorgio Cassiolas, Valeria Cannillo

    In this work, an interdisciplinary approach was employed to investigate the impact on thermoplastic catheters from the deposition of a thin (180 nm), metallic silver film by a pulsed ablation technique. Our characterization firstly involved tensile and bending tests, each one accompanied by finite element modeling aiming to elucidate the contributions resulting from bulk and coating to the device’s mechanical behavior. The morphological assessment of the surface before and after the deposition was performed by atomic force microscopy, specifically implemented to visualize the nanostructured character of the film surface and the extent to which the polymer was modified by the deposition process, focusing on coating delamination due to tensile stress. Finally, thermogravimetric–differential thermal analysis was carried out to evaluate whether silver deposition has affected the physiochemical structure of the polymer matrix. Our results establish that the deposition does not significantly alter the physical and chemical properties of the device. The presented characterization sets a useful precedent for elucidating how structural properties of polymeric materials may change after coating by electronic ablation techniques, highlighting the importance of employing a comprehensive approach for clarifying the effects of additive manufacturing on medical devices.