Bashair Alhummiany
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bashair Alhummiany has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
Kanishka Sharma
3 shared publications- Abdulkareem Algahtani
Department of Diagnostic Radiology, College of Applied Medical Sciences, Taibah University, Madinah 42353, Saudi Arabia
2 shared publications - Awadia Gareeballah
Department of Diagnostic Radiology, College of Applied Medical Sciences, Taibah University, Madinah 42353, Saudi Arabia
2 shared publications David Shelley
2 shared publications- Hanan Mohammed Alzahrani
Department of Diagnostic Radiology, College of Applied Medical Sciences, Taibah University, Madinah 42353, Saudi Arabia
2 shared publications Kywe Kywe Soe
2 shared publications
Latest Publications
- Open Access
Associations of Pretreatment Hemoglobin, Body Mass Index, and Leukocyte Count with Acute and Late Toxicity During and After Radiotherapy for Rectal Cancer
Background/Objectives: Radiotherapy is an important component of rectal cancer treatment, but treatment-related toxicity varies considerably between patients, suggesting that patient-related factors may influence susceptibility. Pretreatment hemoglobin, leukocyte count, and body mass index (BMI) are routinely available measures, yet their associations with acute and late toxicity during and after radiotherapy remain unclear. This study evaluated these associations in patients with rectal cancer. Methods: A retrospective analysis included 67 patients with histologically confirmed rectal cancer who underwent radiotherapy. Acute toxicity occurred during radiotherapy or within 3 months after treatment completion, and late toxicity occurred thereafter. Toxicity was graded using the Common Terminology Criteria for Adverse Events (CTCAE) and dichotomized as Grades 0–1 or Grade ≥ 2. Pretreatment hemoglobin, total leukocyte count, and BMI were analyzed as continuous variables. Logistic regression examined associations with acute and late toxicity, with sequential adjustment for age, sex, and radiotherapy course. Results: Grade ≥ 2 acute toxicity occurred in 17 patients (25.4%), and Grade ≥ 2 late toxicity in 27 (40.3%). Higher pretreatment leukocyte count was associated with greater odds of acute toxicity in the fully adjusted model (OR 1.70, 95% CI 1.13–2.58; p = 0.012). Higher pretreatment hemoglobin was associated with lower odds of late toxicity in the fully adjusted model (OR 0.57, 95% CI 0.40–0.81; p = 0.002). No clear association was observed between BMI and either acute or late toxicity. Conclusions: Pretreatment leukocyte count was associated with acute toxicity, while pretreatment hemoglobin was associated with late toxicity. These inexpensive, routinely available measures may represent candidate markers of toxicity, although their clinical utility requires validation in larger, independent studies.
Open AccessAssociations of Pretreatment Hemoglobin, Body Mass Index, and Leukocyte Count with Acute and Late Toxicity During and After Radiotherapy for Rectal Cancer
Background/Objectives: Radiotherapy is an important component of rectal cancer treatment, but treatment-related toxicity varies considerably between patients, suggesting that patient-related factors may influence susceptibility. Pretreatment hemoglobin, leukocyte count, and body mass index (BMI) are routinely available measures, yet their associations with acute and late toxicity during and after radiotherapy remain unclear. This study evaluated these associations in patients with rectal cancer. Methods: A retrospective analysis included 67 patients with histologically confirmed rectal cancer who underwent radiotherapy. Acute toxicity occurred during radiotherapy or within 3 months after treatment completion, and late toxicity occurred thereafter. Toxicity was graded using the Common Terminology Criteria for Adverse Events (CTCAE) and dichotomized as Grades 0–1 or Grade ≥ 2. Pretreatment hemoglobin, total leukocyte count, and BMI were analyzed as continuous variables. Logistic regression examined associations with acute and late toxicity, with sequential adjustment for age, sex, and radiotherapy course. Results: Grade ≥ 2 acute toxicity occurred in 17 patients (25.4%), and Grade ≥ 2 late toxicity in 27 (40.3%). Higher pretreatment leukocyte count was associated with greater odds of acute toxicity in the fully adjusted model (OR 1.70, 95% CI 1.13–2.58; p = 0.012). Higher pretreatment hemoglobin was associated with lower odds of late toxicity in the fully adjusted model (OR 0.57, 95% CI 0.40–0.81; p = 0.002). No clear association was observed between BMI and either acute or late toxicity. Conclusions: Pretreatment leukocyte count was associated with acute toxicity, while pretreatment hemoglobin was associated with late toxicity. These inexpensive, routinely available measures may represent candidate markers of toxicity, although their clinical utility requires validation in larger, independent studies.
- Open Access
- 26 August 2026
- Published by MDPI AG in Healthcare
- Vol. 14 (17) , 2718
Work-Related Musculoskeletal Disorders Among Radiology and Ultrasound Technologists During Ramadan in Madinah, Saudi Arabia: A Cross-Sectional Study
Background: Radiology and ultrasound technologists are exposed to sustained static postures, repetitive movements, equipment handling, and patient-positioning tasks that increase the risk of work-related musculoskeletal disorders (WRMSDs). During Ramadan, increased healthcare demand associated with Umrah may further increase occupational workload in Madinah. Objective: To estimate the 7-day prevalence of WRMSDs and identify occupational factors associated with pain intensity among radiology and ultrasound technologists working during Ramadan in Madinah. Methods: A cross-sectional online survey was conducted among 237 radiology and ultrasound technologists working in Madinah during Ramadan 1447/2026. Participants were recruited using online convenience and snowball sampling through professional networks and social-media platforms. The survey included the Nordic Musculoskeletal Questionnaire (NMQ), a 0–10 Numeric Pain Rating Scale (NPRS), and demographic and occupational variables. Bivariate analyses and multivariable linear regression with robust standard errors were used to examine factors associated with pain intensity. Results: Overall, 89.5% of participants reported WRMSDs during the preceding 7 days. The lower back (56.5%) and neck (40.5%) were the most affected regions. Mean pain intensity was 5.55 ± 2.28. Higher pain intensity was associated, after adjustment for the variables included in the model, with older age, working as an ultrasound technologist, managing 11–20 or more than 30 patients per shift, and frequent night-shifts, with the strongest association observed among participants working at least three-night-shifts per week (B = 3.27, 95% CI 2.43–4.10). BMI, sex, years of experience and shift duration were not independently associated with pain intensity after adjustment. Conclusions: WRMSDs were highly prevalent among radiology and ultrasound technologists working during Ramadan in Madinah. Night-shift frequency and very high patient workload showed the largest occupational associations with pain intensity. These findings identify workload distribution and night-shift scheduling as potential areas for occupational health evaluation during periods of increased healthcare demand. Because of the cross-sectional design, the findings should be interpreted as associations rather than causal effects.
- 26 August 2026
- Published by MDPI AG in Healthcare
- Vol. 14 (17) , 2718
Open AccessWork-Related Musculoskeletal Disorders Among Radiology and Ultrasound Technologists During Ramadan in Madinah, Saudi Arabia: A Cross-Sectional Study
Background: Radiology and ultrasound technologists are exposed to sustained static postures, repetitive movements, equipment handling, and patient-positioning tasks that increase the risk of work-related musculoskeletal disorders (WRMSDs). During Ramadan, increased healthcare demand associated with Umrah may further increase occupational workload in Madinah. Objective: To estimate the 7-day prevalence of WRMSDs and identify occupational factors associated with pain intensity among radiology and ultrasound technologists working during Ramadan in Madinah. Methods: A cross-sectional online survey was conducted among 237 radiology and ultrasound technologists working in Madinah during Ramadan 1447/2026. Participants were recruited using online convenience and snowball sampling through professional networks and social-media platforms. The survey included the Nordic Musculoskeletal Questionnaire (NMQ), a 0–10 Numeric Pain Rating Scale (NPRS), and demographic and occupational variables. Bivariate analyses and multivariable linear regression with robust standard errors were used to examine factors associated with pain intensity. Results: Overall, 89.5% of participants reported WRMSDs during the preceding 7 days. The lower back (56.5%) and neck (40.5%) were the most affected regions. Mean pain intensity was 5.55 ± 2.28. Higher pain intensity was associated, after adjustment for the variables included in the model, with older age, working as an ultrasound technologist, managing 11–20 or more than 30 patients per shift, and frequent night-shifts, with the strongest association observed among participants working at least three-night-shifts per week (B = 3.27, 95% CI 2.43–4.10). BMI, sex, years of experience and shift duration were not independently associated with pain intensity after adjustment. Conclusions: WRMSDs were highly prevalent among radiology and ultrasound technologists working during Ramadan in Madinah. Night-shift frequency and very high patient workload showed the largest occupational associations with pain intensity. These findings identify workload distribution and night-shift scheduling as potential areas for occupational health evaluation during periods of increased healthcare demand. Because of the cross-sectional design, the findings should be interpreted as associations rather than causal effects.
- Open Access
- 15 August 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (16) , 2584
Perianal Fistulae Medical Imaging Maps: A Pictorial Diagnostic Review
Perianal fistula, or anal fistula, is an abnormal granulomatous tract connecting the anal canal or rectum to the surrounding skin. It causes perianal pain and fistulous discharge, negatively impacting patients’ quality of life. The mechanism underlying fistula formation remains incompletely understood. Medical imaging is essential for accurate preoperative assessment of the shape, number and branching of fistulous tracts, identification of internal openings and Parks’ classification. This pictorial review provides an image-based overview of the key medical imaging concepts essential for the diagnosis of perianal fistulae and summarises the roles, advantages and limitations of the available imaging modalities for evaluating perianal fistulae. The current evidence on X-ray fistulography, computed tomography (CT) fistulography, transcutaneous ultrasonography (TCUS), endoanal ultrasonography (EAUS) and pelvic magnetic resonance imaging (MRI) was reviewed, emphasising on their diagnostic performance and clinical applications. Conventional X-ray fistulography has progressively been abandoned because it is invasive, is uncomfortable for patients, provides poor soft tissue contrast and inadequately visualises anal sphincters, complex fistulous tracts, secondary branches and abscesses. CT fistulography is useful for evaluating perianal abscesses and fistula when MRI and EAUS are unavailable. TCUS is widely available, non-invasive and radiation-free but is operator-dependent and has limited ability to evaluate high perianal fistulae. EAUS accurately evaluates fistulous tracts, can be performed at the bedside or intraoperatively and is reliable when MRI is contraindicated. However, EAUS is operator-dependent, is contraindicated in patients with severe anal stenosis or acute anal pain, and has a small field of view. Pelvic MRI is the gold standard, providing excellent visualisation of anal canal anatomy, superior soft tissue contrast, accurate mapping of fistulous tracts, localisation of internal openings, assessment of the involvement of anal sphincters and detection of secondary tracts, abscesses and associated complications. Consequently, MRI is a preferred imaging modality, which can guide treatment decisions and monitoring of treatment response.
- 15 August 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (16) , 2584
Open AccessPerianal Fistulae Medical Imaging Maps: A Pictorial Diagnostic Review
Perianal fistula, or anal fistula, is an abnormal granulomatous tract connecting the anal canal or rectum to the surrounding skin. It causes perianal pain and fistulous discharge, negatively impacting patients’ quality of life. The mechanism underlying fistula formation remains incompletely understood. Medical imaging is essential for accurate preoperative assessment of the shape, number and branching of fistulous tracts, identification of internal openings and Parks’ classification. This pictorial review provides an image-based overview of the key medical imaging concepts essential for the diagnosis of perianal fistulae and summarises the roles, advantages and limitations of the available imaging modalities for evaluating perianal fistulae. The current evidence on X-ray fistulography, computed tomography (CT) fistulography, transcutaneous ultrasonography (TCUS), endoanal ultrasonography (EAUS) and pelvic magnetic resonance imaging (MRI) was reviewed, emphasising on their diagnostic performance and clinical applications. Conventional X-ray fistulography has progressively been abandoned because it is invasive, is uncomfortable for patients, provides poor soft tissue contrast and inadequately visualises anal sphincters, complex fistulous tracts, secondary branches and abscesses. CT fistulography is useful for evaluating perianal abscesses and fistula when MRI and EAUS are unavailable. TCUS is widely available, non-invasive and radiation-free but is operator-dependent and has limited ability to evaluate high perianal fistulae. EAUS accurately evaluates fistulous tracts, can be performed at the bedside or intraoperatively and is reliable when MRI is contraindicated. However, EAUS is operator-dependent, is contraindicated in patients with severe anal stenosis or acute anal pain, and has a small field of view. Pelvic MRI is the gold standard, providing excellent visualisation of anal canal anatomy, superior soft tissue contrast, accurate mapping of fistulous tracts, localisation of internal openings, assessment of the involvement of anal sphincters and detection of secondary tracts, abscesses and associated complications. Consequently, MRI is a preferred imaging modality, which can guide treatment decisions and monitoring of treatment response.
- Open Access
- 8 October 2025
- Published by MDPI AG in Healthcare
- Vol. 13 (19) , 2538
An Exploratory Analysis of Public Perspectives and Attitudes Towards Radiation in Saudi Arabia
Aim: Radiation exposure is a growing public health concern; however, public understanding of its sources, risks, and protective measures remains limited. This study examined familiarity, misconceptions, and attitudes towards both ionising and nonionising radiation among residents of Saudi Arabia, an area that has received limited attention in the literature. Methods: A cross-sectional survey was conducted among 888 Saudi residents aged 18 years and above by using a validated online questionnaire. The instrument comprised demographic items, 13 statements assessing radiation familiarity (including knowledge of sources and safety), and 21 items assessing attitudes (including safety practices and willingness to receive further education), all rated on a five-point Likert scale. Descriptive statistics and nonparametric inferential analyses were performed using SPSS v27. Results: Participants had a moderate mean familiarity score (3.34 ± 1.16), whereas attitude scores were high (3.56 ± 1.14). Demographic variables, including age, sex, region, and previous training, significantly affected familiarity and attitudes. A medical background and previous radiation education were associated with a higher familiarity level. Nonetheless, most participants expressed a strong interest in acquiring additional knowledge. Conclusion: Moderate familiarity with radiation and strong attitudes towards protection among the Saudi public highlight opportunities to strengthen practical safety knowledge. These findings indicate the need for targeted, accessible educational initiatives, particularly through digital platforms, to enhance radiation literacy and support the objectives of Saudi Vision 2030.
- 8 October 2025
- Published by MDPI AG in Healthcare
- Vol. 13 (19) , 2538
Open AccessAn Exploratory Analysis of Public Perspectives and Attitudes Towards Radiation in Saudi Arabia
Aim: Radiation exposure is a growing public health concern; however, public understanding of its sources, risks, and protective measures remains limited. This study examined familiarity, misconceptions, and attitudes towards both ionising and nonionising radiation among residents of Saudi Arabia, an area that has received limited attention in the literature. Methods: A cross-sectional survey was conducted among 888 Saudi residents aged 18 years and above by using a validated online questionnaire. The instrument comprised demographic items, 13 statements assessing radiation familiarity (including knowledge of sources and safety), and 21 items assessing attitudes (including safety practices and willingness to receive further education), all rated on a five-point Likert scale. Descriptive statistics and nonparametric inferential analyses were performed using SPSS v27. Results: Participants had a moderate mean familiarity score (3.34 ± 1.16), whereas attitude scores were high (3.56 ± 1.14). Demographic variables, including age, sex, region, and previous training, significantly affected familiarity and attitudes. A medical background and previous radiation education were associated with a higher familiarity level. Nonetheless, most participants expressed a strong interest in acquiring additional knowledge. Conclusion: Moderate familiarity with radiation and strong attitudes towards protection among the Saudi public highlight opportunities to strengthen practical safety knowledge. These findings indicate the need for targeted, accessible educational initiatives, particularly through digital platforms, to enhance radiation literacy and support the objectives of Saudi Vision 2030.
- 26 November 2024
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
3D Kidney Segmentation in MRI using Transformers
Motivation: Convolutional Neural Networks (CNNs) have long been the go-to deep-learning architecture for medical image segmentation, but in recent years transformer-based architectures adapted from large language models are setting a new standard. Goal(s): The aim of this study was to test if transformers are suitable for 3D kidney segmentation on high-resolution MRI. Approach: A transformer-based deep-learning architecture (UNETR) was trained and tested against a supervised method on 82 patient datasets from the iBEAt study on diabetic kidney disease. Results: UNETR provides fast segmentation with comparable results to the supervised method, but additional refinement is needed to reduce the limits of agreement. Impact: Novel transformer-based architectures for medical image segmentation may be useful for fast 3D segmentation of individual kidneys.
- 26 November 2024
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
3D Kidney Segmentation in MRI using Transformers
Motivation: Convolutional Neural Networks (CNNs) have long been the go-to deep-learning architecture for medical image segmentation, but in recent years transformer-based architectures adapted from large language models are setting a new standard. Goal(s): The aim of this study was to test if transformers are suitable for 3D kidney segmentation on high-resolution MRI. Approach: A transformer-based deep-learning architecture (UNETR) was trained and tested against a supervised method on 82 patient datasets from the iBEAt study on diabetic kidney disease. Results: UNETR provides fast segmentation with comparable results to the supervised method, but additional refinement is needed to reduce the limits of agreement. Impact: Novel transformer-based architectures for medical image segmentation may be useful for fast 3D segmentation of individual kidneys.
- Open Access
- 16 November 2023
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 37 (4) , 565-582
Physiological confounders of renal blood flow measurement
Objectives: Renal blood flow (RBF) is controlled by a number of physiological factors that can contribute to the variability of its measurement. The purpose of this review is to assess the changes in RBF in response to a wide range of physiological confounders and derive practical recommendations on patient preparation and interpretation of RBF measurements with MRI. Methods: A comprehensive search was conducted to include articles reporting on physiological variations of renal perfusion, blood and/or plasma flow in healthy humans. Results: A total of 24 potential confounders were identified from the literature search and categorized into non-modifiable and modifiable factors. The non-modifiable factors include variables related to the demographics of a population (e.g. age, sex, and race) which cannot be manipulated but should be considered when interpreting RBF values between subjects. The modifiable factors include different activities (e.g. food/fluid intake, exercise training and medication use) that can be standardized in the study design. For each of the modifiable factors, evidence-based recommendations are provided to control for them in an RBF-measurement. Conclusion: Future studies aiming to measure RBF are encouraged to follow a rigorous study design, that takes into account these recommendations for controlling the factors that can influence RBF results.
- 16 November 2023
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 37 (4) , 565-582
Open AccessPhysiological confounders of renal blood flow measurement
Objectives: Renal blood flow (RBF) is controlled by a number of physiological factors that can contribute to the variability of its measurement. The purpose of this review is to assess the changes in RBF in response to a wide range of physiological confounders and derive practical recommendations on patient preparation and interpretation of RBF measurements with MRI. Methods: A comprehensive search was conducted to include articles reporting on physiological variations of renal perfusion, blood and/or plasma flow in healthy humans. Results: A total of 24 potential confounders were identified from the literature search and categorized into non-modifiable and modifiable factors. The non-modifiable factors include variables related to the demographics of a population (e.g. age, sex, and race) which cannot be manipulated but should be considered when interpreting RBF values between subjects. The modifiable factors include different activities (e.g. food/fluid intake, exercise training and medication use) that can be standardized in the study design. For each of the modifiable factors, evidence-based recommendations are provided to control for them in an RBF-measurement. Conclusion: Future studies aiming to measure RBF are encouraged to follow a rigorous study design, that takes into account these recommendations for controlling the factors that can influence RBF results.
- 16 August 2021
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 55 (4) , 1241-1250
Bias and Precision in Magnetic Resonance Imaging‐Based Estimates of Renal Blood Flow: Assessment by Triangulation
Background: Renal blood flow (RBF) can be measured with dynamic contrast enhanced‐MRI (DCE‐MRI) and arterial spin labeling (ASL). Unfortunately, individual estimates from both methods vary and reference‐standard methods are not available. A potential solution is to include a third, arbitrating MRI method in the comparison.Purpose: To compare RBF estimates between ASL, DCE, and phase contrast (PC)‐MRI.Study Type: Prospective.Population: Twenty‐five patients with type‐2 diabetes (36% female) and five healthy volunteers (HV, 80% female).Field Strength/Sequences: A 3 T; gradient‐echo 2D‐DCE, pseudo‐continuous ASL (pCASL) and cine 2D‐PC.Assessment: ASL, DCE, and PC were acquired once in all patients. ASL and PC were acquired four times in each HV. RBF was estimated and split‐RBF was derived as (right kidney RBF)/total RBF. Repeatability error (RE) was calculated for each HV, RE = 1.96 × SD, where SD is the standard deviation of repeat scans.Statistical Tests: Paired t‐tests and one‐way analysis of variance (ANOVA) were used for statistical analysis. The 95% confidence interval (CI) for difference between ASL/PC and DCE/PC was assessed using two‐sample F‐test for variances. Statistical significance level was P < 0.05. Influential outliers were assessed with Cook's distance (Di > 1) and results with outliers removed were presented.Results: In patients, the mean RBF (mL/min/1.73m2) was 618 ± 62 (PC), 526 ± 91 (ASL), and 569 ± 110 (DCE). Differences between measurements were not significant (P = 0.28). Intrasubject agreement was poor for RBF with limits‐of‐agreement (mL/min/1.73m2) [−687, 772] DCE‐ASL, [−482, 580] PC‐DCE, and [−277, 460] PC‐ASL. The difference PC‐ASL was significantly smaller than PC‐DCE, but this was driven by a single‐DCE outlier (P = 0.31, after removing outlier). The difference in split‐RBF was comparatively small. In HVs, mean RE (±95% CI; mL/min/1.73 m2) was significantly smaller for PC (79 ± 41) than for ASL (241 ± 85).Conclusions: ASL, DCE, and PC RBF show poor agreement in individual subjects but agree well on average. Triangulation with PC suggests that the accuracy of ASL and DCE is comparable.Evidence Level: 2Technical Efficacy: Stage 2
- 16 August 2021
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 55 (4) , 1241-1250
Bias and Precision in Magnetic Resonance Imaging‐Based Estimates of Renal Blood Flow: Assessment by Triangulation
Background: Renal blood flow (RBF) can be measured with dynamic contrast enhanced‐MRI (DCE‐MRI) and arterial spin labeling (ASL). Unfortunately, individual estimates from both methods vary and reference‐standard methods are not available. A potential solution is to include a third, arbitrating MRI method in the comparison.Purpose: To compare RBF estimates between ASL, DCE, and phase contrast (PC)‐MRI.Study Type: Prospective.Population: Twenty‐five patients with type‐2 diabetes (36% female) and five healthy volunteers (HV, 80% female).Field Strength/Sequences: A 3 T; gradient‐echo 2D‐DCE, pseudo‐continuous ASL (pCASL) and cine 2D‐PC.Assessment: ASL, DCE, and PC were acquired once in all patients. ASL and PC were acquired four times in each HV. RBF was estimated and split‐RBF was derived as (right kidney RBF)/total RBF. Repeatability error (RE) was calculated for each HV, RE = 1.96 × SD, where SD is the standard deviation of repeat scans.Statistical Tests: Paired t‐tests and one‐way analysis of variance (ANOVA) were used for statistical analysis. The 95% confidence interval (CI) for difference between ASL/PC and DCE/PC was assessed using two‐sample F‐test for variances. Statistical significance level was P < 0.05. Influential outliers were assessed with Cook's distance (Di > 1) and results with outliers removed were presented.Results: In patients, the mean RBF (mL/min/1.73m2) was 618 ± 62 (PC), 526 ± 91 (ASL), and 569 ± 110 (DCE). Differences between measurements were not significant (P = 0.28). Intrasubject agreement was poor for RBF with limits‐of‐agreement (mL/min/1.73m2) [−687, 772] DCE‐ASL, [−482, 580] PC‐DCE, and [−277, 460] PC‐ASL. The difference PC‐ASL was significantly smaller than PC‐DCE, but this was driven by a single‐DCE outlier (P = 0.31, after removing outlier). The difference in split‐RBF was comparatively small. In HVs, mean RE (±95% CI; mL/min/1.73 m2) was significantly smaller for PC (79 ± 41) than for ASL (241 ± 85).Conclusions: ASL, DCE, and PC RBF show poor agreement in individual subjects but agree well on average. Triangulation with PC suggests that the accuracy of ASL and DCE is comparable.Evidence Level: 2Technical Efficacy: Stage 2