Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mu Shen has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Epileptic Tissue Localization through Skewness-Based Functional Connectivity in the High-Frequency Band of Intracranial EEG

    by Mu Shen, Lin Zhang, Yi Gong, Lei Li, Xianzeng Liu

    Functional connectivity analysis of intracranial electroencephalography (iEEG) plays an important role in understanding the mechanism of epilepsy and seizure dynamics. However, existing connectivity analysis is only suitable for low-frequency bands below 80 Hz. High-frequency oscillations (HFOs) and high-frequency activity (HFA) in the high-frequency band (80–500 Hz) are thought to be specific biomarkers in epileptic tissue localization. However, the transience in duration and variability of occurrence time and amplitudes of these events pose a challenge for conducting effective connectivity analysis. To deal with this problem, we proposed skewness-based functional connectivity (SFC) in the high-frequency band and explored its utility in epileptic tissue localization and surgical outcome evaluation. SFC comprises three main steps. The first step is the quantitative measurement of amplitude distribution asymmetry between HFOs/HFA and baseline activity. The second step is functional network construction on the basis of rank correlation of asymmetry across time. The third step is connectivity strength extraction from the functional network. Experiments were conducted in two separate datasets which consist of iEEG recordings from 59 patients with drug-resistant epilepsy. Significant difference (p<0.001) in connectivity strength was found between epileptic and non-epileptic tissue. Results were quantified via the receiver operating characteristic curve and the area under the curve (AUC). Compared with low-frequency bands, SFC demonstrated superior performance. With respect to pooled and individual epileptic tissue localization for seizure-free patients, AUCs were 0.66 (95% confidence interval (CI): 0.63–0.69) and (0.63 95% CI 0.56–0.71), respectively. For surgical outcome classification, the AUC was 0.75 (95% CI 0.59–0.85). Therefore, SFC can act as a promising assessment tool in characterizing the epileptic network and potentially provide better treatment options for patients with drug-resistant epilepsy.


  • Open Access

    Automatic Epileptic Tissue Localization Through Spatial Pattern Clustering of High Frequency Activity

    by Mu Shen, Hongchuan Niu, Qing Xia, Bing Zou, Yubo Zheng, Yuanli Zhao, Lei Li, Xianzeng Liu, Lin Zhang

    High-frequency activity (HFA) in intracranial electroencephalography recordings are diagnostic biomarkers for refractory epilepsy. Clinical utilities based on HFA have been extensively examined. HFA often exhibits different spatial patterns corresponding to specific states of neural activation, which will potentially improve epileptic tissue localization. However, research on quantitative measurement and separation of such patterns is still lacking. In this paper, spatial pattern clustering of HFA (SPC-HFA) is developed. The process is composed of three steps: (1) feature extraction: skewness which quantifies the intensity of HFA is extracted; (2) clustering: k-means clustering is applied to separate column vectors within the feature matrix into intrinsic spatial patterns; (3) localization: the determination of epileptic tissue is performed based on the cluster centroid with HFA expanding to the largest spatial extent. Experiments were conducted on a public iEEG dataset with 20 patients. Compared with existing localization methods, SPC-HFA demonstrates improvement (Cohen’s d > 0.2) and ranks top in 10 out of 20 patients in terms of the area under the curve. In addition, after extending SPC-HFA to high-frequency oscillation detection algorithms, corresponding localization results also improve with effect size Cohen’s d ≥ 0.48. Therefore, SPC-HFA can be utilized to guide clinical and surgical treatment of refractory epilepsy.


  • BEATS: An Open-Source, High-Precision, Multi-Channel EEG Acquisition Tool System

    by Bing Zou, Yubo Zheng, Mu Shen, Yingying Luo, Lei Li, Lin Zhang

    Stable and accurate electroencephalogram (EEG) signal acquisition is fundamental in non-invasive brain-computer interface (BCI) technology. Commonly used EEG acquisition systems' hardware and software are usually closed-source. Its inability to flexible expansion and secondary development is a major obstacle to real-time BCI research. This paper presents the Beijing University of Posts and Telecommunications EEG Acquisition Tool System named BEATS. It implements a comprehensive system from hardware to software, composed of the analog front end, microprocessor, and software platform. BEATS is capable of collecting 32-channel EEG signals at a guaranteed sampling rate of 4 kHz with wireless transmission. Compared to state-of-the-art systems used in many EEG fields, it displays a better sampling rate. Using techniques including direct memory access, first in first out, and timer, the precision and stability of the acquisition are ensured at the microsecond level. An evaluation is conducted during 24 hours of continuous acquisitions. There are no packet losses and the average maximum delay is only 0.07 s/h. Moreover, as an open-source system, BEATS provides detailed design files, and adopts a plug-in structure and easy-to-access materials, which makes it can be quickly reproduced. Schematics, source code, and other materials of BEATS are available at https://github.com/buptantEEG/BEATS .