Chantal Kang
Chantal Kang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Alain Cohen-Solal
Department of Cardiology, Universite de Paris, UMRS 942, 75010 Paris, France
1 shared publication - Andreas Goetzenich
Faculty of Medicine, Department of Cardiac Surgery, University Hospital Aachen, RWTH Aachen University, 52074 Aachen, Germany
1 shared publication - Christoph Nix
Abiomed Europe GmbH, 52074 Aachen, Germany
1 shared publication - Guillaume Lebreton
Service de Chirurgie Cardiaque et Thoracique, Institut de Cardiologie, AP-HP, Sorbonne Université, Hôpital Pitié-Salpêtrière, Paris, France
1 shared publication - Michel Bonneau
XP-MED, 78100 Saint Germain en Laye, France
1 shared publication - Pascal Leprince
Sorbonne University, La Pitié Sâlpétrière Hospital
1 shared publication
Latest Publications
- Open Access
- 17 August 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (16) , 3623
Severe Myocardial Dysfunction after Non-Ischemic Cardiac Arrest: Effectiveness of Percutaneous Assist Devices
Introduction: Despite the improvements in standardized cardiopulmonary resuscitation, survival remains low, mainly due to initial myocardial dysfunction and hemodynamic instability. Our goal was to compare the efficacy of two left ventricular assist devices on resuscitation and hemodynamic supply in a porcine model of ventricular fibrillation (VF) cardiac arrest. Methods: Seventeen anaesthetized pigs had 12 min of untreated VF followed by 6 min of chest compression and boluses of epinephrine. Next, a first defibrillation was attempted and pigs were randomized to any of the three groups: control (n = 5), implantation of an percutaneous left ventricular assist device (Impella, n = 5) or extracorporeal membrane oxygenation (ECMO, n = 7). Hemodynamic and myocardial functions were evaluated invasively at baseline, at return of spontaneous circulation (ROSC), after 10–30–60–120–240 min post-resuscitation. The primary endpoint was the rate of ROSC. Results: Only one of 5 pigs in the control group, 5 of 5 pigs in the Impella group, and 5 of 7 pigs in the ECMO group had ROSC (p < 0.05). Left ventricular ejection fraction at 240 min post-resuscitation was 37.5 ± 6.2% in the ECMO group vs. 23 ± 3% in the Impella group (p = 0.06). No significant difference in hemodynamic parameters was observed between the two ventricular assist devices. Conclusion: Early mechanical circulatory support appeared to improve resuscitation rates in a shockable rhythm model of cardiac arrest. This approach appears promising and should be further evaluated.
- 17 August 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (16) , 3623
Open AccessSevere Myocardial Dysfunction after Non-Ischemic Cardiac Arrest: Effectiveness of Percutaneous Assist Devices
Introduction: Despite the improvements in standardized cardiopulmonary resuscitation, survival remains low, mainly due to initial myocardial dysfunction and hemodynamic instability. Our goal was to compare the efficacy of two left ventricular assist devices on resuscitation and hemodynamic supply in a porcine model of ventricular fibrillation (VF) cardiac arrest. Methods: Seventeen anaesthetized pigs had 12 min of untreated VF followed by 6 min of chest compression and boluses of epinephrine. Next, a first defibrillation was attempted and pigs were randomized to any of the three groups: control (n = 5), implantation of an percutaneous left ventricular assist device (Impella, n = 5) or extracorporeal membrane oxygenation (ECMO, n = 7). Hemodynamic and myocardial functions were evaluated invasively at baseline, at return of spontaneous circulation (ROSC), after 10–30–60–120–240 min post-resuscitation. The primary endpoint was the rate of ROSC. Results: Only one of 5 pigs in the control group, 5 of 5 pigs in the Impella group, and 5 of 7 pigs in the ECMO group had ROSC (p < 0.05). Left ventricular ejection fraction at 240 min post-resuscitation was 37.5 ± 6.2% in the ECMO group vs. 23 ± 3% in the Impella group (p = 0.06). No significant difference in hemodynamic parameters was observed between the two ventricular assist devices. Conclusion: Early mechanical circulatory support appeared to improve resuscitation rates in a shockable rhythm model of cardiac arrest. This approach appears promising and should be further evaluated.