David A. Cornwell
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
David A. Cornwell has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Nancy E. McTigue
Cornwell Engineering Group Newport News Virginia USA
2 shared publicationsBenjamin Swaringen
Cornwell Research Group Newport News Virginia USA
1 shared publicationDamon K. Roth
1 shared publication- Douglas Crawford-Brown
University of North Carolina Chapel Hill North Carolina USA
1 shared publication Emory Hayden‐Kaplan
Department of Environmental Engineering Sciences, Engineering School of Sustainable Infrastructures and Environment University of Florida Gainesville Florida USA
1 shared publicationGeorge Kamenov
Department of Geological Sciences University of Florida Gainesville Florida USA
1 shared publication
Latest Publications
- 1 March 2025
- Published by Wiley in AWWA Water Science
- Vol. 7 (2)
Lead Solubility in Drinking Water: A Comparison of Experimental Lead Solubility and Geochemical Modeling Predictions
Geochemical solubility modeling is a cost‐effective method to estimate equilibrium lead (Pb) concentrations in drinking water under specific environmental conditions. Laboratory Pb‐solubility studies (sometimes called coupon studies) are also economical and can generate comparative Pb solubility data for different water qualities. Both methods are widely used by utilities in screening corrosion control treatment, and both methods are assumed to provide insights on CCT for Pb without the influence of years of built‐up scale. No research has compared the two methods to see if they give similar results for the same water. While these techniques have limitations and do not always represent Pb levels in service lines and premise plumbing, they are valuable for predicting Pb solubility trends under controlled conditions. In this study, Pb coupons immersed in chemically diverse waters provided experimental data on Pb solubility, which was then compared to predictions from two widely used geochemical models, MINEQL+ and LEADSOL. In tests without orthophosphate (PO43−), experimental Pb concentrations increased as pH decreased, consistent with model predictions. Between pH 7.5 and 8.5, Pb levels slightly declined as predicted by the model but were less dependent on dissolved inorganic carbon (DIC) than model predictions. However, at pH 8.5–10, Pb concentrations remained constant experimentally, whereas the model predicted significant reductions in Pb. Neither MINEQL+ nor LEADSOL models and experimental data were statistically the same using the built‐in constants. Adjusting Log Ksp for hydrocerussite allowed the data and models to be statistically the same. In waters with PO43−, high DIC (50 mg/L as C) experimental results matched model predictions. At low DIC (3 mg/L as C), Pb concentrations varied less than modeled, and higher PO43− doses were needed to reduce Pb levels compared to low‐DIC waters. Overall, geochemical modeling and Pb solubility studies provide critical insights into Pb control strategies, and either or both methods can help screen the impact of possible water quality changes on Pb levels. Solubility testing is preferred, as site‐specific solubility constants are generally unknown. Using the solubility models' adjustments to Log Ksp described in this paper is recommended if the site‐specific Log Ksp is unknown.
- 1 March 2025
- Published by Wiley in AWWA Water Science
- Vol. 7 (2)
Lead Solubility in Drinking Water: A Comparison of Experimental Lead Solubility and Geochemical Modeling Predictions
Geochemical solubility modeling is a cost‐effective method to estimate equilibrium lead (Pb) concentrations in drinking water under specific environmental conditions. Laboratory Pb‐solubility studies (sometimes called coupon studies) are also economical and can generate comparative Pb solubility data for different water qualities. Both methods are widely used by utilities in screening corrosion control treatment, and both methods are assumed to provide insights on CCT for Pb without the influence of years of built‐up scale. No research has compared the two methods to see if they give similar results for the same water. While these techniques have limitations and do not always represent Pb levels in service lines and premise plumbing, they are valuable for predicting Pb solubility trends under controlled conditions. In this study, Pb coupons immersed in chemically diverse waters provided experimental data on Pb solubility, which was then compared to predictions from two widely used geochemical models, MINEQL+ and LEADSOL. In tests without orthophosphate (PO43−), experimental Pb concentrations increased as pH decreased, consistent with model predictions. Between pH 7.5 and 8.5, Pb levels slightly declined as predicted by the model but were less dependent on dissolved inorganic carbon (DIC) than model predictions. However, at pH 8.5–10, Pb concentrations remained constant experimentally, whereas the model predicted significant reductions in Pb. Neither MINEQL+ nor LEADSOL models and experimental data were statistically the same using the built‐in constants. Adjusting Log Ksp for hydrocerussite allowed the data and models to be statistically the same. In waters with PO43−, high DIC (50 mg/L as C) experimental results matched model predictions. At low DIC (3 mg/L as C), Pb concentrations varied less than modeled, and higher PO43− doses were needed to reduce Pb levels compared to low‐DIC waters. Overall, geochemical modeling and Pb solubility studies provide critical insights into Pb control strategies, and either or both methods can help screen the impact of possible water quality changes on Pb levels. Solubility testing is preferred, as site‐specific solubility constants are generally unknown. Using the solubility models' adjustments to Log Ksp described in this paper is recommended if the site‐specific Log Ksp is unknown.
- 1 September 2024
- Published by Wiley in AWWA Water Science
- Vol. 6 (5)
The use of lead isotopes for determining sources of lead in drinking water
A series of paired samples were analyzed to determine if high‐precision lead isotopic fingerprinting could help identify the source of lead in plumbing materials and drinking water. Samples were obtained of plumbing materials (lead service lines, copper pipe with lead solder, galvanized materials, and brass fixtures) from water utilities across the United States. Lead samples were taken from the material itself, from scales, and in some cases from associated water. The lead samples were analyzed to determine the ratios of the four stable lead isotopes present. The results enabled the identification of relationships between various components and further aided in the identification of the source of lead found in water and in pipe scales. Isotopic fingerprinting, as demonstrated in this study, could be used to determine if a galvanized line is a galvanized line requiring replacement (GRR) under the Lead and Copper Rule Improvements (USEPA, 2023).
- 1 September 2024
- Published by Wiley in AWWA Water Science
- Vol. 6 (5)
The use of lead isotopes for determining sources of lead in drinking water
A series of paired samples were analyzed to determine if high‐precision lead isotopic fingerprinting could help identify the source of lead in plumbing materials and drinking water. Samples were obtained of plumbing materials (lead service lines, copper pipe with lead solder, galvanized materials, and brass fixtures) from water utilities across the United States. Lead samples were taken from the material itself, from scales, and in some cases from associated water. The lead samples were analyzed to determine the ratios of the four stable lead isotopes present. The results enabled the identification of relationships between various components and further aided in the identification of the source of lead found in water and in pipe scales. Isotopic fingerprinting, as demonstrated in this study, could be used to determine if a galvanized line is a galvanized line requiring replacement (GRR) under the Lead and Copper Rule Improvements (USEPA, 2023).
- 1 July 2021
- Published by Wiley in AWWA Water Science
- Vol. 3 (4) , e1232
Measurements and modeling of lead reduction strategies
Three strategies for reducing lead in water and blood lead level (BLL) were evaluated. Approximately 2,500 lead samples from 112 homes were analyzed to estimate lead reduction from full lead service line replacement (FLSLR). Corrosion‐control changes were evaluated using data from more than 20,000 community water systems (CWSs). The reduction in first‐liter median lead for utilities changing corrosion‐control treatment (CCT) to drop the 90th percentile from 15 to 10 μg/L was 0.4 μg/L, while the reduction in lead for the highest 10% of the population in those communities was 3.7 μg/L. Lowering the goal to 5 μg/L resulted in the median and top 10% lead reducing by 0.4 and 4.5 μg/L, respectively, although more utilities and hence children are impacted by the lower goal. The median home had a first‐L and profile average lead reduction of about 2 μg/L following FLSLR. Ten percent of the homes saw a reduction in profile average lead of over 17 μg/L after FLSLR. These reductions in lead were converted to changes in BLL, including the percentage and total number of children with BLL values above 3.5 and 5 μg/dl. Those results show that the reduction in total number of children above these targets is noticeably higher for the 5 μg/L goal due to the difference in impacted population. LSL replacement provides the greatest reduction in number of children above these two candidate target values of BLL.Article Impact Statement: The largest reduction in BLL resulted from FLSLR. This is consistent with NDWAC report that FLSLR has a larger impact than improving CCT.
- 1 July 2021
- Published by Wiley in AWWA Water Science
- Vol. 3 (4) , e1232
Measurements and modeling of lead reduction strategies
Three strategies for reducing lead in water and blood lead level (BLL) were evaluated. Approximately 2,500 lead samples from 112 homes were analyzed to estimate lead reduction from full lead service line replacement (FLSLR). Corrosion‐control changes were evaluated using data from more than 20,000 community water systems (CWSs). The reduction in first‐liter median lead for utilities changing corrosion‐control treatment (CCT) to drop the 90th percentile from 15 to 10 μg/L was 0.4 μg/L, while the reduction in lead for the highest 10% of the population in those communities was 3.7 μg/L. Lowering the goal to 5 μg/L resulted in the median and top 10% lead reducing by 0.4 and 4.5 μg/L, respectively, although more utilities and hence children are impacted by the lower goal. The median home had a first‐L and profile average lead reduction of about 2 μg/L following FLSLR. Ten percent of the homes saw a reduction in profile average lead of over 17 μg/L after FLSLR. These reductions in lead were converted to changes in BLL, including the percentage and total number of children with BLL values above 3.5 and 5 μg/dl. Those results show that the reduction in total number of children above these targets is noticeably higher for the 5 μg/L goal due to the difference in impacted population. LSL replacement provides the greatest reduction in number of children above these two candidate target values of BLL.Article Impact Statement: The largest reduction in BLL resulted from FLSLR. This is consistent with NDWAC report that FLSLR has a larger impact than improving CCT.
- 1 May 2013
- Published by Wiley in Journal AWWA
- Vol. 105 (5) , 62-75
Strategies for assessing optimized corrosion control treatment of lead and copper
- 1 May 2013
- Published by Wiley in Journal AWWA
- Vol. 105 (5) , 62-75
Strategies for assessing optimized corrosion control treatment of lead and copper
- 1 March 2008
- Published by Wiley in Journal AWWA
- Vol. 100 (3) , 81-93
Implementing residuals management: Cost implications for coagulation and softening plants
- 1 March 2008
- Published by Wiley in Journal AWWA
- Vol. 100 (3) , 81-93
Implementing residuals management: Cost implications for coagulation and softening plants
- 1 January 2003
- Published by Elsevier
- p. 483-489
Disposal of wastes resulting from arsenic removal processes
- 1 January 2003
- Published by Elsevier
- p. 483-489
Disposal of wastes resulting from arsenic removal processes