Wendy Meulebroeck
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wendy Meulebroeck has a total of 70 co-authors. Here are the top co-authors by number of shared publications:
- Hugo Thienpont
Vrije Universiteit Brussel
38 shared publications - Herman Terryn
Vrije Universiteit Brussel, Research Group Sustainable Materials Engineering, Pleinlaan 2, 1050 Brussels, Belgium
15 shared publications - Andrea Ceglia
Vrije Univ. Brussel (Belgium)
13 shared publications Karin Nys
12 shared publications- Heidi Ottevaere
Vrije Universiteit Brussel
10 shared publications Peter Cosyns
Department of Art Sciences and Archaeology, MARI Research Group, Vrije Universiteit Brussel, Brussels, Belgium
8 shared publications
Latest Publications
- Open Access
- 12 November 2026
- Published by IOP Publishing in Journal of Physics: Photonics
Raman-based detection of lipid accumulation in 3D steatosis-induced liver cultures
Liver diseases represent a major global health threat due to their high prevalence and potential to progress into severe, irreversible stages. Steatosis, characterised by the excessive accumulation of lipids within the hepatocytes, is one of the most common early manifestations and potentially reversible. Consequently, there is a growing need for physiologically relevant in vitro models and analytical techniques that enable accurate assessment of the disease-associated cellular changes. Three-dimensional (3D) liver spheroid cultures better recapitulate key features of the native liver environment than conventional two-dimensional (2D) cell cultures, yet robust label-free methods for their characterisation remain limited. Here, we evaluate Raman mapping combined with multivariate curve resolution-alternating least squares (MCR-ALS) for the assessment of lipid accumulation in 3D HepG2-LX2 liver spheroids. Raman maps acquired from oleic acid/palmitic acid (OA/PA)-treated and control spheroids were decomposed into chemically meaningful components, enabling reconstruction of spatially resolved lipid-associated concentration profiles. Quantification of these profiles revealed a significant increase in lipid content in the OA/PA-treated spheroids compared to the controls and showed strong agreement with the lipid quantification obtained via BODIPY 493/503 fluorescence imaging, a widely used method for assessing lipid accumulation. In addition, time-resolved experiments demonstrated that the proposed workflow is not only sensitive to binary differences in lipid content, but also to intermediate stages of lipid accumulation. These findings demonstrate that Raman mapping combined with MCR-ALS enables label-free spatially resolved quantification of lipid accumulation in 3D liver spheroid models, providing a promising platform for studying lipid accumulation dynamics and evaluating therapeutic responses in physiologically relevant in vitro models.
- 12 November 2026
- Published by IOP Publishing in Journal of Physics: Photonics
Open AccessRaman-based detection of lipid accumulation in 3D steatosis-induced liver cultures
Liver diseases represent a major global health threat due to their high prevalence and potential to progress into severe, irreversible stages. Steatosis, characterised by the excessive accumulation of lipids within the hepatocytes, is one of the most common early manifestations and potentially reversible. Consequently, there is a growing need for physiologically relevant in vitro models and analytical techniques that enable accurate assessment of the disease-associated cellular changes. Three-dimensional (3D) liver spheroid cultures better recapitulate key features of the native liver environment than conventional two-dimensional (2D) cell cultures, yet robust label-free methods for their characterisation remain limited. Here, we evaluate Raman mapping combined with multivariate curve resolution-alternating least squares (MCR-ALS) for the assessment of lipid accumulation in 3D HepG2-LX2 liver spheroids. Raman maps acquired from oleic acid/palmitic acid (OA/PA)-treated and control spheroids were decomposed into chemically meaningful components, enabling reconstruction of spatially resolved lipid-associated concentration profiles. Quantification of these profiles revealed a significant increase in lipid content in the OA/PA-treated spheroids compared to the controls and showed strong agreement with the lipid quantification obtained via BODIPY 493/503 fluorescence imaging, a widely used method for assessing lipid accumulation. In addition, time-resolved experiments demonstrated that the proposed workflow is not only sensitive to binary differences in lipid content, but also to intermediate stages of lipid accumulation. These findings demonstrate that Raman mapping combined with MCR-ALS enables label-free spatially resolved quantification of lipid accumulation in 3D liver spheroid models, providing a promising platform for studying lipid accumulation dynamics and evaluating therapeutic responses in physiologically relevant in vitro models.
- 12 September 2025
- Published by Elsevier in Optics & Laser Technology
- Vol. 192
Microplastics analysis through a surface plasmon resonance microscopy system tailored for polymers detection
- 12 September 2025
- Published by Elsevier in Optics & Laser Technology
- Vol. 192
Microplastics analysis through a surface plasmon resonance microscopy system tailored for polymers detection
- Open Access
- 3 September 2025
- Published by MDPI AG in Microorganisms
- Vol. 13 (9) , 2048
A Collection and Analysis of Simplified Data for a Better Understanding of the Complex Process of Biofilm Inactivation by Ultraviolet and Visible Irradiation
Biofilms are communities of microorganisms that pose a problem in many areas, including the food industry, drinking water treatment, and medicine, because they can contain pathogens and are difficult to eliminate. For this reason, the possibility of biofilm reduction by ultraviolet (UV) or visible light was investigated using data from published reports. Results for different applications, spectral ranges, and microorganisms were compared by performing MANOVA tests. Approximately 140 publications were found that dealt with the irradiation of water or surfaces for biofilm reduction or reduction in biofilm formation. Irradiation of surfaces with UV or visible light in the spectral range 200–525 nm had a positive effect on biofilm reduction and reduction in biofilm formation, although the results for irradiation of water were conflicting. Most investigations were carried out on P. aeruginosa biofilms, but other Gram-positive and Gram-negative bacteria, as well as some fungi and their biofilm sensitivities to irradiation, were also analyzed. Limited data were available for the UVB (280–315 nm) and UVA (315–400 nm) range. Most experiments to date have been carried out in the UVC (100–280 nm) or in the visible violet/blue spectral (400–500 nm) range, with the UVC range being 2–3 orders of magnitude more efficient in terms of applied irradiation dose. Other quantitative statements were difficult to make as the results from the different working groups were highly scattered. Irradiation can reduce the microorganisms in biofilms but does not completely remove biofilms. New biofilm formation can at least be delayed by surface irradiation. Whether it is also possible to prevent the formation of new biofilms in the long term is open to question. Which irradiation wavelengths are optimal for anti-biofilm measures is also still unclear.
- 3 September 2025
- Published by MDPI AG in Microorganisms
- Vol. 13 (9) , 2048
Open AccessA Collection and Analysis of Simplified Data for a Better Understanding of the Complex Process of Biofilm Inactivation by Ultraviolet and Visible Irradiation
Biofilms are communities of microorganisms that pose a problem in many areas, including the food industry, drinking water treatment, and medicine, because they can contain pathogens and are difficult to eliminate. For this reason, the possibility of biofilm reduction by ultraviolet (UV) or visible light was investigated using data from published reports. Results for different applications, spectral ranges, and microorganisms were compared by performing MANOVA tests. Approximately 140 publications were found that dealt with the irradiation of water or surfaces for biofilm reduction or reduction in biofilm formation. Irradiation of surfaces with UV or visible light in the spectral range 200–525 nm had a positive effect on biofilm reduction and reduction in biofilm formation, although the results for irradiation of water were conflicting. Most investigations were carried out on P. aeruginosa biofilms, but other Gram-positive and Gram-negative bacteria, as well as some fungi and their biofilm sensitivities to irradiation, were also analyzed. Limited data were available for the UVB (280–315 nm) and UVA (315–400 nm) range. Most experiments to date have been carried out in the UVC (100–280 nm) or in the visible violet/blue spectral (400–500 nm) range, with the UVC range being 2–3 orders of magnitude more efficient in terms of applied irradiation dose. Other quantitative statements were difficult to make as the results from the different working groups were highly scattered. Irradiation can reduce the microorganisms in biofilms but does not completely remove biofilms. New biofilm formation can at least be delayed by surface irradiation. Whether it is also possible to prevent the formation of new biofilms in the long term is open to question. Which irradiation wavelengths are optimal for anti-biofilm measures is also still unclear.
- Open Access
- 6 August 2024
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 6 (4) , 045002
A rapid and quantitative absorption-based measurement to study the impact of antibiotics on bacterial growth
Given the global rise in antimicrobial resistance levels, there is an urgent need to obtain the minimal inhibitory concentration (MIC) of an antibiotic as early as possible. In this paper, we present the first test results of a light-based concept where the interaction of a laser beam with the drug–bacterium sample is used to calculate MIC values within 6 h after cultivation. For this preliminary study, a total of 163 drug–bacterium pairs were tested and benchmarked with broth microdilution (BMD). The pathogen set included Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa, Acinetobacter baumannii, Staphylococcus aureus, Staphylococcus capitis, Staphylococcus cohnii, Staphylococcus epidermis, Staphylococcus haemolyticus, Enterococcus and Streptococcus pneumoniae. The selected drugs belonged to 10 different classes. The method under investigation showed a categorical concordance of 86.1% and an essential agreement of 80.3% with BMD. Due to its simplicity, the concept can be easily implemented on existing commercial platforms. This research shows promise for further studies potentially leading to a novel concept that can be employed to rapidly determine MIC values.
- 6 August 2024
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 6 (4) , 045002
Open AccessA rapid and quantitative absorption-based measurement to study the impact of antibiotics on bacterial growth
Given the global rise in antimicrobial resistance levels, there is an urgent need to obtain the minimal inhibitory concentration (MIC) of an antibiotic as early as possible. In this paper, we present the first test results of a light-based concept where the interaction of a laser beam with the drug–bacterium sample is used to calculate MIC values within 6 h after cultivation. For this preliminary study, a total of 163 drug–bacterium pairs were tested and benchmarked with broth microdilution (BMD). The pathogen set included Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa, Acinetobacter baumannii, Staphylococcus aureus, Staphylococcus capitis, Staphylococcus cohnii, Staphylococcus epidermis, Staphylococcus haemolyticus, Enterococcus and Streptococcus pneumoniae. The selected drugs belonged to 10 different classes. The method under investigation showed a categorical concordance of 86.1% and an essential agreement of 80.3% with BMD. Due to its simplicity, the concept can be easily implemented on existing commercial platforms. This research shows promise for further studies potentially leading to a novel concept that can be employed to rapidly determine MIC values.
- Open Access
- 14 February 2024
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 6 (2) , 025002
Characterizing planar SERS substrates: unraveling the link between physical characteristics and performance metrics
Surface-enhanced Raman spectroscopy (SERS) is a powerful optical sensing technique used in various applications, including medicine, microbiology, and environmental analysis. Planar SERS substrates are of particular interest due to their ease of integration in lab-on-chips and better reproducibility compared to colloidal SERS. The performance of these SERS substrates is quantified using metrics such as enhancement factor, sensitivity, and reproducibility. However, there is yet to be a consensus on how to practically compare and interpret such metrics in publications and experiments. These performance metrics are strongly influenced by the nanostructures’ material, architecture, element sizes, as well as the circumstances surrounding the experiments. Understanding the effect of these characteristics on the SERS substrates’ performance could not only enable a better performance but also direct their development for different applications. Thus, we prepared a planar SERS-substrate characterization methodology to explore the correlation between the nanostructures’ physical characteristics and the performance metrics through coordinate-transformed spectroscopic measurements over structure-characterized areas. Seven commercial SERS substrates, with various surface architectures fabricated using different fabrication technologies, were studied using this benchmarking methodology. The results demonstrated how this methodology can indicate a SERS substrate’s suitability for a specific application, thus, guiding the substrate’s further adaptations or development.
- 14 February 2024
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 6 (2) , 025002
Open AccessCharacterizing planar SERS substrates: unraveling the link between physical characteristics and performance metrics
Surface-enhanced Raman spectroscopy (SERS) is a powerful optical sensing technique used in various applications, including medicine, microbiology, and environmental analysis. Planar SERS substrates are of particular interest due to their ease of integration in lab-on-chips and better reproducibility compared to colloidal SERS. The performance of these SERS substrates is quantified using metrics such as enhancement factor, sensitivity, and reproducibility. However, there is yet to be a consensus on how to practically compare and interpret such metrics in publications and experiments. These performance metrics are strongly influenced by the nanostructures’ material, architecture, element sizes, as well as the circumstances surrounding the experiments. Understanding the effect of these characteristics on the SERS substrates’ performance could not only enable a better performance but also direct their development for different applications. Thus, we prepared a planar SERS-substrate characterization methodology to explore the correlation between the nanostructures’ physical characteristics and the performance metrics through coordinate-transformed spectroscopic measurements over structure-characterized areas. Seven commercial SERS substrates, with various surface architectures fabricated using different fabrication technologies, were studied using this benchmarking methodology. The results demonstrated how this methodology can indicate a SERS substrate’s suitability for a specific application, thus, guiding the substrate’s further adaptations or development.
- Open Access
- 29 October 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-12
The interaction between daylight and fifteenth and sixteenth century glass windows from the Low Countries
The positive impact of daylight on various forms of life is well understood. The daylight conditions a person experiences inside a building strongly depend on the character of the glazing. Contemporary windows maximize the transmission of visible daylight. In post-medieval times glassmakers were confronted with less pure materials. Driven by the Reformation and Counter-Reformation they were at the same time challenged by the demand for increased daylight. Luckily, technological evolutions allowed the production of thinner windows. It is currently an open question if glassmakers in the (Southern) Low Countries during the booming economic period from the fifteenth to seventeenth century made use of the interplay between material and fabrication properties to bring light into the darkness. Therefore, this paper links the impact of glass purity and production technique to light transmission for a well-diagnosed group of excavated glass window pieces from the castle of Middelburg-in-Flanders and a set of roundels, all dating back to between the fifteenth and seventeenth centuries and explores what factors have influenced this technological improvement. A non-destructive approach making use of UV–vis–NIR absorption spectroscopy unveiled that the more recent material is less pure compared to the older dated material but that light transmission was maximized due to the applied production technique.
- 29 October 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-12
Open AccessThe interaction between daylight and fifteenth and sixteenth century glass windows from the Low Countries
The positive impact of daylight on various forms of life is well understood. The daylight conditions a person experiences inside a building strongly depend on the character of the glazing. Contemporary windows maximize the transmission of visible daylight. In post-medieval times glassmakers were confronted with less pure materials. Driven by the Reformation and Counter-Reformation they were at the same time challenged by the demand for increased daylight. Luckily, technological evolutions allowed the production of thinner windows. It is currently an open question if glassmakers in the (Southern) Low Countries during the booming economic period from the fifteenth to seventeenth century made use of the interplay between material and fabrication properties to bring light into the darkness. Therefore, this paper links the impact of glass purity and production technique to light transmission for a well-diagnosed group of excavated glass window pieces from the castle of Middelburg-in-Flanders and a set of roundels, all dating back to between the fifteenth and seventeenth centuries and explores what factors have influenced this technological improvement. A non-destructive approach making use of UV–vis–NIR absorption spectroscopy unveiled that the more recent material is less pure compared to the older dated material but that light transmission was maximized due to the applied production technique.
- 18 April 2019
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 36 (5) , 1273-1287
Semianalytical modeling of arbitrarily distributed quantum emitters embedded in nanopatterned hyperbolic metamaterials
Nanopatterned hyperbolic metamaterials (NPHMs) have proven to be efficient structures for enhancing the spontaneous emission rate () and quantum efficiency () of quantum emitters (QEs). However, many of the NPHM designs still rely on computationally costly 3D numerical simulations. In this context, we propose a fast, semianalytical method capable of calculating both and of QEs placed inside a medium bounded by nanopatterned structures. The low computational cost of our approach makes it attractive for optimizing the NPHMs’ geometrical parameters that maximize for a desired . Furthermore, we suggest a more realistic procedure to calculate the decay behavior of multiple QEs arbitrarily distributed in the NPHM. This calculation is only feasible with the knowledge of and mapped for all possible positions of the QEs, which is easily achieved with the proposed model. For the validation procedure, we compare the model results with those obtained by the FDTD method. We apply the proposed model to an NPHM composed of nine layers, with the polymer host layer embedded with rhodamine 6G, to maximize for a specified tenfold increase of . This procedure allowed to be increased by 69% and 170% for 1D and 2D nanopatterning, respectively. The time required to build the and maps (used in the calculation of the decay behavior) is reduced by approximately 96% when compared with those numerically calculated via FDTD.- 18 April 2019
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 36 (5) , 1273-1287
Semianalytical modeling of arbitrarily distributed quantum emitters embedded in nanopatterned hyperbolic metamaterials
Nanopatterned hyperbolic metamaterials (NPHMs) have proven to be efficient structures for enhancing the spontaneous emission rate () and quantum efficiency () of quantum emitters (QEs). However, many of the NPHM designs still rely on computationally costly 3D numerical simulations. In this context, we propose a fast, semianalytical method capable of calculating both and of QEs placed inside a medium bounded by nanopatterned structures. The low computational cost of our approach makes it attractive for optimizing the NPHMs’ geometrical parameters that maximize for a desired . Furthermore, we suggest a more realistic procedure to calculate the decay behavior of multiple QEs arbitrarily distributed in the NPHM. This calculation is only feasible with the knowledge of and mapped for all possible positions of the QEs, which is easily achieved with the proposed model. For the validation procedure, we compare the model results with those obtained by the FDTD method. We apply the proposed model to an NPHM composed of nine layers, with the polymer host layer embedded with rhodamine 6G, to maximize for a specified tenfold increase of . This procedure allowed to be increased by 69% and 170% for 1D and 2D nanopatterning, respectively. The time required to build the and maps (used in the calculation of the decay behavior) is reduced by approximately 96% when compared with those numerically calculated via FDTD.- 7 July 2018
- Published by Springer Nature
- p. 91-107
Terranova, a Popular Stone Imitation Cladding: Strategies and Techniques for Restoration
- 7 July 2018
- Published by Springer Nature
- p. 91-107
Terranova, a Popular Stone Imitation Cladding: Strategies and Techniques for Restoration
- 28 May 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10693, 1069302
Design of an optical refocusing illumination system for use in laser-scanning devices
Optical laser-scanning systems generally contain a scanning lens, like an f-theta lens, to enable a planar imaging field. However, commercially available f-theta lenses show limited working distances and scan fields, while their lens diameter rapidly scales with the scanning range giving rise to bulky lens systems. Therefore, we propose a novel scanning lens configuration, based on a compact tunable lens system, generating a planar imaging field within scanning configurations that require broad scanning fields at large working distances. Particularly, we developed a refocusing illumination lens system, comprising a voltage tunable liquid lens positioned in the centre between 2 passive aspherical lenses. Our novel developed optical system is implementable between the laser source and scanning mirror in a polygon laser-scanning system and ensures a constant spot size along a 640 mm scanning line at a working distance of 900 mm. The voltage tunable liquid lens (Arctic 316 lens of Varioptic) enables to adapt the focal length by the application of a voltage, while the passive aspherical lenses allow to enlarge the working distances and to correct for aberrations. We obtained a compact lens system (system length of 71.8 mm) showing a tunable back focal length between 1078 mm and 1134 mm and 1/e2 spot diameters between 229 μm and 238 μm along the scanning line. Furthermore, we successfully demonstrate the performance of our simulated advanced refocusing illumination system in a laser-based scanning configuration, indicating its potential for integration in industrial scanning systems operating at large working distances while requiring large scanning fields.
- 28 May 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10693, 1069302
Design of an optical refocusing illumination system for use in laser-scanning devices
Optical laser-scanning systems generally contain a scanning lens, like an f-theta lens, to enable a planar imaging field. However, commercially available f-theta lenses show limited working distances and scan fields, while their lens diameter rapidly scales with the scanning range giving rise to bulky lens systems. Therefore, we propose a novel scanning lens configuration, based on a compact tunable lens system, generating a planar imaging field within scanning configurations that require broad scanning fields at large working distances. Particularly, we developed a refocusing illumination lens system, comprising a voltage tunable liquid lens positioned in the centre between 2 passive aspherical lenses. Our novel developed optical system is implementable between the laser source and scanning mirror in a polygon laser-scanning system and ensures a constant spot size along a 640 mm scanning line at a working distance of 900 mm. The voltage tunable liquid lens (Arctic 316 lens of Varioptic) enables to adapt the focal length by the application of a voltage, while the passive aspherical lenses allow to enlarge the working distances and to correct for aberrations. We obtained a compact lens system (system length of 71.8 mm) showing a tunable back focal length between 1078 mm and 1134 mm and 1/e2 spot diameters between 229 μm and 238 μm along the scanning line. Furthermore, we successfully demonstrate the performance of our simulated advanced refocusing illumination system in a laser-based scanning configuration, indicating its potential for integration in industrial scanning systems operating at large working distances while requiring large scanning fields.