Veronika Kurilová
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Veronika Kurilová has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Andrej Thurzo
Department of Orthodontics, Regenerative and Forensic Dentistry, Faculty of Medicine, Comenius University in Bratislava, Bratislava, Slovakia
5 shared publications - Ivan Varga
Institute of Histology and Embryology, Faculty of Medicine, Comenius University in Bratislava, Bratislava, 81372, Slovakia; Institute of Anatomy and Anthropology, Faculty of Medicine, Riga Stradins University, Riga, 1007, Latvia
4 shared publications - Helena Kosnacova
Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovičova 3, 81219 Bratislava, Slovakia
3 shared publications - Bela Mriňáková
1st Department of Oncology, Faculty of Medicine, Comenius University Bratislava and St. Elisabeth Cancer Institute, Slovakia
2 shared publications - Bohuslav Novák
Department of Stomatology and Maxillofacial Surgery, Faculty of Medicine, Comenius University in Bratislava, 81250 Bratislava, Slovakia
2 shared publications - Branislav Galis
Department of Oral and Maxillofacial Surgery, Faculty of Medicine, Comenius University and University Hospital Bratislava, Ružinovská 6, 826 06 Bratislava, Slovakia
2 shared publications
Latest Publications
- Open Access
Smartphone-Based Facial Scanning as a Viable Tool for Facially Driven Orthodontics?
The current paradigm shift in orthodontic treatment planning is based on facially driven diagnostics. This requires an affordable, convenient, and non-invasive solution for face scanning. Therefore, utilization of smartphones’ TrueDepth sensors is very tempting. TrueDepth refers to front-facing cameras with a dot projector in Apple devices that provide real-time depth data in addition to visual information. There are several applications that tout themselves as accurate solutions for 3D scanning of the face in dentistry. Their clinical accuracy has been uncertain. This study focuses on evaluating the accuracy of the Bellus3D Dental Pro app, which uses Apple’s TrueDepth sensor. The app reconstructs a virtual, high-resolution version of the face, which is available for download as a 3D object. In this paper, sixty TrueDepth scans of the face were compared to sixty corresponding facial surfaces segmented from CBCT. Difference maps were created for each pair and evaluated in specific facial regions. The results confirmed statistically significant differences in some facial regions with amplitudes greater than 3 mm, suggesting that current technology has limited applicability for clinical use. The clinical utilization of facial scanning for orthodontic evaluation, which does not require accuracy in the lip region below 3 mm, can be considered.
Open AccessSmartphone-Based Facial Scanning as a Viable Tool for Facially Driven Orthodontics?
The current paradigm shift in orthodontic treatment planning is based on facially driven diagnostics. This requires an affordable, convenient, and non-invasive solution for face scanning. Therefore, utilization of smartphones’ TrueDepth sensors is very tempting. TrueDepth refers to front-facing cameras with a dot projector in Apple devices that provide real-time depth data in addition to visual information. There are several applications that tout themselves as accurate solutions for 3D scanning of the face in dentistry. Their clinical accuracy has been uncertain. This study focuses on evaluating the accuracy of the Bellus3D Dental Pro app, which uses Apple’s TrueDepth sensor. The app reconstructs a virtual, high-resolution version of the face, which is available for download as a 3D object. In this paper, sixty TrueDepth scans of the face were compared to sixty corresponding facial surfaces segmented from CBCT. Difference maps were created for each pair and evaluated in specific facial regions. The results confirmed statistically significant differences in some facial regions with amplitudes greater than 3 mm, suggesting that current technology has limited applicability for clinical use. The clinical utilization of facial scanning for orthodontic evaluation, which does not require accuracy in the lip region below 3 mm, can be considered.
- Open Access
- 23 June 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (13) , 7693
Dental Care and Education Facing Highly Transmissible SARS-CoV-2 Variants: Prospective Biosafety Setting: Prospective, Single-Arm, Single-Center Study
With the arrival of the highly transmissible Omicron variants (BA.4 and BA.5), dentistry faces another seasonal challenge to preserve the biosafety of dental care and education. With the aim of protecting patients, students, teachers and healthcare professionals, this paper introduces a prospective sustainable biosafety setting for everyday dental care and education. The setting developed by dental clinicians, epidemiologists, and teachers of dentistry consists of a combination of modern technologies focused on the air-borne part of the viral pathway. The introduced biosafety setting has been clinically evaluated after 18 months of application in the real clinical environment. The protocol has three fundamental pillars: (1) UVC air disinfection; (2) air saturation with certified virucidal essences with nebulizing diffusers; (3) complementary solutions including telehealth and 3D printing. A pseudonymous online smart form was used as the evaluation method. The protocol operates on the premise that everybody is a hypothetical asymptomatic carrier. The results of a clinical evaluation of 115 patient feedbacks imply that no virus transmission from patient to patient or from doctor to nurse was observed or reported using this protocol, and vice versa, although nine patients retrospectively admitted that the clinic visit is likely to be infectious. Despite these promising results, a larger clinical sample and exposition to the current mutated strains are needed for reliable conclusions about protocol virucidal efficiency in current dental environments.
- 23 June 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (13) , 7693
Open AccessDental Care and Education Facing Highly Transmissible SARS-CoV-2 Variants: Prospective Biosafety Setting: Prospective, Single-Arm, Single-Center Study
With the arrival of the highly transmissible Omicron variants (BA.4 and BA.5), dentistry faces another seasonal challenge to preserve the biosafety of dental care and education. With the aim of protecting patients, students, teachers and healthcare professionals, this paper introduces a prospective sustainable biosafety setting for everyday dental care and education. The setting developed by dental clinicians, epidemiologists, and teachers of dentistry consists of a combination of modern technologies focused on the air-borne part of the viral pathway. The introduced biosafety setting has been clinically evaluated after 18 months of application in the real clinical environment. The protocol has three fundamental pillars: (1) UVC air disinfection; (2) air saturation with certified virucidal essences with nebulizing diffusers; (3) complementary solutions including telehealth and 3D printing. A pseudonymous online smart form was used as the evaluation method. The protocol operates on the premise that everybody is a hypothetical asymptomatic carrier. The results of a clinical evaluation of 115 patient feedbacks imply that no virus transmission from patient to patient or from doctor to nurse was observed or reported using this protocol, and vice versa, although nine patients retrospectively admitted that the clinic visit is likely to be infectious. Despite these promising results, a larger clinical sample and exposition to the current mutated strains are needed for reliable conclusions about protocol virucidal efficiency in current dental environments.
- Open Access
- 8 April 2022
- Published by MDPI AG in Preprints.org
Biosafety in Dental Care Facing Highly Transmissible SARS-CoV-2 Variants: Introduction of Prospective Setting Protocol in Prevention of COVID-19
With arrival of highly transmissible Om icron variants in global pandemic, dentistry is facing another challenge to preserve biosafety of dental care. With a mission to protect both patients and healthcare workers, adaptability to the changing epidemiologic situation is required from dental professionals. This work presents a prospective sustainable biosafety setting for routine orthodontic care. The protocol i s composed from combination of available technologies focused on the air-borne part of a virus pathway. Introduced biosafety protocol has been clinically evaluated after 18 months of application in the real clinical environment. The protocol has three fundamental pillars: (1) UVC air disinfection; (2) air saturation with certified virucidal oils through nebulizing diffusers; (3) complementary solutions. As a method of evaluation pseudonymous on-line smart form was used. Protocol operates with premise that everybody as a hypothetical asymptomatic carrier. Results from 115 patient feedbacks imply that with this protocol in place, there was no observed or reported translation of virus from patient to another patient or from patient to doctor or nurse and vice versa, albeit nine patients have retrospectively admitted visiting the clinic as probably infectious. Despite promising results , a l arger clinical sample and exposition to current mutated strains is necessary for reliable conclusions about protocol virucidal efficiency .
- 8 April 2022
- Published by MDPI AG in Preprints.org
Open AccessBiosafety in Dental Care Facing Highly Transmissible SARS-CoV-2 Variants: Introduction of Prospective Setting Protocol in Prevention of COVID-19
With arrival of highly transmissible Om icron variants in global pandemic, dentistry is facing another challenge to preserve biosafety of dental care. With a mission to protect both patients and healthcare workers, adaptability to the changing epidemiologic situation is required from dental professionals. This work presents a prospective sustainable biosafety setting for routine orthodontic care. The protocol i s composed from combination of available technologies focused on the air-borne part of a virus pathway. Introduced biosafety protocol has been clinically evaluated after 18 months of application in the real clinical environment. The protocol has three fundamental pillars: (1) UVC air disinfection; (2) air saturation with certified virucidal oils through nebulizing diffusers; (3) complementary solutions. As a method of evaluation pseudonymous on-line smart form was used. Protocol operates with premise that everybody as a hypothetical asymptomatic carrier. Results from 115 patient feedbacks imply that with this protocol in place, there was no observed or reported translation of virus from patient to another patient or from patient to doctor or nurse and vice versa, albeit nine patients have retrospectively admitted visiting the clinic as probably infectious. Despite promising results , a l arger clinical sample and exposition to current mutated strains is necessary for reliable conclusions about protocol virucidal efficiency .
- Open Access
- 7 December 2021
- Published by MDPI AG in Healthcare
- Vol. 9 (12) , 1695
Artificial Intelligence in Orthodontic Smart Application for Treatment Coaching and Its Impact on Clinical Performance of Patients Monitored with AI-TeleHealth System
Background: Treatment of malocclusion with clear removable appliances like Invisalign® or Spark™, require considerable higher level of patient compliance when compared to conventional fixed braces. The clinical outcomes and treatment efficiency strongly depend on the patient’s discipline. Smart treatment coaching applications, like strojCHECK® are efficient for improving patient compliance. Purpose: To evaluate the impact of computerized personalized decision algorithms responding to observed and anticipated patient behavior implemented as an update of an existing clinical orthodontic application (app). Materials and Methods: Variables such as (1) patient app interaction, (2) patient app discipline and (3) clinical aligner tracking evaluated by artificial intelligence system (AI) system—Dental monitoring® were observed on the set of 86 patients. Two 60-day periods were evaluated; before and after the app was updated with decision tree processes. Results: All variables showed significant improvement after the update except for the manifestation of clinical non-tracking in men, evaluated by artificial intelligence from video scans. Conclusions: Implementation of application update including computerized decision processes can significantly enhance clinical performance of existing health care applications and improve patients’ compliance. Using the algorithm with decision tree architecture could create a baseline for further machine learning optimization.
- 7 December 2021
- Published by MDPI AG in Healthcare
- Vol. 9 (12) , 1695
Open AccessArtificial Intelligence in Orthodontic Smart Application for Treatment Coaching and Its Impact on Clinical Performance of Patients Monitored with AI-TeleHealth System
Background: Treatment of malocclusion with clear removable appliances like Invisalign® or Spark™, require considerable higher level of patient compliance when compared to conventional fixed braces. The clinical outcomes and treatment efficiency strongly depend on the patient’s discipline. Smart treatment coaching applications, like strojCHECK® are efficient for improving patient compliance. Purpose: To evaluate the impact of computerized personalized decision algorithms responding to observed and anticipated patient behavior implemented as an update of an existing clinical orthodontic application (app). Materials and Methods: Variables such as (1) patient app interaction, (2) patient app discipline and (3) clinical aligner tracking evaluated by artificial intelligence system (AI) system—Dental monitoring® were observed on the set of 86 patients. Two 60-day periods were evaluated; before and after the app was updated with decision tree processes. Results: All variables showed significant improvement after the update except for the manifestation of clinical non-tracking in men, evaluated by artificial intelligence from video scans. Conclusions: Implementation of application update including computerized decision processes can significantly enhance clinical performance of existing health care applications and improve patients’ compliance. Using the algorithm with decision tree architecture could create a baseline for further machine learning optimization.
- Open Access
- 12 November 2021
- Published by MDPI AG in Healthcare
- Vol. 9 (11) , 1545
Use of Advanced Artificial Intelligence in Forensic Medicine, Forensic Anthropology and Clinical Anatomy
Three-dimensional convolutional neural networks (3D CNN) of artificial intelligence (AI) are potent in image processing and recognition using deep learning to perform generative and descriptive tasks. Compared to its predecessor, the advantage of CNN is that it automatically detects the important features without any human supervision. 3D CNN is used to extract features in three dimensions where input is a 3D volume or a sequence of 2D pictures, e.g., slices in a cone-beam computer tomography scan (CBCT). The main aim was to bridge interdisciplinary cooperation between forensic medical experts and deep learning engineers, emphasizing activating clinical forensic experts in the field with possibly basic knowledge of advanced artificial intelligence techniques with interest in its implementation in their efforts to advance forensic research further. This paper introduces a novel workflow of 3D CNN analysis of full-head CBCT scans. Authors explore the current and design customized 3D CNN application methods for particular forensic research in five perspectives: (1) sex determination, (2) biological age estimation, (3) 3D cephalometric landmark annotation, (4) growth vectors prediction, (5) facial soft-tissue estimation from the skull and vice versa. In conclusion, 3D CNN application can be a watershed moment in forensic medicine, leading to unprecedented improvement of forensic analysis workflows based on 3D neural networks.
- 12 November 2021
- Published by MDPI AG in Healthcare
- Vol. 9 (11) , 1545
Open AccessUse of Advanced Artificial Intelligence in Forensic Medicine, Forensic Anthropology and Clinical Anatomy
Three-dimensional convolutional neural networks (3D CNN) of artificial intelligence (AI) are potent in image processing and recognition using deep learning to perform generative and descriptive tasks. Compared to its predecessor, the advantage of CNN is that it automatically detects the important features without any human supervision. 3D CNN is used to extract features in three dimensions where input is a 3D volume or a sequence of 2D pictures, e.g., slices in a cone-beam computer tomography scan (CBCT). The main aim was to bridge interdisciplinary cooperation between forensic medical experts and deep learning engineers, emphasizing activating clinical forensic experts in the field with possibly basic knowledge of advanced artificial intelligence techniques with interest in its implementation in their efforts to advance forensic research further. This paper introduces a novel workflow of 3D CNN analysis of full-head CBCT scans. Authors explore the current and design customized 3D CNN application methods for particular forensic research in five perspectives: (1) sex determination, (2) biological age estimation, (3) 3D cephalometric landmark annotation, (4) growth vectors prediction, (5) facial soft-tissue estimation from the skull and vice versa. In conclusion, 3D CNN application can be a watershed moment in forensic medicine, leading to unprecedented improvement of forensic analysis workflows based on 3D neural networks.
- Open Access
- 6 August 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-9
Support vector machine and deep-learning object detection for localisation of hard exudates
Hard exudates are one of the main clinical findings in the retinal images of patients with diabetic retinopathy. Detecting them early significantly impacts the treatment of underlying diseases; therefore, there is a need for automated systems with high reliability. We propose a novel method for identifying and localising hard exudates in retinal images. To achieve fast image pre-scanning, a support vector machine (SVM) classifier was combined with a faster region-based convolutional neural network (faster R-CNN) object detector for the localisation of exudates. Rapid pre-scanning filtered out exudate-free samples using a feature vector extracted from the pre-trained ResNet-50 network. Subsequently, the remaining samples were processed using a faster R-CNN detector for detailed analysis. When evaluating all the exudates as individual objects, the SVM classifier reduced the false positive rate by 29.7% and marginally increased the false negative rate by 16.2%. When evaluating all the images, we recorded a 50% reduction in the false positive rate, without any decrease in the number of false negatives. The interim results suggested that pre-scanning the samples using the SVM prior to implementing the deep-network object detector could simultaneously improve and speed up the current hard exudates detection method, especially when there is paucity of training data.
- 6 August 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-9
Open AccessSupport vector machine and deep-learning object detection for localisation of hard exudates
Hard exudates are one of the main clinical findings in the retinal images of patients with diabetic retinopathy. Detecting them early significantly impacts the treatment of underlying diseases; therefore, there is a need for automated systems with high reliability. We propose a novel method for identifying and localising hard exudates in retinal images. To achieve fast image pre-scanning, a support vector machine (SVM) classifier was combined with a faster region-based convolutional neural network (faster R-CNN) object detector for the localisation of exudates. Rapid pre-scanning filtered out exudate-free samples using a feature vector extracted from the pre-trained ResNet-50 network. Subsequently, the remaining samples were processed using a faster R-CNN detector for detailed analysis. When evaluating all the exudates as individual objects, the SVM classifier reduced the false positive rate by 29.7% and marginally increased the false negative rate by 16.2%. When evaluating all the images, we recorded a 50% reduction in the false positive rate, without any decrease in the number of false negatives. The interim results suggested that pre-scanning the samples using the SVM prior to implementing the deep-network object detector could simultaneously improve and speed up the current hard exudates detection method, especially when there is paucity of training data.