Ja’afar Adnan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ja’afar Adnan has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Nazrul Fariq Makmor
Faculty of Engineering, National Defence University of Malaysia, Sg. Besi Camp, 57000 Kuala Lumpur, Malaysia
3 shared publications - Fakroul Ridzuan Hashim
Faculty of Engineering, National Defence University of Malaysia, Sg. Besi Camp, 57000 Kuala Lumpur, Malaysia
2 shared publications - Mohd Taufiq Ishak
Faculty of Engineering, National Defence University of Malaysia, Kuala Lumpur, Malaysia
2 shared publications - Shahril Ahmad
Department of Electrical and Electronic Engineering, Faculty of Engineering, National Defense University of Malaysia, Kuala Lumpur, Malaysia
2 shared publications - Afzan Zamzamir
Faculty of Engineering, National Defence University of Malaysia, Sg. Besi Camp, 57000 Kuala Lumpur, Malaysia
1 shared publication Ardita Septiani
National Research and Innovation Agency Republic of Indonesia, Gedung BJ Habibie, Jakarta 10340, Indonesia
1 shared publication
Latest Publications
- Open Access
- 6 May 2025
- Published by Akademia Baru Publishing in Journal of Advanced Research Design
- Vol. 129 (1) , 89-100
Hybrid Multilayer Perceptron Neural Network for Transformer Health Index Monitoring
Power transformers are critical to electrical systems, requiring accurate health monitoring to ensure reliability and prevent failures. Traditional assessment methods often fail to capture complex variable interactions, resulting in suboptimal maintenance strategies. This study introduces a hybrid multilayer perceptron (HMLP) neural network for transformer health index (HI) monitoring, using approximately 500 data points from the Klang Valley, including gas formation data. The HMLP is benchmarked against classifiers such as multilayer perceptron (MLP), K-Nearest Neighbors (KNN), Linear Discriminant Analysis (LDA) and Support Vector Machine (SVM), outperforming them with 92.35% accuracy and a mean squared error (MSE) of 0.78. Additionally, three training algorithms; Backpropagation (BP), Levenberg-Marquardt (LM) and Bayesian Regularization (BR) were tested, with the BR algorithm achieving the best performance at 94.13% accuracy and an MSE of 0.39. This research highlights the potential of the HMLP network, particularly when trained with BR, to revolutionize transformer maintenance by enabling precise THI predictions, facilitating proactive interventions and ensuring power system reliability.
- 6 May 2025
- Published by Akademia Baru Publishing in Journal of Advanced Research Design
- Vol. 129 (1) , 89-100
Open AccessHybrid Multilayer Perceptron Neural Network for Transformer Health Index Monitoring
Power transformers are critical to electrical systems, requiring accurate health monitoring to ensure reliability and prevent failures. Traditional assessment methods often fail to capture complex variable interactions, resulting in suboptimal maintenance strategies. This study introduces a hybrid multilayer perceptron (HMLP) neural network for transformer health index (HI) monitoring, using approximately 500 data points from the Klang Valley, including gas formation data. The HMLP is benchmarked against classifiers such as multilayer perceptron (MLP), K-Nearest Neighbors (KNN), Linear Discriminant Analysis (LDA) and Support Vector Machine (SVM), outperforming them with 92.35% accuracy and a mean squared error (MSE) of 0.78. Additionally, three training algorithms; Backpropagation (BP), Levenberg-Marquardt (LM) and Bayesian Regularization (BR) were tested, with the BR algorithm achieving the best performance at 94.13% accuracy and an MSE of 0.39. This research highlights the potential of the HMLP network, particularly when trained with BR, to revolutionize transformer maintenance by enabling precise THI predictions, facilitating proactive interventions and ensuring power system reliability.
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3135 (1) , 040001
Comparison of solar harvesting by using static and multi axis dynamic photovoltaic module
Nowadays, solar energy can produce electricity to fill demand, and its green energy source leads to free pollution to our environment. This research aims to exa Nowadays, solar energy can produce electricity to fill demand, and its green energy source leads to free pollution to our environment. This research aims to exa
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3135 (1) , 040001
Comparison of solar harvesting by using static and multi axis dynamic photovoltaic module
Nowadays, solar energy can produce electricity to fill demand, and its green energy source leads to free pollution to our environment. This research aims to exa Nowadays, solar energy can produce electricity to fill demand, and its green energy source leads to free pollution to our environment. This research aims to exa
- Open Access
Lightning Impulse Breakdown Voltage of Rice Bran Oil for Transformer Application
Transformer oil does not only serve as an insulating liquid, but also in removing heat from the windings and cores. Mineral oil (MO) has been widely used in transformers for more than 150 years. Recently, researchers have attempted to search for alternative insulating oils due to the possibility that MO will run out in the future together with the concern on fire safety and environmental pollution. Among the potential oils is rice bran oil (RBO). This work presents the studies of the lightning impulse (LI) of RBO behavior under various electric fields, gap distances and testing methods. The electrical performances of LI tests show that RBO and Palm Oil (PO) have lower LI breakdown voltage than MO under both uniform and non-uniform electric fields. However, the difference in LI breakdown voltages between RBO, PO and MO are slightly small which is less than 20%. In addition, there is no significant effect in the various testing methods under both uniform field and non-uniform field where the percentages of difference are less than 12% and 8% respectively. The data of LI breakdown voltage were statistically analysed to predict the withstand voltage and 50% breakdown voltage of oil samples by using Weibull distribution. The Weibull distribution of MO, PO and RBO has well fit with the fitting line. Finally, the relationship between LI voltages under a non-uniform field with various parameters of PO and RBO was obtained and proposed. From this work, it can be concluded that RBO shows promising results to be considered as an alternative to MO in transformer applications.
Open AccessLightning Impulse Breakdown Voltage of Rice Bran Oil for Transformer Application
Transformer oil does not only serve as an insulating liquid, but also in removing heat from the windings and cores. Mineral oil (MO) has been widely used in transformers for more than 150 years. Recently, researchers have attempted to search for alternative insulating oils due to the possibility that MO will run out in the future together with the concern on fire safety and environmental pollution. Among the potential oils is rice bran oil (RBO). This work presents the studies of the lightning impulse (LI) of RBO behavior under various electric fields, gap distances and testing methods. The electrical performances of LI tests show that RBO and Palm Oil (PO) have lower LI breakdown voltage than MO under both uniform and non-uniform electric fields. However, the difference in LI breakdown voltages between RBO, PO and MO are slightly small which is less than 20%. In addition, there is no significant effect in the various testing methods under both uniform field and non-uniform field where the percentages of difference are less than 12% and 8% respectively. The data of LI breakdown voltage were statistically analysed to predict the withstand voltage and 50% breakdown voltage of oil samples by using Weibull distribution. The Weibull distribution of MO, PO and RBO has well fit with the fitting line. Finally, the relationship between LI voltages under a non-uniform field with various parameters of PO and RBO was obtained and proposed. From this work, it can be concluded that RBO shows promising results to be considered as an alternative to MO in transformer applications.
- 27 September 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2016 (1) , 020013
Heart abnormality activity detection using multilayer perceptron (MLP) network
Heart abnormality refers to the irregular electrical activity of the heart. Heart abnormality sometimes does not show any symptom and it is not sensible which may lead to sudden death due to the heart cease functioning. This paper attempts to develop a program that is capable to detect the heart abnormality activity through the implementation of Multilayer Perceptron (MLP). A certain amount of data of the heartbeat signals from electrocardiogram (ECG) will be used in this project to train the MLP network and to test the network performance. The MLP are trained by several techniques which are Backpropagation (BP), Bayesian Regularization (BR) and Levenberg-Marquardt (LM).
- 27 September 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2016 (1) , 020013
Heart abnormality activity detection using multilayer perceptron (MLP) network
Heart abnormality refers to the irregular electrical activity of the heart. Heart abnormality sometimes does not show any symptom and it is not sensible which may lead to sudden death due to the heart cease functioning. This paper attempts to develop a program that is capable to detect the heart abnormality activity through the implementation of Multilayer Perceptron (MLP). A certain amount of data of the heartbeat signals from electrocardiogram (ECG) will be used in this project to train the MLP network and to test the network performance. The MLP are trained by several techniques which are Backpropagation (BP), Bayesian Regularization (BR) and Levenberg-Marquardt (LM).
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
Cardiac abnormality prediction using HMLP network
Cardiac abnormality often occurs regardless of gender, age and races but depends on the lifestyle. This problem sometimes does not show any symptoms and usually detected once it already critical which lead to a sudden death to the patient. Basically, cardiac abnormality is the irregular electrical signal that generate by the pacemaker of the heart. This paper attempts to develop a program that can detect cardiac abnormality activity through implementation of Hybrid Multilayer Perceptron (HMLP) network. A certain amount of data of the heartbeat signals from the electrocardiogram (ECG) will be used in this project to train the MLP and HMLP network by using Modified Recursive Prediction Error (MRPE) algorithm and to test the network performance.
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
Cardiac abnormality prediction using HMLP network
Cardiac abnormality often occurs regardless of gender, age and races but depends on the lifestyle. This problem sometimes does not show any symptoms and usually detected once it already critical which lead to a sudden death to the patient. Basically, cardiac abnormality is the irregular electrical signal that generate by the pacemaker of the heart. This paper attempts to develop a program that can detect cardiac abnormality activity through implementation of Hybrid Multilayer Perceptron (HMLP) network. A certain amount of data of the heartbeat signals from the electrocardiogram (ECG) will be used in this project to train the MLP and HMLP network by using Modified Recursive Prediction Error (MRPE) algorithm and to test the network performance.