Fotis Dimopoulos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Fotis Dimopoulos has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Christos Gogos
Department of Endodontology, Faculty of Dentistry, School of Dentistry, Aristotle University of Thessaloniki, Thessaloniki, Greece
4 shared publications - Konstantinos Kodonas
Department of Endodontology, Faculty of Dentistry, School of Dentistry, Aristotle University of Thessaloniki, Thessaloniki, Greece
3 shared publications - Elisabeth A. Koulaouzidou
Division of Dental Tissues’ Pathology and Therapeutics (Basic Dental Sciences, Endodontology and Operative Dentistry), School of Dentistry, Aristotle University Thessaloniki, 541 24 Thessaloniki, Greece
2 shared publications - Alexandros K. Nikolaidis
Division of Dental Tissues’ Pathology and Therapeutics (Basic Dental Sciences, Endodontology and Operative Dentistry), School of Dentistry, Aristotle University Thessaloniki, 541 24 Thessaloniki, Greece
1 shared publication - Anastasia Fardi
Department of Dentoalveolar Surgery, Implantology and Oral Radiology, Faculty of Dentistry, School of Dentistry, Aristotle University of Thessaloniki, Thessaloniki, Greece
1 shared publication - Hany Mohamed Aly Ahmed
Department of Restorative Dentistry, Faculty of Dentistry, Universiti Malaya, Kuala Lumpur, Malaysia
1 shared publication
Latest Publications
- Open Access
- 23 January 2026
- Published by IOP Publishing in Biomedical Materials
- Vol. 21 (2)
The impact of nanoparticles on the physicochemical properties of epoxy resin-based endodontic sealers: A systematic review with a network and pairwise meta-analysis
Background Epoxy resin–based sealers (ERBSs) are well-established in endodontics. This review evaluated whether the incorporation of nanoparticles (NP) alters their standardized physicochemical properties and further examined potential dose–response effects and the existence of a minimum effective NP weight percentage. Method PubMed, Scopus, Embase, and Web of Science were searched to January 2025. In vitro studies comparing NP-modified and unmodified ERBSs were included if they evaluated ISO/ANSI-ADA–defined properties. Risk of bias was assessed using the QUIN tool. Pairwise and Bayesian/frequentist network meta-analyses were performed. Results Eleven in vitro studies were included. Pairwise meta-analysis showed lower flow for NP-modified ERBSs at 2 wt% compared to controls (MD= -2.29, 95 %CI – 2.91 -1.68). No significant differences were found for solubility (MD 0.01; 95% CI: -0.09 – 0.12), radiopacity (MD 0.06; 95%CI -0.08 – 0.2), or setting time (MD 18.0833 95 %CI -3.09 – 39.25). Network meta-analysis indicated low NP loadings (0.10–0.15 wt%) most improved flow and solubility, while higher loadings (≥5 wt%) reduced flow. A partial dose–response trend was detected for flow and solubility. Discussion A dose-dependent relationship was observed, with lower percentages improving performance, while higher percentages presented adverse effects. Limitations were identified in the included studies such as the lack of particle characterization, inadequate dispersion techniques, and absence of sample size calculation. Subgroup analyses were not feasible due to limited data. Conclusion NPs can be incorporated into ERBSs without compromising their core physicochemical properties. Low weight percentage may enhance performance, but further standardized research is needed to confirm their effect on antibacterial and biological properties and ensure clinical relevance.
- 23 January 2026
- Published by IOP Publishing in Biomedical Materials
- Vol. 21 (2)
Open AccessThe impact of nanoparticles on the physicochemical properties of epoxy resin-based endodontic sealers: A systematic review with a network and pairwise meta-analysis
Background Epoxy resin–based sealers (ERBSs) are well-established in endodontics. This review evaluated whether the incorporation of nanoparticles (NP) alters their standardized physicochemical properties and further examined potential dose–response effects and the existence of a minimum effective NP weight percentage. Method PubMed, Scopus, Embase, and Web of Science were searched to January 2025. In vitro studies comparing NP-modified and unmodified ERBSs were included if they evaluated ISO/ANSI-ADA–defined properties. Risk of bias was assessed using the QUIN tool. Pairwise and Bayesian/frequentist network meta-analyses were performed. Results Eleven in vitro studies were included. Pairwise meta-analysis showed lower flow for NP-modified ERBSs at 2 wt% compared to controls (MD= -2.29, 95 %CI – 2.91 -1.68). No significant differences were found for solubility (MD 0.01; 95% CI: -0.09 – 0.12), radiopacity (MD 0.06; 95%CI -0.08 – 0.2), or setting time (MD 18.0833 95 %CI -3.09 – 39.25). Network meta-analysis indicated low NP loadings (0.10–0.15 wt%) most improved flow and solubility, while higher loadings (≥5 wt%) reduced flow. A partial dose–response trend was detected for flow and solubility. Discussion A dose-dependent relationship was observed, with lower percentages improving performance, while higher percentages presented adverse effects. Limitations were identified in the included studies such as the lack of particle characterization, inadequate dispersion techniques, and absence of sample size calculation. Subgroup analyses were not feasible due to limited data. Conclusion NPs can be incorporated into ERBSs without compromising their core physicochemical properties. Low weight percentage may enhance performance, but further standardized research is needed to confirm their effect on antibacterial and biological properties and ensure clinical relevance.
- Open Access
- 16 December 2025
- Published by Wiley in European Journal of Oral Sciences
- Vol. 134 (2) , e70059
Epoxy resin‐based sealers modified with clay nanoparticles: Evaluation of their physicochemical and mechanical properties
Epoxy resin‐based sealers are commonly used in endodontic treatment due to their superior physicochemical properties. Therefore, it is important to utilize these materials by enhancing their properties. Nonetheless, several of their properties remain suboptimal, including the relatively prolonged setting time, the moderate yet clinically relevant solubility, the limitations in flow, and the need for enhanced dimensional stability. This study aimed to investigate the effect of different concentrations of organically modified montmorillonite (MMT) nanoclays on the physicochemical properties of two epoxy resin endodontic sealers. Sealers AH26 and AHplus were tested in their commercial unmodified form (controls) and with the addition of 0.5%, 1%, and 2% MMT modified with cetyltrimethylammonium. The morphological and structural characteristics of the obtained nanocomposites were studied by means of scanning electron microscopy and x‐ray diffraction. The study included five evaluations: setting time, flowability, solubility, dimensional change, and compressive strength of the sealers, following the International Standard Organization 6876:2001. The setting time, flow, and solubility values of all modified samples were lower, whereas the compressive strength was higher than seen for unmodified sealers. However, the dimensional change in the control group for both sealers was significantly lower than in the nanoparticle groups.
- 16 December 2025
- Published by Wiley in European Journal of Oral Sciences
- Vol. 134 (2) , e70059
Open AccessEpoxy resin‐based sealers modified with clay nanoparticles: Evaluation of their physicochemical and mechanical properties
Epoxy resin‐based sealers are commonly used in endodontic treatment due to their superior physicochemical properties. Therefore, it is important to utilize these materials by enhancing their properties. Nonetheless, several of their properties remain suboptimal, including the relatively prolonged setting time, the moderate yet clinically relevant solubility, the limitations in flow, and the need for enhanced dimensional stability. This study aimed to investigate the effect of different concentrations of organically modified montmorillonite (MMT) nanoclays on the physicochemical properties of two epoxy resin endodontic sealers. Sealers AH26 and AHplus were tested in their commercial unmodified form (controls) and with the addition of 0.5%, 1%, and 2% MMT modified with cetyltrimethylammonium. The morphological and structural characteristics of the obtained nanocomposites were studied by means of scanning electron microscopy and x‐ray diffraction. The study included five evaluations: setting time, flowability, solubility, dimensional change, and compressive strength of the sealers, following the International Standard Organization 6876:2001. The setting time, flow, and solubility values of all modified samples were lower, whereas the compressive strength was higher than seen for unmodified sealers. However, the dimensional change in the control group for both sealers was significantly lower than in the nanoparticle groups.
- Open Access
- 6 June 2022
- Published by MDPI AG in Dentistry Journal
- Vol. 10 (6) , 100
Shear Bond Strength of Ah26 to Human Dentin Treated with Dimethyl Sulfoxide (Dmso)
The purpose of this study was to examine the bond strength of AH26 to human coronal dentin exposed to DMSO. A total of 70 dentin specimens were equally divided into two groups. Each dentin surface was pre-treated with 2 mL of 2.5% NaOCl, 3 mL of EDTA 17%, and distilled water. One group was finally rinsed with 50% DMSO. Following the AH26 application, the bond strength was tested by subjecting the samples to a shear load at a crosshead speed of 0.5 mm/min using universal testing equipment. The results according to paired samples t-test indicated that there was a statistically insignificant difference between the two groups. Therefore, DMSO had no effect on the bond strength of AH26 root sealer to dentin.
- 6 June 2022
- Published by MDPI AG in Dentistry Journal
- Vol. 10 (6) , 100
Open AccessShear Bond Strength of Ah26 to Human Dentin Treated with Dimethyl Sulfoxide (Dmso)
The purpose of this study was to examine the bond strength of AH26 to human coronal dentin exposed to DMSO. A total of 70 dentin specimens were equally divided into two groups. Each dentin surface was pre-treated with 2 mL of 2.5% NaOCl, 3 mL of EDTA 17%, and distilled water. One group was finally rinsed with 50% DMSO. Following the AH26 application, the bond strength was tested by subjecting the samples to a shear load at a crosshead speed of 0.5 mm/min using universal testing equipment. The results according to paired samples t-test indicated that there was a statistically insignificant difference between the two groups. Therefore, DMSO had no effect on the bond strength of AH26 root sealer to dentin.
- Open Access
- 1 January 2021
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
- Vol. 46 (3)
Traditional and minimally invasive access cavities in endodontics: a literature review
Kapetanaki I, et al. Restor Dent Endod. 2021 Aug;46(3):e46. https://doi.org/10.5395/rde.2021.46.e46
- 1 January 2021
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
- Vol. 46 (3)
Open AccessTraditional and minimally invasive access cavities in endodontics: a literature review
Kapetanaki I, et al. Restor Dent Endod. 2021 Aug;46(3):e46. https://doi.org/10.5395/rde.2021.46.e46