SPSung Hyun Park

Sung Hyun Park

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sung Hyun Park has a total of 63 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Layer-Selective 3D Printing of Monolithic ECG Patches for Wearable Bioelectronics

    by Hyeon Yun Jeong, Hyeon Beom Kim, Soo Wan Kim, Hyeok Bin Lee, Jeong Beom Ko, Chul Ung Kang, Daeha Joung, Byung Choo Moon, Sung Hyun Park

  • A wide-range flexible capacitive pressure sensor with a 3D-architected honeycomb-bellows dielectric layer

    by Soo Wan Kim, Hyeok Bin Lee, Hyeon Yun Jeong, Sung Hyun Park, Byeong Su Kang, Jeong Beom Ko, Hyung Chan Kim, Geum Yoon Oh, Hyeon Beom Kim

  • Open Access

    In‐Process Magnetization for 3D Printing of Magnetorheological Elastomer with Heterogeneous Magnetic Profile for Anisotropic Actuation

    by Phillip Glass, David Hassouna, Udena Epitawala Arachchige, Hyeon Yun Jeong, Sung Hyun Park, Daeha Joung

    Soft magnetic actuators have gained significant interest for applications in minimally invasive medical robots, artificial muscles, soft robotic manipulators, and wearable bioelectronic interfaces, yet their functionality remains fundamentally limited by current magnetization strategies. To this end, a novel in‐process printing and magnetization strategy with spatial and dynamic control of an external magnetic field during printing is developed to fabricate magnetorheological elastomers with fully customizable three‐dimensional (3D) magnetization profiles. This method allows localized magnetic domain alignment in arbitrarily programmed orientations within a solid, enabling anisotropic actuation at micron to millimeter scales. The proposed method is highly sensitive to curing kinetics, material viscosity, and magnet positioning, which are characterized theoretically, experimentally, and in simulation. Structures magnetized in this way offer robust strain‐sensing, information‐encoding, and bio‐inspired heterogeneous actuation capabilities. Demonstrations highlight this versatility, including a dragonfly with oppositely magnetized wings for tunable resonant actuation, an octopus‐inspired swimmer whose magnetized legs reproduce aquatic locomotion, and a serpentine catheter with high degrees of freedom across 6 magnetic nodes. Together, these advances establish a versatile platform for designing magnetically responsive systems that couple programmable anisotropic actuation with biological complexity.


  • A flexible capacitive pressure sensor with a monolithically 3D-Printed arch-structured dielectric layer

    by Hyeok Bin Lee, Soo Wan Kim, Hyeon Yun Jeong, Young Jin Yang, Sung Hyun Park, Chul Ung Kang, Hyeon Beom Kim


  • Open Access

    Water‐ and oxidation‐resistant MXenes for advanced electromagnetic interference shielding applications

    by Young Ho Jin, Ju‐Hyoung Han, Jaeeun Park, Mincheal Kim, Shi‐Hyun Seok, Yujin Chae, Yeoseon Sim, Sangjin Seo, Hyeonwoo Lee, Jaewon Wang, et al.

    Two‐dimensional transition metal carbides and nitrides (MXenes) show great promise for electromagnetic interference (EMI) shielding. However, their susceptibility to oxidation, particularly in humid environments or water, limits their industrial applications. This study introduces a straightforward method for developing functionalized MXenes (F‐MXenes) with significantly enhanced oxidation resistance and environmental stability, which are critical factors for industrial scalability. The resulting F‐MXenes disperse easily in non‐polar solvents, adhere well to various substrates, and remain highly stable under harsh conditions in an accelerated oxidation test at 100°C and 80% relative humidity for 49 days; F‐MXenes retained 93% of their initial electrical resistance. Additionally, these films withstand water exposure, maintain superior current retention in seawater and corrosive environments, and exhibit high flexibility (10 000 bending cycles) and tensile strength (35 MPa). Notably, the EMI shielding effectiveness of the hydrophobic F‐MXene films, produced using scalable techniques such as spray and blade coating, far exceeds that of previously reported hydrophobic MXene films and MXene composites, achieving 52–77 dB at thicknesses of 5–40 μm. This study highlights the potential of F‐MXene as high‐performance, scalable EMI‐shielding coatings, particularly in humid or water‐exposed environments. image


  • Open Access

    Robust 2D layered MXene matrix–boron carbide hybrid films for neutron radiation shielding

    by Ju-Hyoung Han, Shi-Hyun Seok, Young Ho Jin, Jaeeun Park, Yunju Lee, Haeng Un Yeo, Jong-Ho Back, Yeoseon Sim, Yujin Chae, Jaewon Wang, et al.

    Large-scale fabrication of neutron-shielding films with flexible or complex shapes is challenging. Uniform and high boron carbide (B4C) filler loads with sufficient workability are needed to achieve good neutron-absorption capacity. Here, we show that a two-dimensional (2D) Ti3C2Tx MXene hybrid film with homogeneously distributed B4C particles exhibits high mechanical flexibility and anomalous neutron-shielding properties. Layered and solution-processable 2D Ti3C2Tx MXene flakes serve as an ideal robust and flexible matrix for high-content B4C fillers (60 wt.%). In addition, the preparation of a scalable neutron shielding MXene/B4C hybrid paint is demonstrated. This composite can be directly integrated with various large-scale surfaces (e.g., stainless steel, glass, and nylon). Because of their low thickness, simple and scalable preparation method, and an absorption capacity of 39.8% for neutrons emitted from a 241Am9Be source, the 2D Ti3C2Tx MXene hybrid films are promising candidates for use in wearable and lightweight applications.


  • Open Access

    3D‐Printed Artificial Cilia Arrays: A Versatile Tool for Customizable Mechanosensing

    by Phillip Glass, Andy Shar, Charles Pemberton, Ethan Nguyen, Sung Hyun Park, Daeha Joung

    Bio‐inspired cilium‐based mechanosensors offer a high level of responsiveness, making them suitable for a wide range of industrial, environmental, and biomedical applications. Despite great promise, the development of sensors with multifunctionality, scalability, customizability, and sensing linearity presents challenges due to the complex sensing mechanisms and fabrication methods involved. To this end, high‐aspect‐ratio polycaprolactone/graphene cilia structures with high conductivity, and facile fabrication are employed to address these challenges. For these 3D‐printed structures, an “inter‐cilium contact” sensing mechanism that enables the sensor to function akin to an on‐off switch, significantly enhancing sensitivity and reducing ambiguity in detection, is proposed. The cilia structures exhibit high levels of customizability, including thickness, height, spacing, and arrangement, while maintaining mechanical robustness. The simplicity of the sensor design enables highly sensitive detection in diverse applications, encompassing airflow and water flow monitoring, braille detection, and debris recognition. Overall, the unique conductive cilia‐based sensing mechanism that is proposed brings several advantages, advancing the development of multi‐sensing capabilities and flexible electronic skin applications in smart robotics and human prosthetics.


  • 3D Printable One‐Part Carbon Nanotube‐Elastomer Ink for Health Monitoring Applications

    by Andy Shar, Phillip Glass, Sung Hyun Park, Daeha Joung

    3D printing of conductive elastomers is a promising route to personalized health monitoring applications due to its flexibility and biocompatibility. Here, a one‐part, highly conductive, flexible, stretchable, 3D printable carbon nanotube (CNT)‐silicone composite is developed and thoroughly characterized. The one‐part nature of the inks: i) enables printing without prior mixing and cures under ambient conditions; ii) allows direct dispensing at ≈100 µm resolution printability on nonpolar and polar substrates; iii) forms both self‐supporting and high‐aspect‐ratio structures, key aspects in additive biomanufacturing that eliminate the need for sacrificial layers; and iv) lends efficient, reproducible, and highly sensitive responses to various tensile and compressive stimuli. The high electrical and thermal conductivity of the CNT‐silicone composite is further extended to facilitate use as a flexible and stretchable heating element, with applications in body temperature regulation, water distillation, and dual temperature sensing and Joule heating. Overall, the facile fabrication of this composite points to excellent synergy with direct ink writing and can be used to prepare patient‐specific wearable electronics for motion detection and cardiac and respiratory monitoring devices and toward advanced personal health tracking and bionic skin applications.


  • Open Access

    3D-printed flexible organic light-emitting diode displays

    by Ruitao Su, Sung Hyun Park, Xia Ouyang, Song Ih Ahn, Michael C. McAlpine

    OLED arrays were fully 3D-printed under ambient conditions to produce a flexible information display technology.


  • Open Access

    Highly Sensitive and Flexible Capacitive Pressure Sensor Based on Alignment Airgap Dielectric Layer

    by Soo Wan Kim, Geum Yun Oh, Young Jin Yang, Jeong Beom Ko, Young Woo Kim, Sung Hyun Park, Hyeon Beom Kim, Youngsun Hong

    Flexible capacitive pressure sensors with a simple structure and low power consumption are attracting attention owing to their wide range of applications in wearable electronic devices. However, it is difficult to manufacture pressure sensors with high sensitivity, wide detection range, and low detection limits. We developed a highly sensitive and flexible capacitive pressure sensor based on the porous Ecoflex, which has an aligned airgap structure and can be manufactured by a simply using a mold and micro-needle. The existence of precisely aligned airgap structures significantly improved the sensor sensitivity compared to other dielectric structures without airgaps. The proposed capacitive pressure sensor with an alignment airgap structure supports a wide range of working pressures (1 Pa – 100 kPa), quick response time (≈100 ms), high operational stability, and low-pressure detection limit (20 Pa). Moreover, we also studied the application of pulse wave monitoring in wearable sensors, exhibiting excellent performance in wearable devices that detect pulse waves before and after exercise. The proposed pressure sensor is applicable in electronic skin and wearable medical assistive devices owing to its excellent functional features.